접지전류의 주파수에 따른 수직 접지전극 주변에서 전위간섭 영향 분석 (An Analysis of Potential Interference Effects in the Vicinity of Ground Rod Depending on Frequency of Ground Currents)

  • 이복희;조용승;최종혁;양순만
    • 조명전기설비학회논문지
    • /
    • 제25권12호
    • /
    • pp.88-93
    • /
    • 2011
  • When the ground current is injected into the adjacent ground electrode, the potential interference is caused between ground electrodes, the ground potential interferences have been largely studied with power frequency fault currents. Many attempts to find the frequency-dependent grounding impedance report that the high frequency grounding impedance is very different with the ground resistance. This paper presents experimental data on the frequency-dependent potential interference effects in the vicinity of ground rod. The ground potential rises around the test ground rod of 4 or 6[m] were measured and discussed. As a result, the ground potential rises and potential interference factor are decreased with decreasing the grounding impedance. It was found that the lowering of grounding impedance is critical to reduce the ground potential interference effects.

봉형 접지전극의 시설깊이에 따른 대지전위분포 (Ground Potential Distribution Associated with the Buried Depth of Ground Rod)

  • 이복희;엄주홍;안창환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.2068-2070
    • /
    • 2000
  • Ground potential rise is a vital part of personal safety, this paper presents the ground potential rise distribution induced by a ground rod. The experiments were conducted with the AC square wave currents according to the buried depth of ground rod. The ground potential is significantly varied in the vicinity of ground rod and the ground potential distribution is flat and few with increasing the buried depth of ground rod.

  • PDF

침술 효과의 객관화를 위한 접지조건에 따른 경락전위분석 (Analysis of Meridians Potential as Ground Condition for Objectification of Acupuncture Effect)

  • 이용흠;이균정;김은근;김한성;신태민
    • 전기학회논문지
    • /
    • 제56권2호
    • /
    • pp.436-441
    • /
    • 2007
  • Background: As patients are positioned at insulated bed and practitioner are positioned at insulated floor or shoes, it could be a cause of lessening effect in acupuncture practice. We investigated how Ground connection could influence on the electrical meridian potential between practitioner and patient during acupuncture practice. Method: We treated 30 normal healthy subjects with acupuncture and measured changes in the electrical potential between the stomach meridian points ST-39 and ST-37 in response to light touch after insertion of a needle at ST-36. At first, we stimulated needle and measured electrical potentials for non ground, patient ground only, practitioner ground only, all ground, respectively. Result: All ground subject elicited positive mean potential $44.6{\pm}19.2{\mu}V$ and showed $181.4{\pm}59.7{\mu}V$ peak to peak potential. practitioner ground only showed negative mean potential $-51.5{\pm}9.3{\mu}V\;and\;367.4{\pm}27.8{\mu}V$ of peak to peak potential. Patient ground only revealed no mean potential as $2.9{\pm}1.3{\mu}V,\;16.4{\pm}11.9{\mu}V$ of peak to peak potential. All ground showed no mean potential as $1.6{\pm}0.7{\mu}V,\;3.3{\pm}1.9{\mu}V$ of peak to peak potential. respectively.

-침술효과 객관화를 위한 연구- 접지와 절연조건이 경락전위에 미치는 영향 (Influence on Meridians Electric Potential for Electrical Ground and Insulation)

  • 이용흠;이균정;김은근;김한성;신태민
    • 한국정보통신학회논문지
    • /
    • 제10권12호
    • /
    • pp.2243-2250
    • /
    • 2006
  • When a patient is positioned at insulated bed and practitioner is positioned at insulated floor, that condition could be a cause of lessening effect in acupuncture practice. We investigated how Ground connection and Insulation could influence on the electrical meridian potential between practitioner and patient during acupuncture practice. We treated 30 normal healthy subjects with acupuncture and measured changes in the electrical potential between the stomach meridian points ST-39 and ST-37 in response to light touch after insertion of a needle at ST-36. At first, we stimulated non-insulated needle and measured electrical potentials for non ground, patient ground only, practitioner ground only, all ground respectively. Then we used insulated needles and measured same as above. Non-insulated all ground subject elicited positive mean potential $44.6{\pm}19.2{\mu}V$ and showed $181.4{\pm}59.7{\mu}V$ peak to peak potential. Practitioner ground only showed negative mean potential of $51.5{\pm}9.3{\mu}V$ and $367.4{\pm}27.8{\mu}V$ of peak to peak potential. Patient ground only revealed no mean potential of $2.9{\pm}1.3{\mu}V$, $16.4{\pm}11.9{\mu}V$ of peak to peak potential. All ground showed no mean potential of $1.6{\pm}0.7{\mu}V$, $3.3{\pm}1.9{\mu}V$ of peak to peak potential. In case of Insulated condition, there elicited no mean potential. Non ground and Practitioner only showed weak value of peak to peak potential as $7.8{\pm}2.6{\mu}V$ and $8.4{\pm}2.5{\mu}V$ each. But patient only and all ground showed no potential as $4.7{\pm}2.2{\mu}V$, $3.4{\pm}2.2{\mu}V$, respectively. Therefore, Ground connection modulate the energy transfer course between practitioner and patient. Insulation block energy transfer but static electrical impulse between practitioner and patient.

전류 및 전위 보조전극을 수직으로 배치하는 전위강하법을 이용한 접지저항의 측정 (Measurement of the Ground Resistance using the Fall-of-Potential Method with the Vertically-placed Current and Potential Auxiliary Electrodes)

  • 이복희;김기복;김유하
    • 조명전기설비학회논문지
    • /
    • 제26권3호
    • /
    • pp.53-60
    • /
    • 2012
  • The fall-of-potential method is commonly used in measuring the ground resistance of large-scaled grounding system and the current and potential auxiliary electrodes are horizontally arranged. Because the distances between the ground grid to be tested and auxiliary electrodes are limited in downtown areas, it is very difficult to measure accurately the ground resistance of large-scaled grounding system. In this paper, the fall-of-potential method of measuring the ground resistance with the vertically-placed current and potential auxiliary electrodes was examined and discussed. The validity and good accuracy of the proposed method of measuring the ground resistance were confirmed through various simulations and actual tests carried out in uniform and two-layer soil structures.

대지구조에 따른 접지봉 주번의 대지표면전위분포 (Ground Surface Potential Distribution near Ground Rod Associated with Soil Structures)

  • 이복희;정현욱;백영환
    • 조명전기설비학회논문지
    • /
    • 제21권1호
    • /
    • pp.142-147
    • /
    • 2007
  • 본 논문은 대지구조와 접지봉의 매설깊이에 따른 대지표면의 전위상승에 대해서 기술하였다. 대지표면의 전위상승에 따른 인체의 감전사고의 저감에 관한 기초적 자료를 제안하기 위해서 접지봉 부근에서의 대지표면전위를 계산하고 측정하였다. 접지봉 부근의 대지표면전위상승은 대지구조에 크게 의존하며, 매설깊이가 깊어질수록 낮아졌다. 대지표면전위상승은 접지봉의 직상부에서 최대이었으며, 측정결과는 접지해석프로그램으로 계산한 결과와 잘 일치하였다.

전위간섭을 기초로 한 병렬 접지봉의 합성접지임피던스의 분석 (An Analysis on Resultant Ground Impedance Based on the Potential Interference Of Parallel Ground Rods)

  • 이복희;성창훈;양순만
    • 조명전기설비학회논문지
    • /
    • 제25권12호
    • /
    • pp.107-112
    • /
    • 2011
  • Multiple ground rods are commonly used to obtain the low ground impedance, but they will not reduce the ground impedance unless the spacings between the ground rods are sufficient. This paper presents the experimental results of frequency-dependent resultant ground impedance of two ground rods in parallel. The resultant ground impedance of two ground rods in parallel were measured as functions of the spacing and length of ground rods and the frequency of test currents and were discussed based on the potential interferences. As a consequence, the frequency-dependent ground impedance of single ground rod and two combined ground rods give capacitive. It was found that the effect of potential interference on the ground impedance is directly associated with the frequency-dependent ground impedance and is strong in low frequency. Also, in order to reduce the increasing rate of resultant ground impedance of two ground rods due to potential interference to within 10(%), two ground rods in parallel will be placed over one rod length apart.

병렬로 시공된 수직 접지전극의 합성접지임피던스의 주파수의존성 분석 (An Analysis of the Frequency-Dependent Resultant Ground Impedance of Vertical Ground Electrodes Installed in Parallel)

  • 이복희;조성철;성창훈
    • 조명전기설비학회논문지
    • /
    • 제26권2호
    • /
    • pp.99-105
    • /
    • 2012
  • This paper deals with the experimental results of the frequency-dependent resultant ground impedance of vertical ground electrodes installed with a regular n-polygon. In order to propose an effective method of installing the vertically-driven multiple ground electrodes used to obtain the low ground impedance, the resultant ground impedance of ground electrodes installed with a regular n-polygon were measured as functions of the number of ground electrodes and the frequency of test currents and the results were discussed based on the potential interferences among ground electrodes. As a consequence, the effect of potential interference on the resultant ground impedance of vertical ground electrodes is frequency-dependent and it is significant in the low frequency of a few hundreds [Hz]. The resultant ground impedance of multiple vertical ground electrodes is not decreased in linearly proportion to the number of ground electrodes due to the overlapped potential interferences. Also the distributed-parameter circuit model considering the potential interference, the frequency-dependent relative permittivity and resistivity of soil was proposed. The simulated results of the frequency-dependent resultant ground impedance of multiple vertical ground electrodes are in good agreement with the measured data.

반구형 실험모델을 이용한 대지표면 전위상승의 분석 (Analysis of the Ground Surface Potential Rise using a Hemisphere-Shaped Test Model)

  • 유재덕;조용승;이복희
    • 조명전기설비학회논문지
    • /
    • 제24권12호
    • /
    • pp.208-213
    • /
    • 2010
  • This paper deal with an analysis of the ground surface potential profiles using a hemispherical scaled-model. Because it is very difficult to draw valid conclusions concerning a general grounding problem from actual field data, scale model tests can be used to determine the ground surface potential profile around the grounding electrodes according to the configuration of grounding electrodes. In this work, a hemispherical vessel with a diameter of 1,100 [mm] was employed to simulate uniform soil and CDEGS program was employed to compare the measured and simulated results. As a result, the ground surface potential around the grounding electrode was significantly raised and the ground surface potential at the just upper point of ground electrode particularly was higher than other points. The ground surface potential of counterpoise was higher than other grounding electrodes such as mesh and grounding rods and the ground surface potential strongly depends on the frequency responses of grounding electrodes. Also the results measured with the small-sized model were in reasonably agreement with the data obtained from simulation.

측정전류전이법을 이용한 운전중인 접지시스템의 접지저항 측정 (Measurements of the Ground Resistance using the Test Current Transition Method in Powered Grounding Systems)

  • 이복희;엄주홍;김성원
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권8호
    • /
    • pp.347-353
    • /
    • 2002
  • This paper presents an accurate method for measuring the ground resistance in powered grounding system. Most of substations and electric power equipments are interconnected to an extensive grounding network of overhead ground wires, neutral conductors of transmission lines, cable shields, and etc. The parasitic effects due to circulating ground currents and ground potential rise make a significant error in measuring the ground resistance. The test current transition method was proposed to reduce the effects of stray ground currents, ground potential rise and harmonic components in measurements of the ground resistance for powered grounding systems. The instrumental error of the test current transition method is decreased as the ratio of the test current signal to noise(S/N) increases. It was found from the test results that the proposed measuring method of the ground resistance is more accurate than the conventional fall-of-potential method or low-pass filter method, and the measuring error was less than 3[%]when S/N is 10.