• Title/Summary/Keyword: Green Capacity Coefficient

Search Result 21, Processing Time 0.019 seconds

Heating Performance Analysis of Ground-Source Heat Pump (GSHP) System using Hybrid Ground Heat Exchanger (HGHE) (하이브리드 지중열교환기 적용 지열 히트펌프 시스템의 난방 성능 분석)

  • Sohn, Byonghu
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.16 no.3
    • /
    • pp.8-16
    • /
    • 2020
  • This paper presents the heating performance analysis results of a ground-source heat pump (GSHP) system using hybrid ground heat exchanger (HGHE). In this paper, the HGHE refers to the ground heat exchanger (GHE) using both a surface water heat exchanger (SWHE) and a vertical GHE. In order to evaluate the system performance, we installed monitoring sensors for measuring temperatures and power consumption, and then measured operation data with 4 different load burdened ratios of the HGHE. During the entire measurement period, the average heating capacity of the heat pump was 37.3 kW. In addition, the compressor of the heat pump consumed 9.4 kW of power, while the circulating pump of the HGHE used 6.7 kW of power. Therefore, the average heating coefficient of performance (COP) for the heat pump unit was 4.0, while the system including the circulating pump was 2.7. Finally, the parallel use of SWHE and VGHE was beneficial to the system performance; however, further researches are needed to optimize the design data for various load ratios of the HGHE.

A Study on Comparative Analysis of Energy Performance of Hybrid Heat Pump Systems Using Ground Heat Source and Water Heat Source (지열원과 수열원을 이용한 하이브리드 히트펌프 시스템의 에너지 성능 비교 분석 연구)

  • Park, Sihun;Kim, Jonghyun;Min, Joonki
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.17 no.4
    • /
    • pp.59-67
    • /
    • 2021
  • In this study, the performance of the single heat source system and the hybrid system was comparatively analyzed. Case 1 is a ground heat source system, and Case 2 is a water heat source system. Case 3, a hybrid system, reduced the capacity of the ground heat source and applied a water heat source as an auxiliary heat source, and Case 4 was composed of a system that applied a water heat source as an auxiliary heat source to the ground heat source system. As a result of the simulation, in case 3, energy consumption was reduced by up to 2.67% compared to ground sources for cooling. In Case 4, COP was improved by up to 10.02% compared to ground sources during cooling, and EST was calculated to be 2.42℃ lower. During heating, 0.83% was improved compared to the water heat source. At this time, the EST was calculated to be 2.25℃ higher than the water heat source.

Research on Design Capacity Evaluation of Low Impact Development according to Design Criteria (저영향개발 시설 설계 기준에 따른 용량 평가 방법 연구)

  • Im, Jiyeol;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.24 no.1
    • /
    • pp.59-67
    • /
    • 2022
  • The interest in LID facilities is increasing worldwide for recovery of natural water cycle system to destroy by urbanization. However, problems are raised when installation of LID because comprehensive analysis about design capacity adequacy of LID facilities was not conducted completely. In this research, removal efficiency and design volume adequacy of LID facilities were analyzed based on rainfall monitoring data in four LID facilities(Vegetated Swale, Vegetative Filter Strip, Bio-Retention and Permeable Pavement). As a result, group of LID facility designed on WQV was shown higher flow(37%) and pollutants(TSS, BOD, TN and TP) removal efficiencies(20 ~ 37%) than group of LID facility designed on WQF. SA/CA graph was drawn for evaluation of design volume adequacy based on rainfall monitoring data. In this SA/CA graph, coefficient of determination show over 0.5 in all parameter, especially, Flow and TP were show over 0.95. And, 'SA/CA & L/CA' graph considering difference of structure mechanism in LID facility suggested in this research was confirmed that improved coefficient of determination in flow, TSS and TP than SA/CA graph. According to this research results, feasibility of applying 'SA/CA & L/CA' graph for evaluation of design volume adequacy in LID facility, and it is necessary to follow up research for generalization and normalization.

Improvement of Physicochemical Properties and Turfgrass Growth by Root Zone Mixture of Soil Amendment 'Profile' (토양개량제 '프로파일'의 혼합에 따른 토양의 물리화학성 및 한지형 잔디의 생육 개선)

  • Kim, Young-Sun;Lim, Hye-Jung;Ham, Soun-Kyu;Lee, Geung-Joo
    • Weed & Turfgrass Science
    • /
    • v.6 no.3
    • /
    • pp.262-271
    • /
    • 2017
  • This study was conducted to evaluate incorporation ratio of soil amendment 'Profile' to improve soil physicochemical properties and turfgrass growth. The soil amendment was added 0 (sand only), 3, 5, 7, and 10% to USGA Green-spec green sand soil. As incorporated with more 'Profile' amendment, soil electrical conductivity (EC), cation exchangeable capacity (CEC), capillary porosity and total porosity of root zone were increased than those of control, while bulk density and hydraulic conductivity decreased. Turfgrass index and clipping yield of creeping bentgrass grown in sand soil incorporated with 7% 'Profile' were improved than those of control. Correlation coefficient of turf color index and incorporation ratio of the soil amendment 'Profile' was found to show significantly positive correlation. These results indicated that application of the soil amendment 'Profile' to sand soil in golf course green improved turfgrass growth and quality by increasing CEC and porosity of root zone.

Synthesis and Lubricating Properties of Succinic Acid Alkyl Ester Derivatives (숙신산 알킬 에스테르 유도체의 합성 및 윤활특성)

  • Baek, Seung-Yeob;Kim, Young-Wun;Chung, Keun-Wo;Yoo, Seung-Hyun;Park, Su-Jin
    • Applied Chemistry for Engineering
    • /
    • v.22 no.2
    • /
    • pp.196-202
    • /
    • 2011
  • In this paper, a series of alkyl succinic acid esters for base oil were synthesized by condensation reaction of succinic anhydride and fatty alcohol. The structures of the synthesized esters were confirmed by $^1H-NMR$, FT-IR spectrum and GC analysis. Basic properties of esters such as kinematic viscosity (KV), refractive index (RI), total acid number (TAN) and pour points were measured and lubricating properties such as SRV wear scar diameter (SRV WSD), fraction coefficient (COF) and 4-ball wear (4-ball WSD) were also evaluated. As the results of basic properties, KV, RI and pour point of synthetic esters increased as the carbon chain of the esters increased. Measurement value of total acid number (TAN) was indicated between 0.2~4 mgKOH/g, and that metal working fluids and pressure working oils are acceptable to use as base oil. Also, lubricating properties of the esters showed as follows: 0.391~0.689 mm of SRV WSD, 0.110~0.138 of SRV COF and 0.49~0.55 mm of 4-ball WSD depended on the structure of the esters. In a comparison on the lubrication capacity of the SRV test based on polyester TMPTO, SRV WSD result showed that a better performance caused by the alkyl group. On the other hand, SRV COF test was not influenced of the alkyl group which the capacity of the lubricant was sightly diminished than the comparison material, regardless of the alkyl group.

Correlations between Sperm Motility, SCSA (Sperm Chromatin Structure Assay), Reproductive Performance and Heterospermic Fertility in Boars

  • Kim, In-Cheul;Ryu, Jae-Weon;Cho, Kyu-Ho;Hong, Joon-Ki;Choi, Eun-Ji;Choi, Bong-Hwan;Park, Jun-Cheol;Moon, Hong-Kil;Son, Jung-Ho
    • Reproductive and Developmental Biology
    • /
    • v.32 no.2
    • /
    • pp.127-133
    • /
    • 2008
  • The objective of this study was two folds: to investigate the relationship between paternal identification rate and sperm quality parameters such as motility and sperm chromatin structure assay after heterospermic insemination; to see if mutual complement between tests and development of useful technique to enhance the fertility in artificial insemination. In individual boar's fertilizing ability, 3 high fertility boars showed significantly high fertility (p<0.05) compared to 3 low fertility boars, but there was no difference in litter size between two groups. Sperm motility test in pooled and individual semen using computer assisted sperm analysis (CASA) revealed that no significant difference among boars. The high fertile boar showed tendency of low %Red (High red fluorescence/green+red fluorescence) in sperm chromatin structure assay (SCSA) but paternal identification rate from piglets did not differ after heterospermic insemination. The correlation coefficient between individual or pooled semen function test and farrowing rates were well correlated as follows: %Red with litter size (r= - 0.53, p=0.03); %Red with paternal identification rates (r=-0.51, p=0.03); paternal identification rates with litter size (r=0.57, p=0.02). These results indicate that sperm chromatin structure assay and sperm quality parameter test in pooled semen are useful method to predict and evaluate the fertilizing capacity after heterospermic insemination in boars.

The Characteristics of Driving Behavior and Eye-Movement According to Driving Speed and Navigation-Position while Operation of the Navigation in Driving (주행 중 네비게이션 조작 상황에서 주행속도와 네비게이션 위치에 따른 운전행동 및 안구운동 특성)

  • Hong, Seung-Hee;Kang, Jin-Kyu;Kim, Bo-Seong;Min, Cheol-Kee;Chung, Soon-Cheol;Doi, Shun'ich;Min, Byung-Chan
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.34 no.4
    • /
    • pp.35-41
    • /
    • 2011
  • The purpose of this study was to examine drivers' driving behaviors and eye-movements according to driving speed and navigation- position while operation of the navigation in driving. For this purpose, two driving conditions (low-speed and high-speed) and two navigation-positions (top and bottom location of the center console) were set. Drivers' driving behaviors (speed, speed variation, coefficient of variation, and the number of collisions) and eye-movements (overall eye pattern, the average scanning time of navigation, and the number of gaze-out on the road for more 2 seconds) were measured. As a result, when the navigation was located at the bottom of the console, difficulties of lateral control was appeared in low-speed driving condition, and the that of longitudinal control was appeared in high-speed driving condition. In addition, above situation made the drivers' scanning times of navigation long, increased the number of gaze-out on the road for more 2 seconds, and made overall eye pattern monotonous. These results could be interpreted that the manipulation of the navigation at the bottom of console cause reduced attention capacity due to the cognitive load.

Estimation of Soil Moisture and Irrigation Requirement of Upland using Soil Moisture Model applied WRF Meteorological Data (WRF 기상자료의 토양수분 모형 적용을 통한 밭 토양수분 및 필요수량 산정)

  • Hong, Min-Ki;Lee, Sang-Hyun;Choi, Jin-Yong;Lee, Sung-Hack;Lee, Seung-Jae
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.57 no.6
    • /
    • pp.173-183
    • /
    • 2015
  • The aim of this study was to develop a soil moisture simulation model equipped with meteorological data enhanced by WRF (Weather Research and Forecast) model, and this soil moisture model was applied for quantifying soil moisture content and irrigation requirement. The WRF model can provide grid based meteorological data at various resolutions. For applicability assessment, comparative analyses were conducted using WRF data and weather data obtained from weather station located close to test bed. Water balance of each upland grid was assessed for soils represented with four layers. The soil moisture contents simulated using the soil moisture model were compared with observed data to evaluate the capacity of the model qualitatively and quantitatively with performance statistics such as correlation coefficient (R), coefficient of determination (R2) and root mean squared error (RMSE). As a result, R is 0.76, $R^2$ is 0.58 and RMSE 5.45 mm in soil layer 1 and R 0.61, $R^2$ 0.37 and RMSE 6.73 mm in soil layer 2 and R 0.52, $R^2$ 0.27 and RMSE 8.64 mm in soil layer 3 and R 0.68, $R^2$ 0.45 and RMSE 5.29 mm in soil layer 4. The estimated soil moisture contents and irrigation requirements of each soil layer showed spatiotemporally varied distributions depending on weather and soil texture data incorporated. The estimated soil moisture contents using weather station data showed uniform distribution about all grids. However the estimated soil moisture contents from WRF data showed spatially varied distribution. Also, the estimated irrigation requirements applied WRF data showed spatial variabilities reflecting regional differences of weather conditions.

Effect of Activated Carbon, Orpar or Zeolite on Leaching Loss of Fenitrothion, Triadimefon and Diniconazole in Model Green of Golf Course (골프장 모형그린에서 활성탄, Orpar또는 Zeolite의 처리가 Fenitrothion, Triadimefon, Diniconazole의 용탈에 미치는 영향)

  • Oh, Sang-Sil;Koh, Yong-Ku;Chung, Jong-Bae;Hyun, Hae-Nam
    • Applied Biological Chemistry
    • /
    • v.44 no.2
    • /
    • pp.97-102
    • /
    • 2001
  • Cheju island depends on a hydrogeologically vulnerable aquifer system as its principle source of drinking water. Most of golf courses are located in the area which is important for the ground water recharge, and pesticides are applied to golf courses often at relatively high rates. Therefore, turf pesticides in golf course should be applied without adversely impacting ground water. In this experiment, downward movement of pesticides was monitored in model greens of golf course, where different adsorbents were layered in 3-cm thickness at 35-cm depth, and effect of the adsorption layer on the leaching loss of pesticides was investigated. Major leachings were observed in the periods of heavy rain and very limited leaching was observed under artificial irrigation. Fenitrothion and triadimefon, which have relatively short persistence and high adsorption coefficient, were found in the leachate in low concentrations only at the first rainfall event, around 20 days after the pesticide application. However, diniconazole, which has a relatively long half-life (97 days), was detected in the leachate during the whole period of experiment and concentration was much higher than those of the other pesticides. Maximum leachate concentrations were 1.9, 10.3, and 84.5 ${\mu}l^{-1}$ for fenitrothion, triadimefon, and diniconazole, respectively. Therefore, in golf course green which allows rapid water percolation and has extremely low adsorption capacity, persistence in soil could be more important factor in determination of leaching potential of pesticides. Total quantity of pesticides leached from the model green was <0.2% for fenitrothion and triadimefon and 1.8% for diniconazole. Adsorption layers significantly reduced pesticide leaching, and active carbon and Orpar were more effective than zeolite. In the model green having adsorption layer of active carbon or Orpar, leaching loss of pesticides was reduced below 0.01% of the initial application.

  • PDF

A Study on the Planting Design for the Renewal of Urban Neighborhood Park - In Case of Okgu Neighborhood Park, Siheung, Gyeonggi-do, Korea - (도시근린공원 리뉴얼을 위한 식재디자인 연구 - 경기도 시흥시 옥구공원을 대상으로 -)

  • Lee, Sang-Man;Jeong, Moon-Soon;Han, Bong-Ho;Park, Seok-Cheol
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.47 no.1
    • /
    • pp.88-103
    • /
    • 2019
  • This paper aims to identify planting design for the renewal of Okgu Park, located in Siheung, Gyeonggi-do. I designate planting concept fit spatial functions and also suggest planting designs that are proper for a growth environment. The spatial functions of the research site are divided on the basis of the park facilities, its surroundings, and usage. To understand the planting concept, this paper looks into the distribution of plant species and the precise planting structure. To understand the planting concept and the current usage of shade space in the park, I examine the distribution of plant species and the precise planting structure. There are 48 kinds of plants, with Zoysia japonica area (28.84%), Prunus yedoensis (8.0%), Pinus thunbergii (6.73%) and Zelkova serrata (6.38%) taking up the majority. 27 places were chosen for researching the precise planting structure. The research shows that the average green coverage ratio is 38.14% and the average green capacity coefficient is $0.72m^3/m^2$. The growth defective rate of trees in the shade areas is estimated by averaging the classified growth conditions of individual trees per block of shade areas. Areas with an inferior environment for growth and low spatial usage in Okgu Park are selected as subjects for planting design. After comparing the spatial functions with planting concepts and analyzing the growth of plants, I identify $36,236m^2$ areas with inferior growth condition. I also examine structures and the surrounding areas to find areas that require urgent planting improvement, specifically identifying landscape space and shade space around the fountain and the buffer space nearby the North gate. I rearrange spatial functions in the selected areas to devise a planting design considering the existing vegetation, layer structure, and its usage. I set the planting concept and direction to improve the landscape of the selected areas through implementing a planting design so the park users can be satisfied with each space.