• Title/Summary/Keyword: Generating Test Case

Search Result 77, Processing Time 0.027 seconds

An Experimental Study on Hydration Heat Characteristics for Thermal Crack Analysis Based on FEM of Urea Mixed Mass Concrete (Urea 혼입 매스콘크리트의 FEM 온도균열 해석을 위한 수화발열특성에 관한 실험적 연구)

  • Mun, Dong-Hwan;Jang, Hyun-O;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.36-37
    • /
    • 2019
  • In domestic construction industry progress, construction and quality control of large structures are considered to be important as the superstructure and mass scale of structures. In the case of mass concrete, high hydration heat caused by cement hydration generates temperature stress by generating internal temperature difference with the concrete surface. These temperature stresses cause cracks to penetrate the concrete structure. A method of lowering the heat generation by incorporating Urea in order to reduce the concrete temperature crack has been proposed. In this study, the heat function coefficient for the FEM temperature crack analysis of the mass concrete containing the element was derived and the adiabatic temperature rise test was carried out according to the incorporation of the element. As a result of this experiment, the maximum temperature of 41 ± 1℃ was obtained irrespective of the amount of urea, and the maximum temperature decreased by 16.9℃ in concrete containing 40kg/㎥ of urea.

  • PDF

A Study on the Corrosion Rehavior and Mechanical Property by SSRTTest of Welding Part of RE36 Steel for Marine Structure (해양구조물 RE36강의 용접부 부식거동 및 SSRT법에 의한 기계적 특성에 관한 연구)

  • 김종성;김진경;김종호;이명훈;김영식;문경만
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.24 no.4
    • /
    • pp.460-469
    • /
    • 2000
  • A study on the corrosion behavior of RE36 steel for marine structure was investigated with parameters such as micro-Vickers hardness, corrosion potential and corrosion current density measurement of weld metal(WM), base metal (BM) and heat affected zone(HAZ), Al anode generating current and Al anode weight loss quantity in case of cathodic protection. And we carried out slow strain rate test(SSRT) in order to research mechanical properties such as stress at maximum load, percent strain, time to fracture and strain to failure ratio etc and to find out limiting cathodic polarization potential for hydrogen embrittlement with applied cathodic polarization potential. Hardness of HAZ part was the highest among those three parts and also galvanic corrosion susceptibility was the highest in HAZ part among those three parts due to the lowest corrosion potential than other parts. However corrosion current density was the highest in WM part among those three parts. And the optimum cathodic polarization potential showing the best mechanical properties obtained by SSRT method with applied constant cathodic potential was from - 770mV to - 875mV(SCE). However it is suggested that limiting cathodic polarization potential indicating hydrogen embrittlement on the mechanical properties was under - 900mV(SCE).

  • PDF

Delayed Analysis of Hydrogen-Methane Breath Samples

  • Willemsen, Marjolein;Van De Maele, Kristel;Vandenplas, Yvan
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.25 no.1
    • /
    • pp.13-20
    • /
    • 2022
  • Purpose: Hydrogen-methane breath tests are used to diagnose carbohydrate malabsorption and small intestinal bacterial overgrowth. The COVID-19 pandemic has driven the modification of procedures as breath tests are potentially aerosol-generating procedures. We assessed the effect of delayed analysis of breath samples, facilitating the at-home performance of breath testing. Methods: Children provided two breath samples at every step of the lactose breath test. The samples were brought back to the clinic, and one set of samples was analyzed immediately. The second set was stored at room temperature and analyzed 1-4 days later. Results: Out of the 73 "double" lactose breath tests performed at home, 33 (45.8%) were positive. The second samples were analyzed 20 to 117 hours after the first samples (41.7±24.3 hours). There was no significant difference in the hydrogen concentration between the first and second sets (Z=0.49, p=0.62). This was not the case for methane, which had a significantly higher concentration in the second breath samples (Z=7.6). Conclusion: Expired hydrogen levels remain stable in plastic syringes if preserved at room temperature for several days. On the other hand, the delayed analysis of methane appeared to be less reliable. Further research is needed to examine the impact of delayed analysis on methane and hydrogen concentrations.

An Algorithm Generating All the Playable Transcoding Paths using the QoS Transition Diagram for a Multimedia Presentation Requiring Different QoS between the Source and the Destination (근원지와 목적지에서 서로 다른 서비스 품질(QoS)을 필요로 하는 멀티미디어 연출의 재생을 위한 서비스 품질 전이도 기반의 변환 경로 생성 알고리즘)

  • 전성미;임영환
    • Journal of Korea Multimedia Society
    • /
    • v.6 no.2
    • /
    • pp.208-215
    • /
    • 2003
  • For playing a multimedia presentation in a Internet, the case that the presentation QoS(Quality of Services) at a destination nay be different from the QoS of multimedia data at the source occurs frequently. In this case, the process of trancoding the multimedia data at the source Into the multimedia data satisfying the QoS at the destination should be requited. In addition, even the presentation description having the homogeneous QoS at both sides may have different transcoding paths due to the limitation of display terminals or network bandwidth. That is, for a multimedia description, it is required to regenerate a proper transcoding path whenever the displaying terminals or the network environment gets decided. And the delay time required to go through the transcoding path may affect the playability of the give presentation. Therefore it should be checked whether the presentation requiring a transcoding process is able to be played in a real time. In this paper, the algorithm for generating all the possible transcoding paths for a given multimedia description under a fixed set of transcoders and the network environment is proposed. The algorithm adopts the concept of QoS transition diagram to Prevent from a trancoding Path being cycled by the repetition of a cyclic Path which generates the same QoS of multimedia data as its input QoS. By eliminating all the cyclic Paths, the algorithm can guarantee the termination of the process. And for the playability check, a method of computing the transcoding time and the delay lime between logical data units are proposed.Finally all the proposed methods were implemented in the stream engine, called TransCore and the presentation-authoring tool, called VIP, we had developed. And the test results with sample scenarios were presented at the last.

  • PDF

A Pre-Feasibility Test of Introducing Renewable Energy Hybrid Systems -Case Studies for 3 Off-Grid Islands- (도서지역 신·재생복합 전력시스템 보급 타당성 분석 -3개 도서지역 분석결과-)

  • Jang, HaNa;Kim, Suduk
    • Environmental and Resource Economics Review
    • /
    • v.15 no.4
    • /
    • pp.693-712
    • /
    • 2006
  • A pre-feasibility test is done for renewable energy hybrid power systems at off~grid islands in which the current power supply is provided only by diesel generation. We apply Homer (Hybrid Optimization Model for Electric Renewables) which was developed by the National Renewable Energy Laboratory (NREL) for the analysis to identify the cost-minimizing combination of power generating facilities for the given load profiles. Chuja-Do, Geomun-Do and Youngsan-Do have been selected for our analysis considering the wind resources data of the Korea Institute of Energy Research (KIER). Information on wind speed, solar radiation and temperature is also used for the analysis. System component cost information from overseas market has been used due to the lack of domestic information. Site specific Load profile for electricity demand for those islands are reconstructed based on the partial survey results obtained form other sources. The LCOE of the least cost hybrid power systems for Chuja-Do, Geomun-Do and Youngsan-Do are $0.278/kWh, $0.234/kWh and $0.353/kWh, respectively Considering the fact that diesel generation is being subsidized at the price of $0.300/kWh by the government, first 2 cases are economically feasible for the introduction of renewable energy hybrid systems to those islands. But the third case of Youngsan-Do does not meet the criteria. The basic differences of these pre-feasibility test results are from the differences of the site specific renewable energy conditions, especially wind resources. In summary, promoting hybrid systems in the off-grid remote island should be based on the economic feasibility test results. Not all the off-grid islands are feasible for introducing this renewable energy hybrid system.

  • PDF

RELATIONSHIPS OF THE SOLAR WIND PARAMETERS WITH THE MAGNETIC STORM MAGNITUDE AND THEIR ASSOCIATION WITH THE INTERPLANETARY SHOCK

  • OH SU YEON;YI YU
    • Journal of The Korean Astronomical Society
    • /
    • v.37 no.4
    • /
    • pp.151-157
    • /
    • 2004
  • It is investigated quantitative relations between the magnetic storm magnitude and the solar wind parameters such as the Interplanetary Magnetic Field (hereinafter, IMF) magnitude (B), the southward component of IMF (Bz), and the dynamic pressure during the main phase of the magnetic storm with focus on the role of the interplanetary shock (hereinafter, IPS) in order to build the space weather fore-casting model in the future capable to predict the occurrence of the magnetic storm and its magnitude quantitatively. Total 113 moderate and intense magnetic storms and 189 forward IPSs are selected for four years from 1998 to 2001. The results agree with the general consensus that solar wind parameter, especially, Bz component in the shocked gas region plays the most important role in generating storms (Tsurutani and Gonzales, 1997). However, we found that the correlations between the solar wind parameters and the magnetic storm magnitude are higher in case the storm happens after the IPS passing than in case the storm occurs without any IPS influence. The correlation coefficients of B and $BZ_(min)$ are specially over 0.8 while the magnetic storms are driven by IPSs. Even though recently a Dst prediction model based on the real time solar wind data (Temerin and Li, 2002) is made, our correlation test results would be supplementary in estimating the prediction error of such kind of model and in improving the model by using the different fitting parameters in cases associated with IPS or not associated with IPS rather than single fitting parameter in the current model.

A Transactor Implementation for SoC Verification with iPROVE (iPROVE 기반 SoC 검증을 위한 트랜잭터 구현)

  • Cho, Chong-Hyun;Cho, Joong-Hwee
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.4
    • /
    • pp.73-79
    • /
    • 2007
  • In this paper the proposed transactor is customized and a generator which roles of automatically generating the transactor according to DUT(Design Under Test)'s input and output is implemented. The customized transactor is designed by rearranging the signals of depending on DUT and transactor protocol which consists of signals of the PCI interface between host computer and FPGA(Field Programmable Gate Array). The implemented automatic generator of transactor generates a Verilog code of transactor by adding DUT's information about input and output ports. Performance and normal working of the generated transactor has been verified by experiments with some verified hardware IPs. Also, an efficiency of the transactor has been verified by comparing with user's manually designed transactor and generated transactor. Moreover, the generator's flexibility has been verified for DUT's information of variable input and output. In case of using the implemented generator, a design time of transactor is reduced.

The Studies of Stability for Volatile Organic Compounds(VOCs) Generated from the Adhesives (접착제에서 발생하는 휘발성유기화합물(VOCs)에 대한 안정성 연구)

  • Lee, Hyeon Kyeong;Wi, Koang Chul
    • Journal of Conservation Science
    • /
    • v.31 no.3
    • /
    • pp.243-254
    • /
    • 2015
  • In this study, the stability of the adhesive was determined through the Oddy Test that is Verification Test for potential damage by various materials. And to find the factor causing the corrosion of the metal samples, the adhesives and coatings those are usually used in the metal preservation process were selected and treated on the samples. Six kinds of adhesives and four kinds of metal specimens Fe, Pb, Cu, Ag were used. As results, the weight change showed high increasement in the rate of weight change 29.87% of Fe sample. The chromaticity measurement showed the high change value of the Cellulose-based adhesive. In case of the VOCs test from adhesive by using GC-MS, Acetic acid was detected from all six kinds of the adhesives. Compared to cellulose-based adhesives and the other adhesives, the amount of VOCs per 1mg concentration is higher than 900 times and was detected small amount of Formic acid. This is assumed to be facilitated by acid impurities and the light. This reaction was considered as the result of reducing a large amount of molecular and of generating a large amount of Nox. And thus the reacted sulfur changes was considered as the factor for causing corrosion.

Environmental Characteristics of Leachates from Steel Slag (제강슬래그 침출수의 환경적 특성)

  • Park, Jong-Beom;Lee, Byoung-Chan;Jang, Min-Ho;Na, Hyun-Ho
    • Journal of the Korean Geosynthetics Society
    • /
    • v.11 no.2
    • /
    • pp.31-38
    • /
    • 2012
  • The recycled aggregate for construction, slag, coal ash and such may elute leachates by chemical reaction when in touch with water, and to confirm this, generally the waste process test is executed. If the test result criteria are met, it can be used as replacement aggregate. In case of steel slag, however, the chemical reaction does not end in a short term, but occurs over a long time, generating eluted leachate. Thus, in this study, the leachate from steel slag were analyzed for heavy metal, and the pH change and environmental characteristics of eluted leachate were analyzed. According to the experiment result, the chemical reaction of free CaO and water within the steel slag occurred more actively when stirred, and the smaller the grain size, the higher the pH was. As the result of waste process test, all test items for the two types of specimen were found to have no heavy metal, but from the ICP test analysis result, heavy metals such as Al, Pb, Zn, Fe were detected. It could be confirmed that chemical reaction would occur upon contact of steel slag and water, and heavy metal may be detected depending on experiment conditions and analysis methods, the long-term environmental characteristics should be examined for utilization of steel slag.

Comparison of Dose Depending on the Position when Shooting Panorama and CBCT (CBCT와 panorama 촬영시 위치에 따른 선량 비교)

  • Jeong, Cheonsoo;Kim, Chongyeal
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.3
    • /
    • pp.175-179
    • /
    • 2013
  • To find out the appropriate defensive measures for protectors and radiation workers in rotating radiation generating devices such as CBCT and panorama, irradiation dose depending on the position was compared and analyzed. The devices such as panorama DP-90-P PAX-500 (Vatech, Korea) and CBCT DCT-90-P IMPLAGRAPHY Dental CT system (Vatech, Korea) were used. As irradiation dose measuring instruments, Ion chamber model 2026 and Reader 20X5-60E were used. The exposure conditions were set as the factor used in the clinical trial. The result of the experiment showed that panorama was the highest, 81${\mu}R$, at point A where the test starts first and the lowest, 53${\mu}R$, at point D where the test ends. In case of CBCT, it was the highest, 1,021${\mu}R$, at point D where the test ends and was measured as the highest, 809.67${\mu}R$, at point A where the test starts. If protectors and radiation workers are forced to examine a patient holding him, they should be positioned in the middle of the point where X ray tube starts to rotate and the point where it ends to avoid the position where radiation dose is the most. And due to the nature of equipment, it will be the safest for them to stand at the opposite side of the machine and to uphold it from the rear rather than upholding it from the side of a patient and they should wear appropriate the protection gear.