• Title/Summary/Keyword: Generation X

Search Result 981, Processing Time 0.027 seconds

A Study on the Optimal Make of X-ray Ionizer using the Monte Carlo N-Particle Extended Code(II) (Monte Carlo N-Particle Extended Code를 이용한 연 X선 정전기제거장치의 최적제작에 관한 연구(II))

  • Jeong, Phil Hoon;Lee, Dong Hoon
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.6
    • /
    • pp.29-33
    • /
    • 2017
  • In order to solve this sort of electrostatic failure in Display and Semiconductor process, Soft X-ray ionizer is mainly used. Soft X-ray Ionizer does not only generate electrical noise and minute particle but also is efficient to remove electrostatic as it has a wide range of ionization. There exist variable factors such as type of tungsten thickness deposited on target, Anode voltage etc., and it takes a lot of time and financial resource to find optimal performance by manufacturing with actual X-ray tube source. Here, MCNPX (Monte Carlo N-Particle Extended) is used for simulation to solve this kind of problem, and optimum efficiency of X-ray generation is anticipated. In this study, X-ray generation efficiency was compared according to target material thickness using MCNPX and actual X-ray tube source under the conditions that tube voltage is 5 keV, 10 keV, 15 keV and the target Material is Tungsten(W). At the result, In Tube voltage 5 keV and distance 100 mm, optimal target thickness is $0.05{\mu}m$ and fastest decay time appears + decay time 0.28 sec. - deacy time 0.30 sec. In Tube voltage 10keV and distance 100 mm, optimal target Thickness is $0.16{\mu}m$ and fastest decay time appears + decay time 0.13 sec. - deacy time 0.12 sec. In the tube voltage 15 keV and distance 100 mm, optimal target Thickness is $0.28{\mu}m$ and fastest decay time appears + decay time 0.04 sec. - deacy time 0.05 sec.

Study on Next Generation V2X System and Its Transmission Range (차세대 V2X 시스템과 그 전송 거리 분석)

  • Ahn, Jinsoo;Kim, Baik;Kim, Ronny Yongho
    • Journal of Advanced Navigation Technology
    • /
    • v.23 no.1
    • /
    • pp.36-43
    • /
    • 2019
  • In this paper, a novel channel access scheme for the next-generation vehicle to anything (V2X) system based on IEEE 802.11p standard which is applied to recent connected car technologies is suggested and analyzed. The proposed scheme proposes a channel access method utilizing OFDMA multi-user transmission for IEEE 802.11p based system. In this paper, the authors examine geographical distance and network area performance of IEEE 802.11p system and the proposed scheme. Results of this research show that the proposed scheme is quite suitable for improving conventional V2X standards and systems. This paper also provides mathematical analysis and simulation results of the conventional IEEE 802.11p system and the proposed scheme.

A Study on the Reduction of $NO_x$ Emission from Dual Fuel Engine for Co-generation System (열병합발적용 Dual Fuel Engine의 질소산화물 배출저감에 관한 연구)

  • 정일래;김용술;심용식
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.7 no.1
    • /
    • pp.31-40
    • /
    • 1991
  • This study shows the correlation between $NO_x$ emission in the exhaust gas and various operation factors of dual fuel engine for Co-generation system. General tendency was shown that the thermal efficiency was lowered by the change of operation factors. However these were not confirmed on this experiment. Increasing T4 temperature (exhaust gas temperature at turbo-charger inlet) reduces $NO_x$ emission rate. The higher T4 temperature requires lower excess air as the excess air ratio is controlled by T4 temperature on gas mode operation. Another tendency was that $NO_x$ emission rate is reduced in case of increasing boost air temperature, quantity of pilot oil or bypassing flue gas through the exhaust gas boiler. The diameter of the fuel injection nozzle was changed smaller than design value and the injection timing was readjusted. Thus $NO_x$ emission rate could be reduced as retarding injection timing and changing hole diameter of fuel injection nozzle, however maxium engine out-put was decreased by changing fuel nozzle on the diesel mode operation.

  • PDF

Generation of soft X-ray using laser-induced plasma (레이저 플라즈마를 이용한 soft X-선 발생)

  • Kim, G.H.;Seo, G.S.;Lee, H.S.;Rim, G.H.;Jin, Y.S.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2095-2097
    • /
    • 2000
  • Applications of soft X-ray which corresponds to the wavelength of the order of 1 nm and to the photon energy of the order of 1 key respectively, requires intense sources. Only synchrotron sources were available recently. The development of a new laboratory-sized source of soft X-ray radiation is required for wide applications. This paper introduces the generation of soft X-ray using laser-induced plasma.

  • PDF

Circularly polarized soft X-ray generation by Co/Pt thin film polarizer with perpendicular magnetic anisotropy

  • Lee, Sang-Hyuk;Huang, Lin;Lee, Jae-Woong;Kim, Namdong;Shin, Hyun-Joon;Jeong, Jong-Ryul;Hwang, Chanyong;Kim, Dong-Hyun
    • Current Applied Physics
    • /
    • v.18 no.11
    • /
    • pp.1196-1200
    • /
    • 2018
  • We have experimentally demonstrated circular polarization generation from linear polarized soft X-ray at synchrotron by adopting a thin magnetic film polarizer. Polarizer is composed of Co/Pt multilayer with a perpendicular magnetic anisotropy, which allows us to easily accommodate without needing any tilting angle into the measurement setup since the circular polarization is generated for the X-ray with normal incidence and transmission. Generated circular polarization is examined by observing magnetic domain features based on the X-ray magnetic circular dichroism, where~11% of circular component is estimated compared to the case of full circular polarization.

Emission Characteristics of Blue Fluorescence Tandem OLED Using MoOx (MoOx를 사용한 청색 형광 Tandem OLED의 발광 특성)

  • Kwak, Tea-Ho;Ju, Sung-Hoo
    • Journal of the Korean institute of surface engineering
    • /
    • v.47 no.3
    • /
    • pp.104-108
    • /
    • 2014
  • To improve emission efficiency of organic light emitting devices (OLEDs), we fabricated the tandem OLED of ITO / 2-TNATA / NPB / SH-1: 3 vol.% BD-2 / Bphen / Liq / Al / $MoO_x$ (X nm) / 2-TNATA / NPB / SH-1: 3 vol.% BD-2 / Bphen / Liq / Al structure. And emission properties of single OLED and tandem OLED with $MoO_x$ thickness as charge generation layer (CGL) were measured. The current emission efficiency and quantum efficiency of tandem OLED with $MoO_x$ of 3 nm thickness were improved compare with single OLED from 7.46 cd/A and 5.39% to 22.57 cd/A and 11.76%, respectively. In case of thicker or thinner than $MoO_x$ of 3~5 nm, the current emission efficiency and quantum efficiency were decreased, because balance of electron and hole in emission layer was not matching. The driving voltage was increased from 8 V of single OLED to 15 V of tandem OLED by thickness increase of OLED. As a result, it was possible to improve the emission efficiency of OLEDs by optimized $MoO_x$ thickness.

High-resolution Spectroscopy of the Nickel-like Molybdenum X-ray Laser Toward the Generation of Circularly Polarized X-ray Laser

  • Hasegawa, Noboru;Sasaki, Akira;Yamatani, Hiroshi;Kishimoto, Maki;Tanaka, Momoko;Ochi, Yoshihiro;Nishikino, Masaharu;Kunieda, Yuichi;Kawachi, Tetsuya;Yoneda, Hitoki;Iwamae, Atsushi
    • Journal of the Optical Society of Korea
    • /
    • v.13 no.1
    • /
    • pp.60-64
    • /
    • 2009
  • We attempted the first measurement of the spectral width of the nickel-like molybdenum x-ray laser (${\lambda}\;=\;18.895\;nm$) by use of a high-resolution spectrometer in order to determine the strength of the magnetic field required for the generation of a circularly polarized x-ray laser. The spectral width was measured to be ${\Delta}{\lambda}\;=\;18\;m{\AA}$ under the substantial lasing condition. The magnetic field required for the generation of a circularly polarized x-ray laser was 40 T. The splitting of the x-ray laser line was clearly obtained under 15 T external magnetic field. The strength of the magnetic field estimated from the splitting of the x-ray laser line was large compared with the external magnetic field. It implies that there might be an alternative mechanism for enhancement of the magnetic field in the gain medium plasma.

Effects of Generation on Professional Pride and Organizational Commitment among Hospital Nurses: The Mediating Effects of Individualism-Collectivism Tendency (병원간호사의 세대 간 전문직 자부심과 조직몰입: 개인주의-집단주의 성향의 매개효과를 중심으로)

  • Jo, Gyeong Won; Kim, Eun Joo
    • Journal of muscle and joint health
    • /
    • v.30 no.1
    • /
    • pp.15-24
    • /
    • 2023
  • Purpose: This study examined the mediating effect of the individualism-collectivism tendency of hospital nurses on the impact of their generation on professional pride and organizational commitment. Methods: 163 nurses participated in the study. One-way analysis of variance (ANOVA) and SPSS' Process Macro Model 4 was used to examine the relationships. Results: No intergenerational differences in individualistic propensity were observed, while collectivist propensity was higher in X-generation than Z-generation. Further, X-generation showed higher professional pride and organizational commitment than Y- and Z-generation. Notably, collectivistic (individualistic) tendency had (did not have) a mediating effect on the influence of generation on professional pride and organizational commitment. Conclusion: This study provided empirical evidence on the antecedent factors for forming collectivistic organizational culture in nursing organizations by demonstrating the mediating effect of collectivism propensity on professional pride and organizational commitment according to hospital nurses' generations nurses.

Analysis of a Spun-CNT Based X-ray Source

  • Kim, Hyun Suk;Castro, Edward Joseph D.;Hun, Choong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.639-639
    • /
    • 2013
  • In this research we report the significant contribution of the as-spun multi-walled carbon nanotube (MWCNT) on the x-ray images formation using a low tube voltage x-ray source. The MWCNT, which was used for the fabrication of the spun CNT, was grown using a microwave plasma-enhanced chemical vapor deposition machine. Electrical-optics simulation software was utilized to determine the electron field emission trajectory of the triode-structure-as-spun CNT-based x-ray source. It was shown that a significant amount of converging electrons hit the target anode producing a clear x-ray image. These x-ray images where produced at a small amount of anode current of 0.67 mA at a tube voltage of 5 kV with the gate voltage of 0 V. Also, comparisons of the radiographs at various exposure times of the sample where analyzed with and without an x-ray dose filter. Results showed that spatially-resolved images were formed using the as-spun CNT at a low tube voltage with a $54-{\mu}m$ Al x-ray filter. This study can be used for low-voltage medical applications.

  • PDF