• Title/Summary/Keyword: Generator Characteristics

Search Result 1,635, Processing Time 0.029 seconds

Analysis of Magnetic Field of Superconducting Winding According to the Changed Damper Thickness and Material (댐퍼의 두께와 재질 변화에 따른 초전도 선재에 미치는 자장특성 분석)

  • Jeong, Jae-Sik;Lee, Sang-Ho;Hong, Jung-Pyo;Jo, Young-Sik
    • Progress in Superconductivity and Cryogenics
    • /
    • v.14 no.3
    • /
    • pp.5-8
    • /
    • 2012
  • Superconducting windings of synchronous machine have to be operated in below the critical temperature, critical current density and critical magnetic field. If one of these characteristics does not satisfied, then the quench occurred in superconducting winding. Especially the armature current dramatically increased as the superconducting generator is short-circuited at the rated load condition and magnetic field in field winding increased due to the armature current. Therefore, damper is required to reduce the magnetic field of field winding which increases reliability of the superconducting generator. Damper dimension can be decided by time constant[1-2]. In this paper the basic model is high-power and low-speed superconducting generator. Damper time constant was calculated from the changed damper thickness and material. Magnetic flux of field coil at the basic model and changed damper time constant model is analyzed.

Characteristics of Accelerated Aging in Generator Stator Windings (발전기 고정자 권선의 가속열화 특성)

  • Kim, Hee-Dong;Kong, Tae-Sik;Ju, Young-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.279-280
    • /
    • 2008
  • Accelerated aging tests were conducted under laboratory conditions on two generator stator bars. Electrical stress is applied in No. 1 model stator bar. Electrical and thermal stresses are applied in No. 2 model stator bar. As aging times increased from 0 to 4780h, diagnostic tests were performed on No. 1 and No. 2 model stator bars. Diagnostic tests included AC current, dissipation factor(tan$\delta$) and partial discharge magnitude. The ${\Delta}tan{\delta}$ and $\Deta$I of No. 1 and No. 2 model stator bars increased with increased in aging time.

  • PDF

A Fuel Cell Generation System of SEPIC-Flyback Converter using a Single Transformer (단일 변압기를 사용한 SEPIC-Flyback 컨버터의 연료전지 발전 시스템)

  • Kang, K.S.;Jang, S.J.;Lee, T.W.;Kim, S.S.;Won, C.Y.
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.357-359
    • /
    • 2005
  • In this paper, a new SEPIC-Flyback converter with a single transformer has been proposed, which is suitable for a fuel cell based power generation system. The proposed converter is superposition of sepic and flyback converter mode. It has outstanding high boosting output voltage, component utilization and high efficiency characteristics under the inherently severe low output voltage of the fuel cell generator. The proposed converter for a full cell generator is described and verified by simulation and experimental result that make used of the Polymer Electrolyte Membrane Fuel Cell(PEMFC) Generator.

  • PDF

The Impulse Output Characteristics using Cascading Method of Compact Transformer (소형트랜스의 Cascading 방식을 적용한 임펄스 출력특성)

  • Joung, Jong-Han;Kim, Whi-Young;Hong, Jung-Hwan;Park, Koo-Ryul;Kim, Hee-Je;Cho, Jung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1865-1867
    • /
    • 2000
  • The pulse power system has been widely used to many applications. such as E/P(Electrostatic Precipitator), DeNOx/DeSOx power system, ozon generator. etc. A pulse energy efficiency for load depend on the rising time, peak value, pulse duration, impedance matching. etc. The pulse generator generally required for short pulse duration, high peak value was forced to consider its size and economy. In this study, developing a compact pulse generator that applied for Cascading method to be made of two pulse transformer, we compared cascading voltage with no cascading one by applying the pulse energy to load.

  • PDF

Analysis of Electromagnetic Field Characteristics of 30 KVA Superconducting Generator Using 3D FEM Program (3차원 유한요소 프로그램을 이용한 30 KVA 초전도발전기의 전자장 특성 해석)

  • Lee, Jong-Hyuk;Shin, Pan-Seok;Lee, Jae-Kun;Park, Do-Young
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.250-253
    • /
    • 1998
  • This paper has proposed a method to analyze a 30 KVA superconducting generator using 3-dimensional FEM program. 3 kinds of 3D formulation methods are employed such as scalar potential in core region, reduced scalar potential in air region and T-${\omega}$ formulation in stator coil region. As results of the simulation, various parameters of the generator have been analyzed like air gap flux density, induced voltage, inductance, etc.

  • PDF

A Study on the Introduction Effect of Superconducting Generators (초전도발전기의 도입효과에 관한 연구)

  • 백승규;심기덕;권운식;손명환;이언용;권영길;박희주;김영춘;조창호
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.209-212
    • /
    • 2003
  • The superconducting generator and motor have many advantages over the conventional machines. The better characteristics originates from the higher magnetic field density by way of superconducting field coil which conducts the operating current with very large density. The major merits of the superconducting machines can be explained as the smaller size and weight as well as the higher efficiency. The compactness would be very useful for the applications such as ship propulsion motors and the higher efficiency is expected to play a good role in saving the electricity generation cost for the generators used in power plants. In spite of these advantages the main reason for the lazy commercialization is known as the expensiveness of the superconductors and the cryogenic systems. In this paper focusing on the superconducting generator, we will consider and estimate the economic effectiveness when the machines permeate into the actual AC generator market in Korea gradually.

  • PDF

Decrease of Burst Pressure used a Nozzle Closure and Ignition Characteristics for a Gas Generator (가스발생기용 노즐마개 파열압력 저감화에 따른 점화특성)

  • Cha, Hong-Seok;Oh, Seok-Jin;Park, Jae-Beom;Lee, Yeung-Jo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.217-220
    • /
    • 2010
  • This paper presents an achieving method of reducing maximum acceleration for the missile by decrease of burst pressure in a nozzle closure. The relation of notch shape and burst pressure for a nozzle closure is examined by experiment. In the point of maximum acceleration reduction for a missile, an improved nozzle closure effects well compared with that of a reference closure by ground burning test of a gas generator.

  • PDF

Current-controllable saw-tooth waveform generators using current-tunable Schmitt trigger (전류-제어 슈미트 트리거를 이용한 전류-제어 톱니파 발생기)

  • Chung, Won-Sup;Lee, Myung-Ho
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.7 s.361
    • /
    • pp.31-36
    • /
    • 2007
  • A saw-tooth waveform generator whose frequency can be controlled with a do bias current is proposed. The generator utilizes operational transconductance amplifiers (OTA's) as switching element. It features simple and wide sweep capability The circuit built with commercially avaliable components exhibits good linearity of current-to-frequency transfer characteristics and relatively low temperature sensitivity.

Load Calculation of a 750 kW Direct-drive Wind Turbine Generator System (750kW급 직접구동형 풍력발전기의 부하계산)

  • Sohn, Y.U.;Park, I.S.;Kwon, S.J.;Kim, Y.C.;Son, J.B.;Kim, K.R.;Chung, C.W.;Chun, J.H.;Ryu, J.Y.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.649-655
    • /
    • 2003
  • Load calculation is indispensable for the construction of a large wind turbine generator system (WTGS). In procedures of load calculation, all conditions affecting to WTGS such as environment of site, operation, transport and installation have to be considered systematically. So the certification of WTGS is issued by assuring the load calculation. This work shows the generals of load calculation briefly and introduces the characteristics and results of load calculations for the 750 kW direct-drive WTGS (KBP-750D) which is under development by the consortium of POSTECH and UNISON.

  • PDF

Thyristor-Based Resonant Current Controlled Switched Reluctance Generator for Distributed Generation

  • Emadi Ali;Patel Yogesh P.;Fahimi Babak
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.1
    • /
    • pp.68-80
    • /
    • 2007
  • This paper covers switched reluctance generator (SRG) and its comparison with induction and synchronous machines for distributed generation. The SRG is simple in design, robust in construction, and fault tolerant in operation; it can also withstand very high temperatures. However, the performance and cost of the SRG power electronics driver are highly affected by the topology and design of the converter. IGBT and MOSFET based converters are not suitable for very high power applications. This paper presents thyristor-based resonant converters which are superior candidates for very high power applications. Operations of the converters are analyzed and their characteristics and dynamics are determined in terms of the system parameters. The resonant converters are capable of handling high currents and voltages; these converters are highly efficient and reliable as well. Therefore, they are suitable for high power applications in the range of 1MW or larger for distributed generation.