Trace Mercury Determination by Differential Pulse Anodic Stripping Voltammetry Using Polythiophene-Quinoline/Glassy Carbon Modified Electrode

  • Yoo, Kwang-Sik;Woo, Sang-Beom;Jyoung, Jy-Young
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.1
    • /
    • pp.27-31
    • /
    • 2003
  • A Polythiophene-quinoline/glassy carbon (PTQ/GC) modified electrode was developed for the determination of trace mercury in industrial waste water, natural water, soil, and other media. The electrode was prepared by the cyclic voltammetric polymerization of thiophene and quinoline on glassy carbon (GC) electrode by the potential application from -0.6 V to +2.0 V (50 mV/sec) in a solution of 0.1 M thiophene, quinoline and tetrabutyl ammonium perchlorate (TBAP) in acetonitrile. Optimum thickness of the polymer membrane on the GC electrode was obtained with 20 repeated potential cyclings. The redox behavior of Cu(Ⅱ) and Hg(Ⅱ) were almost identical on this electrode. The addition of 4-(2-pyridylazo)resorcinol (PAR) to the solution containing Cu(Ⅱ) and Hg(Ⅱ) allowed the separation of the components due to the formation of the Cu(Ⅱ)-PAR complex reduced at -0.8V, which was different from the Hg(Ⅱ) reduced at -0.5 V on a saturated calomel electrode (SCE). The calibration graph of Hg(Ⅱ) shows good linear relationship with the correlation factor of 0.9995 and the concentration gradient of 0.33 ㎂/㎠/ppb down to 0.4 ppb Hg. The method developed was successfully applied to the determination of mercury in samples such as river, waste water, and sea water.

Determination of Cobalt(III) Ion Using a Nafion-Ethylenediamine Modified Glassy Carbon Electrode

  • Kim, Seok Jin;Ko, Young Chun
    • Journal of Integrative Natural Science
    • /
    • v.7 no.3
    • /
    • pp.188-192
    • /
    • 2014
  • Determination of cobalt(III) ion with a perfluorinated sulfonated polymer-ethylenediamine (nafion-en) modified glassy carbon electrode is studied. It is based on the chemical reactivity of an immobilized layer, nafion-en, to yield complex $[Co(en)_3]^{3+}$. The reduction peak potential by differential pulse voltammetry (DPV) is observed at $-0.437{\pm}0.047$ V (vs. Ag/AgCl). The linear calibration curve is obtained in cobalt(III) ion concentration range $1.0{\times}10^{-8}{\sim}1.0{\times}10^{-3}M$ ($5.893{\times}10^{-12}{\sim}5.893{\times}10^{-5}g/mL$).

Voltammetric Investigation of Vitamin B_6 at a Glassy Carbon Electrode and Its Application in Determination

  • Wu, Yun-Hua;Song, Fa-Jun
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.1
    • /
    • pp.38-42
    • /
    • 2008
  • The voltammetic behavior of Vitamin B6 (VB6) was studied at a glassy carbon electrode in phosphate buffers using cyclic, linear sweep and differential pulse voltammetry. The oxidation process was shown to be irreversible over the entire pH range studied (4.0-10.0) and was adsorption controlled. The adsorption amount of VB6 on the glassy carbon electrode was examined by chronocoulometry and the value of n, product of transfer coefficient and number of electrons transferred in the rate determining step, was determined from Tafel plot. VB6 was determined by differential pulse voltammetry and the peak current was found linearly with its concentration in the range of 3 10-7-2 10-4 mol L-1. The detection limit was 1 10-7 mol L-1. The procedure was successfully applied for the assay of VB6 in tablets.

Voltammetric Study of Anionic Surfactant-Modified Glassy Carbon Electrode for Bis(2,2'-Bipyridyl)Copper(II) in 200 mM NaBr

  • Ko, Young Chun
    • Journal of Integrative Natural Science
    • /
    • v.7 no.2
    • /
    • pp.120-123
    • /
    • 2014
  • When a hydrophobic and hydrophilic environments of bis(2,2'-bipyridyl) copper(II) ($Cu(bpy)_2{^{2+}}$) are produced in the presence of anionic surfactant sodium dodecyl sulfate (SDS), cyclic voltammetry is used to investigate the microscopic environments which occurs at the glassy carbon electrode. In order to see the relation between ${\Delta}E_p$ and a critical micelle concentration (CMC), ${\Delta}E_p$ vs. -Log[SDS] for the redox couples are plotted. The concentration at the intersection of two lines is 2.57 mM SDS, and this concentration can be determined as the CMC (relative error: below 0.03%; 2.63 mM SDS by surface tensiometry).

Electrochemical Reduction of Oxygen at Co(II)-3,4-bis (salicylidene diimine)toluene Complex supported Glassy Carbon Electrode

  • 최용국;조기형;박경희
    • Bulletin of the Korean Chemical Society
    • /
    • v.16 no.1
    • /
    • pp.21-26
    • /
    • 1995
  • Electrochemical reduction of oxygen has been carried out at glassy carbon electrode and carbon ultramicroelectrode, the surface of which is modified with a new Co(Ⅱ)-Schiff base complex, Co(Ⅱ)-3,4-bis(salicylidene diimine)toluene in 1 M KOH solution. The results obtained from cyclic voltammetric and chronoamperometric experiments are consistent with the formation of the reasonably stable superoxide ions as a primary electron transfer reaction product. The exchange rate constant obtained for oxygen reduction is about 0.02 cm/s.

Electrochemical Reduction of Thionyl Chloride : Catalytic Effects of Metalomacrocyclic Compounds (SOCl$_2$의 전기화학적 환원 : 금속-거대고리 화합물의 촉매효과)

  • Woo-Seong Kim;Yong-Kook Choi;Chjo Ki-Hyung
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.8
    • /
    • pp.744-752
    • /
    • 1993
  • Electrochemical reduction of thionyl chloride has been carried out at glassy carbon and microelectrode that modified by macrocyclic compounds. The catalyst molecules of macrocyclic compounds were adsorbed on the electrode surface and reduced thionyl chloride resulting in a generation of oxidized catalyst molecules. The concentration of catalysts and electrode immersion time were found to affect the catalyst performance strongly. Significant improvements in cell performance have been noted in terms of both exchange rate constants of up to 10 times and power densities of up to 220% at glassy carbon electrode. The diffusion coefficients obtained at carbon microelectrode were slightly different from that determined at glassy carbon electrode.

  • PDF

Electrocatalysis of Oxygen Reduction by Cu-containing Polymer Films on Glassy Carbon Electrodes

  • Kim, Jong-Won;Gewirth, Andrew A.
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.8
    • /
    • pp.1322-1328
    • /
    • 2007
  • The catalytic activity of poly[(2,2'-bipyridine)copper(II)-μ4-oxalato] coated on a glassy carbon electrode (GCE) for O2 electroreduction is examined using cyclic voltammetry and rotating disk electrode techniques. The cyclic voltammograms show that O2 is electroreduced on pBpCuOx-coated GCE surfaces at a peak potential of ? 0.25 V in pH 4.7 acetate buffer media. The electroreduction of O2 on pBpCuOx-coated GCE occurs at 450 mV more positive potential than that found at a bare GCE. The catalytic activity originates from Cu(II) coordinated by bipyridine in the complexes and the polymer type Cu-complex films exhibit an enhanced stability compared to monomeric Cu-complexes during the O2 electroreduction. The rotating disk electrode measurements reveal that the electroreduction of O2 on pBpCuOx-coated GCE is a four-electron process. Kinetic parameters for O2 reduction on pBpCuOx-coated GCE are obtained from rotating disk experiments and compared with those on bare glassy carbon electrode surfaces.

Electrocatalytic Effect of Dioxygen Reduction at Glassy Carbon Electrode Modified with Schiff Base Co(II) Complexes (Schiff Base Co(II) 착물이 변성된 유리질 탄소전극에서 산소 환원의 전기촉매 효과)

  • Seong, Jeong-Sub;Chae, Hee-Nam;Choi, Yong-Kook
    • Analytical Science and Technology
    • /
    • v.11 no.6
    • /
    • pp.460-468
    • /
    • 1998
  • Schiff base ligands such as $SOPDH_2$, $SNDH_2$, $EBNH_2$, and $PBNH_2$ and their Co(II) complexes such as [$Co(II)(SND)(H_2O)_2$], [$Co(II)(SOPD)(H_2O)_2$], [$Co(II)(EBN)(H_2O)$], and [$Co(II)(PBN)(H_2O)$] have been synthesized. The mole ratio of Shiff base ligand to cobalt(II) for the Co(II) complexes was found to be 1:1. Also these complexes have been configurated with hexa-coordination. Reduction of dioxygen was investigated by cyclic voltammetry at glassy carbon electrodes modified with Schiff base Co(II) complexes in 1 M KOH aqueous solution. At modified glassy carbon electrode with Schiff base Co(II) complexes, reduction peak current of oxygen was increased and peak potential was shifted to more positive direction compared to bare glassy carbon electrode. The electrokinetic parameters such as number of electron and exchange rate constant were calculated from the results of cyclic voltammogrms. The reduction of dioxygen at glassy carbon electrode has been $2e^-$ reaction pathway. Exchange rate constant at glassy carbon electrode modified with Co(II) complexes was increased 2~10 times compared to bare electrode.

  • PDF

Study on the Surface Reactions of Graphite Electrodes by Anodic Polarization (양극분극에 의한 흑연전극의 계면반응에 대한 연구)

  • 오한준;김인기;이종호;이영훈
    • Journal of the Korean Chemical Society
    • /
    • v.41 no.1
    • /
    • pp.1-11
    • /
    • 1997
  • Electrode surface reaction on three carbon materials(glassy carbon, synthesized graphite, graphite foil) in 0.5 M K2SO4 electrolyte is investigated by impedance spectroscopy during anodic polarization. The double layer capacitance of the graphite foil electrode is relatively higher than that of other two materials. The change of capacitance parameter C due to chemical adsorption on glassy carbon and synthesized graphite(PVDF graphite) is observed in 0.5 M K2SO4 solution at anodic polarization. In general, the faradic impedance on glassy carbon depends on anodic polarization, and the change of impedance parameter on graphite foil at anodic polarization is not remarkable, because this reaction is controlled by field transport.

  • PDF