• Title/Summary/Keyword: Generator protection

Search Result 271, Processing Time 0.032 seconds

A comparison of speed control of various turbines according to power plant types (발전방식별 여러 가지 터빈의 속도제어 비교)

  • Choi, I.K.;Jeong, C.K.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2314-2316
    • /
    • 2001
  • The steam gererator which produces thermal energy from coal or gas is a very important device in power plants, including the turbine driving synchronous generator which transforms kinetic energy into electrical energy. The turbine and the generator are driven by many kinds of media according to the types of which power plants are classified into steam turbine generator, gas turbine generator, water turbine generator and so on. This paper introduces the overspeed protection as well as the various speed and load control methods of some types of turbines.

  • PDF

Application of Directional Over Current Protection Schemes Considering the Fault Characteristics in the Distribution System with Dispersed Generation (분산전원이 연계된 배전계통의 고장특성을 고려한 방향성 보호계전 방식 적용 연구)

  • Jung, Won-Wook;Lee, Hak-Ju;Kwon, Seong-Chul;Chae, Woo-Kyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.9
    • /
    • pp.97-107
    • /
    • 2010
  • Penetration of distributed generator(DG) to power distribution system can cause malfunction of existing protection schemes. Because grid interconnected DG can contribute fault currents and make bidirectional current flows on the system, fault contributions from DG can cause an interference of protection relay operation. Therefore, over current protection device of the distribution system with DGs need directional protection schemes. In this paper, improved directional protection algorithms are proposed for the distribution system with DG considering their fault characteristics. And than, these directional protection algorithms are tested and validated in various fault conditions. From the simulation results, it can be seen that the proposed directional protection algorithms are practically efficient for the radial distribution system with DG.

Realization of Torsional Response based on Multi-mass Modeling of Turbine-Generator Shaft System (터빈 발전기 축 시스템의 다중 질량체 모델링을 통한 비틀림 응답 구현)

  • Park, Ji-Kyung;Cho, Gyu-Jung;Sohn, Seung-Hyun;Chung, Se-Jin;Kim, Chul-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.2
    • /
    • pp.201-207
    • /
    • 2015
  • Turbine-generator torsional response is caused by interaction between electrical transient air-gap torque and mechanical characteristics of turbine-generator shafts. If torsional shaft torque exceeds a certain threshold, the loss of fatigue life may occur and, in the end, it is possible to happen permanent shaft failure. Therefore, it is required to understand the torsional response for reliable operation and protection of turbine-generator shaft system. In this paper, we introduced multi-mass modeling method of turbine-generator shaft system using mechanical-electrical analogy and state-space equation to verify the transient torsional response based on ElectroMagnetic Transient Program (EMTP). These simple realization methods for turbine-generator shaft torsional response could be helpful to understand torsional interaction phenomena and develop the transient torque reduction countermeasures for turbine-generator shaft system.

Analysis on Air-Gap Magnetic Flux of Synchronous Generator According to Short-Circuit Types in Winding (권선단락 유형별 동기발전기의 공극자속 파형 분석)

  • Bae, Duck-Kweon;Kim, Dong-Hun;Park, Jung-Shin;Lee, Dong-Young;Lee, Sung-Ill
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.5
    • /
    • pp.929-935
    • /
    • 2009
  • As modem industrialized society progresses, the demand for electric power is increasing rapidly. The electric power system is getting amazingly bigger and complicated, which can easily induce serious troubles from the potential of large fault problems and/or system failure. The monitoring and diagnosis of the electric machine for the fault detection and protection has been important part in the electric power system. Most faults in the generator appear in the winding. This paper presents the air-gap magnetic flux characteristic of a small-scale 2-pole synchronous generator according to the faults in the field winding to protect the generator from the fault. The magnetic flux patterns in air-gap of a generator under various fault conditions as well as a normal state are simulated by using finite element method. These results are successfully applied to the detection and diagnosis of the short-circuit condition in rotor windings of a high capacitor generator.

Immunity of Electronic Equipments Against Potable High Voltage Generator (휴대형 고전압 발생기에 대한 전자기기의 내성)

  • Lee, Jong-Ig;Yeo, Junho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.10a
    • /
    • pp.61-62
    • /
    • 2017
  • In this study, we introduce some main functions and specifications of a recently commercialized potable compact high voltage generator. USB killer has been designed to test surge protection circuitry of electronic equipments using USB ports. USB killer transforms 5V DC power supplied by USB port into a sufficiently high voltage over 200V DC through oscillator, transformer, voltage multiplier, and rectifier. The power charged in a high-capacity condenser can be applied back into the electronic equipments as an electric shock to destroy them or test protection circuits. USB killer is a readily available item, and one can test a variety of electronic equipments. We introduce some test results known over the internet and those obtained from our tests.

  • PDF

Development of Digital controller for emergency power generating system Using Micro-Controller (마이크로컨트롤러를 이용한 비상발전계통의 제어장치 개발)

  • Jeong, Eull-Gi;Jeon, Hee-Jong;Shon, Jin-Geun;Na, Chae-Dong;Lee, Seong-Bum
    • Proceedings of the KIEE Conference
    • /
    • 2001.07e
    • /
    • pp.100-102
    • /
    • 2001
  • This paper resents digital controller of emergency power generator system. The controller offers an integrated alternative for Genset control, metering and remote monitoring. Proposed controller used 80c196kc one chip microprocessor for digital control, it measures parameters of generator and provides output signals to control starting and stopping of generator. Additionally protection and alarm functions are considered to system stability. As almost parts of controller are embedded by digital microprocessor and FPGA techniques, the controller has a more flexible feature and an improvement of precision. The developed system has a big merit economically and is suitable for any kW size generator.

  • PDF

Development of PSCAD Simulation Model for Doubly-fed Induction-type Wind Power Generation System (이중여자 유도형 풍력 발전기의 PSCAD 시뮬레이션 모델 개발)

  • Jeong, Byoung-Chang;Kim, Hee-Jung;Chung, Yong-Ho;Jeon, Young-Soo;Kwak, No-Hong;Song, Seung-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.261-264
    • /
    • 2006
  • In this paper, doubly-fed induction-type wind power generation system simulation model for grid connection is developed. The simulation model is based on PSCAD/EMTDC and consists of rotor-blade, blade controller, generator power converter and generator controller Blade controller controls the blade pitch angle for starting, peak power limiting and emergency condition. Generator controller controls the generator output power to maximize the system efficiency. Simulation results are shown for the variable wind speed conditions. The simulation model can be utilized for study of actual interaction between wind turbine and grid for reliable operation and protection of power system.

  • PDF

A Coordination Algorithm For The Protection Of Large Wind Farms (대단위 풍력발전단지를 위한 보호협조 알고리즘)

  • Kwon, Young-Jin;Kang, Sang-Hee;Ryu, Gi-Chan;Song, Hwang-Bin
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.527-528
    • /
    • 2006
  • This paper presents a coordination algorithm for the protection of large wind farm of which consists loop connection system that is able to disconnect fault section from wind farm. The proposed coordination algorithm can distinguish between inner and outer fault of wind farm. by using changing of ratio generator output current over loop branch current connected to each generator. A series of PSCAD/EMTDC simulation results have shown effectiveness of the proposed algorithm.

  • PDF

Influence of the Interconnected Wind farm on Protection for Distribution Networks (풍력발전단지의 계통연계 운전이 배전선 보호계전에 미치는 영향)

  • 장성일;김광호
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.3
    • /
    • pp.151-157
    • /
    • 2003
  • Wind farm interconnected with grid can supply the power into a power network not only the normal conditions, but also the fault conditions of distribution network. If the fault happened in the distribution power line with wind fm, the fault current level measured in a relaying point might be lower than that of distribution network without wind turbine generator due to the contribution of wind farm. Consequently, it may be difficult to detect the fault happened in the distribution network connected with wind generator This paper describes the effect of the interconnected wind turbine generators on protective relaying of distribution power lines and detection of the fault occurred in a power line network. Simulation results shows that the current level of fault happened in the power line with wind farm depends on the fault impedance, the fault location. the output of wind farm. and the load condition of distribution network.

Modified Differential Protection for Transformers in Wind Farms

  • George, Sujo P.;Ashok, S
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.78-88
    • /
    • 2018
  • The liberalization of electricity market and environmental concerns are the major driving forces for the development of Distributed Generation (DG). The mode of grid-connected wind power generation is becoming popular and has matured as a reliable DG technology. The voltage generated by the wind generator is stepped up to the higher voltage by the transformers before connecting to the grid. Operating algorithm of the differential relays for transformer protection used in the wind farms need to be modified to take care of the dynamic nature of fault current caused by the intermittent nature of the wind power. An algorithm for the differential relay is proposed in which dual slope characteristics are adjusted with varying fault level situation according to the wind generator in service as well as with the wind speed. A case study conducted for a typical wind farm shows that the proposed method avoids mal-operation of the differential relay in varying wind power conditions.