복사패널이 적용된 건물일체형 지열원 시스템의 난방성능 분석 (Heating Performance Analysis of Building Integrated Geothermal System With Radiant Floor Heating)

  • 김상진;이진욱;김태연;이승복
    • 한국태양에너지학회 논문집
    • /
    • 제32권5호
    • /
    • pp.25-30
    • /
    • 2012
  • Ground source heat pumps(GSHPs) are among the most efficient and comfortable heating and cooling technologies currently available, because they use the earth's natural heat to provide heating, cooling, and often, water heating. And Building Integrated Geothermal System(BIGS) is one of GSHPs which install ground heat exchanger(GHE) in energy pile without borehole to save the investment cost. Therefore, the experiment is to evaluate the heating performance of BIGS in Korea. The experimental results indicate that the average heat pump COP and overall system's COP values are approximately 4.4 and 3.0 in one week. This study shows that the BIGS could be used for heating in Korea.

지열원 히트펌프를 이용한 도로융설시스템의 CFD 성능예측에 관한 기초연구 (A Basic Study on the Performance CFD simulation of Road Snow-melting system by Ground Source Heat Pump)

  • 최덕인;김중현;김진호;황광일
    • 한국지열·수열에너지학회논문집
    • /
    • 제6권2호
    • /
    • pp.23-28
    • /
    • 2010
  • Fluent ver.6.3 is used as CFD(Computational Fluid Dynamics) simulator to predict the performance of snow-melting system by geothermal pipes energy. As the results of this simulation, it is clearly shown that $50^{\circ}C$ of working fluid in to geothermal evaluated as more effect comparing to $45^{\circ}C$ of working fluid. The Surface temperature is come to $5^{\circ}C$ at 1m/s speed and $50^{\circ}C$ temperature of the working fluid.

개방형 지열 시스템 설계법 개발을 위한 관정 주위 지중 온도 환경 검토 (Study on the Underground Thermal Environment around Wells for a Design Method of Open-Loop Geothermal System)

  • 배상무;김홍교;김현우;남유진
    • 한국지열·수열에너지학회논문집
    • /
    • 제13권1호
    • /
    • pp.14-20
    • /
    • 2017
  • Groundwater heat pump (GWHP) system can achieve higher performance of the system by utilizing heat source of the annual constant groundwater temperature. The performance of GWHP system depends on the ground thermal environment such as groundwater temperature, groundwater flow rate and hydraulic conductivity. In this study, the geothermal environment was analyzed by using numerical simulation for develop the two-well geothermal system. As the result, this paper shows the change of the groundwater level and underground temperature around wells according to the conditions of flow rate and hydraulic conductivity.

지중열 교환기와 빙축열조(Thermal Ice Storage)를 연계시킨 통합 지중열-빙축열조 시스템(Integrated GEO/TES) (A Study on An Integrated GEO/TES with Geothermal Heat Exchanger and Thermal Ice Storage)

  • ;한정상;한혁상;한찬;김형수
    • 자원환경지질
    • /
    • 제38권6호
    • /
    • pp.717-729
    • /
    • 2005
  • 일반적으로 대규모 건물의 피크 냉방 부하는 난방부하보다 크다. 북위도의 한냉한 지역에 소재한 대규모건물의 냉난방 설비는 건물 내부에서 생성되는 발열량과 태양으로부터 획득되는 열량에 따라 좌우된다. 최대 냉방부하에 적합하도록 냉난방설비와 지중루프를 설치하는데 소요되는 비용은 일반적으로 초기투자비가 적게 드는 전통적인 HVAC시스템에 비해 다소 고가이다. 빙축열조(Thermal ice storage, TES)시스템은 과거 수년동안 일반 HVAC에서 냉동기의 용량을 축소시키거나 최대 전력부하 시간대를 바꾸기 위해 사용되어온 기술이다. 일반적으로 건물 난방을 위해서는 보일러와 같은 전통적인 난방설비를 이용하고 그 다음날의 건물냉방을 위해서는 전력료가 저렴한 야간에 빙축을 시키는 빙축열기법을 이용한다. 얼음에서 추출한 잠열 에너지의 장점을 이용하기 위해 설계된 분배시스템(distribution system)과 열원과 열배출원(열침, sink)대신에 지중열 교환기(지중루프)를 이용하면 많은 장점이 있다. 공간 난방과 급탕을 공급하기위한 분리형 설비를 별도로 사용하지 않아도 된다. 공간난방용으로 소요되는 설비용량을 축소시킬 수 있으며-소요 지중열 교환기의 규격과 비용을 절감시킴은 물론 지열 HVAC시스템의 효율을 배가 시킬 수 있으며 온실가스 배출량을 대폭 감축시킬 수 있다. 또한 TES를 적용하면 대규모 건물의 냉난방부하와 열펌프의 용량을 $40\~60\%$ 정도 감축시킬 수 있으며 설비대수와 기계실 공간을 줄일 수 있다. 뿐만아니라 피크 냉난방부하를 토대로 설계한 지원 열펌프 시스템(Ground source heat pump system)의 지중루프를 $1/4\~1/3$가지 줄일 수 있어 도심지역에서 지중루프를 설치할 때 장애요인인 지중루프 설치공간문제와 지중암석의 열적특성문제를 동시에 해결할 수 있다.문이며, 따라서 $^{137}Cs$의 분포는 광물분포 보다는 TOC의 함량에 더 큰 영향을 받고 있음을 보여준다.과 위기 고조 단계, 그리고 갈등 해소 단계등 모든 시기에서 두 신문의 주요 행위자 구성에 있어서 차이가 나타났다. 다시 말해, 조선일보는 기본적으로 총파업을 둘러싼 문제의 구성과 발전, 해소 과정에서 정당이나 대통령, 야당 지도자 등과 같은 정치관련 행위자를 강조하고 있었다. 반면에, 한겨레는 대체로 로든 사건진행 단계에서 노동 관련 단체들과 시민단체의 역동적인 연대와 활동에 초점을 맞추고 있는 것으로 나타났다.술 후 24시간에 599.4$\pm$145.6, 678.8 $\pm$256.4였다(t-test, p < 0.05). 동종 수혈은 RAP군에서 34명 중 7명에서(20.6$\%$), 대조군에서는 46명중 16명에서(34.8$\%$) 시행되어, RAP군에서 유의하게 빈도가 낮았다(Chi-square test, p < 0.05). 결론: 역행성 자가 충전법은 심폐바이패스의 충전에 의한 혈액희석을 최소화함으로서, 개심술 후 출혈과 동종수혈을 또한 줄이는 데 효과적인 방법이 될 수 있다고 생각된다.타내지 않았다.성 교사, 가정 전공 교사가 그렇지 않은 교사보다 해석적, 해방적 행동목표를 더 중요하게 인식하고 있었다. 특히 가정교육 철학을 배운 경험이 있는 교사가 그렇지 않은 교사보다 해방적 행동체계 목표를 중요시하는 것으로 나타났다. 이 연구 결과는, 실천 비판적인 가정 교과의 본질을 구현하기 위해서는 주생활 영역의 교육과정에 기술적, 해석적, 해방적 행동에 대한 목표들을 고루 포함하여야 하며 특히 교사들이 중요하게 인식하는 해방적 행동에 대한 목표를 강조하여 적용할 필요가 있음을 시사하고 있다.교하여 유의한 차이가 관찰되지 않았다. 또한

지열원 물대공기 멀티 히트펌프의 냉방 운전 특성에 관한 실증 연구 (Verification Experiment of a Ground Source Multi-heat Pump at Cooling Mode)

  • 최종민;강신형;최재호;임효재;문제명;권영석;권형진;김록희
    • 설비공학논문집
    • /
    • 제21권5호
    • /
    • pp.297-304
    • /
    • 2009
  • The aim of this study is to investigate the cooling performance of ground source multi-heat pump systems with a vertical single U-tube GLHX(U-tube system) and a vertical double tube GLHX(double tube system), which were installed in a school building located in Cheonan. All systems were operated in a part load conditions for all day, and the maximum COP of the single U-tube system and the double tube system were 6.2 and 5.2 at cooling mode, respectively. The double tube GLHX designed by the GLHEPRO, commercial program, was estimated to have the same performance as the U-tube GLHX, because the inlet temperatures of each outdoor unit heat exchanger for the former was similar to the latter. However, it is needed to prove the long tenn performance. It is suggested that the new algorithms to control the flow rate of secondary fluid for GLHX according to load variation have to be developed in order to enhance the performance of the system.

지열히트펌프 시스템의 건물통합설계 및 커미셔닝에 관한 연구 (A Study on Building Integrated Design and Commissioning of GHP System)

  • 김지영;장재철;강은철;장기창;이의준
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.169.1-169.1
    • /
    • 2010
  • Geothermal heat pump(GHP)system has been extensively disseminated due to the recent increasing demand over new and renewable energy. However, the economics and system reliability has been key issues and barriers to insure a better system performance as designed originally. The building integrated designs of geothermal heat pump system are test and optimize GHP system by evaluating its performance in virtual reality. System design is an iterative process that will help optimize the cost efficiency of the system. One of the primary goals is to minimize the energy imbalance between the amount of energy extracted from the ground and the energy reject to it. This will reduce the land area required to install the GHX, reduce the cost of installing it and ensure the long-term efficiency of the system. Commissioning is the process of ensuring that are designed, installed, functionally tested, and capable of being operated and maintained to performance in conformity with design intent. In this paper, Study on introduction of Initial commissioning method of Geothermal Heat Pump(GHP) system using ISO performance data has been introduced. Also KIER GHP Simulator is used to simulate actual heat pimp operating condition and test commissioning method. Result should that the experiment data base could verify the applicability of the commissioning method, and also were able to suggest a better ways to GHP commissioning.

  • PDF

수직밀폐형 지중열교환기의 온도분포 특성 (The Characteristics of Thermal Diffusion With the Vertical-Closed Loop Type Geothermal Heat Exchanger)

  • 선종철;김병철;고영하
    • 한국태양에너지학회 논문집
    • /
    • 제33권1호
    • /
    • pp.57-65
    • /
    • 2013
  • The temperatures with the ground depth, the positions of circulation water in ground heat exchanger were measured and thermal diffusion characteristics with the distances of the direction normal to the borehole was analysed. The deeper the depth of ground, the less the influences of outdoor temperature, but below 10m of ground, there was no influences of ground temperature. When the depth of trench pipe was below the depth of 2m, there was no influence. In the ground of 10m when the distances between the pipe and the other places were above 0.5m, the variations of temperature were less than $1.6^{\circ}C$ and above 2.5m they were less than $0.1^{\circ}C$. When the distances of bore hole were above 5m, there were no. influences of the nearest ground heat exchanger.

양방향 설정온도 제어에 따른 지중연계 히트펌프 시스템의 에너지 절감량 평가 연구 (Two Way Set Temperature Control Impact Study on Ground Coupled Heat Pump System Energy Saving)

  • 강은철;이의준;민경천
    • 한국지열·수열에너지학회논문집
    • /
    • 제10권2호
    • /
    • pp.7-12
    • /
    • 2014
  • Government has recently restricted heating and cooling set temperatures for the commercial and public buildings due to increasing national energy consumption. The goal of this paper is to visualize a future two way indoor set temperature control impact on building energy consumption by using TRNSYS simulation modeling. The building was modelled based on the twin test cell with the same dimension. Air source ground coupled heat pump performance data has been used for modeling by TRNSYS 17. Daejeon weather data has been used from Korea Solar Energy Society. The heating set temperature in the reference room is $24^{\circ}C$ as well as the target room set temperature are $23^{\circ}C$, $22^{\circ}C$, $21^{\circ}C$ and $20^{\circ}C$. The cooling set temperature of the reference room is also $24^{\circ}C$ as well as the target room set temperature of $25^{\circ}C$, $26^{\circ}C$, $27^{\circ}C$ and $28^{\circ}C$. For the air source heat pump system, heating season energy consumption is $35.52kWh/m^2y$ in the reference room. But the heating energy consumption in the target room is reduced to 7.5% whenever the set temperature decreased every $1^{\circ}C$. The cooling energy consumption in the reference room is $4.57kWh/m^2y$. On the other hand, the energy consumption in the target room is reduced to 22% whenever the set temperature increased every $1^{\circ}C$ by two way controller. For the geothermal heat pump system, heating energy consumption in the reference room is reduced to 20.7%. The target room heating energy consumption is reduced to 32.6% when the set temperature is $22^{\circ}C$. The energy consumption in the target room is reduced to 59.5% when the set temperature is $26^{\circ}C$.

부하변동에 의한 지중유효열전도도와 보어홀 전열저항 해석 (Analysis of Effective Soil Thermal Conductivities and Borehole Thermal Resistances with a Power Supply Regulation)

  • 노정근;연광석;송헌
    • 한국태양에너지학회 논문집
    • /
    • 제31권4호
    • /
    • pp.80-86
    • /
    • 2011
  • Investigation of the effective soil thermal conductivity(k) is the first step in designing the ground loop heat exchanger(borehole) of a geothermal heat pump system. Another important factor is the borehole thermal resistance($R_b$). Thermal response tests offer a good method to determine the ground thermal properties for the total heat transport in the ground. This is done by supplying a constant heat power into a borehole heat exchanger. There are two methods to supply a constant heat power. One is to employ the electricity provided by Korea Electric Power Corporation(KEPCO). The other is to use electricity generated by a generator. In this study, the power supply regulation was found to reduce when the electricity generated by the generator was used. This is because the generator evaluated with the power supply characteristically reduces the power supply regulation between an overload and a complex using. But it sometimes occurs a power supply regulation in In-situ thermal response test. In this case getting of k,$R_b$ requires delay times and restored normal state. However, the effect of the delay times and restored normal state on the soil thermal conductivity and borehole thermal resistance is very small. Therefore it is possible to use a generally accepted delay times and restored normal state in the analysis. In this work, it is also shown that an acceptable range of ${\Delta}k$, ${\Delta}R_b$ for normal state and regulation state might be approximately 0.01-0.16W/m k, and -0.004-0.007m K/W, respectively. Thus, restored normal state of power supply regulation is valuable to recommend.

IEA ECBCS Annex 54 방법에 근거한 PVT-GSHP 시스템 경제성 평가 연구 (PVT-GSHP System Economic Evaluation Study with IEA ECBCS Annex 54 Method)

  • 박진우;강은철;이의준
    • 한국태양에너지학회 논문집
    • /
    • 제34권1호
    • /
    • pp.64-71
    • /
    • 2014
  • This study is to perform economic analysis of a PVT-GSHP (Photovoltaic Thermal-Ground Source Heat Pump) system compared to the conventional system which consists of a boiler and a chiller. This research has simulated, developed and analyzed four systems for application in a residential and an office building which was based on the hourly EPI (Energy Performance Index, $kWh/m^2yr$). Case 1 includes a boiler and a chiller to meet heating and cooling demands for a house. Case 2 is the same conventional system as Case 1 for a office. Case 3 is simple summation of Case 1 and 2. And Case 4 is utilizing a PVT-GSHP to meet the combined loads of the house and office. The economic evaluation study was based on IEA ECBCS Annex 54 subtasks C economic assessment methods. This study indicated that PVT-GSHP system can save a building's energy up to 53.9%. Also the SPB (Simple Payback) of the PVT-GSHP system with 0%, 50% initial incentive was 14.5, 6.7 year respectively.