• Title/Summary/Keyword: Green water load

Search Result 70, Processing Time 0.027 seconds

A Study on the Mechanical Change of Emulsion-Treated Hair by Color

  • Ko, Hee-Ja;Park, Jang-Soon
    • Textile Coloration and Finishing
    • /
    • v.34 no.2
    • /
    • pp.127-133
    • /
    • 2022
  • With the increasing interest in the expression of individuality and appearance of modern people, it is time to conduct research and development of novel hair coloring from various angles. Therefore, taking into account the order of discoloration of hair pigments, we selected a creative and novel emulsion as a novel material for hair coloring, rather than a cosmetic material such as hot water extract using natural products dealt with in previous studies, commercially available hair manicure, and oxidation hair dye for hair. Thus, the change in tensile strength and elongation of hair samples by color was studied. As a result of the study, hair with green emulsion paint had a significantly higher maximum load, maximum stress, maximum elongation and breaking load, breaking stress, breaking elongation values are shown. Maximum in terms of modulus, green emulsion applied hair and the control group were higher in the 0-15s strain and 15-145s sections, respectively, and the tangential modulus value was much higher in the control group than the experimental group hairs in all the 0-145s sections. This study, which analyzes the dynamic changes of hair samples that extend the daily color gamut, will greatly contribute to the development of innovative hair coloring materials in the research and production of hair beauty works, and it is judged that it will also contribute to the development of the beauty industry.

Tapping the Potential of Roof Greening and Building a New City-scape

  • Wang, Xiao-yun
    • Journal of the Korean Institute of Landscape Architecture International Edition
    • /
    • no.1
    • /
    • pp.33-36
    • /
    • 2001
  • Only do we have an earth! It is crucially important to improve our living environment and keep the sustained development of a city in the limited space. Some concrete examples will be analysized in the paper, elaborating upon how to make full use of roof space and various plants to create a better green-space. To create different activity space with unique characteristics for people, various plants, roof-space, water and buildings in the style of garden should be use when local conditions and design requirement should be considered.

  • PDF

Relationship Analysis of Reference Evapotranspiration and Heating Load for Water-Energy-Food Nexus in Greenhouse (물-에너지-식량 넥서스 분석을 위한 시설재배지의 기준작물증발산량과 난방 에너지 부하 관계 분석)

  • Kim, Kwihoon;Yoon, Pureun;Lee, Yoonhee;Lee, Sang-Hyun;Hur, Seung-Oh;Choi, Jin-Yong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.61 no.4
    • /
    • pp.23-32
    • /
    • 2019
  • Increasing crop production with the same amount of resources is essential for enhancing the economy in agriculture. The first prerequisite is to understand relationships between the resources. The concept of WEF (Water-Energy-Food) nexus analysis was first introduced in 2011, which helps to interpret inter-linkages among the resources and stakeholders. The objective of this study was to analyze energy-water nexus in greenhouse cultivation by estimating reference evapotranspiration and heating load. For the estimation, this study used the physical model to simulate the inside temperature of the agricultural greenhouse using heating, solar radiation, ventilated and transferred heat losses as input variables. For estimating reference evapotranspiration and heating load, Penman-Monteith equation and seasonal heating load equation with HDH (Heating Degree-Hour) was applied. For calibration and validation of simulated inside temperature, used were hourly data observed from 2011 to 2012 in multi-span greenhouse. Results of the simulation were evaluated using $R^2$, MAE and RMSE, which showed 0.75, 2.22, 3.08 for calibration and 0.71, 2.39, 3.35 for validation respectively. When minimum setting temperature was $12^{\circ}C$ from 2013 to 2017, mean values of evapotranspiration and heating load were 687 mm/year and 2,147 GJ/year. For $18^{\circ}C$, Mean values of evapotranspiration and heating load were 707 mm/year and 5,616 GJ/year. From the estimation, the relationship between water and heat energy was estimated as 1.0~2.6 GJ/ton. Though additional calibrations with different types of greenhouses are necessary, the results of this study imply that they are applicable when evaluating resource relationship in the greenhouse cultivation complex.

An Empirical Study on the Environmentally Friendly Logistics Activities by Industry (업종별 환경 친화적 물류활동에 관한 실증연구)

  • Hong, Sang Tai
    • Journal of the Korea Safety Management & Science
    • /
    • v.21 no.4
    • /
    • pp.81-89
    • /
    • 2019
  • Need to make efforts to reduce greenhouse gas emissions in order to slow global warming is globally recognized and also appealing to the United Nations. The main cause of greenhouse gases is carbon dioxide, and the nation has 23.9 percent of its total emissions in the transportation sector. It was also reported that 61.56 percent of living waste is being recycled, suggesting that environmentally friendly logistics activities should proceed with efforts on goods and services at each stage of distribution. In this study, we conducted a survey of green logistics activities that were environmentally friendly by businesses, divided into management, water/delivery and packaging waste, and identified the status and level of each business sector. As a result, data was collected from 36 manufacturing companies, 28 distribution businesses, and 40 logistics businesses, all of which were 104 companies, and based on the analysis results, a measure for environmentally friendly logistics activities was proposed.

Separation of Caffeine and Catechin Compounds from Green Tea by Quercetin Molecular Imprinted Solid-Phase Extraction (케르세틴 분자각인 고정상 추출을 이용한 녹차에서 카페인 및 카테킨 화합물의 분리)

  • Jin, Yin-Zhe;Row, Kyung-Ho
    • Journal of the Korean Chemical Society
    • /
    • v.51 no.2
    • /
    • pp.165-170
    • /
    • 2007
  • In this work, caffeine and some catechin compounds such as +C, EGC and EGCG were extracted from green tea using quercetin molecular imprinted polymers in solid-phase extraction. For synthesis of MIP, quercetin as the templates, MAA as the monomer, EGDMA as the crosslinker and AIBN as the initiator were used. For extraction of caffeine and catechin compounds from green tea, the solid-phase extractions of a load followed by wash and elution procedures were done with water, methanol and methanol:acetic acid=90:10 (vol.%) as the solvents, respectively. HPLC analysis (C18 column, 5 μm, 250×4.6 mm) with the mobile phase of methanol:water=40:60 (vol.%) at a flow rate of 0.5 ml/min was adopted for the quantitative determination. By solid-phase extraction, the resolutions of caffeine and some catechin compounds from green tea were increased. The quercetin-MIP had higher selectivity to +C compounds.

Runoff Characteristics of Non-Point Source according to Cultivation Activity in River District (하천구역 내 경작활동으로 인한 비점오염물질 유출특성)

  • Ahn, Jae Hwan;Yun, Sang Leen;Kim, Seog Ku
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.7
    • /
    • pp.480-487
    • /
    • 2012
  • The field study was carried out to investigate runoff characteristics of non-point source (NPS) by cultivation activity in river district. Two sites were selected mainly as G region (paddy field, green house), located in Kwangju, Gyeonggi Province, and S region (ordinary field), located in Namyangju, Gyeonggi Province, those belong to Paldang reservoir watershed. The paddy field with water storage capacity showed a slow increase in runoff as rainfall intensity increases. Meanwhile, both green house and ordinary filed revealed a rapid increase. The average BOD runoff concentration of paddy field, green house, and ordinary field was 2.0 mg/L, 2.8 mg/L, 7.9 mg/L, respectively. It indicates that ordinary field shows the highest value in BOD, SS, T-N, and T-P concentration due to the soil loss during rainfall. As a result of runoff load estimation according to the field, a T-N runoff load of paddy field was 1,793.9 kg/year, higher than that of ordinary field. It was estimated that a SS runoff load of ordinary field was 69,704 kg/year and accounts for more than 70% of overall runoff load.

Heating Performance Analysis of Ground-Source Heat Pump (GSHP) System using Hybrid Ground Heat Exchanger (HGHE) (하이브리드 지중열교환기 적용 지열 히트펌프 시스템의 난방 성능 분석)

  • Sohn, Byonghu
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.16 no.3
    • /
    • pp.8-16
    • /
    • 2020
  • This paper presents the heating performance analysis results of a ground-source heat pump (GSHP) system using hybrid ground heat exchanger (HGHE). In this paper, the HGHE refers to the ground heat exchanger (GHE) using both a surface water heat exchanger (SWHE) and a vertical GHE. In order to evaluate the system performance, we installed monitoring sensors for measuring temperatures and power consumption, and then measured operation data with 4 different load burdened ratios of the HGHE. During the entire measurement period, the average heating capacity of the heat pump was 37.3 kW. In addition, the compressor of the heat pump consumed 9.4 kW of power, while the circulating pump of the HGHE used 6.7 kW of power. Therefore, the average heating coefficient of performance (COP) for the heat pump unit was 4.0, while the system including the circulating pump was 2.7. Finally, the parallel use of SWHE and VGHE was beneficial to the system performance; however, further researches are needed to optimize the design data for various load ratios of the HGHE.

Cooling Performance Analysis of Ground-Source Heat Pump (GSHP) System with Hybrid Ground Heat Exchanger (HGHE) (하이브리드 지중열교환기 적용 히트펌프 시스템의 냉방 성능 분석)

  • Sohn, Byonghu
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.14 no.4
    • /
    • pp.43-52
    • /
    • 2018
  • This paper presents the cooling performance analysis results of a ground-source heat pump (GSHP) system using hybrid ground heat exchanger (HGHE). In this paper, the HGHE refers to the ground heat exchanger (GHE) using both a vertical GHE and a surface water heat exchanger (SWHE). In order to evaluate the system performance, we installed monitoring sensors for measuring temperatures and power consumption, and then measured operation data with 4 different load burdened ratios of the hybrid GHE, Mode 1~Mode 4. The measurement results show that the system with HGHE mainly operates in Mode 1 and Mode 2 over the entire measurement period. The average cooling coefficient of performance (COP) for heat pump unit was 5.18, while the system was 2.79. In steady state, the heat pump COP was slightly decreased with an increase of entering source temperature. In addition, the parallel use of SWHE and VGHE was beneficial to the system performance; however, further research are needed to optimize the design data for various load ratios of the HGHE.

Pollutant Delivery Ratio of Okdong-cheon Watershed Using HSPF Model (HSPF 모형을 이용한 옥동천 유역의 유달율 분석)

  • Lee, Hyunji;Kim, Kyeung;Song, Jung-Hun;Lee, Do Gil;Rhee, Han-pil;Kang, Moon Seong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.61 no.1
    • /
    • pp.9-20
    • /
    • 2019
  • The primary objective of this study was to analyze the delivery ratio using Hydrological Simulation Program - Fortran (HSPF) in Okdong-cheon watershed. Model parameters related to hydrology and water quality were calibrated and validated by comparing model predictions with the 8-day interval filed data collected for ten years from the Korea Ministry of Environment. The results indicated that hydrology and water quality parameters appeared to be reasonably comparable to the field data. The pollutant delivery loads of the watershed in 2015 were simulated using the HSPF model. The delivery ratios of each subwatershed were also estimated by the simple ratio calculation of pollutant discharge load and pollutant delivery load. Coefficients of the regression equation between the delivery ratio and specific discharge were also computed using the delivery ratio. Based on the results, multiple regression analysis was performed using the discharge and the physical characteristics of the subwatershed such as the area. The equation of delivery ratio derived in this study is only for the Okdong-cheon watershed, so the larger studies are needed to apply the findings to other watersheds.

Simulations of the Effect of Flow Control and Phosphate Loading on the Reduction of Algae Biomass in Gangjeong-Goryong Weir (유량 조절과 인 부하 변동에 따른 강정고령보 조류저감 효과 수치 모의)

  • Park, Dae-Yeon;Kim, Sung-Jin;Park, Hyung-Seok;Chung, Se-Woong
    • Journal of Environmental Impact Assessment
    • /
    • v.28 no.6
    • /
    • pp.507-524
    • /
    • 2019
  • The purpose of this study was to validate the EFDC model for the weir pool of Gangjeong-Goryong Weir located in Nakdong River, and evaluate the effect of flow control and phosphate loading reduction on the water quality and algae biomass by group (Diatom, Green, Cyanobacteria). As a result of model validation using 2018 experimental data,the time series of water level and vertical distribution of water temperature, DO, organic matter, nitrogen, and phosphorus time series were properly simulated. Seasonal fluctuations of algae biomass by group were adequately reproduced, but the deviations between measured and simulated values were significant in some periods. As a result of scenario simulations to control the water level and flow rate, the thermal stratification was resolved as the water level was lowered and the flow rate increased. The flow velocity at which the water temperature stratification was resolved was about 0.1 m/s, which is consistent with the previous study results of Baekje Weir in Geum River. Simulations of the 2Q flow scenario showed that Chl-a decreased by 8.7% and the cell density of diatom and green algae declined. The cell density of cyanobacteria increased, however, because the high concentrations of cyanobacteria in the upstream boundary conditions directly affected downstream due to increased flow velocity. In the scenario simulation of reducing the influent phosphate load concentration (average 0.056 mg/L) to 50%, Chl-a decreased by 13.6%.The results suggest that the upstream algae concentration and phosphorus load reduction should be considered simultaneously with hydraulic control to prevent algal overgrowth of Gangjeong-Goryong Weir.