• 제목/요약/키워드: Green wall system

검색결과 88건 처리시간 0.021초

Isolation and Characterization of Biofouling Bacteria in Ultra-high Purity Water Used in the Semiconductor Manufacturing Process

  • Kim, In-Seop;Lee, Kye-Joon
    • Journal of Microbiology and Biotechnology
    • /
    • 제10권4호
    • /
    • pp.554-558
    • /
    • 2000
  • Bacteria were isolated and identified from an advanced high-purity water system that supplies ultra-high purity water (UHPW) for 16-megabyte DRAM semiconductor manufacturing. Scanning electron microscopic and microbiological observations revealed that the primary source of the bacteria isolated from the UHPW was detached cells from biofilms developed on the pipe wall through which the UHPW, a man-made and extremely nutrient poor environment, was passing. About 63-65% of the bacteria isolated from the UHPW and the pipe wall were Gram-positive, whereas only 10% of the bacteria isolated from the feed water were Gram-positive. The of Gram-positive bacteria and seven genera of Gram-negative bacteria. Strains of the UHPW bacteria effectively adhered to and formed a biofilm on the surface of polyvinyl chloride (PVC) pipe.

  • PDF

일본의 건축물 녹화 관련제도 연구 (A Study on Related System of Building Greening in Japan)

  • 윤용한;주진희;김원태
    • 한국환경과학회지
    • /
    • 제19권12호
    • /
    • pp.1397-1402
    • /
    • 2010
  • In recently, building greening to improve the urban environment is a very important areas. Thus, in order to promote the building greening is needed for the arrangement of its related system. In this study, analyzed the related system in Japan and the results obtained are as follows. Related system in Japan are to promote the spread of compulsory and dissemination of guidance. And to promote the spread of dissemination of guidance are to allowed a system to be included in green area of the site required, plans to loan the costs of greening, plans to subsidize the cost of greening, tax reduction and exemption, incentive on floor area ratio, plant supply and other technical guidance system. In conclusion, in order to promote the building greening note the related system of Japan and our related system should be arranged.

리기다소나무 방부 정각재를 이용한 목재 옹벽의 강도 성능 평가 (Strength Properties of Wooden Model Retaining Wall Using Preservative Treated Square Timber of Domestic Pinus rigida Miller)

  • 박준철;김건호;이동흡;황원중;홍순일
    • Journal of the Korean Wood Science and Technology
    • /
    • 제38권6호
    • /
    • pp.532-540
    • /
    • 2010
  • 국내산 주요 침엽수 소경목의 활용 방안으로 리기다소나무를 이용한 목재 모형 옹벽을 제작하여 강도 성능을 평가하였다. 목재 모형 옹벽은 가로, 세로 11 cm의 CUAZ-2 처리한 리기다소나무 방부 정각재를 사용하여 3개의 Type으로 제작하였다. 각 Type별 옹벽은 횡목 4층 종목 3층 총 7층의 높이 86 cm, 길이 300 cm, 폭 93 cm로 제작 하였으며 기본형인 Type I과 목재 사용량을 줄이기 위해 중간에 긴 종목과 짧은 종목을 번갈아 사용한 Type II, Type II와 동일하게 제작한 후 횡목의 연결부위를 보강목으로 보강한 Type III으로 제작하였다. 각 Type별 옹벽은 수평 재하 시험을 통한 강도 성능 평가와 화상처리를 통한 구조물의 변형을 검토하였다. 수평 재하 시험 결과 최대 하중을 비교해 보았을 때 Type I은 63.17 kN/m, Type II는 57.80 kN/m, Type III은 60.97 kN/m으로 나타났다. 화상 처리를 통해 측정된 전면부의 최상층 변형을 비교해 보았을 때 Type I에 비해 Type II의 변형이 약 1.5배 많은 변형을 보였으며 Type I과 Type III은 비슷한 변형을 보이는 것을 알 수 있었다. 실험 결과 Type III의 경우 목재 사용량을 절감하면서도 양호한 강도성능을 확인 할 수 있었다.

스마트 그린인프라 기술을 활용한 도로변 미세먼지 저감장치의 성능 및 유지·관리 비용 평가 (Evaluation of Performance and Maintenance Cost for Roadside's Particulate Matter Reduction Devices Using Smart Green Infrastructure Technology)

  • 송규성;석영선;임효숙;전진형
    • 한국환경복원기술학회지
    • /
    • 제25권4호
    • /
    • pp.15-31
    • /
    • 2022
  • The Green Purification Unit System (GPUS) is a green infrastructure facility applicable to the roadside to reduce particulate matter from road traffic. This study introduces two types of GPUS (type1 and type2) and assesses the performance and maintenance costs of each of them. The GPUS's performance analysis used the data collected in November 2021 after the installation of the GPUS type1 and type2 at the study site in Suwon. The changes in the particulate matter concentration near the GPUS were measured. The maintenance cost of GPUS type1 and type2 was assessed by calculating the initial installation cost and the management and repair cost after installation. The results of the performance analysis showed that the GPUS type1, which was manufactured by combining plants and electric dust collectors, had a superior particulate matter reduction performance. In particular, type1 produced a greater effect of particulate matter reduction in the time with a high concentration (50㎍/m3 or higher) of particulate matter due to the operation of electric dust collectors. GPUS type2, which was designed in the form of a plant wall without applying an electric dust collector, showed lower reduction performance than type1 but showed sufficiently improved performance compared to the existing band green area. Meanwhile, the GPUS type1 had three times higher costs for the initial installation than GPUS type2. In terms of costs for managing and repairing, it was evaluated that type1 would be slightly more costly than type2. Finally, this study discussed the applicability of two types of GPUS based on the result of the analysis of their particulate matter performance and maintenance cost at the same time. Since GPUS type2 has a cheaper cost than type1, it could be more economical. However, in the area suffering a high concentration of particulate matter, GPUS type1 would be more effective than type2. Therefore, the choice of GPUS types should rely on the status of particulate matter concentration in the area where GPUS is being installed.

Nonlinear modeling parameters of RC coupling beams in a coupled wall system

  • Gwon, Seongwoo;Shin, Myoungsu;Pimentel, Benjamin;Lee, Deokjung
    • Earthquakes and Structures
    • /
    • 제7권5호
    • /
    • pp.817-842
    • /
    • 2014
  • ASCE/SEI 41-13 provides modeling parameters and numerical acceptance criteria for various types of members that are useful for evaluating the seismic performance of reinforced concrete (RC) building structures. To accurately evaluate the global performance of a coupled wall system, it is crucial to first properly define the component behaviors (i.e., force-displacement relationships of shear walls and coupling beams). However, only a few studies have investigated on the modeling of RC coupling beams subjected to earthquake loading to date. The main objective of this study is to assess the reliability of ASCE 41-13 modeling parameters specified for RC coupling beams with various design details, based on a database compiling almost all coupling beam tests available worldwide. Several recently developed coupling beam models are also reviewed. Finally, a rational method is proposed for determining the chord yield rotation of RC coupling beams.

환기 유무에 따른 CIGS BIPV 커튼월 유닛의 성능 비교 분석 (Comparison of Performance Analysis of the Ventilated and Non-­ventilated CIGS BIPV Units)

  • 김상명;김진희;김준태
    • 한국태양에너지학회 논문집
    • /
    • 제37권2호
    • /
    • pp.47-57
    • /
    • 2017
  • CIGS thin film solar cells are technically suitable for BIPV applications than regularly used crystalline silicon solar cells. Particularly, CIGS PV has lower temperature coefficient than crystalline silicon PV, thus decrease in power generation is lowered in CIGS PV. Moreover, CIGS PV can decrease shading loss when applied to the BIPV system, and the total annual power generation is higher than crystalline silicon. However, there are few studies on the installation factors affecting the performance of BIPV system with CIGS module. In this study, BIPV curtain wall unit with CIGS PV module was designed. To prevent increase of temperature of CIGS PV module by solar radiation, ventilation was considered at the backside of the unit. The thermal specification and electrical performance of CIGS PV of the ventilated unit was analyzed experimentally. Non-ventilated unit was also investigated and compared with ventilated unit. The results showed that the average CIGS temperature of the ventilated curtain wall unit was $6.8^{\circ}C$ lower than non-ventilated type and the efficiency and power generation performance of ventilated CIGS PV on average was, respectively, about 6% and 5.8% higher than the non-ventilated type.

Steel Bar를 이용한 리기다소나무 목재옹벽의 내력 평가 (Strength Evaluation of Pinus rigida Miller Wooden Retaining Wall Using Steel Bar)

  • 송요진;김건호;이동흡;황원중;홍순일
    • Journal of the Korean Wood Science and Technology
    • /
    • 제39권4호
    • /
    • pp.318-325
    • /
    • 2011
  • 현장에서 시공성이 용이함과 동시에 강도 성능이 뛰어난 steel bar를 이용한 리기다소나무 옹벽을 제작하여 내력평가를 실시하였다. Steel bar를 이용한 목재옹벽은 횡목 4단과 종목 3단으로 적층하였으며, 높이 770 mm, 길이 2,890 mm, 폭 782 mm로 제작하였다. 적층 방법은 18 mm로 선공한 최상단과 최하단 횡목을 Steel bar에 삽입하며, 깊이 64 mm, 폭 18 mm의 슬릿을 낸 나머지 횡목과 종목을 Steel bar에 끼워 넣어 적층하였다. 완성 된 옹벽은 수평 재하 시험을 통한 내력 평가와 화상처리(AlCON 3D OPA-PRO system)를 통하여 구조물의 변형을 측정하였다. Steel bar옹벽에는 1개의 긴 횡목과 2개의 종목으로 구성된 접합부(Type-A)와 반턱으로 이음된 2개의 짧은 횡목이 2개의 종목으로 구성된 접합부(Type-B)가 공존하며, 이들을 각각 3개씩 제작하여 접합부의 압축형 전단내력 평가를 실시하였다. Steel bar옹벽의 수평 재하 시험결과 정각재 목재옹벽(박준철 등, 2010)보다 1.6배 이상의 강도를 나타냈으며, 이때 목재와 접합부의 파단은 발생하지 않았다. 접합부의 압축형 전단 내력 실험결과 Type-A의 평균 최대 하중은 130.13 kN, Type-B의 평균 최대 하중은 130.6 kN으로 측정되었다. 실험 결과 Steel bar를 이용한 목재옹벽은 정각재 목재옹벽보다 시공성이 우수하며 강도 또한 높게 측정되었다.

전면 식생형 보강토 옹벽의 표면온도 저감 효과 (Reduction Effect on Surface Temperature of Reinforced Soil Wall with Vegetated Facing)

  • 정성규;이광우;조삼덕;김주형
    • 한국지반환경공학회 논문집
    • /
    • 제14권12호
    • /
    • pp.53-60
    • /
    • 2013
  • 본 연구에서는 장기식생이 가능한 전면 식생형 보강토 옹벽의 식생 환경 적합성을 모니터링하고, 전면벽체 표면온도 측정을 통해 한여름철의 콘크리트 옹벽 전면벽체의 온도 변화를 평가하였다. 이를 위해 장기식생이 가능하도록 식생 포대를 삽입한 특수 블록 벽체를 시공하여 구절초, 맥문동을 포함한 20여 종의 종자 식재 후 2년간 식생 환경을 관찰하였을 뿐만 아니라, 실제 크기의 식생 옹벽을 건설하여 한여름철 식생 및 무식생 옹벽의 전면벽체 표면온도를 비교 분석하였다. 식생 환경 모니터링을 수행한 결과, 장기 식생이 가능한 블록 내에 식재된 대부분의 식물 생장 상태는 양호한 것으로 나타났으며, 식생 포대를 삽입한 블록 벽체가 식물의 성장에 적합한 환경을 제공하는 것으로 나타났다. 또한, 한여름철의 식생 옹벽과 무식생 옹벽의 콘크리트 블록 표면의 온도 변화량을 측정한 결과, 식생 옹벽에 비해 무식생 옹벽의 표면온도가 높게 나타났다. 식생 옹벽의 전면벽체의 경우, 무식생 옹벽의 전면벽체에 비해 표면온도 증가율이 작게 나타난 반면, 냉각율은 더 크게 나타나 장기식생이 가능한 전면 식생형 보강토 옹벽은 식생을 통해 열섬효과를 완화하는데 효과적으로 작용할 수 있을 것으로 판단된다.

A Comparative Analysis of the Energy Load due to Window Area Ratio of Domestic Public Buildings

  • An, Kwang-Ho;Hyun, Eun-Mi;Kim, Yong-Sik
    • KIEAE Journal
    • /
    • 제15권1호
    • /
    • pp.21-27
    • /
    • 2015
  • In the case of public buildings, fast communication and transparency in the administration and the public, as well as ensuring visibility and lighting performance using a glass curtain wall is symbolically expressed through the transparent glass skin. This study is a simulation in order to derive the basic data for the establishment of the improvement of the heating and cooling load analysis according to the window area ratio changes with respect to the high effectiveness of the government's large public building energy consumption analysis and green building certification system of guidelines was analyzed by a change in the energy load. Glass curtain wall is light and visibility, the symbolic meaning of communication, etc., but is widely used in a variety of characteristics, in terms of energy consumption being disadvantaged sheath plan should have been. Design, including the Atrium, is much less energy than energy consumption by the window area ratio. Thus, while compliance with design guide lines, the atrium and I like the burden of a large space ratio and energy load consists of only glass suggest that require more research on that given in the guidelines.

녹색건축인증제(G-SEED)에 따른 한옥의 친환경 요소 평가에 관한 기초연구 -구례 운조루와 진원당을 중심으로- (A basic study on the Eco-friendly elements evaluation of Hanok according to G-SEED -Focus on the Unjoru and Jinwondang-)

  • 최형석;김학래
    • 한국농촌건축학회논문집
    • /
    • 제17권1호
    • /
    • pp.9-18
    • /
    • 2015
  • The purpose of this study is to analyze the usage of eco-friendly elements in Korean traditional architecture to evaluate Hanok(Unjoru and Jinwondang) according to Green Building Certification Criteria(G-SEED). The results of this study were as follows; Unjoru and Jinwondang was not enough to obtain certification points. From Site usage and Traffic category, Jinwondang gets more points than Unjoru. It's because Jinwondang is located in downtown Seoul, so it gets more points of traffic and neighborhood facility. From Energy and Environmental Pollution category, Jinwondang gets more points of energy performance than Unjoru, too. It's because Jinwondang secured insulation performance of wall and windows using insulator and glass. From Resources category, Unjoru gets more points than Jinwondang. It shows that modern Hanok was limited using natural resources. From Ecological Environments category, Jinwondang is located urban area, it's difficult to secure the open space, so Unjoru gets more points than Jinwondang. If Modern Honok installs a system that can getting point and secure insulation performance, it will be certificated according to G-SEED.