• Title/Summary/Keyword: Ground Resistance

Search Result 1,049, Processing Time 0.025 seconds

Effect of Incidence Angle of Current on the Hydraulic Resistance Capacity of Clayey Soil (흐름의 입사각이 점성토 지반의 수리저항성능에 미치는 영향)

  • Kim, Young-Sang;Han, Byung-Duck;Kang, Gyeong-O
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.24 no.1
    • /
    • pp.26-35
    • /
    • 2012
  • Until now, study on the hydraulic resistance characteristics of the ground at the river and the ocean current has been focused on the behavior under uni-directional flow without the direction change of flow. However, recent research result shows that scour rate which were measured under the bi-directional flow was much higher than those measured under uni-directional flow for both fine grained and coarse soil. Since the direction of inflow and return flow at the shore, where the structure will be constructed, is not always $180^{\circ}$, effect of the incidence angle on the hydraulic resistance capacity of the ground should be examined. Using the improved EFA which can consider the direction change of flow, hydraulic resistance capacities of the artificially composed clayey fine grained soil and clayey sandy soil under $0^{\circ}$, $90^{\circ}$, $135^{\circ}$, $180^{\circ}$ flow angle of incidence were assessed. Test result shows that hydraulic resistance capacity decreases and scour rate increase with the increase of the incidence angle between inflow and return flow. For the low consolidation pressure condition, hydraulic resistance capacity of the fine grained soil decreases rapidly. While the hydraulic resistance capacity of the coarse grained soil decreases more rapidly than fine grained soil under high consolidation pressure. Eventually since the larger the incidence angle between inflow and return flow, the larger the scour rate. Hydraulic resistance capacity under bi-directional flow($0^{\circ}{\longleftrightarrow}180^{\circ}$) should be examined for the design purpose.

A Study on Resistance of Chloride Ion Penetration in Ground Granulated Blast-Furnace Slag Concrete (고로슬래그 미분말 콘크리트의 염화물 침투 저항성에 관한 연구)

  • Song, Ha-Won;Kwon, Seung-Jun;Lee, Suk-Won;Byun, Keun-Joo
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.3
    • /
    • pp.400-408
    • /
    • 2003
  • Chloride ion inside concrete destroys the so-called passive film surrounding reinforcing bars inside concrete so that the so-called salt attack accelerates corrosion which is the most critical factor for durability as well as structural safety of reinforced concrete structures. Recently, as a solution of the salt attack, the ground granulated blast-furnace slag(GGBFS) have been used as binder or blended cement more extensively. In this paper, characteristics of chloride ion diffusion for the GGBFS concrete, which is known to possess better resistance to damage due to the chloride ion penetration than ordinary portland cement(OPC) concrete possesses, are analyzed and a chloride ion diffusion model for the GGBFS concrete is proposed by modifying an existing diffusion model for the OPC concrete. The proposed model is verified by comparing diffusion analysis results using the model accelerated chloride penetration test results for concrete specimens as well as field test results for an RC bridge pier. Then, an optimal resistance condition to chloride penetration for the GGBFS concrete is obtained according to degrees of fineness and replacement ratios of the GGBFS concrete. The result shows that the GGBFS concrete has better resistance to chloride ion penetration than OPC concrete has and the resistance is more affected by the replacement ratio than the degree of fineness of the GGBFS.

Myth of 61.8% rule and the practical application notices (접지저항 측정의 61.8%법칙 적용의 맹점과 현실적 접근 방법)

  • Lee, Sang-Mu;Cho, Pyung-Dong
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2005.08a
    • /
    • pp.259-262
    • /
    • 2005
  • Ground resistance measurement is an elementary technique for the evaluation of grounding system. There are main environmental factors to consider for correct measurement but the problem is that it is practically most cases to measure ground resistance unable to know the factors. This paper presents a methodology toward true value of resistance in the unknown circumstances, utilizing the defined term 'variation rate' of potential difference curve appearing in the distance to a current probe as in the three point fall-of-potential method which comprises the characteristics of environmental factors. This methodology is a induced result from the previous demostrated studies.

  • PDF

Resistance against Chloride Ion and Sulfate Attack of Cementless Concrete (무시멘트 콘크리트의 염소이온 침투 및 황산염 침투 저항성)

  • Lee, Hyun-Jin;Bae, Su-Ho;Kwon, Soon-Oh;Lee, Kwang-Myong;Jeon, Jun-Tai
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.6 no.2
    • /
    • pp.63-69
    • /
    • 2015
  • It has been well known that concrete structures exposed to chloride and sulfate attack environments lead to significant deterioration in their durability due to chloride ion and sulfate ion attack. The purpose of this experimental research is to evaluate the resistance against chloride ion and sulfate attack of the cementless concrete replacing the cement with ground granulated blast furnace slag. For this purpose, the cementless concrete specimens were made for water-binder ratios of 40%, 45%, and 50%, respectively and then this specimens were cured in the water of $20{\pm}3^{\circ}C$ and immersed in fresh water, 10% sodium sulfate solution for 28 and 91 days, respectively. To evaluate the resistance to chloride ion and sulfate attack for the cementless concrete specimens, the diffusion coefficient for chloride ion and compressive strength ratio, mass change ratio, and length change ratio were measured according to the NT BUILD 492 and JSTM C 7401, respectively. It was observed from the test results that the resistance against chloride ion and sulfate attack of the cemetntless concrete were comparatively largely increased than those of OPC concrete with decreasing water-binder ratio.

Analysis of Effective Soil Thermal Conductivities and Borehole Thermal Resistances with a Line Source Method (선형열원법에 의한 지중유효열전도도와 보어홀 전열저항 해석)

  • Lee, Se-Kyoun;Woo, Joung-Son;Ro, Jeong-Geun
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.4
    • /
    • pp.71-78
    • /
    • 2010
  • Investigation of the effective soil thermal conductivity(k) is the first step in designing the ground loop heat exchanger(borehole) of a geothermal heat pump system. The line source method is required by New and Renewable Energy Center of Korea Energy Management Corporation in analyzing data obtained from thermal response tests. Another important factor in designing the ground loop heat exchanger is the borehole thermal resistance($R_b$). There are two methods to evaluate $R_b$ : one is to use a line source method, and the other is to use a shape factor of the borehole. In this study, we demonstrated that the line source method produces better results than the shape factor method in evaluating $R_b$. This is because the borehole thermal resistance evaluated with the line source method characteristically reduces the temperature differences between an actual and a theoretical thermal behaviors of the borehole. Evaluation of $R_b$ requires soil volumetric heat capacity. However, the effect of the soil volumetric heat capacity on the borehole thermal resistance is very small. Therefore, it is possible to use a generally accepted average value of soil volumetric heat capacity($=2MJ/m^3{\cdot}K$) in the analysis. In this work, it is also shown that an acceptable range of the initial ignoring time should be in the range of 8~16hrs. Thus, a mean value of 12 hrs is recommended.

Chemical Resistance of Recycled Aggregate Concrete Using Pozzolanic Materials (포졸란 재료와 순환골재를 사용한 콘크리트의 화학약품 저항성)

  • Moon, Dae-Joong;Choi, Jae-Jin;Kim, Wan-Jong;Kim, Hak-Soo
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.5 no.3
    • /
    • pp.63-69
    • /
    • 2010
  • This study investigates the chemical resistance of the recycled aggregate concrete containing calcined ground slag, fly ash, and diatom powder. The recycled aggregate which had the density of $2.48g/cm^3$, the absorption of 4.25%, and standard gradation was used and the concrete specimens were submerged in solutions of $Na_2SO_4$ and $CaCl_2$ at 10% concentration for 6 months. As the submersion result, pore volume of over $0.02{\mu}m$ diameter was formed less in the concrete specimens containing calcined ground slag, fly ash, and diatom powder than in the concrete without the pozzolanic materials and the result shows the effectiveness of the pozzolanic materials for the increase of chemical resistance of the recycled aggregate concrete.

  • PDF

Analysis of Shear Resistance Characteristics in Pile-Soil Interface using Large-Scale Direct Shear Test (대형직접전단시험을 통한 말뚝과 지반 경계면의 전단특성 분석)

  • You, Seung-Kyong;Hong, Gigwon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.21 no.3
    • /
    • pp.61-69
    • /
    • 2022
  • In this study, a large-scale direct shear test was performed to evaluate the shear characteristics of the pile-soil interface according to the fines content and confining pressure conditions as a reasonable evaluation method of the pullout resistance performance of pile considering the soil conditions. It was found that the shear stress was greatly generated under the conditions of high normal stress and low fines content. In addition, the maximum shear stress was found to be rather large under the conditions of the same normal stress and fines content, when pile surface had high roughness. The internal friction angle decreased at the pile-soil interface, when the fines content in the ground increased. On the other hand, the cohesion decreased under the condition of high fines content. And the internal friction angle and cohesion were large regardless of the fines content in the model ground, when the roughness of the pile surface was high.

A Design of 5.8 ㎓ Oscillator using the Novel Defected Ground Structure

  • Joung, Myoung-Sub;Park, Jun-Seok;Lim, Jae-Bong;Cho, Hong-Goo
    • Journal of electromagnetic engineering and science
    • /
    • v.3 no.2
    • /
    • pp.118-125
    • /
    • 2003
  • This paper presents a 5.8-㎓ oscillator that uses a novel defected ground structure(DGS), which is etched on the metallic ground plane. As the suggested defected ground structure is the structure for mounting an active device, it is the roles of a feedback loop inducing a negative resistance as well as a frequency-selective circuit. Applying the feedback loop between the drain and the gate of a FET device produces precise phase conversion in the feedback loop. The equivalent circuit parameters of the DGS are extracted by using a three-dimensional EM simulation ,md simple circuit analysis method. In order to demonstrate a new DGS oscillator, we designed the oscillator at 5.8-㎓. The experimental results show 4.17 ㏈m output power with over 22 % dc-to-RF power efficiency and - 85.8 ㏈c/Hz phase noise at 100 KHz offset from the fundamental carrier at 5.81 ㎓.

Ground Impedance Characteristics Analysis of a Rod Type Grounding Electrode used for Distribution Systems (배전계통에 사용되는 봉형 접지전극의 접지 임피던스 특성 분석)

  • Kim, Kyung-Chul;Jin, Seong-Eun;Lee, Joo-Hong;Kim, You-June;Choi, Jong-Ki;Baek, Nam-Woong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.6
    • /
    • pp.67-74
    • /
    • 2005
  • Grounding insures a reference potential point for electric devices and also provides a low resistance path for fault currents in the earth. The ground impedance as a function of frequency is necessary for determining its performance since fault currents could contain a wide range of frequencies. In this paper, the ground impedance of Magic rods which are commercially available has been measured in frequency ranging from 0[Hz] up to 100[kHz] and an equivalent circuit model, transfer function model of the ground impedance are identified from the measured values.

Ground Impedance Characteristics Analysis of a Copper Rod-type Grounding Electrode used for Electric Distribution Systems (배전계통에 사용되는 동봉 접지전극의 접지 임피던스 특성 분석)

  • Kim, Kyung-Chul;Lee, Joo-Hong;Jin, Seong-Eun;Oh, Jung-Suk;Park, Sang-Young;Choi, Jong-Ki;Kim, You-June
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.6
    • /
    • pp.46-51
    • /
    • 2005
  • Grounding insures a reference potential point for electric devices and also provides a low resistance path for fault currents in the earth. The ground impedance as a function of frequency is necessary for determining its performance since fault currents could contain a wide range of frequencies. A cower rod electrode is the most commonly used grounding electrode in electric distribution systems. In this paper, the ground impedance of cower rods has been measured in frequency ranging from 60[Hz] up to 100[kHz] and an equivalent circuit model, transfer function model of the ground impedance are identified from the measured values.