• Title/Summary/Keyword: H2Pc

Search Result 739, Processing Time 0.03 seconds

Design of an Intelligent Ambulatory Monitoring System Using Flash Memory Card (Flash Memory Card를 이용한 Intelligent Ambulatory Monitoring 시스템 설계)

  • Song, G.K.;Lee, K.J.;Yoon, H.R.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.330-333
    • /
    • 1997
  • In this paper, we designed a low power and small-sized, light weighted intelligent ambulatory monitoring system using a flash memory card. The system's hardware specifications are as follows: 2 channels, 8bit/250Hz sampling rate, 20M byte storage capacity, a single-chip microcontroller (68HC11E9). To easily interface with PC based system, FFS(Flash File System) was used. We obtained the QRS detection rate of 99.14 through the evaluation with MIT/BIH database.

  • PDF

The electrophotographic characteristics of the duble-layered orgaic photoreceptors for the laser printer (레이저 프린터용 이층형 유기감광막의 전자사진특성)

  • 박종관;박구범;이덕출
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.4
    • /
    • pp.53-60
    • /
    • 1998
  • The purpose of this paper is to meausre the electrophotographic characteristics of double-layered organic photoreceptor and to evaluate an application for the laser beam printer drum. The characte carrier generation layer(CGL) of double-layered photoreceptor was fabricated with .tau.-H$_{2}$Pc which has high photosensitivity in the near-infrareed region(thickness is about 0.3.mu.m), and Oxadiazole derivative was chosen as a charge carrier transport layer(CTL) because of its high hole mobility. To observe the electrophotographic characteristics of the photoreceptor, we measured the charge acceptance, dark-decay ratio, residual potential after light irradiation. From the result of this study, proper thickness of CTL was about 10.mu.m. Also it's realized that electrophotographic characteristics of the photoreceptor were depend on the thickness of the CTL and the initial surface potential.

  • PDF

Technical Trend on IPTV Both Direction Service and Road Map (IPTV 양방향 서비스 기술 동향과 로드맵)

  • Kim, W.S.;Kim, J.Y.;Park, G.S.;Kang, C.H.
    • Electronics and Telecommunications Trends
    • /
    • v.25 no.2
    • /
    • pp.101-111
    • /
    • 2010
  • IPTV란 Internet Protocol TeleVision의 머릿글자의 조합이며, IP 네트워크상의 서버들이 제공하는 콘텐츠(contents)를 시청할 모니터이다. 먼저, 미국의 홈 쇼핑 네트워크, 일본의 액트빌라, MS Mediaroom 솔류션, MS Mediaroom 적용 사례 U-verse를 통한 IPTV 활용 사례를 살펴보고 이어, IPTV 양방향 서비스 기술로 PC나 핸드폰에 이어 새로운 콘텐츠 채널로서 기대되는 TV용 위젯에 대한 동향을 살펴본 후 관련 기술의 로드맵을 정리하고자 한다. 한편, 적기(time to market)에 시장이 요구하는 제품이나 차세대 기술을 파악하는 데 필요한 기술 로드맵이 관련 분야의 전문 종사자들을 통하여 확인, 검증, 개선 및 수정을 거치면서 공론화되는 구조가 형성되기를 제안하기 위하여 일상적 기술 사례 조사 기술동향 파악 상세 기술 분석을 통한 로드맵 도출의 한 사례 혹은 템플릿으로 본 고를 작성하였다.

Phytochemical and Antioxidant Activity of Spathodea campanulata P. Beauvois. Growing in Egypt

  • Nazif, Naglaa M.
    • Natural Product Sciences
    • /
    • v.13 no.1
    • /
    • pp.11-16
    • /
    • 2007
  • Alcoholic extract of Spathodea campanulata P. aerial parts, and two of the isolated fractions from celite column showed strong antioxidant activity (92, 94 & 89% RSA, Radical Scavenging Activity). Phytochemical investigation of chloroform/EtOAc faction of this column led to the isolation of phenolic acids, caffiec acid (1), and ferulic acid (2), fraction EtOAc/MeOH on further fractionation afforded 3 Flavonoids, kampferol 3-O-glucoside (3), quercetin 3-methyl ether (4) and 8-methoxy kampferol 3-O-glucoside (5). The isolated constituents were identified by co chromatography with authentic samples, TLC, PC., UV, MS and $^1H-NMR$. Also the lipoidal matter of the plant was studied. The unsaponifiable matter was found to be mixture of hydrocarbons from $(C_{14}-C_{28})$, cholesterol, campasterol, stigmasterol, and ${\alpha}-amyrin$. Fatty acid methyl esters were found to contain 12 fatty acids. The fatty acids containing $C_{18}$ farmed ca.65% of the total mixture.

Detection of Cytosolic Phosphatidylethanolamine N -Methyltransferase in Rat Brain

  • Kim, Young-Jun;Park, Heung-Soon;Choi, Myung-Un
    • BMB Reports
    • /
    • v.31 no.2
    • /
    • pp.170-176
    • /
    • 1998
  • Phosphatidylethanolamine N-methyltransferase (PEMT) is known to be a membrane-associated protein. However, cytosolic PEMT was detected when sufficient amounts of exogenous phospholipids were added in the incubation media. The methylation of phospholipids was measured by the incorporation of the $[^3H]-methyl$ group from S-adenosylmethionine and the methylated phospholipids were analyzed by thinlayer chromatography. The essence of the assay condition for the cytosolic enzyme was the inclusion of 200 ${\mu}g$ of each substrate, phosphatidylethanolamine (PE), phosphatidyl N-monomethylethanolamine (PME) and phosphatidyl N,N-dimethylethanolamine (PDE), in the reaction mixture of 100 ${\mu}l$. The subcellular fractionation of brain PEMT activities revealed that approximately 38.1 % for PME, 39.5% for PDE, and 22.4% for PC formation was present in the cytosolic fraction. The general properties of cytosolic PEMT were characterized and compared with those of neuronal nuclei PEMT.

  • PDF

A Digital Signal Processing System for Analysis of Skeletal Muscle EMG Signal (골격근의 근전도 신호 분석을 위하 디지탈 신호처리 시스템의 설계)

  • 전철완
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.2
    • /
    • pp.155-164
    • /
    • 1996
  • In the clinical environment, measurements of some characteristics of the skeletal muscle are currently used to assess the severity of a neuromuscular disease or in some cases to assist in making a diagnosis. But a quantitative method of evaluation has not yet been introduced satisfactorily. In this paper, the skeletal EMG(biceps muscle, masseter muscle) analysis has been processed both in the time and in the frequency domain by designing the digital signal processing system based on pentium PC and transputer (IMS 7805). The experiment have been performed in five normal subjects, and various parameters have been statistically tested and compare4 As a results, the effective parameters obtained for the evaluation of skeletal EMG electrical activity are turn analysis, MiTi, MiTa, IEMG, PDF in the time domain, and are mean frequency, median frequency, skewness, kurtosis, muscle fatigue slope in the frequency domain. The designed H/W and S/W in this study can be used effectively for the establishment of EMG data base and for clinical research.

  • PDF

Two-Channel EEG Analysis and Data Management Software (2-채널 뇌파분석 및 데이터 관리 소프트웨어)

  • Kang, D.K.;Kim, D.J.;Yoo, S.K.;Kim, S.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.193-194
    • /
    • 1998
  • This paper describes a multi-functional EEG (electroencephalogram) software. The software manages the patient's EEG data systematically and analyzes the signal and display the parameters on a PC monitor in real-time. Since the software provides various parameters simultaneously, user can observe patients multilaterally. Reference patterns of CSA and DSA can be captured and displayed on top of the monitor. And user can mark events of surgical operation or patient's conditions, so it is possible to jump to the points of events directly, when reviewing the recorded file afterwards. Many convenient functions are equipped and these are operated by mouse clicks.

  • PDF

"Dust, Ice, and Gas In Time" (DIGIT) Herschel observations of GSS30-IRS1

  • Je, Hyerin;Lee, Jeong-Eun
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.1
    • /
    • pp.50.1-50.1
    • /
    • 2013
  • As part of the DIGIT key program, we observed GSS30-IRS1, a Class I object located in Ophiuchus (d=125 pc), with Herschel-PACS. More than 70 lines were detected: CO lines of $J=14{\rightarrow}13$ to $41{\rightarrow}40$, several $H_2O$ lines of Eu=100 to 1500 K, 16 OH lines, and two atomic [OI] lines at 63 and 145 ${\mu}m$. All lines, except for [OI], were detected only at the central spaxel of $9.4^{\prime\prime}{\times}9.4^{\prime\prime}$ while the [OI] emission is extended along the NE-SW direction. One interesting feature in GSS30-IRS1 is that the continuum is extended beyond PSF, unlike the line emission. For detail analysis, we apply the non-LTE LVG model, RADEX as well as simple rotational diagrams to the detected line fluxes. We will discuss about the physical conditions around GSS30-IRS1, learned by the line flux analysis.

  • PDF

An introduction to the MMI system of strip casting Process (박판주조공정의 MMI 시스템 소개)

  • Joo, Moon-G.;Lee, D.S.;Kim, Y.H.;Kang, T.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.2778-2780
    • /
    • 2000
  • MMI system for strip caster 2 is described. It has been developed as a PC-based MMI system whose data is collected from the VME-based control system by ETHERNET. MMI elements that mimic the caster and its utilities are designed by using commercial program. In order to implement the UDP/IP communication in MMI, UDP/IP manager program with DDE that is a intercommunication protocol in MS-window is developed and connected with MMI mimics. Operator commands in MMI system are carried out immediately in VME system and the responses are displayed on MMI system. The developed MMI system has been proven to be convenient and stable through the operation of the past 5 years.

  • PDF

Design and Implementation of an Access Station/User Equipment Modem Diagnostic and Monitor Apparatus for High Speed Mobile System (초고속 무선 전송 시스템 기지국/단말 모뎀 진단/감시 장치의 설계 및 구현)

  • Jang, J.D.;Park, H.J.
    • Electronics and Telecommunications Trends
    • /
    • v.21 no.2 s.98
    • /
    • pp.170-183
    • /
    • 2006
  • 모뎀 진단/감시 장치(DM)는 기지국 DM 데이터 수집부와 단말 DM 데이터 수집부로각각 구분되어 DM 장치 내에서 기지국/단말 모뎀 플랫폼을 수용한다. 기지국 변조기, 기지국 동기, 기지국 채널 디코더, 기지국 복조기의 데이터는 기지국 DM 데이터 수집부에서 수집하고, 단말 변조기, 단말 동기, 단말 채널 디코더, 단말 복조기의 데이터는 단말 DM 데이터 수집부에서 수집하여 각각 수집된 데이터를 호스트 PC에서 분석하여 물리 계층 송수신 데이터 및 각종 통계 정보를 사용자 및 운용자가 확인할 수 있도록GUI로 화면에 표시해 준다. 모뎀 진단/감시 장치(DM)는 무선 전송 시스템(HM20)MIMO 구조 기지국/단말 모뎀의 물리 계층에 대한 상태 진단 및 감시 기능을 수행하여 모뎀 개발 과정에서 개발자에게 디버깅을 쉽게 하기 위한 장치로 사용된다. 또한 기지국 모뎀과 단말 모뎀의 유지 보수시 오류 발견을 위한 장치로 사용하기 위함이다.