• Title/Summary/Keyword: Glow curve

Search Result 91, Processing Time 0.025 seconds

The Fabrication and Properties of Ito Transparent Conducting Film for PDP by the Discharge Plasma Analysis (방전플라즈마 해석을 통한 PDP용 ITO 투명전도막의 제작 및 특성)

  • 곽동주;조문수;박강일;임동건
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.10
    • /
    • pp.902-907
    • /
    • 2003
  • In this paper, the ITO thin film, which is considered as one of the most currently used material for the high performance transparent conducting films for the PDP cell, was made in a parallel-plate, capacitively coupled DC magnetron sputtering system. Some electrical and optical properties of ITO films were investigated and discussed on the basis of glow discharge characteristics. The optimized thin film fabricating conditions of Ar gas pressure and substrate temperature were derived from the Paschen curve and glow discharge characteristics. The maximum transmittance of 89.61 % in the visible region and optical band gap of 3.89 eV and resistivity of 1.67${\times}$10$\^$-3/ $\Omega$-cm were obtained under the conditions of 300 C of substrate temperature and 10∼15 mtorr of pressure, which corresponds nearly to that of Paschen minimum.

Characteristics of the Maximum Glow Intensity According to the Thermoluminescent Phosphors used in the Absorbed Dose Measurement of the Radiation Therapy (방사선치료 선량 측정에 사용되는 열형광체에 따른 최대 형광 강도 특성)

  • Kang, Suman;Im, Inchul;Park, Cheolwoo;Lee, Mihyeon;Lee, Jaeseung
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.4
    • /
    • pp.181-187
    • /
    • 2014
  • The purpose of this study were to analyze the characteristic of the glow curves in order to the glow temperature of the thermoluminescent dosimeters (TLDs) for the absorbed dose measurement of the radiation therapy. In this study, we was used the TLDs of the LiF:Mg${\cdot}$Ti, LiF:Mg${\cdot}$Cu${\cdot}$P, $CaF_2$:Dy, $CaF_2$:Mn (Thermo Fisher Scientific Inc., USA). The source-to-solid dry phantom (RW3 slab, IBA Dosmetry, Germany) surface distance was set at 100 cm, and the exposure dose of 100 MU (monitor unit) was used 6- and 15-MV X-rays, and 6- and 12-MeV electron beams in the reference depth, respectively. After the radiations exposure, we were to analyze the glow curves by using the TL reader (Hashaw 3500, Thermo Fisher Scientific Inc., USA) at the fixed heating rate of $15^{\circ}C/sec$ from $50^{\circ}C$ to $260^{\circ}C$. The glow peaks, the trapping level in the captured electrons and holes combined with the emitted light, were discovered the two or three peak. When the definite increasing the temperature of the TLDs, the maximum glow peak representing the glow temperature was follow as; $LiF:Mg{\cdot}Ti$: $185.5{\pm}1.3^{\circ}C$, $LiF:Mg{\cdot}Ti$: $135.0{\pm}5.1^{\circ}C$, $CaF_2$:Dy: $144.0{\pm}1.6^{\circ}C$, $CaF_2$:Mn: $294.3{\pm}3.8^{\circ}C$, respectively. Because the glow emission probability of the captured electrons depend on the heating temperature after the exposure radiation, TLDs by applying the fixed heating rate, the accuracy of measurement will be able to improve within the absorbed dose measurement of the radiation therapy.

Luminescence Identification Characteristics for Irradiated Dried Fishery Products (조사처리한 건조수산품의 전처리 방법에 따른 Luminescence 판별 특성)

  • Kim, Moon-Young;Ahn, Jae-Jun;Kim, Gui-Ran;Kwak, Ji-Young;Park, Kun-Sang;Lee, Kyung-Jin;Kwon, Joong-Ho
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.42 no.11
    • /
    • pp.1837-1842
    • /
    • 2013
  • Photostimulated luminescence (PSL) and thermoluminescence (TL) analyses were conducted for the detection of different gamma-irradiated dried fishes (mussel, squid, beka squid, mitra squid, plaice, and saury) at 0, 1, 5 and 10 kGy. For TL analysis, the contaminating silicate minerals were obtained by density separation or acid hydrolysis treatment. PSL determinations indicated that all the non-irradiated samples showed PSL photon counts/60 s (PCs) lower than 700 PCs (negative), but the irradiated mussel sample at 5 and 10 kGy were only possibility identified showing higher than 5000 PCs (positive). Irrespective of sample kinds and methods of mineral separation, all the non-irradiated samples showed TL glow curves in low-intensity with a maximum peak only after $250^{\circ}C$. However, all the irradiated samples produced TL glow curves in high intensity with a maximum peak particularly in the temperature range of 1$150{\sim}250^{\circ}C$. In conclusion, more distinguishable TL results [glow curve, TL ratio ($TL_1/TL_2$)] were obtained from the marker minerals separated by acid hydrolysis rather than density method.

Detection Characteristics of TL, ESR and DNA Comet for Irradiated Soybeans (열발광, 전자스핀공명 및 DNA Comet 분석에 의한 대두의 방사선 조사 여부 검지 특성)

  • Lee, Eun-Young;Jeong, Jae-Young;Noh, Jung-Eun;Jo, Deok-Jo;Kwon, Joong-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.34 no.1
    • /
    • pp.18-23
    • /
    • 2002
  • The detection characteristics of gamma-irradiated $(0{\sim}4\;kGy)$ soybeans produced in Korea and China were investigated by thermoluminescene (TL), electron spin resonance (ESR), and DNA comet assay. The TL glow curves were shown at around $200^{\circ}C$ for irradiated soybeans, while that at $280^{\circ}C$ for the non-irradiated one. The normalization with a re-irradiation step at 1 kGy could verify the above detection results. The Korean soybean showed higher glow curves than Chinese did. The ESR spectroscopy for husks of irradiated soybeans revealed specific signals (g = 2.02374, 1.98715) derived from cellulose radical, which intensities were proportional to irradiation does, with the higher peaks in Chinese sample than Korean one. The DNA comet for the non-irradiated sample showed no or little tails, while those for irradiated samples above 0.5 kGy were remarkably changed in their length, size, and concentration, thus resulting in distinguishing non-irradiated from irradiated samples. As a result, TL, ESR, and DNA comet determinations were found suitable for the detection of irradiated soybean at 0.5 kGy or more, and negligible differences were observed between Korean and Chinese origins in their detection characteristics.

Luminescence Detection Characteristics for Irradiated Dried Fishes Using PSL-TL System (Photostimulated luminescence-thermoluminescence 분석체계를 이용한 조사 처리된 건어류의 luminescence 판별 특성)

  • Kim, Moon-Young;Kim, Gui-Ran;Ahn, Jae-Jun;Park, Kun-Sang;Kim, Eun-Jeong;Lee, Kyung-Jin;Kwon, Joong-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.45 no.1
    • /
    • pp.8-12
    • /
    • 2013
  • Photostimulated luminescence (PSL) and thermoluminescence (TL) analyses were conducted for the detection of different irradiated dried fishes. All the non-irradiated samples provided PSL counts of lower than 700 (negative: $T_1$). Clear identification of irradiated sample was only possible for irradiated anchovy with PSL counts >5000; however, the results were unsatisfactory (not positive) for irradiated cod, dried filefish, hairtail, and herring samples. The contaminating silicate minerals were obtained by density separation or acid hydrolysis to perform TL analysis, which resulted in a low intensity of TL glow curve with a maximum peak after $250^{\circ}C$ for the non-irradiated samples that are irrespective of their kinds and methods for the mineral separation. The TL glow curves of high intensity with maximum peak in the temperature range of $150-250^{\circ}C$ were observed for all the irradiated samples. However, better results of TL glow curves and particularly of the TL ratio ($TL_1/TL_2$) were obtained when the minerals were separated by a acid hydrolysis method.

Detection of Radiation Induced Markers in Oranges Imported from the United States of America (미국산 오렌지의 Radiation Induced Marker 검색)

  • 조덕조;권중호
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.32 no.1
    • /
    • pp.1-7
    • /
    • 2003
  • Radiation induced markers were investigated for the detection of irradiated oranges imported from America. In the DNA comet assay, the non-irradiated and irradiated samples showed the comets with long tails in both seed and flesh. Though this tendency was maintained for 6 weeks, identification of non-irradiated or irradiated samples was impossible. In the thermoluminescence (TL) measurement, the non-irradiated samples revealed a glow curve with low intensity at about 28$0^{\circ}C$, while the irradiated samples showed with higher intensity at around 18$0^{\circ}C$. There were no remarkable changes in detection properties for 6 weeks after irradiation. The TL ratio of area for TL$_1$ glow curve to TL$_2$ was below 0.1 for the non-irradiated samples and 0.5 or more for the irradiated ones during storage. In the electron spin resonance (RSR) measurement, irradiated oranges showed an unspecific central signal in all parts (seed, flesh and peel), so the detection for radiation treatment of oranges was impossible. Based on the results, DNA comet assay and ESR were not useful for the detection, but TL was appropriate to search radiation induced markers of oranges during storage period. The detectable period during storage is confirmed by sensory evaluation.

Evaluation the Output Dose of Linear Accelerator Photon Beams by Blind Test with Dose Characteristics of LiF:Mg,Cu,P TLD (LiF:Mg,Cu,P 열형광선량계의 선량특성을 이용한 눈가림법에 의한 출력선량 평가)

  • Choi, Tae-Jin;Lee, Ho-Joon;Yie, Ji-Won;Oh, Young-Gi;Kim, Jin-Hee;Kim, Ok-Bae
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.308-316
    • /
    • 2009
  • To achieve the accurate evaluation of given absorbed dose from output dose of linear accelerator photon beam through investigate the characteristics of LiF:Mg,Cu,P TLD powder. This experimental TL phosphor is performed with a commercial LiF:Mg,Cu,P powder (Supplied by PTW) and TL reader (LTM, France). The TLD was exposed to 6 MV X rays of linear accelerator photon beam with range 15 to 800 cGy in blind dose at two hospitals. The dose evaluation of TLD was through the experimental algorithms which were dose dependency, dose rate dependency, fading and powder weight dependency. The glow curve has shown the three peaks which are 110, 183 and 232 degrees of heating temperature and the main dosimetric peak showed highest TL response at 232 high temperature. In this experiments, the LiF:Mg,Cu,P phosphor has shown the 2.5 eV of electron trap energy with a second order. This experiments guided the dose evaluation accuracy is within 1% +2.58% of discrepancy. The TLD powder of LiF:Mg,Cu,P was analyzed to dosimetric characterists of electron captured energy and order by glow shape, and dose-TL response curve guided the accuracy within 1.0+2.58% of output dose discrepancy.

  • PDF

Growth of Li2B4O7 Single Crystal and Its Thermoluminescent Properties (Li2B4O7 단결정 성장과 열형광 특성)

  • Park, Kang-Soo;Ahn, Jung-Keun;Kim, Dong-Jin;Hwang, Yoon-Hwae;Kim, Hyung-Kook;Park, Myeong-Hwan;Kang, Hee-Dong;Kim, Do-Sung
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.1
    • /
    • pp.16-23
    • /
    • 2003
  • Thermoluminescent properties of $Li_2B_4O_7$ single crystal grown by Czochralski method have been investigated. The high quality $Li_2B_4O_7$ single crystal without core was obtained at rotation speed of 10 rpm for seed crystal and pulling speed below $0.18\;mm{\cdot}h^{-1}$. The structure of $Li_2B_4O_7$ single crystal was classified as tetragonal by XRD analysis. The TL glow curve was composed with three overlapped peaks which can be easily deconvoluted and the TL response of $Li_2B_4O_7$ single crystal TLD to X-ray radiation is linear within the range of $50\;mGy{\sim}1.5\;Gy$. Activation energies of three TL glow peaks analyzed by the various heating rates method and PL spectrum were 0.93, 1.78 and 2.25 eV, respectively.

An Integrated System for Radioluminescence, Thermoluminescence and Optically Stimulated Luminescence Measurements

  • Park, Chang-Young;Park, Young-Kook;Chung, Ki-Soo;Lee, Jong-Duk;Lee, Jungil;Kim, Jang-Lyul
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.4
    • /
    • pp.160-169
    • /
    • 2018
  • Background: This study aims to develop an integrated optical system that can simultaneously or selectively measure the signals obtained from radioluminescence (RL), thermoluminescence (TL), and optically stimulated luminescence (OSL), which are luminescence phenomena of materials stimulated by radioactivity, heat, and light, respectively. The luminescence mechanism of various materials could be investigated using the glow curves of the luminescence materials. Materials and Methods: RL/TL/OSL integrated measuring system was equipped with a X-ray tube (50 kV, $200{\mu}A$) as an ionizing radiation source to irradiate the sample. The sample substrate was used as a heating source and was also designed to optically stimulate the sample material using various light sources, such as high luminous blue light emitting diode (LED) or laser. The system measured the luminescence intensity versus the amount of irradiation/stimulation on the sample for the purpose of measuring RL, TL and OSL sequentially or by selectively combining them. Optical filters were combined to minimize the interference of the stimulation light in the OSL signal. A long-pass filter (420 nm) was used for 470 nm LED, an ultraviolet-pass filter (260-390 nm) was used for detecting the luminescence of the sample by PM tube. Results and Discussion: The reliability of the system was evaluated using the RL/OSL characteristics of $Al_2O_3:C$ and the RL/TL characteristics of LiF:Mg,Cu,Si, which were used as dosimetry materials. The RL/OSL characteristics of $Al_2O_3:C$ showed relatively linear dose-response characteristics. The glow curve of LiF:Mg,Cu,Si also showed typical RL/OSL characteristics. Conclusion: The reliability of the proposed system was verified by sequentially measuring the RL characteristics of radiation as well as the TL and OSL characteristics by concurrent thermal and optical stimulations. In this study, we developed an integrated measurement system that measures the glow curves of RL/TL/OSL using universal USB-DAQs and the control program.

Construction of the TLD Readout System Using the Personal Computer and Its Characteristics (PC를 이용한 TLD 판독장치의 제작과 특성조사)

  • U, Hong;Kang, Hee-Dong;Kim, Do-Sung
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.5
    • /
    • pp.342-349
    • /
    • 1998
  • A multipurpose TLD readout system for radiation dosimetry and thermoluminescence study is constructed and its characteristics are investigated. The thermoluminescent lights are measured by a PM tube and the current-to-frequency converter. TLDs are heated by platinum heater and the heating rate is linearly varied. Measurement of the glow curve and control of the whole system have been done by a personal computer equipped with an interface board. The automatic gain control can be done by the control software. The lower detection limit of the system is about $10\;{\mu}Gy$ and dose response is linear.

  • PDF