• Title/Summary/Keyword: Ground Magazine

Search Result 241, Processing Time 0.026 seconds

A Study on the Evaluation of Dynamic Behavior and Liquefaction Cau8ed by Earthquake of Sea Dike Structures on the Ground (방조제 축조 예정지반의 지진에 의한 액상화 거동 평가)

  • 도덕현;장병욱;고재만
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.35 no.2
    • /
    • pp.43-56
    • /
    • 1993
  • The laboratory tests are performed on how the liquefaction potential of the sea dike structures on the saturated sand or silty sand seabed could be affected due to earthquake before and after construction results are given as follows ; 1. Earthquake damages to sea dike structures consist of lateral deformation, settlement, minor abnormality of the structures and differential settlement of embankments, etc. It is known that severe disasters due to this type of damages are not much documented. Because of its high relative cost of the preventive measures against this type of damages, the designing engineer has much freedom for the play of judgement and ingenuity in the selection of the construction methods, that is, by comparing the cost of the preventive design cost at a design stage to reconstruction cost after minor failure. 2. The factors controlling the liquefaction potential of the hydraulic fill structure are magnitude of earthquake(max. surface velocity), N-value(relative density), gradation, consistency(plastic limit), classification of soil(G & vs), ground water level, compaction method, volumetric shear stress and strain, effective confining stress, and primary consolidation. 3. The probability of liquefaction can be evaluated by the simple method based on SPT and CPT test results or the precise method based on laboratory test results. For sandy or silty sand seabed of the concerned area of this study, it is said that evaluation of liquefaction potential can be done by the one-dimensional analysis using some geotechnical parameters of soil such as Ip, Υt' gradation, N-value, OCR and classification of soils. 4. Based on above mentioned analysis, safety factor of liquefaction potential on the sea bed at the given site is Fs =0.84 when M = 5.23 or amax= 0.12g. With sea dike structures H = 42.5m and 35.5m on the same site Fs= 3.M~2.08 and Fs = 1.74~1.31 are obtained, respectively. local liquefaction can be expected at the toe of the sea dike constructed with hydraulic fill because of lack of constrained effective stress of the area.

  • PDF

Earthquake Simulation Tests of A 1:5 Scale Gravity Load Designed 3-Story Reinforced Concrete Frame (중력하중 설계된 1:5 축소 3층 철근콘크리트 골조의 지진모의실험)

  • 이한선;우성우
    • Magazine of the Korea Concrete Institute
    • /
    • v.10 no.6
    • /
    • pp.241-252
    • /
    • 1998
  • The objective of the research stated herein is to observe the actual responses of a low-rise nonseismic moment-resisting reinforced concrete frame subjected to varied levels of earthquake ground motions. First, the reduction scale for the model was determined as 1 : 5 considering the capacity of the shaking table to be used and the model was manufactured according to the similitude law. This model was, then, subjected to the shaking table motions simulating Taft N21E component earthquake ground motions, whose peak ground accelations (PGAs) were modified to 0.12g, 0.2g, 0.3g, and 0.4g. The lateral accelerations and displacements at each story and local deformations at the critical reginos of the structure were measured. The base shear was measured by using self-made load cells. Before and after each earthquake simulation test, free vibration tests were performed to find the change in the natural period and damping ratio of the model. The test data on the global and local behaviors are interpreted. The model showed the linear elastic behavior under the Taft N21E motion with the PGA if 0.12g, which represents the design earthquake in Korea. The maximum base shear was 1.8tf, approximately 4.7 times the design base shear. The model revealed fairly good resistance to the higher level of earthquake simulation tests. The main components of its resistance to the high level of earthquakes appeared to be 1) the high overstrength, 2) the elongation of the fundamental period, and 3) the minor energy dissipation by inelastic deformations. The drifts of the model under these tests were approximately within the allowable limit.

A Study on the Design of Rotary Mower and Its Utilization. (Rotary Mower의 제작과 그 이용에 관한 연구)

  • 최규홍
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.17 no.4
    • /
    • pp.3897-3920
    • /
    • 1975
  • Since the most of Korean dairy and cattle raising farms are too small to introduce western mechanized farming, it is necessary to develope small size equipments. This study has been carried to develop a rotary mower as on attachment of 8 to 10 horse powertiller which is widely spread in rural area. It will not ony be helpfull for the farmers to harvesting hay grass but also desirable to increase the power tiller utility. The protto type rotary mower designed through the fundamental investigations, has been modified and improved through the field trials, and a series of field tests has been carried to investigate its performance and economic feasibility comparing with existing vailable harvesting equipments. The results are as follows; 1. To increase the stability, two guide wheels are attached to both side of the protto type rotary mower. 2. To prevent the clinging of tall grasses, the vertical driving shafts are covered with cylindrical protectors. 3. The cutting height is adjustable in 8 steps from 2.5 to 20 centimeters by changing the length of guide wheel legs. 4. The practical Critical cutting speed were always higher than theoretical value in both case of single cutting blade and three when the cutting depth was 25 millimeter. 5. The peripheral speed of cutting blade was varied in response to the change of engine speed, mean while the peripheral speed was adequate as it was changhed from 25 to 35 meter per second when the power tiller is operated in proper working ground speed. 6. The time requirement to harvest 10 a were 88.7, 54.6 and 41.4 minutes for the first, second and third stage of ground speed respectively, and because of the difficulty of delivery, it was observed that operating with fourth stage of ground speed was not recomanendable when the grass height is taller than 90 centimeters. 7. The performance of rotary mower were 1.1-1.7, 1.4-4.0, 3.8-11.8 and 7.4-22.0 times of reciprocating mower, portable disc type cutter, hay scythe and ordinary sickle respectively. 8. When the slope exceeds, 20 degree the downward harvesting operation was impossible because of the excessive front end weight, while less than 5 degree of land slope did not effect in field operation. 9. Increased traveling spee caused higher cutting height and slight cutting failure, but seems not to effect to the gross yield, and the efficiency of cutting width were from 83 to 94 precent. 10. Tn rank of economy were rotary mower (3,2 stage operation), reciprocating mower, hay scythe, portable disc type cutter and sickle in order when the annul operation exdeeds 100 hours. From the above results, it is convinced that the protto type rotary mower is good enough to the livestock farmers as a hay harvesting equipment because of its economy, hardiness in operating and its out standing performance and hopefully it will contribute to the extension of Korean livestock farming.

  • PDF

A Study on the Structural Characteristics and Estimation of Refrigerating. Load for the Fruit Storage (청과물저장고의 구조특성 및 냉각부하량 산정에 관한 연구)

  • 이석건;고재군
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.18 no.1
    • /
    • pp.4038-4051
    • /
    • 1976
  • This study was intended to provide the basic design creteria for the refrigerated storage, and to estimate the required optimum capacity of refrigerator for the different sizes and kinds of the existing fruit storage. The structural characteristics of the existing fruit storages in Pyungtaek-khun of Kyungki-do were surveyed. The average out-door air temperature during the expected storage life after harvesting, was obtained by analyzing the weather information. The heat transfer rates through the different models of storage walls were estimated. The refrigerating load required for different models of fruit storage was analyzed in the basis of out-door air temperature. The results obtained in this study are summarized as follows: 1. The fruit storages surveyed were constructed on-ground, under-ground and sub-ground type buildings. The majority of them being the on-ground buildings are mostly made of earth bricks with double walls. Rice hull was mostly used as the insulating materials for their walls and ceilings. About 42% of the buildings were with the horizontal ceiling, 22% with sloped ceiling, and about 36% without ceiling. About 60% of the storage buildings had floor without using insulated material. They were made of compacted earth. 2. There is no difference in heat transfer among six different types of double walls. The double wall, however, gives much less heat transfer than the single wall. Therefore, the double wall is recommended as the walls of the fruit storage on the point of heat transfer. Especially, in case of the single wall using concrete, the heat transfer is about five time of the double walls. It is evident that concrete is not proper wall material for the fruit storage without using special insulating material. 3. The heat transfer through the storage walls is in inverse proportion to the thickness of rice hull which is mostly used as the insulating material in the surveyed area. It is recommended that the thickness of rice hull used as the insulating material far storage wall is about 20cm in consideration of the decreasing rate of heat transfer and the available storage area. 4. The design refrigerating load for the on-ground storages having 20 pyung area is estimated in 4.07 to 4.16 ton refrigeration for double walls, and 5.23 to 6.97 ton refrigeration for single walls. During the long storage life, however, the average daily refrigerating load is ranged from 0.93 to 0.95 ton refrigeration for double walls, and from 1.15 to 1.47 ton refrigeration for single walls, respectively. 5. In case of single walls, 50.8 to 61.4 percent to total refrigerating load during the long storage life is caused by the heat transferred into the room space through walls, ceiling and floor. On the other hand, 39.1 to 40.7 percent is for the double walls. 6. The design and average daily refrigerating load increases in linear proportion to the size of storage area. As the size increases, the increasing rate of the refrigerating load is raised in proportion to the heat transfer rate of the wall. 7. The refrigerating load during the long storage life has close relationship to the out-door air temperature. The maximum refrigeration load is shown in later May, which is amounted to about 50 percent to the design refrigerating load. 8. It is noted that when the wall material having high heat transfer rate, such as the single wall made of concrete, is used, heating facilities are required for the period of later December to early February.

  • PDF

Design consideration and explosion safety of underground ammunition storage facilities (지하탄약고의 설계요소 및 폭발안전 연구)

  • Kim, Oon-Young;Lee, Myung-Jae;Kim, Min-Seok;Kim, Joon-Youp;Joo, Hyo-Joon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.5 no.1
    • /
    • pp.55-70
    • /
    • 2003
  • Ammunition magazine, which is installed on the ground, has difficulty in protecting from the external attack, and accidental explosion should cause great damage to the life and property. For these reasons, it is needed to develop underground magazine that it has the advantages of safety, security and maintenance. This paper introduce the design case for blasting facilities, which should resist blasting pressure, as well as layout of underground magazine, which takes a safety for explosion and a working space of loading/unloading machine into consideration. On the layout, in case of ${\bigcirc}{\bigcirc}$ underground magazine, put three storage chambers in position almost parallel with principle stress direction, where less effected on discontinuity and hard rock area. Also, secured safe distance according to safety criteria of the Defense Ministry, and verified suitable layout by trace simulation for loading/unloading machine on working stage. Blasting design was performed on evaluation of maximum blast pressure between donar and acceptor chambers, and design condition for blast door, valve, etc. Diminution facilities against explosion, such as thrust block or debris trap, determined its size after plan in accordance with blasting criteria and calculation by structural analysis.

  • PDF

A Divece for Reducing the Zero phaze Harmonics of Neutral Line of Power Facility (전기수용설비의 중성선 영상분고조파전류저감장치)

  • Kang, Chang-Won;Choi, Gil-Soo;Han, Sung-Bae;Kim, Bum-Soo;Chung, Yeon-Hae;Lee, Ki-Cheol
    • Electric Engineers Magazine
    • /
    • v.228 no.8
    • /
    • pp.43-48
    • /
    • 2001
  • Wide use of non-linear loads such as personal computers, monitors, laser printers, variable speed drives, UPS systems and other electronic equipment have led to harmonics becoming #1 issue in the electrical industry today. Commercial and Industrial building power distribution systems, designed for the old, linear-style loads especially when found in high densities. Some common power system problems include overloaded neutral conductors, overheated distribution transfOlmers, high neutral-to-ground voltage, poor power factor and distortion of the voltage waveform supplying these loads. The power quality problems, particularly high voltage distortion, have been known to cause equipment downtime due to malfunctions and component failure.

  • PDF

Problems and Inprovement Method of Grounding System in Electrical Facilities (건축전기설비에 적용되는 접지시스템 문제점과 개선방안)

  • Chung, Young-Ki;Kwak, Hee-Ro;Shin, Hyo-Sub;Chung, Chun-Byoung;Nam, Taik-Joo
    • Electric Engineers Magazine
    • /
    • v.228 no.8
    • /
    • pp.52-57
    • /
    • 2001
  • Presently the Korean grounding system uses TN system, multi-grounding method with IT independent grounding method. Nevertheless TN system can't exist with TT system in the technological terms. If they coexist, it causes ground-fault circuit not to operate, and brings about different electrical potential rise by customer system. It brings about serious problems for safety. This paper aims for improving method of grounding system based on the technical analysis on instances in foreign countries and Korea. Almost standards and construction manner were apt to be internationalized after WTO/TBT agreement was concluded. The internal grounding systems should meet the international criteria and reliability for safety, and be provided with technologically impeccable standards.

  • PDF

Expected Damage Analysis of Risk Exposure Object by Violation Rate of Safety Distance in Explosion of Ground Type Magazine (지상형 탄약고 폭발 시 안전거리 위반율에 따른 위험노출대상의 피해 수준 분석 연구)

  • Ham, Tae Yuun;Lee, Jae Joon
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.4
    • /
    • pp.92-100
    • /
    • 2022
  • Of the Korean military's 3,959 ammunition depots, 1,007 - more than 25% - violate safety requirements for distance and equipment. There is a risk of explosion in old depots that are vulnerable to various interior and exterior accidents. This paper examines 10 scenarios, with varying values for ammunition amount and safety distance. The study calculated the overpressure that can be applied to risk-exposure objects, based on the safety distance; expected damage was predicted using constructed spatial information from 3D explosion simulations. The simulations confirmed that explosion overpressure increased the most when the safety distance violation rate increased from 80% to 90%. It also confirmed that secondary damage such as fire and explosion can cause casualties and property damage when the violation rate is 60% or higher. The results show that building collapse becomes a risk with a violation rate of 70% or higher. We conclude that taking ammunition depot safety distance violation into account when planning military facilities and their land utilization could better protect life and property.

A STUDY ON THE ANATOMY OF THE PULP CHAMBR FLOOR OF THE PERMANENT MANDIBULAR FIRST MOLAR (하악 제1대구치 치수저의 해부학적 고찰)

  • Kwon, Hyuk-Choon
    • The Journal of the Korean dental association
    • /
    • v.22 no.5 s.180
    • /
    • pp.423-427
    • /
    • 1984
  • A total of 114 extracted human mandibular first molars were used to study the configuration of the floor of the chamber. The specimens were ground and the pulp chamber was examined with a magnifier and explored with sharp explorer. The study showed the shape of the pulp chamber, number of root canals, and the type of canal orifice. The results were as follows; 1. In so far as observing the shape of the pulp chamber of the teeth, 58.8% of the teeth were square, 34.2% were triangle and 7.0% were ovoid shape. 2. 58.8% of the specimens have 4 root canal orifices, 34.2% have 3 root canal orifices, 7.0% have 2 root canal orifices. 3. 41.2% of the specimens show 'H' shape, 17.6% show 'Square' shape, 31.6% show 'T' shape, 2.0% show 'reverse-T' shape and 7.0% show 'I' shape.

  • PDF

이동로봇주행을 위한 영상처리 기술

  • 허경식;김동수
    • The Magazine of the IEIE
    • /
    • v.23 no.12
    • /
    • pp.115-125
    • /
    • 1996
  • This paper presents a new algorithm for the self-localization of a mobile robot using one degree perspective Invariant(Cross Ratio). Most of conventional model-based self-localization methods have some problems that data structure building, map updating and matching processes are very complex. Use of a simple cross ratio can be effective to the above problems. The algorithm is based on two basic assumptions that the ground plane is flat and two locally parallel sloe-lines are available. Also it is assumed that an environmental map is available for matching between the scene and the model. To extract an accurate steering angle for a mobile robot, we take advantage of geometric features such as vanishing points. Feature points for cross ratio are extracted robustly using a vanishing point and intersection points between two locally parallel side-lines and vertical lines. Also the local position estimation problem has been treated when feature points exist less than 4points in the viewed scene. The robustness and feasibility of our algorithms have been demonstrated through real world experiments In Indoor environments using an indoor mobile robot, KASIRI-II(KAist Simple Roving Intelligence).

  • PDF