• Title/Summary/Keyword: Ground Resistance

Search Result 1,049, Processing Time 0.028 seconds

Electrical Output and Reliability of Photovoltaic Module Using Ethylene Tetrafluoroethylene Film (ETFE 필름을 적용한 태양광 모듈의 전기적 출력 및 신뢰성에 관한 연구)

  • Shin, Woogyun;Lim, Jongrok;Ko, Sukwhan;Kang, Gihwan;Ju, Youngchul;Hwang, Heymi
    • Journal of the Korean Solar Energy Society
    • /
    • v.40 no.4
    • /
    • pp.13-22
    • /
    • 2020
  • As the supply of photovoltaic (PV) increases worldwide, the cumulative installations in 2018 were 7.9 and 560 GW in Korea and the world, respectively. Typically, when the ground on commercial PV modules is installed, the area is limited; hence, new designs of PV modules are required to install additional PVs. Among the new design of PV modules, lightweight PV modules can be utilized in PV systems, such as buildings, farmlands, and floating PV. Concerning the investigation of lightweight PV modules, several studies on materials for replacing low-iron tempered glass, which comprises approximately 65% of the PV module weight, have been conducted. However, materials that are used as substitutes for glass should possess similar lightweight properties and reliability as glass. In this study, experimental tests were performed to evaluate the applicability of ethylene tetrafluoroethylene (ETFE) film with excellent resistance to water and aging as a front material of PV modules. The transmittance and ultraviolet properties of the ETFE film were determined and compared with those of glass. A 1-cell module and laboratory-scale 24-cell module were manufactured using the ETFE film and glass, and the electrical output was measured and analyzed. Furthermore, damp heat and thermal cycle tests were conducted to evaluate the reliability of the ETFE film module. Based on the experimental results, the electrical output and reliability of the ETFE film module were similar to those of the glass module, and the ETFE film could be used as the front material of PV modules.

Analysis of Piled Raft Interactions on Clay with Centrifuge Test (원심모형실험을 통한 점토지반에서의 말뚝지지 전면기초 상호작용)

  • Park, Dong-Gyu;Choi, Kyu-Jin;Lee, Jun-Hwan
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.9
    • /
    • pp.57-67
    • /
    • 2012
  • In the design for piled rafts, the load capacity of the raft is in general ignored and the load capacities of pile are only considered for the estimation of the total load carrying capacity of the piled raft. The axial resistance of piled raft is offered by the raft and group piles acting on the same supporting ground soils. As a consequence, pile - soil - raft and pile - soil interactions, occurring by stress and displacement duplication with pile and raft loading conditions, acts as a key element in the design for piled rafts. In this study, a series of centrifuge model tests has been performed to compare the axial behavior of group pile and raft with that of a piled raft (having 16 component piles with an array of $4{\times}4$) at the stiff and soft clays. From the test results, it is observed that the interactions of piles, soil, and raft has little influences on the load capacities of piles and raft in piled rafts compared with the load capacities of group piles and raft at the same clay soil condition.

Application of Alkali-Activated Ternary Blended Cement in Manufacture of Ready-Mixed Concrete (알칼리 활성화 3성분계 혼합시멘트의 레미콘 적용 시험)

  • Yang, Wan-Hee;Hwang, Ji-Soon;Lee, Sea-Hyun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.17 no.1
    • /
    • pp.47-54
    • /
    • 2017
  • Cement industry is typical carbon-emission industry. If the industrial by-products(granulated blast-furnace slag (GGBFS), fly ash, etc.) are used a large amount, it might be able to reduce cement consumption and mitigate carbon emissions. In this case, however, decrease of early strength is relatively large. Therefore, there is a limitation in increase of the amount of substitute. Considering these circumstances, it would be a good solution to reduce carbon emissions in cement industry to improve the performances of mixed cement through proper alkali-activation in Portland blended cement using GGBFS or fly ash. Therefore, this study prepared concrete in ready-mixed concrete manufacturing facilities with an addition of a binder which used 2.0% modified alkali sulfate activator after mixing Portland cement, GGBFS and fly ash in the ratio of 4:4:2 and assessed its basic properties. The results found the followings: The use of modified alkali-sulfate activator slightly reduced slump and shortened setting time. As a result, bleeding capacity decreased while early strength improved. In addition, there is no big difference in carbonation resistance. It appears that there should be continued experiments and analyses on the related long-term aged specimens.

Generation of Chemically Active Species in Hybrid Gas-Liquid Discharges (기체-액체 혼합 방전에 의한 화학적 활성종 생성 특성)

  • Chung, Jae-Woo;Locke, Bruce R.
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.5
    • /
    • pp.556-563
    • /
    • 2007
  • We carried out a laboratory scale experiment about the characteristics of chemically active species produced in hybrid gas-liquid discharges. The electrode configuration which had high voltage electrode in the gas phase and ground electrode in the liquid was utilized while high voltage electrode has been typically positioned in the liquid in other studies. Our electrode was configured in such a way as to increase the energy efficiency of chemical reactions by creating a higher electrical field strength and a narrower pulse width than the typical electrode configuration. The highest ozone concentration was obtained at 45 kV which was the medium value in operating voltages. The decrease of solution conductivity increased the resistance of liquid phase and the electric field strength through the gas phase, so ozone gene-ration rate was enhanced. The increase of voltage promoted the production rate of hydrogen peroxide by increasing the electric field strength. In a lower voltage, the increase of solution conductivity increased the degradation rate of $H_2O_2$, so the $H_2O_2$ generation rate decreased. On the other hand, the effects of UV radiation, shock waves etc. increased the $H_2O_2$ generation rate as the solution conductivity increased. A higher rate of $H_2O_2$ generation can be achieved by mixing argon to oxygen which generates a stronger and more stable discharges.

Sulfate Resistance of Alkali-Activated Materials Mortar (알칼리 활성화 결합재 활용 모르타르의 황산염 침식 저항성)

  • Park, Kwang-Min;Cho, Young-Keun;Lee, Bong-Chun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.2
    • /
    • pp.94-101
    • /
    • 2016
  • This paper presents an investigation into the durability alkali-activated materials(AAM) mortar and paste samples manufactured using fly-ash(FA) and ground granulated blast furnace slag(GGBFS) exposed to a sulfate environment with different GGBFS replace ratios(0, 30, 50 and 100%), sodium silicate modules($Ms[SiO_2/Na_2O]$ 1.0, 1.5 and 2.0) and initial curing temperatures($23^{\circ}C$ and $70^{\circ}C$). The tests involved immersions for a period of 6 months into 10% solutions of sodium sulfate and magnesium sulfate. The evolution of compressive strength, weight, length expansion and microstructural observation such as x-ray diffraction were studied. As a results, as higher GGBFS replace ratio or Ms shown higher compressive strengths on 28 days. In case of immersed in 10% sodium sulfate solution, the samples shows increase in long-term strength. However, for samples immersed in magnesium sulfate solutions, the general observation was that the compressive strength decreased after immersion. The most drastic reduction of compressive strength and expansion of weight and length occurred when GGBFS or Ms ratios were higher. Also, the XRD analysis of samples immersed in magnesium sulfate indicated that expansion of AAM caused by gypsum($CaSO_4{\cdot}2H_2O$); the gypsum increased up to 6 months continuously.

Physiological and Biochemical Responses of Sedum kamtschaticum and Hosta longipes to Ozone Stress (기린초와 비비추의 오존에 대한 생리·생화학적 반응)

  • Cheng, Hyo Cheng;Woo, Su Young;Lee, Seong Han;Kwak, Myeong Ja;Kim, Kyeong Nam
    • Horticultural Science & Technology
    • /
    • v.31 no.1
    • /
    • pp.1-7
    • /
    • 2013
  • In this study, the resistance to ozone and characteristics of ozone-induced damage were investigated on the perennial ground cover plant species. Sedum kamtschaticum and Hosta longipes were exposed to $200{\mu}g{\cdot}kg^{-1}$ ozone for 8 hours per day (from 08:00 to 16:00) in the naturally irradiated phytotron. The extent of ozone-induced damage was measured through the analysis of physiological parameters, such as water use efficiency (WUE), chlorophyll content (Chl. a, Chl. b, Chl. a + b, and Chl. a/b ratio), carotenoid contents, and the induction of reactive oxygen species (ROS). Ozone exposure significantly reduced the daytime WUE in both species. The contents of chlorophyll and carotenoid were also decreased and ROS, such as hydrogen peroxide ($H_2O_2$) and superoxide radical ($O_2{^-}$) were accumulated after ozone exposure. The above results of this study suggested that S. kamtschaticum is more resistant to atmospheric ozone than Hosta longipes. Considering its fast responses to ozone, it was also assumed that Hosta longipes can be used as an indicator plant of an increase in atmospheric ozone concentration.

Study on the Improvement of Stow Net Fishing Technigue and the Enlargement of Fishing Groung to the Distant Waters 2 . Model Experiment on the Newly Designed Gear (안강망어법의 개량과 어장의 원해로의 확대를 위한 연구 - 2 . 새로 설계된 어구의 모형실험 -)

  • Lee, Byeong-Gi;Kim, Jin-Geon;Lee, Ju-Hui
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.25 no.1
    • /
    • pp.6-11
    • /
    • 1989
  • Some distinctive defects in the conventional stow net were examined and presented in the previous report of this series. To find out the more effective gear by correcting the defects, the authors carried out another experiment by using a newly designed gear. 1. Special features of the newly designed gear are: (1) stretched width of front end on top, bottom and side panel are decreased 20%, on the other hand, the frank of the panels are increased 10% compared with the conventional gear. Front end of top and bottom panels are bias cutten up to 20% of the length of panels. (2) Length of the head rope and ground rope are shortened 6% by changing of the shape of the top and bottom panels. (3) Lacing lines are attached to four longitudinal seaming lines with suitable hanging ratio. (4) Stretched height of the shearing device were shortened 17%, and the buoyancy on top of the device were increased 20%. (5) Length of the biforked pendants were arranged to be shorter on top-most and bottom-most ones, and loner on middle ones. 2. The observed result can be expressed as (1) Wrinkles in the front end of top panels are removed and fringe line of panels become smooth. (2) Opening height of mouth is observed 3% higher than that of the conventional gear. (3) Opening width is 1.5 to 1.6 times wider than that of the conventional gear. (4) Hydrodynamic resistance is decreased 10%-17%.

  • PDF

The Effect of Composite Ratio and Wall Thickness on the Shear Behavior of Composite Basement Wall (합성율과 벽체두께가 합성지하벽의 전단거동에 미치는 영향)

  • Seo, Soo-Yeon;Kim, Seong-Soo;Yoon, Yong-Dae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.1
    • /
    • pp.93-101
    • /
    • 2010
  • When doing underground excavation works for the purpose of constructing large underground structures for a building in the limited space in downtown area, the stability of the adjacent ground must be top priority, and to accomplish this, it is essential to review the retaining wall construction carefully. H-Pile, which has been mainly used as a stress-carrying material in temporary earth-retaining structures, is most likely to be abandoned after completion of the works for the basement exterior wall in relation to contiguous bored piles, so it will result in a waste of material. To improve this situation, Basement Composite Wall where H-Pile and basement wall are compounded, has been developed. This wall is being used most frequently in many local construction sites. In this study, five specimens are made in order to evaluate the shear resistance of the basement composite wall and tested. Test parameter is the composition ratio and wall thickness according to shear connectors. Test result shows that the shear strength is improved when the composite ratio is increased but the magnitude is not much. A formula, which considers the contribution of concrete, web of H-pile as well as flange' effect in calculation of shear strength of composite basement wall, is suggested and used to calculation of the strength of specimens. It is found that there is a good co-relation between test result and the calculated one by the formula.

Electrical Resistivity of ITZ According to the Type of Aggregate (골재 종류별 시멘트 경화체 계면의 전기저항 특성)

  • Kim, Ho-Jin;Bae, Je Hyun;Jung, Young-Hoon;Park, Sun-Gyu
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.3
    • /
    • pp.268-275
    • /
    • 2021
  • The three factors that determine the strength of concrete are the strength of cement paste, aggregate and ITZ(Interfacial Transition Zone) between aggregate and cement paste. Out of these, the strength of ITZ is the most vulnerable. ITZ is formed in 10~50㎛, the ratio of calcium hydroxide is high, and CSH appears low ratio. A high calcium hydroxide ratio causes a decrease in the bond strength of ITZ. ITZ is due to further weak area. The problem of ITZ appears as a more disadvantageous factor when it used lightweight aggregate. The previous study of ITZ properties have measured interfacial toughness, identified influencing factors ITZ, and it progressed SEM and XRD analysis on cement matrix without using coarse aggregates. also it was identified microstructure using EMPA-BSE equipment. However, in previous studies, it is difficult to understand the microstructure and mechanical properties. Therefore, in this study, a method of measuring electrical resistance using EIS(Electrochemical Impedance Spectroscopy) measuring equipment was adopted to identify the ITZ between natural aggregate and lightweight aggregate, and it was tested the change of ITZ by surface coating of lightweight aggregate with ground granulated blast furnace slag. As a result, the compressive strength of natural aggregate and lightweight aggregate appear high strength of natural aggregate with high density, surface coating lightweight aggregate appear strength higher than natural aggregate. The electrical resistivity of ITZ according to the aggregate appeared difference.

A Study on Operation Method of Protection Device for LVDC Distribution Feeder in Light Rail System (경전철용 LVDC 배전계통의 보호기기 운용 방안에 관한 연구)

  • Kang, Min-Kwan;Choi, Sung Sik;Lee, Hu-Dong;Kim, Gi-Yung;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.4
    • /
    • pp.25-34
    • /
    • 2019
  • Recently, when a fault occurs at a long-distance point in a LVDC (low voltage direct current) distribution feeder in a light rail system, the magnitude of the current can decrease to less than that of the load current of a light rail system. Therefore, proper protection coordination method to distinguish a fault current from a load current is required. To overcome these problems, this paper proposes an optimal algorithm of protection devices for a LVDC distribution feeder in a light rail system. In other words, based on the characteristics of the fault current for ground resistance and fault location, this paper proposes an optimal operation algorithm of a selective relay to properly identify the fault current compared to the load current in a light rail system. In addition, this paper modelled the distribution system including AC/DC converter using a PSCAD/EMTDC S/W and from the simulation results for a real light rail system, the proposed algorithm was found to be a useful and practical tool to correctly identify the fault current and load current.