• 제목/요약/키워드: Ground Investigation

검색결과 1,057건 처리시간 0.026초

현장조사를 통한 건축물 접지저항 측정용 전극 설치의 개선에 관한 연구 (A Study on the Improvement of Electrode Installation for Measurement of Ground Resistance through Investigation on the Spot in Buildings)

  • 길형준;김동우;길경석
    • 조명전기설비학회논문지
    • /
    • 제25권5호
    • /
    • pp.92-97
    • /
    • 2011
  • This paper deals with the improvement of electrode installation for measurement of ground resistance through investigation on the spot in buildings. The investigation was carried out for an earthing terminal board for measurement of ground resistance, installation of auxiliary electrode, etc. The criteria value is set up by measuring method of ground resistance in international standard. In case of inadequate installation of auxiliary electrode, a relative error is analyzed and adequate installation method of auxiliary electrode is proposed. As a consequence, it is necessary to write direction of ground and equipment, and separate auxiliary electrode for measurement of ground resistance in order to minimize measuring error.

지반조사 분석을 통한 지반함몰 위험영향인자 연구 (A Study on Risk Influence Factors of Ground Subsidence through Soil Investigation Analysis)

  • 정호영;이길환
    • 한국방재안전학회논문집
    • /
    • 제10권1호
    • /
    • pp.43-46
    • /
    • 2017
  • 최근 도심지 포화로 전 세계적으로 지하공간개발이 활발히 진행되고 있으며 굴착공사는 지상 및 지하의 굴착 인접 구조물에 의한 다양한 굴착공법으로 시공이 주로 이루어지고 있다. 굴착공사 중 시공 부주의나 시공기술 미흡, 지하수 유출, 급격한 지층의 변화에 대응실패, 토류 시스템 구성품의 문제등으로 인해 각종 지반함몰 사고가 발생하고 있다. 지반함몰 방지를 위해 지반조사 분석을 통한 지반함몰 위험영향인자를 도출하고자 한다. 최근 75개소 지반조사값을 토대로 지반함몰 요인을 분석하고 조사항목으로는 지역별, 통일분류법(U.S.C.S), 공법, 굴착심도를 통해 분석을 하였다.

폐기물매립지 주변 토양 및 지하수 오염도 조사 및 분석 (Investigation and Assesment of Ground Contamination around Waste Landfill)

  • 정하익;김상근
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2000년도 창립총회 및 춘계학술발표회
    • /
    • pp.116-119
    • /
    • 2000
  • There has been a steady increase in geoenvironmental engineering projects where geotechnical engineering has been combined with environmental concerns. Many of these projects involve some investigation on contaminant and leachate flume in the ground and landfill. In this study, investigation and assesment on soil and groundwater around the waste landfill was carried out. Many techniques such as drilling and sampling method were applied. As a result of this study, the concentration of soil and groundwater were investigated and analysed.

  • PDF

환경콘에 의한 지하유류 저장시설주변 지반환경 조사 (Investigation of Ground Environment Around Underground Oil Storage Facilities Using the Envi-Cone Penetrometer System)

  • 정하익;홍승서;김영진;홍성완;곽무영
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.273-280
    • /
    • 2000
  • In recent years there has been a steady increase in geoenvironmental engineering projects where geotechnical engineering has been combined with environmental concerns. Many of these projects involve some investigation of contaminant in the ground. There are many techniques such as geophysical, drilling, sampling, md pushing techniques for investigation of contaminated ground. The most rapidly developing site characterization techniques for geoenvironmental purposes involve direct push technology, that is, penetration tests. The purpose of this study investigated underground oil storage tanks(USTs) using the envi-cone penetrometer system. The electrical resistivity sensor, pH sensor, ORP sensor, and thermometer are installed in envi-cone penetrometer system. This envi-cone penetrometer system provides a continuous profile of measurements, and it is rapid, repeatable, reliable and cost effective for investigation of contaminated ground surrounding the underground oil storage tanks.

  • PDF

조력발전 구조물 설계를 위한 지반조사;인천만 지반조사 사례 (Geotechnical Site Investigation for Designing of Tidal Power Plant Structures)

  • 오명학;이광수;박진순;염기대;차대욱;양근훈
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.613-616
    • /
    • 2007
  • The main structures that comprise a tidal power plant are turbine structure, sluice structure, tide embankment and gate. Since these structures are founded on seabed ground, an extensive geotechnical site investigation to evaluate the engineering properties of field soils must be conducted prior to design and construction. According to the results of geotechnical site investigation conducted at the planned site for construction of Incheon bay tidal power plant, soft ground generally lie 7 meters below the seabed surface level. This research suggests the reliable and economical design of foundations and ground improvements required for construction of main structures in Incheon bay tidal power plant, with considerations on field conditions.

  • PDF

Study of Influence Factors for Prediction of Ground Subsidence Risk

  • Park, Jin Young;Jang, Eugene;Ihm, Myeong Hyeok
    • 한국방재안전학회논문집
    • /
    • 제10권1호
    • /
    • pp.29-34
    • /
    • 2017
  • This Analyzed case study of measuring displacement, implemented laboratory investigation, and in-situ testing in order to interpret ground subsidence risk rating by excavation work. Since geological features of each country are different, it is necessary to objectify or classify quantitatively ground subsidence risk evaluation in accordance with Korean ground character. Induced main factor that could be evaluated and used to predicted ground subsidence risk through literature investigation and analysis study on research trend related to the ground subsidence. Major factors of ground subsidence might be classified by geological features as overburden, boundary surface of ground, soil, rock and water. These factors affect each other differently in accordance with type of ground that's classified soil, rock, or complex. Then rock could be classified including limestone element or not, also in case of the latter it might be classified whether brittle shear zone or not.

호남고속철도 연약지반구간의 전단파 속도분석과 탐사법 비교 (S-wave Velocity Analysis and Each Survey Comparison of Soft Ground in HoNam High-Speed Railway)

  • 민경남;이일화;정대호;안태봉;정찬묵
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.387-394
    • /
    • 2007
  • This study area located in HoNam High-Speed railway soft ground section. So it carried out the boring survey, field survey and test of laboratory. It collected the engineering data of ground and the data for the establishment arrangement. The investigation did a soil investigation in Nonsan. The investigation item excuted seismic piezocone penetration test, s-wave seismic refraction survey, ps logging test, density logging test which is a physical exploration and boring. Eventually, results of geotechnical and shear-wave survey are useful for ground information in soft ground that has identified the characteristics of geological responses and elastic modulus.

  • PDF

서울 S지역에서 발생한 영아 메트헤모글로빈혈증 1례의 원인구명을 위한 역학조사 (Epidemiologic Investigation to Identify the Cause of an Infant Methemoglobinemia)

  • 김영열;최보율;박항배;김민영;여인학
    • Journal of Preventive Medicine and Public Health
    • /
    • 제26권2호
    • /
    • pp.192-201
    • /
    • 1993
  • Epidemiologic investigation was conducted on January, 1993 in Seoul to identify the cause of an infant methemoglobinemia. Field investigation of the area of outbreak, survey of household and family members, analysis of ground water, and blood tests of involved family members were performed. Following results were obtained On analyzing the quality of the ground water on patient's household high levels of nitrate was found indicating contamination of water as the cause of a methemoglobinemia outbreak. On analysing the quality of the ground waters on seven other places within the neighborhood five were contaminated by nitrate in concentration that exceeded the permissible limit implying presence nearby source of contamination. Sources of contamination were thought to be originating from human waste in conventional bathroom facilities, chicken manure used in nearby orchards and plant fields or fertilizers. But the results of water analysis with presence of bacteria or E.coli, concentration of potassium, phosphate and the past history of diarrhea among family members, chicken manure suggested the most possible source of contamination. To evaluate the health status of members in the neighborhood past history was reviewed revealing no prior existence of patient with cyanosis and 65 people in the neighborhood had normal levels of methemoglobin concentration in their blood. Conclusively, the ground water on patient's household was contaminated with nitrate and despite provision of adequate water supply, family members of the patient along with their distrust in the water supply system had used ground water as their source of drinking water resulting of methemoglobinemia. Many suburban area of Seoul and country side thought to be having similar problems concerning contaminated ground water supply and dormant outbreak of patients as a result of the drinking of the contaminated water. Epidemiologic investigation and water analysis of ground waters are advised.

  • PDF

전기철도 전원계통에서의 화재사고 사례 분석 (Analysis of Fire Accident on Power Line for DC Electric Traction Vehicles)

  • 송재용;조영진;남정우;김진표;박남규
    • 한국안전학회지
    • /
    • 제25권2호
    • /
    • pp.18-23
    • /
    • 2010
  • This paper describes a cause of fire accidents on power system fire DC electric traction vehicles. We investigated fire scene of power line for DC electric traction vehicles. From analysis results, the cause of fire on power line turned out line to ground fault between a feeder of electric power services(pantagraph) and DC electric traction vehicle roof. Fire accident of DC electric traction vehicles be assumed that electric sparks had been produced between the pantagraph and the power line conductor by repetitively making contact and separation, maybe if some material like branches get in between connecting rod it makes progress line to ground fault. ZnO arresters are widely used to protect DC electric traction vehicles against overvoltages caused by lightning or switching surges. However, the arresters are deteriorated by commercial overvoltages and/or lightning one. The deteriorated arresters could lead power failures, such as line to ground fault by a thermal runaway resulting from the increases in leakage current even in a nominal power system voltage. Finally, the power failures would be causative of the fire accident.

CGS 공법에 의한 지반침하억제 사례연구 (A Case Study on the Plan for Settlement Restraint by CGS)

  • 천병식;여유현;김우종;황성식;김우철
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.611-618
    • /
    • 2002
  • In this study the CGS as an injection method by low slump mortar was performed the pilot test to confirm the applicability of this method and the effectiveness of settlement restraint. From the results, there has been concluded the construction control standard such as an institutional diameter, space, depth, injection materials, Infection pressure etc. Also, there has been estimated the ground improvement effectiveness which has resulted from the field investigation and consolidation test etc. From the results, in the adjacent ground the CGS, generally, has been confirmed to in-crease ground strength to improve the consolidation characteristic obtained from the field investigation and consolidation test. Especially, the CGS which performed the larger stiffness to the ground has been concluded that the settlement restraint to the ground complicates the ground effect which Increases the bearing capacity and stress assignment. So, the CGS can be considered as an effective method to increase the bearing capacity as well as the settlement restraint of soft ground.

  • PDF