• Title/Summary/Keyword: Gosiwon Fire

Search Result 7, Processing Time 0.017 seconds

A Study on Reinforcement of Fire Safety in Residential Spaces of Low-Income Classes (저소득계층 주거 공간 화재안전성 강화를 위한 연구)

  • Park, Nam-Kwon
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.4
    • /
    • pp.882-889
    • /
    • 2021
  • Purpose: The purpose of this study was to improve fire safety in Gosiwon, a residential space for the low-income class. Method: Problems appearing in the process of fire occurrence and damage were verified once again. In addition, we would like to suggest improvement measures through systematic discussions on blind spots. Results: As a result of examining the risk of cool fire, the causes of fire occurred in various ways. In addition, the possibility of radiant heat due to heat accumulation due to narrow rooms inside the Gosiwon was high. Also, it was found that the possibility of fire spread was high due to clothing and household goods. It was reconfirmed that the poor internal structure of a narrow indoor space had a significant effect on the spread of fire and the scale of damage as it tried to accommodate as many people as possible inside. Conclusion: It is necessary to complete the installation as soon as possible for Gosiwon where the simple sprinkler is not installed. For this, a stronger driving force from the government and local governments is needed. In addition, it will be necessary to discuss how to improve the spatial and structural fire vulnerabilities that appear due to the structural characteristics of the Gosiwon.

Analysis of Evacuation Time According to Variation of Evacuation Stairs' Width in Large-Scale Goshiwons (대규모 고시원의 피난계단 폭의 변화에 따른 피난소요시간 분석)

  • Oh, Su-cheol;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.5
    • /
    • pp.641-651
    • /
    • 2022
  • This research compares and analyzes evacuation time depending on the change in stair width in case of fire at Goshiwons. For this, a simulation has been conducted based on possible evacuation time according to the calculation method for the number of people admittable to a specific target for fire fighting equipped with accommodation. Currently, Gosiwon, which is classified as an accommodation facility (a total floor area of 500 m2 or more), uses blind spots prescribed by the Fire Services Act, Building Act, and Parking Act to build a high-rise building on a small area of land, and most Gosiwon is transformed into a modified accommodation. This is in line with the owner's operating profit, so it is expected to show a continuous increase. Securing the golden time of Gosiwon evacuation time is the last bastion of Gosiwon residents who belong to the economically disadvantaged in our society, and we hope this study will serve as a starting point for discussions on revising related laws and regulations to establish a social safety net As a result of the evacuation simulation analysis, the evacuation time was the least when the width of the group and the evacuation stairs were expanded to 200cm, and the evacuation time of the existing building was reduced by up to 166.3 seconds by comparing 648.4 seconds and scenario 6. This analysis can be meaningful, in that the width of the evacuation stairs revision of related laws and regulations for the safety of multiplex available premises.

Analysis on The Characteristics of Occupancy Prediction and The Fire Hazard in Narrow Dwelling Space (협소 거주공간 재실자 특성 및 화재위험성 분석)

  • Lee, Changwoo;Oh, Seungju;Yoo, Juyoul;Kim, Jinsung;Cho, Ahra;Cho, Yongsun
    • Journal of the Society of Disaster Information
    • /
    • v.12 no.4
    • /
    • pp.342-349
    • /
    • 2016
  • The objectives of this study is analysis of the characteristics of fire risk and survey of narrow dwelling space(the Karaoke, Gosiwon etc). The narrow dwelling space has special structure characteristics; the narrow and the complex escape rote. Gosiwon have very separate and exclusive space room, so have the problem a suppression of fire. Furthermore almost Karaokes located in basement have a complex and limitary escape rote. Therefore we should research and development the exploration equipment that search a source of the fire and a emergency rescuer in the scene of the fire.

A Study on the Variation of Evacuation Time according to the Width of Corridor and the Emergency Exit in Gosiwon's Fire State (고시원 화재시 복도 및 비상구 폭에 따른 피난소요시간 변화에 관한 연구)

  • Kim, Jin-Ho;Yang, Jeong-Hoon;Seok, Ho-Tae
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.133-138
    • /
    • 2009
  • The purpose of this study is to present an alternative plan in order to reduce the required time to flee from the inside of the gosiwon in danger. The data were derived from changing the width of corridors and emergency exits and the number of stairs in the building EXODUS, which is computer simulation program, The analyzed conclusions from the data are following as below (1) Increasing the exits and the number of stairs are efficient to reduce the accumulated time for standing by. (2) Increasing the number of stairs is efficient to decrease the distance to get out of the building to exit. (3) Increasing the number of stairs is efficient to reduce the time to get out of the building to exit.

  • PDF

The Evaluation of the Egress Performance in the Buildings Installed with Luminous Egress Guide-lines (건축물내 자체발광식 피난유도선 설치에 따른 피난성능 평가)

  • Park, Yong-Hwan;Kim, Beom-Gyu;Lim, Chae-Hyun
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.120-126
    • /
    • 2011
  • Recently luminous egress guide-lines are introduced for the fire safety of residents in the multi-use buildings such as Gosiwon. Little literature, however, on the quantitative and qualitative estimation for the egress performance of the luminous egress guide-lines can be found. This study carried out experimental investigations to evaluate the egress performance of the existing egress guide-lights and new luminous egress guide-lines. The results showed that both luminous egress guide-lines and egress guide-light satisfied the basic performance of KFI requirements. Under the 7 % smoke transmittance, however, luminous egress guide-lines showed 3 times longer visibility and less evacuation time than egress guide-lights. The evacuation density and smoke transmittance have significant effect on the evacuation time increase without the luminous egress guide-lines, however little effect with the installation.

Fire Characteristic Analysis of Multi-Use Hostels by Using CFAST (CFAST를 이용한 다중이용업소 화재특성 분석연구)

  • Ha, Ji-Soo;Yu, Sang-Yeol;Han, Don-Hee;Kim, Tae-Kwon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.2
    • /
    • pp.339-345
    • /
    • 2010
  • This study has purpose of minimizing damage from fire incident as analyzing the fire characteristic about fire incident of multi-use hostels, which is increasing recently. For this, CFAST, a verified analysis program for the fire incident was employed to prove the logicality of the study by comparing with a established result of the research work and working the fire simulation for an apartment house. On the basis of this, the study will help to improve safety of fire by analyzing the fire characteristic of Karaoke and Gosiwon which are typical model of multi-use hostels and by establishing how to deal with the fire incident.

Fuman behavior during Fire Evacuation in Gosiwon (고시원 화재시 인간 피난행동)

  • Kim, In-Gil;Chung, Yeong-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.400-403
    • /
    • 2012
  • 최근 고시원은 저렴한 방값을 원하는 저소득층의 서민들이 주거하는 공간으로서 불특정 다수가 사용하므로 방화의 위험성을 안고 있다. 본 조사는 이 위험성을 검토하기 위해 SIMULEX 실험을 통하여 고시원 화재시 피난행동을 간접적으로 확인 하고 대비 하는데 도움이 되고자한다. 모형실험 결과 재실자들이 1층 출구 대피시 병목현상을 보였지만 연기의 유동은 위로 상승하기 때문에 3층 재실자들의 빠른 대피가 있다면 인명피해는 없을 것으로 판단된다. 만약 이번 실험 조건이 사람들의 인지능력이 떨어지는 시간 조건을 주고 대피시간이 늦는다면 4, 5층의 재실자는 연기의 빠른 확산으로 인해 많은 인명피해가 발생할 수도 있을 것으로 판단된다.

  • PDF