• Title/Summary/Keyword: Greenhouse heating system

Search Result 200, Processing Time 0.024 seconds

Field Survey of Greenhouse for Strawberry Culture -Case Study Based on Western Gyeongnam Area- (딸기재배 온실의 현장조사 분석 -서부경남 지역을 중심으로-)

  • Jeong, Young Kyun;Lee, Jong Goo;Yun, Sung Wook;Kim, Hyeon Tae;Yoon, Yong Cheol
    • Journal of Bio-Environment Control
    • /
    • v.27 no.3
    • /
    • pp.253-259
    • /
    • 2018
  • This study set out to select a system to realize an optimal environment for strawberry cultivation greenhouses based on data about the growth and development of strawberry and its environment and to provide basic data for the research of its improved productivity. For these purposes, the investigator conducted a field survey with greenhouses for strawberry cultivation in western Gyeongnam. The findings show that farmers in their fifties and sixties accounted for the biggest part in the age groups of strawberry farmers. While those who were under 50 were accounted for approximately 67.5%, those who were 60 or older accounted for 32.5%. As for cultivation experiences, the majority of the farmers had ten years of cultivation experiences or less with some having 30 years of cultivation experiences or more. All the farmers built an arch type single span greenhouse. Those who used nutrient solutions were about 75.0%, being more than those who used soil. All of the farmers that used a nutrient solution adopted an elevated hydroponic system. The single span greenhouses were in the range of 7.5~8.5m, 1.3~1.8m and 2.5~3.5m for width, eaves, and ridge height, respectively, regardless of survey areas. The rafters interval was about 0.7~0.8m. In elevated hydroponic cultivation, the width, height, and interval of the beds were about 0.25m, 1.2m and 1.0m, respectively. As for the strawberry varieties, the domestic ones accounted for approximately 97.5% with Seolhyang being the most favorite one at about 65.0%. As for the internal environment factors of greenhouses, 38 farmers measured only temperature and relatively humidity. As for hydroponics, the farmers used a hydroponics control system. Except for the farmers that introduced a smart farm system for temperature and humidity control, approximately 85.0% controlled temperature and humidity only with a control panel for side windows and ventilation fans. As for heating and heat insulation, all of the farmers were using water curtains with many farmers using an oil or electric boiler, radiating lamp or non-woven fabric, as well, when necessary.

The Technology Development Trends of Supercritical CO2 Power Generation (초임계 CO2 발전 기술개발 동향)

  • Kim, Beom-Ju
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.4
    • /
    • pp.531-536
    • /
    • 2016
  • The worldwide research and development for high-efficiency power generation system is progressing steadily because of the growing demand for reducing greenhouse gas emissions. Many countries have spurred the research and development of supercritical $CO_2$ power generation technology since 2000 because it has the advantage of compactness, efficiency, and diversity. Supercritical $CO_2$ power generation system can be classified into an indirect heating type and a direct heating type. As of now, most studies have concentrated on the development of indirect type supercritical $CO_2$ power generation system. In the United States, NREL(National Renewable Energy Lab.) is developing supercritical $CO_2$ power generation system for Concentrating Solar Power. In addition, U.S. DOE(Department of Energy) also plans to start investing in the development of the supercritical $CO_2$ power generation system for coal-fired thermal power plant this year. GE is developing not only 10MW supercritical $CO_2$ power generation turbomachinery but also the conceptual design of 50MW and 450MW supercritical $CO_2$ power generation turbomachinery. In Korea, the Korean Atomic Energy Research Institute has constructed the supercritical $CO_2$ power generation test facility. Moreover, KEPRI(Korea Electric Power Research Institute) is developing a 2MW-class supercritical $CO_2$ power generation system using diesel and gas engine waste heat with Hyundai Heavy Industries.

The Growth of Cucumber and Variation of Soil Temperature Used by Warming Water Irrigation System (가온관수 시스템에 따른 지온변화와 오이의 생육)

  • 김태욱;김진현
    • Journal of Bio-Environment Control
    • /
    • v.10 no.1
    • /
    • pp.15-22
    • /
    • 2001
  • A soil temperature was known as extremely important factor in terms of measuring the values of the growth and yield of vegetable in the greenhouse. A low temperature water irrigation was had much trouble in its growth. This study was performed to analyze the effect of the heating water irrigation on the soil temperature and the growth of a cucumber within a greenhouse environment. Soil temperature was 5-7$^{\circ}C$ below to 10cm in depth and 2-3$^{\circ}C$ to 20cm when the irrigation water temperature was 13$^{\circ}C$ (non-warme water irrigation). Soil temperature was similar to irrigation water temperature at 5cm in depth and was 1.5-2$^{\circ}C$ below at 10cm when the irrigation water temperatures were 2$0^{\circ}C$, $25^{\circ}C$. The early growth rates of heating water irrigation were 109-110% in plant height, 107-108% in leaf number, 103% in node number compared with those of unheated water irrigation for 30 days after planting it. The rates of total yield were 115% in 2$0^{\circ}C$ water irrigation plots and 121% in $25^{\circ}C$ water irrigation plots while those of unheated water irrigation plots were.

  • PDF

Development of Non-CO2 Emission Factor of the Coal Briquette Boiler (가정용 연탄보일러의 Non-CO2 배출계수 개발)

  • Song, Garam;Cho, Changsang;Lee, Deakyeom;Jeon, Eui Chan
    • Journal of Climate Change Research
    • /
    • v.8 no.2
    • /
    • pp.163-169
    • /
    • 2017
  • In this study, Non-$CO_2$ emission factors were estimated for the coal briquette boiler, which is the Korean heating system. As a result, the $CH_4$ and $N_2O$ emission factors of the coal briquette boiler were estimated to be $11.76gCH_4/TJ$ and $7.44kgN_2O/TJ$, respectively. The results showed that $CH_4$ emission factor was 12 times and $N_2O$ emission factor was 5 times higher than IPCC default value. Also the emission factors developed in this study were compared with a precedent study. The results indicated that were similar to open the air inlet of coal briquette stove because the combustion condition of this study was similar to that of coal briquette stove.

The Development of the Calibration Method of Building Energy Consumption by HDDm and CDDm (냉·난방도일에 따른 건물에너지 사용량 보정기법 개발)

  • Kim, Dongi;Lee, Byeongho
    • Journal of the Korean Solar Energy Society
    • /
    • v.38 no.6
    • /
    • pp.15-26
    • /
    • 2018
  • It is difficult to check the exact building energy consumption reduction such as when green remodeling of buildings, because it is due to outdoor air temperature over the years. And in Korea although Big Data of building energy consumption is collected and managed through "The Information System of the Building Energy and Greenhouse Gases" it is underutilized because of non calibration of outdoor air temperature change. Therefore, this study aims to develope calibration method of building energy consumption by outdoor air temperature according to micro climates, and building use types. As a result of analysis, Regression equations of Building energy consumption and $HDD_m/CDD_m$ are derived and calibration method is developed by Regression coefficient.

Development of a Plasma Heater to Increase Cultivation Environment and Storability of Greenhouse and Non-Storage Pool (온실과 무가온저장고의 재배환경 및 저장성 증가를 위한 플라즈마 히터 개발)

  • Kim, Eung-Kon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.4
    • /
    • pp.761-768
    • /
    • 2019
  • In this paper, the aim is to develop plasma heater products combining the sterilization and purification functions of low-temperature plasma lamp method with the function of vertical heating system using wavelengths of vacuum magnetic (VU). Through this process, the government aims to improve the cultivation environment of crops in greenhouses or facility houses and to increase their storage capacity by increasing the freshness of stored crops such as free-temperature storage. In addition, real-time monitoring technologies will be incorporated that will enable users to identify and respond to changes within greenhouses in real time by utilizing ICT technologies.

A Study on the Thermal Prediction Model cf the Heat Storage Tank for the Optimal Use of Renewable Energy (신재생 에너지 최적 활용을 위한 축열조 온도 예측 모델 연구)

  • HanByeol Oh;KyeongMin Jang;JeeYoung Oh;MyeongBae Lee;JangWoo Park;YongYun Cho;ChangSun Shin
    • Smart Media Journal
    • /
    • v.12 no.10
    • /
    • pp.63-70
    • /
    • 2023
  • Recently, energy consumption for heating costs, which is 35% of smart farm energy costs, has increased, requiring energy consumption efficiency, and the importance of new and renewable energy is increasing due to concerns about the realization of electricity bills. Renewable energy belongs to hydropower, wind, and solar power, of which solar energy is a power generation technology that converts it into electrical energy, and this technology has less impact on the environment and is simple to maintain. In this study, based on the greenhouse heat storage tank and heat pump data, the factors that affect the heat storage tank are selected and a heat storage tank supply temperature prediction model is developed. It is predicted using Long Short-Term Memory (LSTM), which is effective for time series data analysis and prediction, and XGBoost model, which is superior to other ensemble learning techniques. By predicting the temperature of the heat pump heat storage tank, energy consumption may be optimized and system operation may be optimized. In addition, we intend to link it to the smart farm energy integrated operation system, such as reducing heating and cooling costs and improving the energy independence of farmers due to the use of solar power. By managing the supply of waste heat energy through the platform and deriving the maximum heating load and energy values required for crop growth by season and time, an optimal energy management plan is derived based on this.

Study on the Development of Devices for Smart HACCP Systems with WCDMA-LTE Based (WCDMA-LTE 기반의 Smart HACCP 시스템 구축을 위한 단말기 개발에 관한 연구)

  • Jang, Moon-Kee;Park, Jin-Soo
    • Journal of Advanced Navigation Technology
    • /
    • v.18 no.5
    • /
    • pp.490-493
    • /
    • 2014
  • To protect the students from food poisoning, in this paper, it is proposed that the Smart HACCP system which based with WCDMA-LTE to monitoring the temperature and humidity of a freezer, a heating cabinet and kitchen instruments at the elementary, junior and high school. After gathering the data, It is compared with a standard food poisoning index to provide more safe food reserves from the server. Then the server send a index to the terminal which is installed in a kitchen at any school to show the current environment. It is need an WCDMA-LTE terminal to realize smart HACCP system that is proposed from this paper. So, the proposed WCDMA-LTE terminal is designed with using a LTE modem included a 424 MHz wireless modem and a bluetooth 4.0 modem to communicate with other terminals. It can be use the monitoring system of a plastic greenhouse or remotely environment control system.

Development of Economic Culture System Using Wastewater for Microalgae in Winter Season (폐수를 이용한 겨울철 경제적 미세조류 배양 시스템의 개발)

  • Lee, Sang-Ah;Lee, Changsoo;Lee, Seung-Hoon;An, Kwang-Guk;Oh, Hee-Mock;Kim, Hee-Sik;Ahn, Chi-Yong
    • Korean Journal of Environmental Biology
    • /
    • v.32 no.1
    • /
    • pp.58-67
    • /
    • 2014
  • The outdoor mass cultivation is not possible for microalgae in Korea all year round, due to cold winter season. It is not easy to maintain proper level of productivity of microalgae even in winter. To prevent a drastic decrease of temperature in a greenhouse, two layers were covered additionally, inside the original plastic layer of the greenhouse. The middle layer was made up of plastic and the inner layer, of non-woven fabric. Acrylic transparent bioreactors were constructed to get more sunlight, not only from the upper side but also from the lateral and bottom directions. In winter at freezing temperatures, six different culture conditions were compared in the triply covered, insulated greenhouse. Wastewater after anaerobic digestion was used for the cultivation of microalgae to minimize the production cost. Water temperature in the bioreactors remained above $10^{\circ}C$ on average, even without any external heating system, proving that the triple-layered greenhouse is effective in keeping heat. Algal biomass reached to 0.37g $L^{-1}$ with the highest temperature, in the experimental group of light-reflection board at the bottom, with nitrogen and phosphorus removal rate of 92% and 99%, respectively. When fatty acid composition was analyzed using gas-chromatography, linoleate (C18 : 3n3) occupied the highest proportion up to 61%, in the all experiment groups. Chemical oxygen demand (COD), however, did not decrease during the cultivation, but rather increased. Although the algal biomass productivity was not comparable to warm seasons, it was possible to maintain water temperature for algae cultivation even in the coldest season, at the minimum cost.

Net Energy Analysis for Protected Vegetable Production System (시설채소 생산시스템의 순 에너지 분석)

  • 홍지형
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.37 no.1
    • /
    • pp.55-64
    • /
    • 1995
  • This paper presents analytic results of energy sequestered for the forcing cultural Cu- cumber and the others production system with the input-output tables method in the suthern parts of Korea. In this study an attempt is made to evaluate input of direct and indirect energy, output of yield energy and net energy in order to achieve increased energy productivity under P E greenhouse. Cultural practices were grouped soil and soilless with perlite for vegetable production. The results from this study are summarized as follows : 1. Total energy inputs in cucumber production were calculated to be 510 GJ/l0a(di- rect energy : 480 GJ/lOa, indirect energy : 30 GJ/lOa) from soil culture and 440 GJ/ 10a(direct energy : 420 GJ/lOa, indirect energy : 20 GJ/lOa) from soilless culture in perlite hydroponics. 2. Energy outputs from cucumber and biomass were 7 GJ/lOa and 120 GJ/lOa at a uniform rate respectively. 3. Heating fuel as diesel is a major energy inputs approaching 90% of the total energy requirements for cucumber production. 4. Net energy in cucumber production was calculated to be 503 GJ/lOa from soil cul- ture and 431 GJ/lOa from soilless culture. Net energy productivity was maintained costantly as 0.98. 5. Energy productivity in cucumber was calculated to be 0.029 kg/MJ from soil culture and 0.043kg/MJ from soilless culture, while energy efficiency was 0.012 and 0.015 respectively. It is expected that a soilless cultural production system seems to be reduc- tive in seguestered energy input by 13%.

  • PDF