• Title/Summary/Keyword: Ground Facility

Search Result 427, Processing Time 0.027 seconds

A Study on the Hypersonic Air-breathing Engine Ground Test Facility Composition and Characteristics (극초음속 공기흡입식 추진기관 지상 시험설비의 구성 및 특성에 관한 연구)

  • Lee, Yang-Ji;Kang, Sang-Hun;Yang, Soo-Seok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.19 no.6
    • /
    • pp.81-90
    • /
    • 2015
  • In order to know the characteristics of the hypersonic air-breahting engine, high altitude and Mach number ground test is necessary. Therefore, high pressure and high temperature condition should be simulated to do ground test of the hypersonic air-breathing engine. In this paper, the hypersonic air-breathing engine ground test facility of the Korea Aerospace Research Institute was introduced and the composition and characteristics were described.

A Construction Scheme of Control System in a Ground Hot-firing Test Facility (지상연소시험설비의 제어시스템 구축 방안)

  • Lee, Kwang-Jin;Kim, Ji-Hoon;Kim, Seung-Han;Han, Young-Min
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.468-471
    • /
    • 2012
  • This paper describes a construction scheme of hot backup or triple modular redundancy control system in a ground hot-firing test facility to carry out performance assessment of propulsion system used in a space launch vehicle. It was possible for a hot backup redundancy control system with manual operated console to simulate TMR control system. A console layout of control system in control center to restrict imprudent works of operators was proposed.

  • PDF

A study on Locational and Regional Pattern of Leisure Facilities at Kangnam-gu, Seoul (서울시의 활동여가시설의 입지유형에 관한 연구 - 강남구를 중심으로 -)

  • Choi, Woun-Sik;Kim, Min
    • Journal of the Korean Regional Science Association
    • /
    • v.10 no.2
    • /
    • pp.17-29
    • /
    • 1994
  • This study attempts to examine the regional distribution and the locational pattern of leisure facilities at Kangnam-gu in Seoul. For the convenience of the analysis the facilities are classified into public and private sector and then the facilities are classified into 11 types: mineral spring resort, play ground, neighborhood park, swimming pool, gymnasium, bowling, pingpong, aerobic, golf practice, health, and billiard facilities. For the purpose data was collected from statistical yearbook in 1993 and lists of registered facility at department of living physics of Kangnam-gu office. The data of the density of facilities and the opportunity of facilities per facilities type and per region are analysed with the technology of GIS. Results may be summarized as follows. First of all, correlation between the results of Location-Allocation model and the results of Interaction model is very high. Secondly, on comparing the density of facilities with the opportunity of the facility use per eleven facility types, three discrete spatial pattems are found. The mineral spring resort facility type with the highest unbalanced density and opportunity of facility use is to be found. Play ground, neighborhood park, swimming pool, gymnasium, bowling, pingpong, and aerobic facility types have the high unbalanced density and opportunity of facility use. The golf practice, health, and billiard facility types have spatially balanced density and opportunity of facility use. Thirdly, as comparing the density and the opportunity of the facility use per 'dong' administration unit, the spatial patterns of the public and the private facilities are different in density of the facility use and otherwise two are similar in the opportunity of the facility use. Fourthly, patterns of facilities users have different charateristics based on facility use time, expense, residence, and access time and four regional patterns are to be found ; user favorable, facility profitable, user balanced, and unfavorable.

  • PDF

Design and Manufacture of Storage Air Heater (축열식 가열기의 설계 및 제작)

  • Lee, Yang-Ji;Kang, Sang-Hun;Park, Poo-Min;Yang, Soo-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.43-46
    • /
    • 2006
  • Storage air heater(SAH) is a general purpose facility that is used to simulate the high altitude condition of supersonic ground test facility, thurst compensation test of rocket engine nozzle and gas turbine engine combustor test. SAH in KARI is built to simulate the total temperature of the supersonic ground test facility which has a wide flight envelope from altitude 0km, Mach 2 to altitude 25km, Mach 5 and operates up to 1300K, 3.5MPa. In this paper, we introduces the SAH in JAXA which is model of SAH in KARI and summarizes the design process and manufacture of ours.

  • PDF

과학로켓(KSR-III) 비행시험을 위한 추진제 공급설비 개발

  • Kim, Yong-Wook;Cho, Ku-Sik;Kil, Gyong-Sub;Kim, Young-Han;Jung, Young-Suk;Cho, Sang-Yeon;Oh, Seung-Hyub
    • Aerospace Engineering and Technology
    • /
    • v.2 no.1
    • /
    • pp.117-123
    • /
    • 2003
  • This paper introduces ground feeding facility for flight test of sounding rocket(KSR-III) which use liquid propellants and addresses facility configuration, development process and results. Supply of propellants and pressurization gases to vehicle according to predefined launch scenario is the primary goal of ground feeding facility. It was constructed at KSR-III launch site, verified by several tests and used for the flight test successfully.

  • PDF

Develop Test Facility of High Altitude Environment for Kick Motor (Kick Motor용 고공환경 모사 시험 설비 개발)

  • Kim, Sang-Heon;V.A, Bershadskiy;Yu, Byung-Il;Kim, Yong-Wook;Oh, Seung-Hyub;Park, Jeong-Joo
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.707-710
    • /
    • 2008
  • The method suggested in this thesis is the safe and economic method when testing rocket engine because ground test facility copies high altitude. We have decided to use the schematic of testing facility based on already known design method and test result, and we have decided the test condition for ground firing test of solid fuel. In addition the pressure of nozzle exit area is 0.1bar, we have designed the testing facility structure to test in this condition. Moreover, we have designed to reduce the accident probability.

  • PDF

Study on the performance analysis of long-term field test for protected horticulture heating system using solar thermal energy (태양열 시설원예 난방시스템 장기실증 성능분석 연구)

  • Lee Sang-Nam;Kang Yong-Heack;Yu Chang-Kyun;Kim Jin-Soo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.403-407
    • /
    • 2005
  • Objective of the research is to demonstrate solar thermal space and ground heating system which is integrated to a greenhouse culture facility for reducing heating cost, increasing the value of product by environment control, and developing advanced culture technology by deploying solar thermal system. Field test for the demonstration was carried out in horticulture complex in Jeju Island. Medium scale solar hot water system was installed in a ground heating culture facility. Reliability and economic aspect of the system which was operated complementary with thermal storage and solar hot water generation were analyzed by investigating collector efficiency, operation performance, and control features. Short term day test on element performance and Long term test of the whole system were carried out. Optimum operating condition and its characteristics were closely investigated by changing the control condition based on the temperature difference which is the most important operating parameter. For establishing more reliable and optimal design data regarding system scale and operation condition, continuous operation and monitoring on the system need to be further carried out. However, it is expected that, in high-insolation areas where large-scale ground storage is adaptable, solar system demonstrated in the research could be economically competitive and promisingly disseminate over various application areas.

  • PDF

Study on the performance analysis of long-term field test for protected horticulture heating system using solar thermal energy (태양열 시설원예 난방시스템 장기실증 성능분석 연구)

  • Lee Sang-Nam;Kang Yong-Heack;Yu Chang-Kyun;Kim Jin-Soo
    • New & Renewable Energy
    • /
    • v.1 no.2 s.2
    • /
    • pp.53-59
    • /
    • 2005
  • Objective of the research is to demonstrate solar thermal space and ground heating system which is integrated to a green-house culture facility for reducing healing cost, Increasing the value of product by environment control, and developing advanced culture technology by deploying solar thermal system. Field test for the demonstration was carried out in horticulture complex In Jeju Island. Medium scale solar hot water system was installed in a ground heating culture facility. Reliability and economic aspect of the system which was operated complementary with thermal storage and solar hot water generation were analyzed by investigating collector efficiency, operation performance, and control features. Short term day test on element performance and Long term test of the whole system were carried out. Optimum operating condition and its characteristics were closely Investigated by changing the control condition based on the temperature difference which Is the most important operating parameter For establishing more reliable and optimal design data regarding system scale and operation condition, continuous operation and monitoring on the system need to be further carried out. However, It is expected that, in high-insolation areas where large-scale ground storage is adaptable, solar system demonstrated in the research could be economically competitive and promisingly disseminate over various application areas.

  • PDF

An Analysis on Plume Behaviour of Rocket Engine with Ground Condition at High Altitude Engine Test Facility (고공시험설비에서 로켓엔진의 지상시험 플룸 거동 해석)

  • Kim, Seong-Lyong;Lee, SeungJae;Han, YoungMin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.112-115
    • /
    • 2017
  • We analyzed the rocket engine flow to check whether the possibility of the ground test and the equipment safety problems in the high altitude engine test facility. The test condition is that the vacuum chamber is open and the coolant water is injected into the supersonic diffuser. The analysis uses two-dimensional axisymmetry with a mixture of plume, air, and cooling water. As a result, the ground test was possible up to the cooling water flow rate of 200 kg/sec. However, due to the back flow of the initial plume, the vacuum chamber is exposed to high temperature, and at the same time, the inside of the vacuum chamber is contaminated due to the reverse flow of the cooling water. Therefore, sufficient insulation measures and work for pollution avoidance should be preceded.

  • PDF

Logistic Regression and GIS based Urban Ground Sink Susceptibility Assessment Considering Soil Particle Loss (토립자 유실을 고려한 로지스틱 회귀분석 및 GIS 기반 도시 지반함몰 취약성 평가)

  • Suh, Jangwon;Ryu, Dong-Woo;Yum, Byoung-Woo
    • Tunnel and Underground Space
    • /
    • v.30 no.2
    • /
    • pp.149-163
    • /
    • 2020
  • This paper presents a logistic regression and GIS based urban ground sink susceptibility assessment using underground facility information considering soil particle loss. In the underground environment, the particle loss due to water flow or groundwater level change leads to the occurrence and expansion of cavities, which directly affect the ground sink. Four different contributory factors were selected according to the two underground facility domains (water pipeline area, sewer pipeline area) and subway line area. The logistic regression method was used to analyze the correlation and to derive the regression equation between the ground sink inventory and the contributory factors. Based on these results, three ground sink susceptibility maps were generated. The results obtained from this study are expected to provide basic data on the area susceptible to ground sink and needed to safety monitoring.