• 제목/요약/키워드: Group Combustion

검색결과 164건 처리시간 0.031초

고용량 양극재료 개발을 위한 $LiNi_{1-y-z}(M_1)_y(M_2)_zO_2$의 합성과 전기화학적 특성 (Synthesis and Electrochemical Properties of $LiNi_{1-y-z}(M_1)_y(M_2)_zO_2$ for the Development of Cathode Materials with Large Capacity)

  • 송명엽
    • 한국수소및신에너지학회논문집
    • /
    • 제18권3호
    • /
    • pp.325-333
    • /
    • 2007
  • [ $LiNi_{0.995}Al_{0.005}O_2$ ], $LiNi_{0.990}Ti_{0.010}O_2$ and $LiNi_{0.0990}Al_{0.005}Ti_{0.005}O_2$ were synthesized with a combustion method by calcining in an $O_2$ stream at $750^{\circ}C$ for 36 h. The X-ray diffraction patterns of these synthesized samples showed $-NaFeO_2$ structure of rhombohedral system(space group; $R{\bar{3}}\;m$) with no evidence of impurities. Among these samples, $LiNi_{0.995}Al_{0.005}O_2$ exhibited comparatively high first discharge capacity and discharge capacity, and the best cycling performance. $LiNi_{0.995}Al_{0.005}O_2$ had the first discharge capacity of 165.2 mA h/g and a discharge capacity of 116.7 mA h/g at the 50th cycle at 0.1C rate. It showed the first discharge capacity of 141.0 mA h/g and a discharge capacity of 93.5 mA h/g at the 50th cycle at 0.5C rate.

연소 조건과 수종을 달리한 블랙카본의 물리화학적 성질 및 세슘의 흡착 특성 (Physicochemical and Adsorptive Properties of Black Carbon for Radioactive Cesium under Various Combustion Conditions and Tree Species)

  • 전소담;정성욱;한원식;장경순;신우식;황정환
    • 한국물환경학회지
    • /
    • 제33권6호
    • /
    • pp.689-695
    • /
    • 2017
  • This study was carried out to investigate the physicochemical and adsorptive characteristics of black carbon (BC) materials for cesium in case of severe nuclear accidents. The BC was prepared with a xylem of oak and pine trees incompletely combusted with different ramp rate and final temperature. Carbon (C), hydrogen (H) and oxygen (O) atomic ratios, BET, pore structure, and zeta potential were characterized for the produced BC. A low cesium concentration ($C_w{\approx}10^{-7}M$) was used for sorption batch experiments. The H/C and O/C ratios of BC decreased with the increase of final temperature, which indicates a carbonization of the wood materials regardless of ramp rate and tree species. However, SEM images showed different pore structures depending on tree species such as steric and plate-like for oak-BC and pine-BC, respectively. The greatest sorption distribution coefficients of $K_{d,Cs}{\approx}1,200{\sim}1,800L\;kg^{-1}$ were observed for the oak-BC produced at $400^{\circ}C$, while comparatively low $K_{d,Cs}$ < $100L\;kg^{-1}$ for pine-BC. In addition, the sorption capabilities of BC declined with the increase of combustion temperature up to $600^{\circ}C$, because high temperature destroyed surface functionalities with the rise of ash components in the BC. Therefore, the sorption processes of BC for radioactive cesium are predominantly controlled by final production temperature of BC as well as raw materials (e.g., tree species).

半圓周形 윤활홈을 갖는 저어널 베어링의 熱效果에 관한 연구 (A Study of Thermal Effects for a Half-Circumferential Grooved Journal Bearing)

  • Chun, Sang-Myung;Lalas, Demetrius P.
    • Tribology and Lubricants
    • /
    • 제6권1호
    • /
    • pp.36-51
    • /
    • 1990
  • A parametric study of the thermal effects of a half-circumferential grooved journal bearings under aligned and misaligned conditions has been carried out by solving numerically the coupled Reynolds and energy equation system. Five different sets of boundary conditions for the energy equation have been used which include mixing between recirculating oil and inlet oil and a contraction ratio for the cavitation region. The effects of changes of the inlet oil temperature and pressure, the wall temperature and the L/D ratio have also been examined. For the range of parameters found in internal combustion engines, the mixing effectiveness at the groove and the resulting final mixture temperature have been found to be as important as the wall temperature and the heat transfer rate. The variability of the temperature, though, has been shown to smooth out the peaks of both pressure and friction during misaligned condition Distributions of friction and pressure in the oil are also examined which may be useful in attempts to reduce friction without reducing load. Results for an axial grooved bearing are also presentsed for comparision purpose.

Mechanism of Piezoelectricity for Langasite Based on the Framework Crystal Structure

  • Ohsato, Hitoshi;Iwataki, Tsuyoshi;Morikoshi, Hiroki
    • Transactions on Electrical and Electronic Materials
    • /
    • 제13권2호
    • /
    • pp.51-59
    • /
    • 2012
  • Piezoelectric langasite crystals have superior properties such as high temperature performance and high quality Q and can be applied in combustion pressure sensors and surface acoustic wave (SAW) filters. Crystal growth, crystal structure and properties of langasite group are reviewed, and the mechanism of piezoelectricity of langasite is presented based on the crystal structure and deformation under high pressure. Finally, for the discovery of new piezoelectric materials, this paper presents the role of the framework, and recommends the search of framework crystal structure, because the characteristic of the mechanism exists on the framework of the crystal structure.

Occupational exposure to polycyclic aromatic hydrocarbons in Korean adults: evaluation of urinary 1-hydroxypyrene, 2-naphthol, 1-hydroxyphenanthrene, and 2-hydroxyfluorene using Second Korean National Environmental Health Survey data

  • Dong Hyun Hong;Jongwon Jung;Jeong Hun Jo;Dae Hwan Kim;Ji Young Ryu
    • Annals of Occupational and Environmental Medicine
    • /
    • 제35권
    • /
    • pp.6.1-6.15
    • /
    • 2023
  • Background: Polycyclic aromatic hydrocarbons (PAHs) are occupational and environmental pollutants generated by the incomplete combustion of organic matter. Exposure to PAHs can occur in various occupations. In this study, we compared PAH exposure levels among occupations based on 4 urinary PAH metabolites in a Korean adult population. Methods: The evaluation of occupational exposure to PAHs was conducted using Second Korean National Environmental Health Survey data. The occupational groups were classified based on skill types. Four urinary PAH metabolites were used to evaluate PAH exposure: 1-hydroxypyrene (1-OHP), 2-naphthol (2-NAP), 1-hydroxyphenanthrene (1-OHPHE), and 2-hydroxyfluorene (2-OHFLU). The fraction exceeding the third quartile of urinary concentration for each PAH metabolite was assessed for each occupational group. Adjusted odds ratios (ORs) for exceeding the third quartile of urinary PAH metabolite concentration were calculated for each occupational group compared to the "business, administrative, clerical, financial, and insurance" group using multiple logistic regression analyses. Results: The "guard and security" (OR: 2.949; 95% confidence interval [CI]: 1.300-6.691), "driving and transportation" (OR: 2.487; 95% CI: 1.418-4.364), "construction and mining" (OR: 2.683; 95% CI: 1.547-4.655), and "agriculture, forestry, and fisheries" (OR: 1.973; 95% CI: 1.220-3.191) groups had significantly higher ORs for 1-OHP compared to the reference group. No group showed significantly higher ORs than the reference group for 2-NAP. The groups with significantly higher ORs for 1-OHPHE than the reference group were "cooking and food service" (OR: 2.073; 95% CI: 1.208-3.556), "driving and transportation" (OR: 1.724; 95% CI: 1.059-2.808), and "printing, wood, and craft manufacturing" (OR: 2.255; 95% CI: 1.022-4.974). The OR for 2-OHFLU was significantly higher in the "printing, wood, and craft manufacturing" group (OR: 3.109; 95% CI: 1.335-7.241) than in the reference group. Conclusions: The types and levels of PAH exposure differed among occupational groups in a Korean adult population.

탄화도별 발전연료의 자연발화 특성 평가 (Spontaneous Combustion of Various Fuels of Carbonization Rank)

  • 김재관;박석운;정재혁;신동익;홍준석;홍진표
    • 에너지공학
    • /
    • 제26권3호
    • /
    • pp.78-89
    • /
    • 2017
  • 미분탄화력발전소에서 사용되는 각종 발전연료의 탄화도에 따른 발열개시온도(CPT;Cross Point Temperature), 발화온도(IT; Ignition temperature) 및 발화온도 승온속도(CPS;Cross Point Slope)는 전기로 내부에 설치된 백금망에 $74{\mu}m$이하 입도의 시료를 넣고 공기분위기, $25^{\circ}C$에서 $600^{\circ}C$까지의 승온조건에서 평가하였다. 발열개시온도 및 발화온도는 탄화도에 대한 의존성이 크지 않은 반면, 발화온도 승온속도는 탄화도에 크게 의존하는 것으로 나타났다. 탄화도가 낮은 우드펠렛의 발화온도 승온속도는 $20.995^{\circ}C/min$으로 기장 높은 자연발화성을 가지며, 아역청 KIDECO탄은 $15.370^{\circ}C/min$인 반면, 가장 높은 탄화도를 가지는 석유코크스는 $20.950^{\circ}C/min$로 나타냈다. 자연발화 경향성은 석탄 표면의 산화반응에 주요한 변수로서 작용하는 휘발분 함량 및 산소관능기의 농도 뿐만 아니라 촤의 비표면적, 정압몰비열이 높을수록 증가하는 것으로 확인되었다.

대구지역 공중이용시설의 실내 $\cdot$ 외 공기 중 기준성오염물질의 농도 (Concentrations of Criteria Pollutants in Indoor and Ambient Air of Public Facilities in Taegu Area)

  • 송희봉;민경섭;한개희;김종우;백성옥
    • 한국대기환경학회지
    • /
    • 제12권4호
    • /
    • pp.429-439
    • /
    • 1996
  • A comprehensive air quality monitoring was carried out in this study to investigate the concentrations of criteria air pollutants in indoor and outdoor air of public facilities in Taegu area. Four different kinds of public facilities were seleced as sampling sites, which are underground stores, stations & terminals, general hospitals, and department stores. Each group of the public facilities was consisted of three different sampling sites. As a consequence, a total of 12 different sampling sites were surveyed throughout this study. Sampling was conducted simultaneously indoors, three times per day (in the morning, afternoon, and evening) and four times per year (spring, summer, fall, and winter) at each sampling site during the period of October 1994 to July 1995. A range of criteria pollutants were measured in order to obtain a broad profile of indoor and ambient air quality, including total suspended particles (TSP), carbon monoxide (CO), carbon dioxide ($CO_2$), formaldehyde (HCHO), sulfur dioxide ($SO_2$), and nitrogen dioxide ($NO_2$). In addition, temperature, relative humidity, and air current were measured on site together with those air pollutants. Results of this study indicated that the indoor levels of TSP, CO, $SO_2, and NO_2$ appeared to be generally higher in stations/terminals and underground stores than those in department stores and hospitals. However, HCHO and $CO_2$ were found to have higher levels in the department stores and hospitals than other places, indicating that the effects of indoor sources for these pollutants are significantly different from other combustion related pollutants such as TSP, CO, and $SO_2$. It was also found that there are marked seasonal and daily variations both in indoor and outdoor air quality. In general, combustion related pollutants such as CO, $SO_2$ and $NO_2$ showed a typical pattern of higher levels in winter than insummer, and also higher in the morning and/or in the evening than in the afternoon. However, the seasonal and daily patterns of HCHO appeared to be opposite to the combustion related pollutants, i.e., higher both in summer and in the afternoon, implying the effect of temperature on the volatilization from indoor sources of HCHO. Results of correlation analyses between indoor and outdoor air quality also indicated that the effects of outdoor sources on the indoor levels of TSP, $SO_2$, CO, and $NO_2$ and much significant, whilst no significant correlations between indoor and outdoor levels were found for HCHO and $CO_2$.

  • PDF

착화탄 연소에 의한 가스 중독 환자에서 혈중 중금속 농도의 영향에 대한 예비연구 (Effect on blood heavy metal concentration in gas poisoning by combustion of ignition coal: Pilot study)

  • 이상환;이준철;조용일;고벽성;오재훈;강형구
    • 대한임상독성학회지
    • /
    • 제19권2호
    • /
    • pp.127-132
    • /
    • 2021
  • Purpose: It is known that the most common cause of gas poisoning in Korea is suicide attempts by burning ignition coals. Ignition coals are made from waste wood, and studies have been reported that heavy metals are emitted when this coal is burned. However, there was no study on how much heavy metal poisoning occurs in the human body through this, so this study was planned to find out whether the concentration of heavy metals in the blood increased in patients exposed to ignition coal combustion. Methods: From April 2020 to April 2021, blood lead, mercury, and cadmium concentrations were investigated in carbon monoxide poisoning patients who visited one regional emergency medical center in Seoul, and their association with exposure time, source of poisoning, and rhabdomyolysis were investigated. Results: During the study period, a total of 136 carbon monoxide poisoning patients were tested for heavy metals, and 81 cases of poisoning by ignition coal were reported. When comparing poisoning caused by combustion of ignition coal and other substances, there was no difference in the concentrations of lead, mercury, and cadmium in the blood, and there was no difference in the number of patients above the reference range. However, the patients exposed to more than 5 hours of ignition coal gas exposure are more frequent than those in the group less than 5 hours in lead (51.4% vs. 23.9%, p=0.012). Conclusion: Compared to poisoning with other combustible substances, the blood concentration of lead, mercury, and cadmium does not increase further in patients with gas poisoning by ignition coal. However, prolonged exposure may result in elevated levels of lead.

제품별 직접구가 흰쥐의 소장수송능에 미치는 영향 (Effects of Different Company's Moxa Cautery on Small Intestinal Motility in Rats)

  • 유윤조
    • 동의생리병리학회지
    • /
    • 제23권6호
    • /
    • pp.1332-1340
    • /
    • 2009
  • Moxa-combustion therapy makes use of heat stimulus and chemicals result form when cauterize the skin with moxa cones to medical cares. Despite an extensive evidence-base guiding the selection of stimulation parameters and attributes of subject, little methodologically research regarding the attributes of moxa cautery in need to provide effective stimulation. To determine moxibustion's effects of the three different moxa cautery made by three different company(as A, B, C), the small intestinal motility in rats were observed after moxibustion at ST36. Under anesthesia, each intensities(1, 5, 10 times), two regions(left and right at ST36) and a quantity(as number of 1, 5, 10 times at once) were applied to the groups divided with sex. In each intensities groups, the A product made increase with 5, 10 times in male and female group. The B and C product made increase with 10 times in male group and the B product made increase with 1, 5, 10 times and the C product made increase with 5 times in female group. In two regions(left and right at ST36) groups, the A and C product made increase with 1(right), 5(right) times and the B product made increase with 1(left), 10(left), 10(right) times in male group. In female group, the A product made increase with 5(left), 5(right), 10(right) times and the B product made increase with 1(left), 10(left), 10(right) times and the C product made increase with 5(left), 10(left) times. In a quantity(as number of 1, 5, 10 times at once) groups, the A and B product did not show any changes but the C product made increase with a quantity of 10 times in male group. In female group, The B product made increase with a quantity of 1 times and the C product made increase with a quantity of 5 times, but the A product did not show any changes. Three different moxa cautery made by three different company made differents result in each group divided with sex. With these results, it was suggested that we should consider the a process of manufacture and moxa cautery's quality for the adequate value of moxibustion.

폐기물 소각시설 배가스에서의 수은 배출특성 (The Characteristics of Mercury Emission from Municipal Solid Waste (MSW) Incinerator Stack)

  • 이한국
    • 한국환경보건학회지
    • /
    • 제30권5호
    • /
    • pp.378-387
    • /
    • 2004
  • This study was carried to investigate the emission characteristics of mercury from domestic and industrial MSW (municipal solid waste) incinerator stacks. The mercury concentration levels of flue gas from 32 MSW incinerators stacks selected were above the criteria level ($5{\mu}g/S\;m^3$). MSWI facilities exceeding the criteria levels in Korea are due to the poor units comparison of combustion chamber(CC)-cyclone(CY)-stack. So, the mercury from MSW incinerators stack were suspected to contaminate the natural system unless the MSW incinerators were properly controlled. Mean-while, the relationship between mercury concentration and temperature of flue gas in MSW incinerator stacks were examined at two temperature ranges (Group A : $29.85{\sim}327.63^{\circ}C$, Group B : $446.9{\sim}848.15^{\circ}C$). The mercury concentration in flue gas with high temperature range was higher than that of flue gas with low temperature rage. This mean that the temperature of flue gas plays an important role in mercury control in MSW incinerator. The emission characteristics oi mercury was also evaluated by using the correlation matrix between the mercury and NOx, $PM_{10}$, moisture (MO.) at both low temperature and high temperature flue gas ranges. The mercury concentration was mainly affected by NOx, $PM_{10}$. moisture (MO.) at low temperature range, while the mercury concentration at high temperature flue gas was mainly affected by NOx, moisture (MO.). From these results, it was suggested that the temperature of cooling system and the air pollution control device should be properly regulated in order to control mercury of flue gas in MSWI incinerator.