건물 단지에 대한 에너지 수요 예측 데이터베이스 응용 프로그램 개발 (Development of a Energy Demand Estimator for Community Energy Systems)

  • 정모;박화춘
    • 한국태양에너지학회 논문집
    • /
    • 제29권3호
    • /
    • pp.37-44
    • /
    • 2009
  • The field-surveyed and measured energy consumption data is processed to develop building energy demand models for heating, hot water, cooling, and electricity. The load models are systematically organized as a database and hourly loads for a span of year (8760 hours) are generated by the program. Rased on those models a Microsoft Access application program is developed to calculate energy demands for a Community Energy System (CES) composed of 17 types of buildings. User-friendly interfaces are provided to assist non-expert end users and necessary tools to link the calculation results to subsequent coagulations such as operation simulation or economic assessment.

환경부하 저감을 위한 주택의 에너지절약 시스템에 관한 연구 -소형코제너레이션시스템과 태양광발전시스템을 적용한 성능평가- (A Study on The Energy Conservation System in House for reducing the Environmental Load)

  • 정진현
    • 한국주거학회논문집
    • /
    • 제11권1호
    • /
    • pp.159-169
    • /
    • 2000
  • This study was examined the energy conservation and the environmental value through the computer simulation employing the micro cogeneration system and the photovoltaic power generation system in house. The results of this study were as follows:1. In case of the micro cogeneration system. With the conditions of 'the electric produced by the micro cogeneration system was not sold to the electric power company', 'control quantity of commercial power supply was 10%' , 'operating time was 6 hour', 'minimum load rate of generator was 50%', and 'having a storage tank', the micro cogeneration system was superior compare to the comparative system in 2.4% of the energy conservation and 4.18% of the environmental value. 2. In case of the photovoltaic power generation system. 1) The 66.9% of total generated electric power from the photovoltaic power system was sold to the electric power company. That is, it could help to preserve the electric power from commercial power supply.2) There is a possibility of cutting the fair rate of electric power.

  • PDF

수도사업장 고조파 측정, 분석을 통한 관리기준 만족여부 조사 (To examine of management standard by the harmonics measured and analyzed in water supply field)

  • 홍성택;이은춘;신강욱;임재일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.296-298
    • /
    • 2003
  • At the water supply field, high voltage induction motor is main facility of a load equipment. The motor is often out of order and its noise, generated heat, loss etc occured occasionally. especially, transmission motor for flux control generates an amount of the harmonics then have a bad influence upon the electric power system. In this study, to analyze the total harmonics distortion of the water supply field receiving high voltage, the harmonics measured and analyzed using the PQA(Power Quality Analyzer) according to the electric power system and electrical load and the reduction method presented.

  • PDF

타여자직류기의 속도제어를 위한 강인 적응 백스테핑 제어기 설계 (Design of Robust Adaptive Backstepping Controller for Speed Control of Separately Excited DC Motor)

  • 현근호;손인환
    • 전기학회논문지P
    • /
    • 제54권2호
    • /
    • pp.80-88
    • /
    • 2005
  • In this paper, an robust adaptive backstepping controller is proposed for the speed control of separately excited DC motor with uncertainties and disturbances. Armature and field resistance, damping coefficient and load torque are considered as uncertainties and noise generated at applying load torque to motor is also considered. It shows that the backstepping algorithm can be used to solve the problems of nonlinear system very well and robust controller can be designed without the variation of adaptive law. Simulation and experiment results are provided to demonstrate the effectiveness of the proposed controller.

DVSC를 이용한 개선된 APF의 설계 (Design of Improved Active Power Filter using Discrete Variable Structure Control)

  • 박해원;김상우;한운동;김병진;전희종
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.1312-1314
    • /
    • 2000
  • In this paper, voltage control APF(Active Power Filter) is introduced to improve power factor and reduce harmonic, generated from nonlinear load. The voltage controlled APF which is consisted of inverter and passive filter operates with nonlinear load simultaneously. According to the results of simulation, it is proved that the proposed system has the performance of improving power factor and reducing harmonics.

  • PDF

퍼지 규칙 생성에 의한 교환 시스템의 과부하 상태 검출 (Overload Detection in Switching Systems using FUzzy Rrules)

  • 주성순;이정훈
    • 전자공학회논문지C
    • /
    • 제34C권6호
    • /
    • pp.79-88
    • /
    • 1997
  • New technologies, systems, and services in telecommunication have increased the need for an efficient and robust control mechanism to protect switching systems from overload. To achieve proper control, it is necessary to find a set of parameters that can describe the system. However, it is difficult to find types of data that can form a suitable basis for control. In this paper, we categorize the load status of a switching system into three classes (i.e., normal state, pre-overload state, and overload state) and formulate the overload detection as a classification problem. We find the relationships between the load classes and a set of monitored switching system parameters by applying a fuzzy rule-generation method. The rules are automatically generated from training data. Simulation results involving a switching system is given.

  • PDF

Crack growth life model for fatigue susceptible structural components in aging aircraft

  • Chou, Karen C.;Cox, Glenn C.;Lockwood, Allison M.
    • Structural Engineering and Mechanics
    • /
    • 제17권1호
    • /
    • pp.29-50
    • /
    • 2004
  • A total life model was developed to assess the service life of aging aircraft. The primary focus of this paper is the development of crack growth life projection using the response surface method. Crack growth life projection is a necessary component of the total life model. The study showed that the number of load cycles N needed for a crack to propagate to a specified size can be linearly related to the geometric parameter, material, and stress level of the component considered when all the variables are transformed to logarithmic values. By the Central Limit theorem, the ln N was approximated by Gaussian distribution. This Gaussian model compared well with the histograms of the number of load cycles generated from simulated crack growth curves. The outcome of this study will aid engineers in designing their crack growth experiments to develop the stochastic crack growth models for service life assessments.

주행 중 발생하는 고속전철 집전계 신호의 특성 (Characteristics of Current Collection Signals during Test Run of High-speed Train)

  • 이시우;김정수;조용현;최강윤
    • 한국철도학회논문집
    • /
    • 제7권3호
    • /
    • pp.232-238
    • /
    • 2004
  • The dynamic characteristics of the current collection process of the high-speed railway are investigated through signals acquired during a test run. The signals are obtained from accelerometers, load cells, and strain gauges attached to various positions of the pantograph, and they are processed in time-and frequency-domains to obtain the dynamic characteristics. The main natural frequency of the pantograph is found to be 8.5Hz. There also are components at low frequencies varying linearly with the train speed. The contact frequency components above 20Hz is attenuated as they pass through the secondary suspension. The main frequency component of the load cell signal is found to be related with the rolling motion of the panhead generated by the stagger in the catenary.

Acoustic Emission on Failure Analysis of Rubber-Modified Epoxy Resin

  • Lee Deok-Bo
    • Fibers and Polymers
    • /
    • 제5권4호
    • /
    • pp.259-263
    • /
    • 2004
  • Rubber-modified epoxy resins have been employed as adhesive and matrix materials for glass and corbon-fiber composites. The behavior of fracture around a crack tip for rubber-modified epoxy resin is investigated through the acoustic emission (AE) analysis of compact tension specimens. Damage zone and rubber particles distributed around a crack tip were observed by a polarized optical microscope and an atomic force microscope (AFM). The damage zone in front of pre-crack tip in rubber-modified specimen $(15wt\%\; rubber)$ began to form at about $13\%$ level of the fracture load and grew in size until $57\%$ load level. After that, the crack propagated in a stick-slip manner. Based on time-frequency analysis of AE signals and microscopic observation of damage zone, it was thought that AE signals with frequency bands of 0.15-0.20 MHz and 0.20­0.30 MHz were generated from cavitation in the damage zone and crack propagation, respectively.

고조파 저감과 입력역률 개선을 위한 전력용 능동필터의 설계 (The Design of Active Power Filter with the Performance of Harmonic Suppression and Input Power Factor Correction)

  • 박해원;최성관;김호;김병진;전희종
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 B
    • /
    • pp.375-377
    • /
    • 2000
  • In this paper, voltage controlled APF(Active Power Filter) is introduced to improve power factor and reduce harmonic generated from nonlinear load. The voltage controlled APF which is consisted of inverter and passive filter operates with nonlinear load simultaneously. According to the results of simulation, it is proved that the proposed system has the performance of improving power factor and reducing harmonics.

  • PDF