• Title/Summary/Keyword: Generator Sensitivity

Search Result 167, Processing Time 0.025 seconds

Reliability Evaluation for Interconnecting the Power Systems in North East Asia (동북아시아 연계계통의 신뢰도평가)

  • Choi, J.S.;Kwon, J.J.;Tran, T.T.;Yoon, J.Y.;Park, D.W.;Moon, S.I.;Cha, J.M.
    • Proceedings of the KIEE Conference
    • /
    • 2005.11b
    • /
    • pp.17-19
    • /
    • 2005
  • This paper illustrates the case studies of reliability evaluation for interconnecting power systems in the north east Asia by using the tie line constrained equivalent assisting generator model(TEAG), which has been already developed in the second project year. A reliability evaluation program, it is named, NEAREL. based on the TEAS model was made. The reliability evaluation results for the seven interconnection scenarios of the actual power systems of six countries in the north east Asia are introduced and compared. The reasonable capacity of the tie line for three countries interconnection senario is suggested from sensitivity analysis.

  • PDF

A Study on the Measurement of 3-D object, make use of grid fringe generator (피치가변격자를 이용한 자유곡선 형상측정에 관한 연구)

  • 박윤창;정경민;박경근;장석준
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.19-22
    • /
    • 2000
  • Noncontact measuring methodology of 3-dimensional profile using CCD camera are very attractive because of it's high measuring speed and its's high sensitivity. Especially, when projecting a grid pattern over the object the captured image have 3 dimensional information of the object. Projection moire extract 3-D information with another grid pattern in front of CCD camera. However phase measuring profilometry(PMP) obtain similar results without additional grid pattern. In this paper, new method for grid pattern generation system by polygonal mirror and Laser Diode. This system is applied the projection moire and the PMP.

  • PDF

A Study on the System Design for Measuring the Property of Broadband AC Magnetic Sensors (광대역 교류 자기센서 특성 시험장치 설계에 관한 연구)

  • Chung, Hyun-Ju;Yang, Chang-Seob;Jung, Woo-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.685-686
    • /
    • 2015
  • This paper describes design results of the measurement system to test the properties of broadband AC magnetic field sensors used in weapon system. This measurement system consists of 3-axis helmholtz coil, signal generator, signal amplifier, sensor data acquisition unit and measurement & analysis controller including the operating software. This system is able to measure various properties of AC magnetic field sensor such as sensitivity, linearity and dynamic response in the frequency of 1 Hz to 10 kHz. The performance of this system was verified by measuring and analyzing the property of a MAG 639, standard magnetic field sensor of bartington instruments, with this developed system.

  • PDF

A Study on the Reliability Evaluation for Interconnecting Power Systems in Northeast Asia (동북아 전력계통 연계를 위한 신뢰도 산정에 관한 연구)

  • Choi, Jae-Seok;Cha, Jun-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.7
    • /
    • pp.1129-1134
    • /
    • 2008
  • This paper proposes a reliability evaluation for interconnection planning using a tie line equivalent assisting generator model (TEAG) that considers the uncertainties of the interconnected transmission systems and the tie lines. Development of this model was triggered by the need to perform probabilistic reliability evaluations on the NEAREST (North East Asia Region Electric Systems Tied) interconnection. The TEAG is the basis for the newly developed interconnection systems reliability evaluation computer program, NEAREL. The model is capable of considering uncertainties associated with generators, tie lines, and the tied grids. Reliability evaluations for six interconnection scenarios involving the power systems of six countries in the Asian north eastern region were performed using NEAREL. Sensitivity analysis was used to determine reasonable tie line capacities for three interconnected country scenarios of the six countries. Test results and summarized comments of the scenarios are included in the paper.

An Algorithm for BITC Evaluation considering the Power Control Characteristics of FACTS Devices (FACTS기기의 유효전력 제어특성을 고려한 모선간 송전용량 평가 알고리즘)

  • Yoon, Yong-Beum;Choo, Jin-Boo
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.2
    • /
    • pp.113-118
    • /
    • 1999
  • In this, sensitivity based approach to estimate BITC(bilateral interchange transfer capacity) considering the real power flow control function of FACTS devices is presented. The real power flow setting of the FACTS devices is adjusted so that it transfers the power flow from the first violation point of transmission capacity to other transmission lines in the power system, thus allowing more power to be transferred from the specified generator bus to the specified load bus. The transfer between the two bus locations is increased from this new operating condition until a violation of transmission capacity limits occurs or until the setting of the FACTS devices can no longer be adjusted. The proposed algorithm is illustrated using examples of small and real life power system.

  • PDF

BAYESIAN HIERARCHICAL MODEL WITH SKEWED ELLIPTICAL DISTRIBUTION

  • Chung, Youn-Shik;Dipak K. Dey;Yang, Tae-Young;Jang, Jung-Hoon
    • Journal of the Korean Statistical Society
    • /
    • v.32 no.4
    • /
    • pp.425-448
    • /
    • 2003
  • Meta-analysis refers to quantitative methods for combining results from independent studies in order to draw overall conclusions. We consider hierarchical models including selection models under a skewed heavy tailed error distribution proposed originally by Chen et al. (1999) and Branco and Dey (2001). These rich classes of models combine the information of independent studies, allowing investigation of variability both between and within studies, and incorporate weight function. Here, the testing for the skewness parameter is discussed. The score test statistic for such a test can be shown to be expressed as the posterior expectations. Also, we consider the detail computational scheme under skewed normal and skewed Student-t distribution using MCMC method. Finally, we introduce one example from Johnson (1993)'s real data and apply our proposed methodology. We investigate sensitivity of our results under different skewed errors and under different prior distributions.

Development of On-line Dynamic Security Assessment System (온라인 동적 안전도평가 시스템의 개발)

  • Nam, H.K.;Song, S.G.;Shim, K.S.;Moon, C.J.
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.73-76
    • /
    • 2001
  • This paper presents a new systematic contingency selection, screening and ranking method for on-line transient security assessment. Transient stability of a particular generator is influenced most by fault near it. Fault at the transmission lines adjacent to the generators are selected as contingency. Two screening methods are developed using the sensitivity of modal synchronizing torque coefficient and computing an approximate critical clearing time(CCT) without time simulation. The first method, which considers only synchronizing power, may mislead in some cases since it does not consider the acceleration power. The approximate CCT method, which consider both the acceleration and deceleration power, worked well. Finally the Single Machine Equivalent(SIME) method is implemented using IPLAN of PSS/E for detailed stability analysis.

  • PDF

An Algorithm for Transfer Capability Evaluation in Power Systems with FACTS Device (FACTS적용계통에서의 송전용량 평가 알고리즘)

  • Yoon, Yong-Beum;Yoon, Jong-Su;Choo, Jin-Boo
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.880-883
    • /
    • 1998
  • In this paper, sensitivity based approach to estimate BITC(bilateral interchange transfer capacity) considering the real power flow control function of FACTS device is presented. The real power flow setting of the FACTS device is adjusted so that it transfer the power flow from the first violation point of transmission capacity to other transmission lines in the power system, thus allowing more power to be transferred from the specified generator bus to the specified load bus. The transfer between the two bus locations is increased from this new operating condition until a violation of transmission capacity limits occurs or until the setting of the FACTS device can no longer be adjusted. The proposed algorithm is illustrated using examples of small and real life power system.

  • PDF

A temperature and supply insensitive CMOS current reference using a square root circuit (제곱근 회로를 이용한 온도와 공급 전압에 둔감한 CMOS 정전류원)

  • 이철희;손영수;박홍준
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.34C no.12
    • /
    • pp.37-42
    • /
    • 1997
  • A new temperature and supply-insensitive CMOS current reference circuit was designed and tested. Te temperature insensuitivity was achieved by eliminating the mobility dependence term through the multiplication of two current components, one which is proportional to mobility and the other which is inversely proportional to mobility, by using a newly designed CMOS square root circuit. The CMOS sqare root circuit was derived from its bipolar counterpart by operating the MOS transistors in the subthreshold region. The supply insensitivity was achieved by using an internal voltage generator. Te test chip was designed ans sent out for fabrication by using a 2.mu.m double-poly double-metal n-well CMOS technology. When an external voltage source was used for the square root circuit, the maximum variation and the average temperature sensitivity were measured to be 3% and 21.4ppm/.deg.C, respectively, for the temperature range of -15~130.deg.C. The maximum current variation with supply voltage was measured to be 3% within the commerical supply voltage range of 4.5~5.5V at 30.deg. C.

  • PDF

A Differential Current-to-Time Interval Converter Using Current-Tunable Schmitt Triggers

  • Chung, Won-Sup
    • Journal of IKEEE
    • /
    • v.21 no.4
    • /
    • pp.375-380
    • /
    • 2017
  • A differential current-to-time interval converter is presented for current mode sensors. It consists of a ramp voltage generator, a current mode sensor, a reference current source, two current-tunable Schmitt triggers, a one-shot multivibrator, and two logic gates. The design principle is to apply a ramp voltage to each input of the two current-tunable Schmitt triggers whose threshold voltages are proportional to the drain current values of the current mode sensors. A proposed circuit converts a current change in the ISFET biosensor into its equivalent pulse width change. A prototype circuit built using TSMC 0.18 nm CMOS process exhibit a conversion sensitivity amounting to $726.9{\mu}s/pH$ over pH variation range of 2-12 and a linearity error less than ${\pm}0.05%$.