• Title/Summary/Keyword: Generation Comparison

Search Result 1,287, Processing Time 0.024 seconds

Comparison of Performance of Flexible Solar Cells construction applied to Curtain Walls (커튼 월에 적용하는 플랙시블 태양전지의 모양에 따른 성능 비교)

  • Kim, Jaejin
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.14 no.4
    • /
    • pp.163-168
    • /
    • 2018
  • In this paper presents comparison of performance of flexible solar cells construction applied to curtain walls. The proposed paper compares power generation for curtain walls of various shapes using flexible PV. Through the comparison of performance, the power generation was compared by installing various types of flexible PV on the air layer of double windows. By comparing the measured power generation, it is possible to find an optimal flexible PV shape that can be applied to a curtain wall. Flexible PV installation was divided into diagonal, S and W shapes. As a result of comparison, the amount of power generation when there was no flexure of flexible PV was large. Also, as the angle with the light source increased, the power generation decreased. Therefore, it is necessary to study the structure which can fix the PV more than the flexible PV and to be able to direct the sun without distortion.

A Study on the Disciplinary Method in Korean Family: Comparing the cases of two generations between parents and children (부모세대가 받은 훈육방법과 그들의 자녀 훈육방법과의 비교 -서울시 일부 지역을 중심으로-)

  • 김희숙
    • Journal of the Korean Home Economics Association
    • /
    • v.26 no.3
    • /
    • pp.225-241
    • /
    • 1988
  • The purpose of this study is to find the difference between the parents generation and that of the children in the disciplinary methods by means of parental social population variation. With these purpose in mind, the problems have been suggested like following: 1) what are the general differences of between the two generations of parents and children in disciplinary method? 2)What are the general differences of the views between those two generations according to sex? 3) What are the general differences between the parents generation and the child generation according to age? 4) What are the general differences between the parents generation and the child generation according to education level? 5) What are the general differences between the parents generation and the child generation according to income level? In order to solve these problems, questionnaries were distributed on this appendix 374parents (father: 177, mother: 197) who have the children. Questionnaires were compose on "Parents Inventory" of Radke were employs, classfied five measures. To test and verifying the above hypothes, the following five measures. were used. 1) Philosophy of authority (authoritarian vs. democratic) 2) Parental restrition (strict and stubbon vs. democratic) 3) Severity of punishment (severity vs. mildness) 4) Parent-child rapport 9desirable vs. undesirable) 5) Relative responsibility of father and mothehr towards child disciplinary (equal vs. differ) The result of this study is like follows: 1) In general comparison of two generations, tends to be more democratic in the philosophy of authority, more relaxed and easygoing in the parental restroction, more severe in the severity of punishment, and good rapport in the parent-child rapport than grandparents generation and the responsibility of father don't change but that of mother tends to augment in child disciplinary 2) In comparison of two generation according to sex, the mother showed more democratic in the philosophy of authority and closely perceive her parents in the parent-child rapport as compared with the father. 3) In comparison of two generation according to age, the younger parents showed more relaxed attitudes towards the child disciplinary, the perception better relations of their parents in the parent-child rapport. 4) In the comparison of two generations according to education level the more educated parents showed the more relaxed and easygoing attitude towards in the parental restriction. 5) In comparison of two generation according to income, as the parents of large income generally (not always) showed easygoing than their previous generation in the parental restriction, and they perceive that they have a good one in parent-child rapport. This study caused by the some difficult problem required futher investigation on the result of two generations the problems happened in the inner unitary of items. And, it proposed some problems which constitutes the problems of the proper interpretation of the results between two generations brought about discordance of items between tow generations

  • PDF

A Comparative Study on the LCA Cases for Power Generation Technologies (발전기술의 LCA 수행사례 비교 연구)

  • Ji, Chul-Goo;Chung, Whan-Sam
    • Journal of the Korea Safety Management & Science
    • /
    • v.8 no.4
    • /
    • pp.249-265
    • /
    • 2006
  • A life cycle assessment(LCA) is increasing its applicability as a powerful tool for an environmental burdens analysis. In this study, some cases are compared in terms of analysis procedures and results obtained with LCAs for evaluating power generation technologies in Korea. For the comparison, 3 power generation technologies are selected because they produces almost 90% of 2003 total electricity generation in Korea. It is shown that the range of evaluation values amounts to maximally the order of about 105, which is rather large discrepancy than the level of 101 in comparison with foreign studies. The difference seems to be due to the simplicity of modeling used in each case study. It is proposed that this large discrepancy should be obviously clarified to improve their reliability in that electricity is a essentialness for all industries and the capacity of LCA of national-level electricity affects the results of LCA for the other sectors.

Performance Comparison According to Image Generation Method in NIDS (Network Intrusion Detection System) using CNN

  • Sang Hyun, Kim
    • International journal of advanced smart convergence
    • /
    • v.12 no.2
    • /
    • pp.67-75
    • /
    • 2023
  • Recently, many studies have been conducted on ways to utilize AI technology in NIDS (Network Intrusion Detection System). In particular, CNN-based NIDS generally shows excellent performance. CNN is basically a method of using correlation between pixels existing in an image. Therefore, the method of generating an image is very important in CNN. In this paper, the performance comparison of CNN-based NIDS according to the image generation method was performed. The image generation methods used in the experiment are a direct conversion method and a one-hot encoding based method. As a result of the experiment, the performance of NIDS was different depending on the image generation method. In particular, it was confirmed that the method combining the direct conversion method and the one-hot encoding based method proposed in this paper showed the best performance.

A Novel Simulation Scheme for Grid Connected Photovoltaic Generation Systems

  • Park, Monwon;Kim, Bong-Tae;Yu, In-Keun
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.11B no.4
    • /
    • pp.169-174
    • /
    • 2001
  • A novel simulation scheme of transient phenomenon for the photovoltaic (PV) generation system under the real weather conditions has been proposed in this paper. A grid connected PV array is simulated using PSCAD/EMTDC. The transient changes of the output current of PV array under the real weather conditions is described and the output current of DC/AC converter flowing through the utility power network is also analyzed with the PWM switching width. Moreover, the MPPT control of PV generation system is combined to the system during the simulation for the comparison purposes of the control schemes. The outcome of the simulation demonstrates the effectiveness of the proposed simulation scheme. The result shows that the cost effective verifying for the efficiency or availability and stability of PV generation systems and the comparison research of various control schemes like MPPT under the same real whether conditions are eventually possible.

  • PDF

The comparison of tidal power generation methods at Sukmodo (강화도 석모도 지역에서의 효율적인 조력발전방식 비교)

  • Lee, Tae-Hoon;Sim, Ju-Yeol;Cho, Yong-Sik
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.435-438
    • /
    • 2008
  • The huge economical damage and environmental pollution have been occurred for decades because of using of fossil fuel. So the development of alternative energy is urgent. In the west sea of Korea, a proper area for tidal power plant, development and investigation for economical efficient of tidal power plant are preceeding. The water turbine generator with the capacity of 25.4MW was used to compare single-basin flood tide generation with ebb tide generation while considering the water depth and tide in the vicinity of Sukmodo.

  • PDF

Generating Pairwise Comparison Set for Crowed Sourcing based Deep Learning (크라우드 소싱 기반 딥러닝 선호 학습을 위한 쌍체 비교 셋 생성)

  • Yoo, Kihyun;Lee, Donggi;Lee, Chang Woo;Nam, Kwang Woo
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.27 no.5
    • /
    • pp.1-11
    • /
    • 2022
  • With the development of deep learning technology, various research and development are underway to estimate preference rankings through learning, and it is used in various fields such as web search, gene classification, recommendation system, and image search. Approximation algorithms are used to estimate deep learning-based preference ranking, which builds more than k comparison sets on all comparison targets to ensure proper accuracy, and how to build comparison sets affects learning. In this paper, we propose a k-disjoint comparison set generation algorithm and a k-chain comparison set generation algorithm, a novel algorithm for generating paired comparison sets for crowd-sourcing-based deep learning affinity measurements. In particular, the experiment confirmed that the k-chaining algorithm, like the conventional circular generation algorithm, also has a random nature that can support stable preference evaluation while ensuring connectivity between data.

DEM Generation from Kompsat-2 Images and Accuracy Comparison by Using Common Software (Kompsat-2 영상의 DEM 생성 및 상용 소프트웨어와의 성능평가)

  • Rhee, Soo-Ahm;Jeong, Jae-Hoon;Kim, Tae-Jung
    • Korean Journal of Remote Sensing
    • /
    • v.25 no.4
    • /
    • pp.359-366
    • /
    • 2009
  • Research of accurate DEM generation using images of Kompsat-2 is not enough. This paper focused on generation of accurate Kompsat-2 DEM and comparison with DEM from common software like PCI Geomatica and ENVI. For Kompsat-2 DEM generation, we applied orbit-attitude sensor modeling technique and matching method based on epipolarity and image geometry. The comparison of performance with each commercial programs made a qualitative experiment through naked eyes and a quantitative experiment with USGS DTED. The accuracy was judged by the average absolute error and RMS error with DIED. The result of comparison experiment, we could confirm that the method used in the experiment showed much better performance than DEM made from other commercial programs in most of images.

Comparison of Measured and Predicted Photovoltaic Electricity Generation and Input Options of Various Softwares (태양광 발전량 예측 도구별 입력 요소 분석 및 실제 발전량 비교에 관한 연구)

  • No, Sang-Tae
    • KIEAE Journal
    • /
    • v.14 no.6
    • /
    • pp.87-92
    • /
    • 2014
  • The objectives of this study are to investigate input variables of photovoltaic generation programs and to compare their prediction to actual generation of photovoltaic system in the C city hall and the C city sewage treatment plant. We investigated the actual amount of generation, the forecast amount of generation, the amount of solar radiation data, and calculated the relative errors. We simulated the photovoltaic system of C city hall and the C city sewage treatment plant located in Chungju using existing programs, such as SAM, RETSCREEN, HOMER, PV SYST, Solar Pro. The result of this study are as follows : Through examining the relative errors of monthly predicted and actual generation data, monthly generation data showed big errors in winter season?. Except winter season, actual amount of generation and the predicted amount of generation showed no large errors.

Experiment and Electro-Thermo-Chemical Modeling on Rapid Resistive Discharge of Large-Capacity Lithium Ion Battery

  • Doh, Chil-Hoon;Ha, Yoon-Cheol;Eom, Seung-Wook;Yu, Jihyun;Choe, Seon-Hwa;Kim, Seog-Whan;Choi, Jae-Won
    • Journal of Electrochemical Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.323-338
    • /
    • 2022
  • Heat generation and temperature of a battery is usually presented by an equation of current. This means that we need to adopt time domain calculation to obtain thermal characteristics of the battery. To avoid the complicated calculations using time domain, 'state of charge (SOC)' can be used as an independent variable. A SOC based calculation method is elucidated through the comparison between the calculated results and experimental results together. Experiments are carried for rapid resistive discharge of a large-capacitive lithium secondary battery to evaluate variations of cell potential, current and temperature. Calculations are performed based on open-circuit cell potential (SOC,T), internal resistance (SOC,T) and entropy (SOC) with specific heat capacity.