• Title/Summary/Keyword: Grid noise

Search Result 235, Processing Time 0.029 seconds

Grid Noise Removal in Computed Radiography Images Using the Combined Wavelet Packet-Fourier Method (CR영상에서 웨이블릿 패킷-푸리에 방법을 이용한 그리드 잡음 제거)

  • Lee, A Young;Kim, Dong Youn
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.11
    • /
    • pp.175-182
    • /
    • 2012
  • The scattered radiation always occurs when X-ray strikes the object. To absorb the scattered X-rays, the antiscatter grids are used, however these grids images are superimposed in the projection radiography images. When those images are displayed on the monitor, moir$\acute{e}$ patterns are overlapped over the images and disturb the anatomical informations. Most of the researches performed to date removed the grid noises by calculating or observing those frequencies in one dimensional frequency domain, two dimensional wavelet transform or Fourier transform. Those methods filtered not only the grid noises but also diagnostic informations. In this paper, we proposed the combined wavelet packet-Fourier method to remove the grid artifact in CR images. For the phantom image, the proposed method achieved from 5.2 to 7.4 dB better than others in SNR and for CR images by rejecting the grid noise bands effectively while leaving the remaining bands unchanged, the loss of images could get minimal results.

Vibration Characteristic of a Cylindrical Rod according to the Mounting Locations on the Grid Support Structure (격자 지지구조체에 묶여있는 실린더 형 봉의 삽입위치에 따른 진동특성)

  • Lee, Kang-Hee;Yoon, Kyung-Ho;Song, Kee-Nam;Kim, Jae-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.515-518
    • /
    • 2006
  • A vibration test for a cylindrical rod inserted on the grid support structure was tested using the sine sweep excitation method with closed loop force control. The effect of the mounting location of a test rod on the vibration characteristics of a rod continuously supported by the full size($16{\times}16$) grid support was identified. An electromagnetic vibration shaker, non-contact displacement sensor and HP/VXI data acquisition device were used and TDAS software was also used as a data sampling and processing tools. The natural frequencies and mode shape of the test rod were consistent with the previous works of a rod vibration test with partial grids($3{\times}3,\;5{\times}5\;and\;7{\times}7$). The frequency characteristics of the rod according to the mounting location were shown clear discrepancies, but mode shapes were nearly same. As the test rod closes to the bottom clamping region of the spacer grid, peak vibration amplitudes of the rod become smaller.

  • PDF

Eigenvalue Design Sensitivity Analysis To Redesign Spacer Grid Location In Nuclear Fuel Assembly (핵연료집합체 지지격자 위치결정을 위한 고유치 민감도해석)

  • 박남규;이성기;김형구;최기성;이준노;김재원
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.705-709
    • /
    • 2002
  • The spacer grids in nuclear fuel assembly locate and align the fuel rods with respect to each other. They provide axial and lateral restraint against an excessive rod motion mainly caused by coolant flow. It is understood that each rod Is supported by multiple spacer grid. In such a case, it is important to determine spacer grid span so as to avoid resonance between the natural frequency of the fuel rods and excitation frequency. Actually dynamic characteristics of the fuel rods can be improved by assigning adequate spacer grid locations. When a dynamic performance of the structure is to be improved, design sensitivity analysis plays an important role as like many structural redesign problems. In this work, a shape design concept, different from conventional design, was applied to the problem. According to the theory shape can be a design parameter and optimal shape design can be found. This study concentrates on eigenvalue design sensitivity of the fuel rod supported by multiple spacer grids to determine optimal spacer grids positions.

  • PDF

A Switching Method of Single Phase Grid Connected Inverter for Common Mode Noise Reduction (계통연계형 단상인버터의 Common Mode Noise 저감을 위한 Switching 방법)

  • Lee, Seung-Ju;Hong, Chang-Pyo;Kim, Hag-Wone;Cho, Kwan-Yuhl
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.1
    • /
    • pp.27-33
    • /
    • 2016
  • A pulse-width modulation (PWM) method for common mode noise reduction in a PWM inverter connected to a single-phase grid is proposed in this study. The extensively used conventional switching method may experience common mode voltage problems, which generate current leakage and electromagnetic induction problems. In the proposed switching method, the neutral point of the output voltage is always fixed at both ends of the input voltage to reduce common mode noise. The validity of the proposed method is proven through simulation and experimental results.

Analyzing the Impact of Supply Noise on Jitter in GBPS Serial Links on a Merged I/O-Core Power Delivery Network

  • Tan, Fern-Nee;Lee, Sheng Chyan
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.20 no.4
    • /
    • pp.69-74
    • /
    • 2013
  • In this paper, the impact of integrating large number of I/O (Input-Output) and Core power Delivery Network (PDN) on a 6 layers Flip-Chip Ball Grid Array (FCBGA) package is investigated. The impact of core induced supply noise on high-speed I/O interfaces, and high-speed I/O interface's supply noise coupling to adjacent high-speed I/O interfaces' jitter impact are studied. Concurrent stress validation software is used to induce SSO noise on each individual I/O interfaces; and at the same time; periodic noise is introduced from Core PDN into the I/O PDN domain. In order to have the maximum coupling impact, a prototype package is designed to merge the I/O and Core PDN as one while impact on jitter on each I/O interfaces are investigated. In order to understand the impact of the Core to I/O and I/O to I/O noise, the on-die noise measurements were measured and results were compared with the original PDN where each I/O and Core PDN are standalone and isolated are used as a benchmark.

Noise Removal using Support Vector Regression in Noisy Document Images

  • Kim, Hee-Hoon;Kang, Seung-Hyo;Park, Jai-Hyun;Ha, Hyun-Ho;Lim, Dong-Hoon
    • The Korean Journal of Applied Statistics
    • /
    • v.25 no.4
    • /
    • pp.669-680
    • /
    • 2012
  • Noise removal of document images is a necessary step during preprocessing to recognize characters effectively because it has influences greatly on processing speed and performance for character recognition. We have considered using the spatial filters such as traditional mean filters and Gaussian filters, and wavelet transformed based methods for noise deduction in natural images. However, these methods are not effective for the noise removal of document images. In this paper, we present noise removal of document images using support vector regression. The proposed approach consists of two steps which are SVR training step and SVR test step. We construct an optimal prediction model using grid search with cross-validation in SVR training step, and then apply it to noisy images to remove noises in test step. We evaluate our SVR based method both quantitatively and qualitatively for noise removal in Korean, English and Chinese character documents, and compare it to some existing methods. Experimental results indicate that the proposed method is more effective and can get satisfactory removal results.

Predictive Current Control of a Grid-Connected Inverter with Grid Voltage Observer (계통전압 관측기를 이용한 계통연계형 인버터의 예측전류제어)

  • Lee, Kui-Jun;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.2
    • /
    • pp.159-166
    • /
    • 2010
  • For a grid-connected inverter in distributed generation systems, the current control is essential, and recently, the predictive current control based on a high performance digital signal processors (DSP) to satisfy a fast dynamic response has been widely investigated. However, the performance of predictive current control is degraded by the time delay due to digital implementation, the parameter and measured value errors and the interference of noise, and also theses make system even unstable. Therefore, this paper proposes the predictive current control using grid voltage observer for grid-connected inverter applications. To determine the relevant voltage observer gain, the low-order harmonics of grid voltage are considered, and the effect of filter parameter errors is analyzed. The proposed method has a fast current response capability, the robustness to noise and simple implementation due to voltage sensorless control and the robust current control performance to low-order grid harmonics. The feasibility of the proposed method is verified by simulation and experimental results.

Performance Evaluation of Denoising Algorithms for the 3D Construction Digital Map (건설현장 적용을 위한 디지털맵 노이즈 제거 알고리즘 성능평가)

  • Park, Su-Yeul;Kim, Seok
    • Journal of KIBIM
    • /
    • v.10 no.4
    • /
    • pp.32-39
    • /
    • 2020
  • In recent years, the construction industry is getting bigger and more complex, so it is becoming difficult to acquire point cloud data for construction equipments and workers. Point cloud data is measured using a drone and MMS(Mobile Mapping System), and the collected point cloud data is used to create a 3D digital map. In particular, the construction site is located at outdoors and there are many irregular terrains, making it difficult to collect point cloud data. For these reasons, adopting a noise reduction algorithm suitable for the characteristics of the construction industry can affect the improvement of the analysis accuracy of digital maps. This is related to various environments and variables of the construction site. Therefore, this study reviewed and analyzed the existing research and techniques on the noise reduction algorithm. And based on the results of literature review, performance evaluation of major noise reduction algorithms was conducted for digital maps of construction sites. As a result of the performance evaluation in this study, the voxel grid algorithm showed relatively less execution time than the statistical outlier removal algorithm. In addition, analysis results in slope, space, and earth walls of the construction site digital map showed that the voxel grid algorithm was relatively superior to the statistical outlier removal algorithm and that the noise removal performance of voxel grid algorithm was superior and the object preservation ability was also superior. In the future, based on the results reviewed through the performance evaluation of the noise reduction algorithm of this study, we will develop a noise reduction algorithm for 3D point cloud data that reflects the characteristics of the construction site.

The Fundamental Study for Torsional Vibration of Diesel Generator Set connected Electric Power Grids (전력망에 연결된 디젤 발전기 세트의 비틀림 진동에 대한 기초 연구)

  • Kim, Hyujung;Yun, Hyunwoo;Barro, Ronald D.;Lee, Donchool
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.294-297
    • /
    • 2014
  • A Shipboard power system consists of three or four diesel generator sets connected to a grid. In case of dual fuel diesel generator sets employed LNG ship as a prime mover, large amounts of electricity are required for electric propulsion, auxiliary machinery and accommodation facilities. The electrical connection between generators through a network, torsional vibration can lead power swings. In this paper, the influence on the network by the torsional vibration of diesel generator sets in grid operation were studied. The torsional vibration characteristics were investigated and analyzed through theoretical analysis and the vibration measurement and the results were presented.

  • PDF

Comparison of Images Using Optimized Grid and Images Using Grid Supperession Software in the Diagnosis of Micro Lesions (미세병변 진단에서 Optimized Grid을 사용한 영상과 Grid Supperession Software를 사용한 영상의 비교분석)

  • Lee, Sang-Ho
    • Journal of radiological science and technology
    • /
    • v.41 no.2
    • /
    • pp.149-155
    • /
    • 2018
  • Quantitative analysis was performed to confirm that moire artifact was removed without loss of image when using grid suppression software in the diagnosis of micro lesions. we showed that grid suppression images can be morphologically different from original images as they are significantly lower than those of the optimized grid in the similarity analysis with reference images in mammographic phantom images. We were confirmed that images of microcalcification with smaller signal than noise were lost because the pixel values of all lesions increased significantly after the grid suppression, The change in contrast using the NORMI 13 X-ray test phantom was reduced to 30% of the reference image, This result was significantly lower than the 90% when using the optimized grid. In conclusion, the use of grid suppression software in clinical images should be carefully considered because of the possibility of misdiagnosis due to micro lesion loss and morphological changes.