• 제목/요약/키워드: Grid use

검색결과 947건 처리시간 0.023초

Active Damping Method Using Grid-Side Current Feedback for Active Power Filters with LCL Filters

  • Tang, Shiying;Peng, Li;Kang, Yong
    • Journal of Power Electronics
    • /
    • 제11권3호
    • /
    • pp.311-318
    • /
    • 2011
  • LCL filters installed at converter outputs offer a higher harmonic attenuation than L filters. However, as a three order resonant circuit, it is difficult to stabilize and has a risk of oscillating with the power grid. Therefore, careful design is required to damp LCL resonance. Compared to a passive damping method, an active damping method is a more attractive solution for this problem, since it avoids extra power losses. In this paper, the damping capabilities of capacitor current, capacitor voltage, and grid-side current feedback methods, are analyzed under the discrete-time state-space model. Theoretical analysis shows that the grid-side current feedback method is more suitable for use in active power filters, because it can damp LCL resonance more effectively than the other two methods when the ratio of the resonance and the control frequency is between 0.225 and 0.325. Furthermore, since there is no need for extra sensors for additional states measurements, this method provides a cost-efficient solution. To support the theoretical analysis, the proposed method is tested on a 7-kVA single-phase shunt active power filter.

단상 계통연계형 태양광 발전 시스템의 직류링크 맥동전압 보상 (DC link Ripple Voltage Compensation of a Single-phase Grid-Connected PV System)

  • 이재근;최종우
    • 전력전자학회논문지
    • /
    • 제17권5호
    • /
    • pp.377-387
    • /
    • 2012
  • A single-phase grid-connected PV system is known as suitable for housing of less than 3 kW. The DC link voltage in a single-phase PV system has necessarily twice component of fundamental wave. It makes high THD in the grid current. According to the problem, power quality is lower. Many engineers have studied about this problem. The most simple method is to use low pass filter on DC link voltage control. However it is affected by DC link voltage control bandwidth. If cutoff frequency is reduced to increase the performance of low pass filter, it also lowers DC link voltage control bandwidth. Second method is using band stop filter, it works good on steady state but not good on transient state. This paper proposes the new method for removing ripple voltage to get an exact current reference. It improves the responses on steady state and transient state. The performance was verified through computer simulation using MATLAB and actual experiments.

격자기반의 운동파 강우유출모형 개발(II) - 적용 예(연천댐 유역을 대상으로) - (Grid-Based KlneMatic Wave STOrm Funoff Yoncheon Dam watershed.)

  • 김성준;채효석;신사철
    • 한국수자원학회논문집
    • /
    • 제31권3호
    • /
    • pp.309-315
    • /
    • 1998
  • 개발한 격자기반의 운동파 강우-유출모형의 적용가능성을 검토하기 위하여 임진강유역내의 연천댐 유역(1,875km2)에 적용하였다. 모형의 입력자료로는 수치고도모형, 하천도, 흐름방향도, 토양도, 토지피복도, 티센망도 등 6개의 도형자료를 이용하였다. '90년 및 '96년도에 발생한 홍수사상과 비교하였는바, 모형의 결과는 양호하였다. 출력결과인 시간별 지표유출 분포도로부터 유역에서 발생된 유출양상을 공간적으로 확인할 수 있었다.

  • PDF

지진파 전파 모의를 위한 불균등 격자 및 시간간격 유한차분법 (Discontinuous Grids and Time-Step Finite-Difference Method for Simulation of Seismic Wave Propagation)

  • 강태섭;박창업
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 춘계 학술발표회논문집
    • /
    • pp.50-58
    • /
    • 2003
  • We have developed a locally variable time-step scheme matching with discontinuous grids in the flute-difference method for the efficient simulation of seismic wave propagation. The first-order velocity-stress formulations are used to obtain the spatial derivatives using finite-difference operators on a staggered grid. A three-times coarser grid in the high-velocity region compared with the grid in the low-velocity region is used to avoid spatial oversampling. Temporal steps corresponding to the spatial sampling ratio between both regions are determined based on proper stability criteria. The wavefield in the margin of the region with smaller time-step are linearly interpolated in time using the values calculated in the region with larger one. The accuracy of the proposed scheme is tested through comparisons with analytic solutions and conventional finite-difference scheme with constant grid spacing and time step. The use of the locally variable time-step scheme with discontinuous grids results in remarkable saving of the computation time and memory requirement with dependency of the efficiency on the simulation model. This implies that ground motion for a realistic velocity structures including near-surface sediments can be modeled to high frequency (several Hz) without requiring severe computer memory

  • PDF

Transient-Performance-Oriented Discrete-Time Design of Resonant Controller for Three-Phase Grid-Connected Converters

  • Song, Zhanfeng;Yu, Yun;Wang, Yaqi;Ma, Xiaohui
    • Journal of Power Electronics
    • /
    • 제19권4호
    • /
    • pp.1000-1010
    • /
    • 2019
  • The use of internal-model-based linear controller, such as resonant controller, is a well-established technique for the current control of grid-connected systems. Attractive properties for resonant controllers include their two-sequence tracking ability, the simple control structure, and the reduced computational burden. However, in the case of continuous-designed resonant controller, the transient performance is inevitably degraded at a low switching frequency. Moreover, available design methods for resonant controller is not able to realize the direct design of transient performances, and the anticipated transient performance is mainly achieved through trial and error. To address these problems, the zero-order-hold (ZOH) characteristic and inherent time delay in digital control systems are considered comprehensively in the design, and a corresponding hold-equivalent discrete model of the grid-connected converter is then established. The relationship between the placement of closed-loop poles and the corresponding transient performance is comprehensively investigated to realize the direct mapping relationship between the control gain and the transient response time. For the benefit of automatic tuning and real-time adaption, analytical expressions for controller gains are derived in detail using the required transient response time and system parameters. Simulation and experimental results demonstrate the validity of the proposed method.

가정용 연료전지 시스템의 계통연계 시 수용가 및 배전계통에서의 고조파 영향 평가 (An Assessment on Harmonics Effect in Customer and the Distributed Power System during Grid Connection of Residential Fuel Cell System)

  • 박찬엄;정진수;한운기
    • 전기학회논문지
    • /
    • 제60권6호
    • /
    • pp.1280-1285
    • /
    • 2011
  • Recently, due to the use of fossil fuels for electric power production, carbon emissions increased excessively. Thereby, in order to replace fossil fuels, many studies about fossil fuels such as solar and fuel cell energy source are progressing. Fuel cell system has high energy conversion efficiency. Also, fuel cell system is environmentally friendly system because the carbon emission is almost not occur. Therefore, the fuel cell system is considered as the core technology of in the fields of the future energy and environmental. Fuel cell system has an effect on distribution power system because another power source of other than large power plants. So, fuel cell system can be degradation reason of power quality in the power system. In this paper, we constructed the system for an assessment on harmonics effect. The system is composed with power source, harmonics generation and linear load, fuel cell system. we also performed assessment on harmonics effect in customer and the distributed power system during grid connection of residential fuel cell system. An assessment cases are divided into three. A Case 1 is state that residential load and fuel system are connected to grid, Case 2 is state that residential load and harmonics load are connected to grid, and Case 3 is state that all loads are connected to grid. As a output of fuel cell system is increase, analysis results based on assessment system showed that power quality became more aggravation as effect of harmonics.

스마트그리드 네트워크에서 가용성 보장 메커니즘에 관한 연구: 신호정보를 이용한 공격 및 공격노드 검출 (Study on Availability Guarantee Mechanism on Smart Grid Networks: Detection of Attack and Anomaly Node Using Signal Information)

  • 김미희
    • 정보보호학회논문지
    • /
    • 제23권2호
    • /
    • pp.279-286
    • /
    • 2013
  • 최근 전력 수요의 급증으로 인한 전력난은 효율적 전력 사용을 위한 스마트그리드 기술의 중요성을 부각시키고 있다. 스마트그리드 네트워크의 필수구성요소인 스마트미터기의 가용성 취약점에 대한 실험적 내용이 보고되고 있다. 따라서 안전한 스마트그리드의 실현가능성을 위한 가용성 보호 메커니즘 고안이 필수불가결하다. 본 논문에서는 스마트그리드 구조 및 트래픽패턴의 특징 분석을 통해 스마트미터기에 대한 가용성 침해 공격을 탐지하고, 이상 트래픽을 발생하는 공격노드를 검출할 수 있는 메커니즘을 제안한다. 제안하는 탐지 메커니즘은 공격 탐지를 수행하는 시스템의 탐지 부하를 줄이고 적은 샘플 수에도 높은 탐지율을 제공하기 위해 근사엔트로피 기법을 사용한다. 또한 공격노드가 공격트래픽에서 변경할 수 없는 물리정보(CIR 또는 RSSI 등)를 이용하여 공격 탐지 및 공격노드 검출을 수행한다. 마지막으로 본 논문 제안 기법에 대한 시뮬레이션 결과, 탐지 성능과 실현가능성을 보인다.

스마트 그리드를 위한 소규모 전력에너지 관리 시스템 개발에 관한 연구 (A Study on Development of Small Scale Electric Power Management System for Smart Grid)

  • 이창수;오해석
    • 한국산학기술학회논문지
    • /
    • 제13권6호
    • /
    • pp.2826-2832
    • /
    • 2012
  • 스마트 그리드는 기존에 발전소에서 전력을 일방적으로 공급하는 단방향 전력망에 정보기술을 접목하여 전력 공급자와 소비자가 양방향으로 실시간 정보를 교환함으로써 에너지 효율을 최적화하는 방식이다. 스마트그리드의 전력 관리 시스템은 동적인 가격제도와 함께 소비자들에게 전력사용에 대한 정보를 제공함으로써, 수요의 반응을 유도하고, 전력 계통의 투자와 운영에 있어 효율을 향상시키는데 있다. 하지만, 최근 전력 관리 시스템들은 실시간 가격 등 가격 제도에 주로 초점을 두고 있다. 본 논문에서는 가격 제도에 초점을 둔 기존 전력관리 시스템을 개선하여 전력 사용의 효율성에 초점을 둔 전력에너지 운영 관리 시스템을 제안한다. 전력 데이터는 배전반에 설치된 PMU(Phasor Measurement Units)를 통해 수집되며 데이터 마이닝 기법을 통한 분석 방법으로 효율성 높이고자 한다. 또한 전력 부족 및 과잉 공급 시 PMU와 양방향 통신을 통해 제어할 수 있도록 구현 및 실험하여 전력에너지 관리시스템의 효율성을 입증하였다.

모바일그리드에서 모바일장치의 이용패턴을 고려한 작업 스케줄링 기법 (Job Scheduling Method Considering the Utilization Patterns of Mobile Devices in Mobile Grid)

  • 송성진;정순영;유헌창
    • 컴퓨터교육학회논문지
    • /
    • 제11권3호
    • /
    • pp.91-99
    • /
    • 2008
  • 최근 무선 네트워크의 보급이 활성화 되고, 모바일 장치의 이용이 보편화되면서 모바일 장치의 자원을 그리드 컴퓨팅에 이용하는 모바일 그리드가 대두되었다. 그러나 모바일 환경은 무선네트워크의 불안정성이나 장치의 이동으로 인한 연결 끊김 등의 제약 사항이 있다. 모바일장치에 작업을 할당하는 스케줄링 기법은 모바일 장치의 제약사항을 극복하는데 초점을 둔다. 기존 모바일그리드의 스케줄링 기법은 모바일 장치의 통신 접속 시간에 초점을 두었다. 그런데 모바일장치의 통신 접속 시간은 학교의 수업/방학기간이나 주중/주말 같은 모바일장치 이용자의 생활환경에 따라서 일정한 이용 패턴이 나타난다. 따라서 본 논문에서는 모바일장치의 이용에 대한 통계를 통해 모바일장치의 이용패턴을 분석하였고, 도출된 이용패턴을 고려한 글로벌 스케줄링 기법과 로컬 스케줄링 기법을 제안하였다.

  • PDF

Micro-Grid 시스템에서 Peak-Shaving을 이용한 PV+ 시스템의 최적 운영 방법 (Optimal Operating Method of PV+ Storage System Using the Peak-Shaving in Micro-Grid System)

  • 이지환;이강원
    • 산업경영시스템학회지
    • /
    • 제43권2호
    • /
    • pp.1-13
    • /
    • 2020
  • There are several methods of peak-shaving, which reduces grid power demand, electricity bought from electricity utility, through lowering "demand spike" during On-Peak period. An optimization method using linear programming is proposed, which can be used to perform peak-shaving of grid power demand for grid-connected PV+ system. Proposed peak shaving method is based on the forecast data for electricity load and photovoltaic power generation. Results from proposed method are compared with those from On-Off and Real Time methods which do not need forecast data. The results also compared to those from ideal case, an optimization method which use measured data for forecast data, that is, error-free forecast data. To see the effects of forecast error 36 error scenarios are developed, which consider error types of forecast, nMAE (normalizes Mean Absolute Error) for photovoltaic power forecast and MAPE (Mean Absolute Percentage Error) for load demand forecast. And the effects of forecast error are investigated including critical error scenarios which provide worse results compared to those of other scenarios. It is shown that proposed peak shaving method are much better than On-Off and Real Time methods under almost all the scenario of forecast error. And it is also shown that the results from our method are not so bad compared to the ideal case using error-free forecast.