• 제목/요약/키워드: Ground behavior

검색결과 1,853건 처리시간 0.025초

풍화암에 근입된 그라운드 앵커의 인발거동 연구 (A Study on the Pullout Behavior of Ground Anchored in Weatherd Rock)

  • 박병수;정길수;전상현;유남재
    • 산업기술연구
    • /
    • 제26권A호
    • /
    • pp.109-117
    • /
    • 2006
  • This study is an numerical study of predicting the behavior of anchor embedded in weathered rocks, subjected to uplift loads, about ultimate pullout capacity and the failure mechanism. Factors influencing the behavior of anchors were investigated by reviewing the data about in-situ anchor tests performing numerical modelling with changing the bondage length of anchor, diameter of anchor body and diameter of tenden, and by Correlations between those factors were evaluated to apply them to predict the behavior of anchors. As results of numerical analysis, a linear relationship between bondage length, diameter of anchor body and diameter of tenden with ultimate pullout capacity was obtained on the one hand, from the result of numerical analysis changing the Young's modulus of weathered rock, this parameter was found to inflence to load-displacement and ultimate pullout capacity within the range of 10%, which was mot so significant to affect.

  • PDF

충전율에 따른 폐광산 채굴적 공동의 변위거동에 관한 연구 (Study on Displacement Behavior of Abandoned Mine Goaf Cave According to Filling Factor)

  • 김동락;서인식
    • 한국산업융합학회 논문집
    • /
    • 제14권4호
    • /
    • pp.151-156
    • /
    • 2011
  • The domestic mine development community the countermeasure establishment is insufficient about ground sinkage, not only the mine which is a in line is partial from the mine of the most which has become the rest mine and abandoned mine or the index sinkage occurs. The ground sinkage which occurs from the abandoned mine area most after operation is stopped, a long time passes and accurately predicts an occurrence location and a time with the residual sinkage which occurs, is difficult. Underground goaf of the abandoned mine and the closed shaft When considering the potentiality which causes the instability of ground, is a possibility of reaching a damage in the ground infrastructure or life. The underground shaft which is formed specially with mine development and goaf operates with the obstacle factor in the development project of the mine area, the ground sinkage which is caused by with sinkage, operates with the large safety accident occurrence factor where the important infrastructure of the railroad, road, residential area etc. is damaged. Therefore, In this paper, the goaf cave of the abandoned mine area, for the displacement behavior according to the filling factor of the material is to analyze the numerical analysis.

Sensitivity analysis of variable curvature friction pendulum isolator under near-fault ground motions

  • Shahbazi, Parisa;Taghikhany, Touraj
    • Smart Structures and Systems
    • /
    • 제20권1호
    • /
    • pp.23-33
    • /
    • 2017
  • Variable Curvature Friction Pendulum (VCFP) bearing is one of the alternatives to control excessive induced responses of isolated structures subjected to near-fault ground motions. The curvature of sliding surface in this isolator is varying with displacement and its function is non-spherical. Selecting the most appropriate function for the sliding surface depends on the design objectives and ground motion characteristics. To date, few polynomial functions have been experimentally tested for VCFP however it needs comprehensive parametric study to find out which one provides the most effective behavior. Herein, seismic performance of the isolated structure mounted on VCFP is investigated with two different polynomial functions of the sliding surface (Order 4 and 6). By variation of the constants in these functions through changing design parameters, 120 cases of isolators are evaluated and the most proper function is explored to minimize floor acceleration and/or isolator displacement under different hazard levels. Beside representing the desire sliding surface with adaptive behavior, it was shown that the polynomial function with order 6 has least possible floor acceleration under seven near-field ground motions in different levels.

침하저감효과를 위한 고강도 지오그리드 보강Stone Column 공법에 관한 연구 (A Study on the Geogrid Reinforced Stone Column System for Settlement Reduction Effect)

  • 박시삼;이훈연;유충식;이대영;이부락
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.838-845
    • /
    • 2006
  • Recently construction work in Korea, demands of favorable condition ground had been increased with industrialization acceleration and economic growth. However, because of limited land space, it was so hard to ensure favorable condition grounds that construction work proceeds until soft ground area on plans of road, railroad and industrial complex. In this case, soft ground improvement was required such as a stone column method. Stone column method, making a compaction pile using crushed stone, is a soft ground improvement method. However, stone column method is difficult to apply to the ground which is not mobilized enough lateral confine pressure because no bulging failure resistance. Hence, in present study, evaluates the stone columns reinforced by geogrid for settlement reduction and wide range of application of stone columns. Triaxial compression tests were conducted for evaluation which is about behavior characteristics of stone column on replacement rate. Then, 3-dimensional numerical analysis were conducted for application of stone column reinforced by geogrid as evaluate behavior characteristics and settlement reduction effect of stone column reinforced by geogrid on reinforcing depth change of geogrid.

  • PDF

병렬 쉴드터널의 이격거리와 적용사례 (Distance between the Parallel Shield tunnel and Application)

  • 곽철홍;김재영;김동현;이두화;이승복;김응태;심재범
    • 한국터널공학회:학술대회논문집
    • /
    • 한국터널공학회 2005년도 학술발표회 논문집
    • /
    • pp.225-232
    • /
    • 2005
  • The construction of parallel tunnel by using the shield TBM method was increased recently. Accordingly the application and the propriety of the parallel shield TBM tunnels were studied through domestic and foreign construction cases herein. Also the behavior of tunnel structure and ground was evaluated by a numerical analysis with various ground conditions and the distance between the parallel tunnels. As a result, it was concluded that a deep investigation as well as a ground reinforcement was required with a ratio(L/D) of the distance between the parallel tunnels(L) to tunnel outer diameter(D) less than 0.5 because the Interference phenomenon was expected to occur. And the appropriateness of the application method of parallel shield TBM tunnel was validated through the 2-dimensional numerical analysis simulated the process of excavation after the ground reinforcement in the starting area of the OOO construction site with the ratio(L/D) of 0.35.

  • PDF

점성을 고려한 PBD 타설 연약점토지반의 3차원 압밀해석 (3-Dimensional Consolidation Analysis Considering Viscosity on Soft Clay Ground improved by Plastic Board Drain)

  • 유승경;한중근;조성민;김지용
    • 한국지반신소재학회논문집
    • /
    • 제4권4호
    • /
    • pp.39-46
    • /
    • 2005
  • 점성을 고려한 연약점토지반의 압밀거동을 파악하기 위해 플라스틱보드드레인(PBD)에 의해 개량된 연약점토지반의 압밀거동에 대한 탄점소성 3차원 수치해석을 실시하였다. 본 연구에서 사용한 수치해석기법의 적용성은 기존에 실시한 모형실험의 결과와 수치해석의 결과를 비교함으로써 검증하였다. 수치해석 결과로부터 연약점토지반의 침하 및 과잉간극수압의 소산거동, 유효응력증분의 변화 특성을 파악할 수 있었으며, 기존의 일차원 압밀해석 결과와의 비교를 통해 개량지반에서 발생하는 이차압밀특성을 평가하였다.

  • PDF

팽이기초공법(Top-Base Method)의 하중-침하량 분석 (Load-Settlement Characteristics of Concrete TOP-BASE Foundation on Soft Ground)

  • 김재영;정상섬;이재환
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 춘계 학술발표회
    • /
    • pp.210-221
    • /
    • 2009
  • A new foundation type which is called Top-Base method has been used frequently in engineering practices in Korea. In this study, the settlement behavior of concrete Top-Base foundation on soft ground is investigated since the consolidation settlement of the embedding depth and the effect of footing dimensions are not included in current Korean criterion (2007). To obtain detailed information, the model tests of the Top-Base foundation are performed using the PLAXIS 3D finite element analysis. It is shown that in-situ measurements and finite element analysis of the behavior of foundations indicate that consolidation settlement is reduced up and bearing capacity of the foundation increases up to 50%~100%, compared to the primary non-treated ground. Based on this study, it is found that the Top-Base foundation prevents the lateral deformation of soft ground and reduces its negative dilatancy to the surface settlement, and that the foundation creates rather uniform stress distribution under it to increase its bearing capacity. It is also found that the total settlement of Top-Base foundation was highly dependent on the consolidation settlement and footing configurations.

  • PDF

연직배수재가 타설된 지반의 복합통수능 해석 (Composite Discharge Capacity Analysis of Vertical Drain Installed in Ground)

  • 김창영;곽노경;이송
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.1167-1174
    • /
    • 2008
  • Vertical drain method, which is one of the soft ground improvement methods, shorten s drain path to accelerate consolidation process and is applied in many sites. At a recent, composite discharge capacity experiment that analyze discharge amount by consolidation behavior with overburden pressure of soft ground in laboratory, simulates similarly with actuality. Geotechnical engineering problems such a s soft ground improvement are solved by numerical analysis by development of computer and numerical analysis techniques. Numerical analysis does that result is contrary by user's inexperience for choice of constitution model and application of analysis method. Therefore, this thesis experiments on composite discharge capacity test and study discharge capacity of drain and consolidation behavior of soft ground installed prefabricated vertical drain boards. Also, This thesis studied reasonable input parameters and constitution model by compare results of composite discharge capacity test and numerical analysis using PLAXIS that is 2D finial element numerical analysis program.

  • PDF

표층보강 초연약지반 거동의 예측 방법 개발 (Development of Prediction Method for Behavior of Reinforced Very Soft Clay)

  • 이종선;이철호;유승경;최항석
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 세계 도시지반공학 심포지엄
    • /
    • pp.482-491
    • /
    • 2009
  • In this study, the mechanical behavior of very soft ground that is reinforced on the surface has been investigated with the aid of a series of numerical analyses. Key material properties of each dredged soft ground, reinforcement and backfill sand mat have been parametrically estimated in the numerical analysis. Along with the result of the study previously performed, a series of in-situ loading conditions and settlement exerted by surface reinforcing operation by construction vehicles has been numerically simulated. These result have been used to evaluate the limit bearing capacity for the unreinforced and reinforced soft ground. Also, the results of the numerical analysis obtained in this research were compared with Yamanouchi's empirical correlation for the limit bearing capacity. Engineering charts listed in this paper for estimating the limit bearing capacity provide field engineers with preliminary design tool for surface reinforcement of very soft ground.

  • PDF

대형 봉상 접지전극의 뇌 임펄스 특성 (Lightning impulse characteristics of large-scale ground rods)

  • 이복희;장근철;이동문;정동철;이승칠;안창환;정용기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1849-1851
    • /
    • 2003
  • To obtain a low ground resistance in high resistivity soil, long vertical ground rods are often used. However, if the lightning current or fault current with high frequency flow into the grounding system, the ground impedance is significantly increased because of the inductive behavior. This paper presents how the impulse current works on the long vertical ground electrodes. The different shape of current was impressed between ground rods and auxiliary electrode by using impulse generator and the ground impedance was calculated from the ground potential rise.

  • PDF