• Title/Summary/Keyword: General radiography

Search Result 189, Processing Time 0.031 seconds

General Radiography Usage and Exposure Dose of Korean Elderly: Based on Data from Aged Patients in 2016 (한국 노인의 일반촬영 이용량 및 피폭선량: 2016년 고령환자데이터 기반)

  • Gil, Jong-Won;Yoo, Se-Jong;Lee, Won-Jeong
    • Journal of radiological science and technology
    • /
    • v.44 no.5
    • /
    • pp.495-502
    • /
    • 2021
  • This study aims to provide basic data for elderly health insurance policy and medical radiation safety management by analyzing the general radiography usage and exposure dose of the elderly in Korea. The effective dose for each general radiography was calculated using the ALARA-GR program for 260 general radiography codes selected from 'National Health Insurance Care Benefit Cost'. The usage of general radiography was analyzed in the 2016 elderly patient data of the Health Insurance Review and Assessment Service, and the effective dose for each general radiography was applied. The general radiography usage and exposure dose per person aged 65 years and over was 6.47 cases and 0.56 mSv. Females showed higher value than males as 7.15 cases and 0.66 mSv(p<.001). By age, those between 75 and 79 showed the highest number as 6.97 cases and 0.62 mSv(p<.001). Those who were supported by Medical Aid showed higher value than those who were insured by National Health Insurance as 8.82 cases and 0.76 mSv(p<.001). In addition, the ratio by radiography was in the order of Chest 20.85%, Knee Joint 15.58%, and L-spine 14.67%, and the exposure dose was L-spine 29.40%, Chest 15.82%, Abdomen 7.97%, and Entire Spine 7.20%. General radiography, which is widely used due to the high frequency of diseases in the elderly population should be taken into consideration when establishing health insurance policies. In addition, it is necessary to check whether the general radiography with high exposure dose is performed as a routine examination without considering medical necessity.

National Data Analysis of General Radiography Projection Method in Medical Imaging (영상의학검사 일반촬영 분야의 촬영기법에 대한 분석)

  • Kim, Jung-Su;Kim, Jung-Min;Lee, Young-Han;Seo, Deok-Nam;Choi, In-Seok;Nam, So-Ra;Yoon, Yong-Su;Kim, Hyun-Ji;Min, Hye-Lim;Her, Jea;Han, Seong-Gyu
    • Journal of radiological science and technology
    • /
    • v.37 no.3
    • /
    • pp.169-175
    • /
    • 2014
  • According to database of medical institutions of health insurance review & assessment service in 2013, 1118 hospitals and clinics have department of radiology in Korea. And there are CT, fluoroscopic and general radiographic equipment in those hospitals. Above all, general radiographic equipment is the most commonly used in the radiology department. And most of the general radiographic equipment are changing the digital radiography system from the film-screen types of the radiography system nowadays. However, most of the digital radiography department are used the film-screen types of the radiography system. Therefore, in this study, we confirmed present conditions of technical items for general radiography used in hospital and research on general radiographic techniques in domestic medical institutions. We analyzed 26 radiography projection method including chest, skull, spine and pelvis which are generally used in the radiography department.

A Study on the Usefulness of Total Hip Replacement Arthroplasty Using Fluoroscopy (투시하에 시행한 고관절 확대계측 촬영술의 유용성에 관한 분석)

  • Lee, H.J.;Son, S.Y.;Um, J.Y.;Chin, J.H.;Kim, K.C.
    • Journal of radiological science and technology
    • /
    • v.22 no.1
    • /
    • pp.21-26
    • /
    • 1999
  • To make a comparative analysis for clinical application of total hip replacement arthroplasty(THRA) using fluoroscopy, we have performed total hip replacement arthroplasty making 30 patients an object with general radiography and fluoroscopy respectively. The results are as follows : 1) Reexamination rate was 80% of patients and mean 3.9 sheets in the general radiography, where as it was 46.7% and 0.37 sheets in the fluoroscopy(p<0.01) 2) Add examination was 2 cases in the general radiography, but fluoroscopy was no add examination. 3) The total film sheet used was mean 10.16 in the general radiography and 6.73 in the fluoroscopy. 4) In the cause of reexmination and add examination, inaccurate position of patient accounted for 72.6% in the general radiography and poor exposure condition accounted for 45.5% in the fluoroscopy. Total hip replacement arthroplasty using the fluoroscopy decreased reexamination and add examination rate, for these reasons, this method was effective abatement of pain, exposured radiation dose, and examination time and so on.

  • PDF

The Utility of Emergency Ultrasound for Diagnosing Wrist and Ankle Injuries (손목 관절과 발목 관절 손상 환자의 진단에 있어 응급 초음파의 유용성)

  • Lee, Sung Sil;Kim, Dong Un;Park, Deuk Hyun;Cho, Hyun Young;Ahn, Seung Jun;Kho, Chan Young;Shin, Tae Yong;Kim, Young Sik;Ha, Young Rock
    • Journal of Trauma and Injury
    • /
    • v.20 no.2
    • /
    • pp.130-137
    • /
    • 2007
  • Purpose: Ultrasound is of proven accuracy in abdominal and thoracic trauma and may be useful for diagnosing extremity injury in situations where radiography is not available, such as disasters and military and space applications. However, the diagnosis of fractures is suggested by history and physical examination and is typically confirmed with radiography. As a alternative to radiography, we prospectively evaluated the utility of extremity ultrasound performed by trained residents of emergency medicine (EM) one patient with wrist and ankle extremity injuries. Methods: Initially, residents of EM performed physical examinations for fractures. The emergency ultrasound (EM US) was performed by trained residents, who used a portable ultrasound device with a 10- to 5-MHz linear transducer, on suspected patients before radiography examination. The results of emergency ultrasound and radiography and the final diagnosis were recorded, and correlation among them were determined by using Kappa s test Results: Thirty-nine patients were enrolled in our study. The average age was $36.6\;{\pm}\;19.3$ years. There were radius Fx. (n=21), radius-ulna Fx. (n=1), ulna Fx. (n=1), and contusion (n=2) injuries among the wrist injury and lat.-med. malleolar Fx. (n=13), lat. malleolar Fx. (n=6), and med. malleolar Fx. (n=3) injuries among the ankle injury. Comparing EM US with radiography, we found the sensitivity, specificity, positive predictive value, and negative predictive value of EM US for Fx. diagnosis to be 100%, 66.7%, 97.3%, 100% and those of radiography to be 97.2%, 100%, 100%, and 75%, respectively. Kappa s test for a correlation between the Fx. diagnosis of EM US and the final diagnosis of Fx was performed, and Kappa's value was 0.787 (P = 0.004).Conclusion: EM US for Fx. can be performed quickly and accurately by EM residents with excellent accuracy in remote locations such as disaster areas and in military and aerospace applications. EM US was as useful as radiography in our study and had a high correlation to the final diagnosis of Fx. Therefore, ultrasound should performed on patients with extremity injury to determine whether extremity evaluation should be added to the FAST (focused abdominal sonography trauma) examination.

The Distribution and Patient Care in Radiography for Emergency Outpatients (응급환자의 방사선영상검사 분포 및 Patient Care)

  • Lee, Hwan-Hyung;Kang, Won-Han
    • Journal of radiological science and technology
    • /
    • v.19 no.1
    • /
    • pp.55-74
    • /
    • 1996
  • This study was carried out to improve service efficiency and to cope with a emergency situation in emergency radiography, through analysis of the radiographic distribution and literature cited about emergency care. Data collection of radiographic distribution was surveyed for 761 emergency outpatients who visit during JAN, 1994 at ER of the general hospital in Pusan city. The results is as follows: Emergency radiography rate of simple radiography was 61.1 %, special radiography 2.5 %, CT 12.6 %, and ultrasonography 6.7 %. In simple radiography rate, a high rate was distributed on male(63.6 %), thoracicsurgery part(90.0%), admission patient(74.9 %), and long stayed patient at ER. In special raiography rate, a high rate was observed in urologic part(28.6%), and in CT rate, observed neurosurgery part(49.2 %) and neurologic part(36.7%). Ultrasonography rate was high for female(8.8 %) and internal medicine part(15.9 %). There are distributed regional radiography rate in radiographic type that chest(55.3 %) is high in the simple radiography, urinary system(1.2%) in the special study, and brain(40.0 %) in the CT. Regional radiography rate according to diagnostic department also was showed highly for head(64.6%) in neurosurgery, chest(90.0%) in thoracic-surgery, abdomen(58.0%) in general-surgery, spine (40.0% ) in neuro-surgery, and pelvis(15.9%), upper extrimity(20.5%), and lower extrimity(31.8%) in orthopedic-surgery each. Mean radiographic case number per patient of simple radiography was sinificant on sex, age, transfer relation in both total and radiographic patients(p<0.05). Mean radiographic case number was highly distributed on male(2.2 case number) in sex, on thirties(2.7) in age, transfered patient(2.7) in patient type, and on neurosurgery(3.4) in diagnostic charged part. Total radiographic case number in regional part was highly distributed on chest(499 case number). Considering the above results, emergency radiographer should take care of the elder patient in emergency radiography and get hold of injury mechanism to decrease possible secondary injury during radiography. Because of high radiography rate of urinary system in special study, radiographer should know well about dealing with contrastmedia administration and related instrument. All radiographer who take charge emergency patient should cope with a emergency situation during radiography, Because head trauma patients is very important in patient care, especilly in CT at night, charged doctor should be always silted with CT room and monitoring-patient. Radiography was reqested by many diagnostic department in ER. Considering that rate of simple radiography is high, special room for emergency radiography should be established in ER area, and the radiographer of this room should be stationed radiologic technician who is career and can implement emergency patient care.

  • PDF

Optimum Angle of Incidence for General Anteroposterior Radiographic Image According to Lordosis angle : For Obese People

  • Kwak, Jong Hyeok;Kim, Gyeong Rip;Cho, Hee Jung;Moon, Sung Jin;Lee, Eun Sook;Sung, Soon Ki
    • International Journal of Contents
    • /
    • v.17 no.1
    • /
    • pp.18-26
    • /
    • 2021
  • The obesity leads to be the result of the weakening of anatomical structure as well as the gravity effect. And, the obesity interferes with normal sagittal balance and fails to maintain a straight posture with minimal energy. Therefore, the obesity can be an important factor in causing back pain by changing the lumbar lordosis. In this study, we will present an appropriate angle of incidence for obese people to reduce the image distortion of L4, L5 during a general anteroposterior radiography examination. To reduce image distortion according to the change of lordosis, the angle of incidence was applied 9 ° and 21 ° to L4 and L5 vertebra body when obesity and low back pain (LBP) perform the general anteroposterior radiography examination.

A absorbed and effective dose from the full-mouth periapical radiography using portable dental x-ray machine and panoramic radiography (ORIGINAL ARTICLE - 이동형 구내방사선촬영기로 촬영한 치근단 방사선촬영과 파노라마방사선촬영의 흡수선량과 유효선량 평가)

  • Han, Won-Jeong
    • The Journal of the Korean dental association
    • /
    • v.50 no.7
    • /
    • pp.420-430
    • /
    • 2012
  • Purpose: The purpose of this study was to measure the absorbed dose and to calculate the effective dose for full-mouth periapical radiography using the portable dental x-ray machine and panoramic radiography Material and Method: Thermoluminescent chips were placed at 25sites throughout the layers of the head and neck of a tissue-equivalent human skull phantom. The man phantom was exposed with the portable dental x-ray machine and panoramic unit. During full-mouth periapical radiography the exposure setting was 60 kVp, 2 mA and 0.15 ~ 0.25 seconds, while during panoramic radiography the selected exposure setting was 72 kVp, 8 mA and 18 seconds. Absorbed dose measurements were obtained and equivalent doses to individual organs were summed using ICRP 103 to calculate of effective dose. Result: In the full-mouth periapical radiography, the highest absorbed dose was recorded at the mandible body follow with submandibular glands and cheek. Using panoramic unit, the highest absorbed dose was parotid glands and the following was back of neck and submandibular glands. The effective dose in full-mouth periapical radiography using portable dental x-ray machine was 46 ${\mu}Sv$. In panoramic radiography, the effective dose was 38 ${\mu}pSv$. Conclusion: It was recommended to panoramic radiography for general check in the head and neck area because that the effect dose in the panoramic radiography was lower than the dose in the full-mouth periapical radiography using portable dental x-ray machine.

A New Attempt on Spot Radiography Using Cu Mask (동판을 이용한 Spot 촬영법에 관한 새로운 시도)

  • Kim, Chung-Min;Kang, Hong-Seok;Lee, In-Ja;Shin, Wha-Soo;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.10 no.1
    • /
    • pp.37-41
    • /
    • 1987
  • Authors could recognize surrounding areas induding target area by the observable film density with spot radiography using Cu mask and also, radiographic images maintained high quality. Spot radiography has been utilized for a long time for the purpose of observing detail image by the control of scattered radiation. But it has been difficult to know body part in general spot radiography. Therefore it is thought that attempt to use Cu mask in spot radiography is very advantageous in a clinical examinations.

  • PDF

A Study on the Scattered Dose in Portable Chest Radiography (portable 흉부촬영시 공간산란선량에 관한 연구)

  • Ahn, Bong-Seon;Lee, Hwan-Hyung
    • Journal of radiological science and technology
    • /
    • v.23 no.2
    • /
    • pp.63-67
    • /
    • 2000
  • The purpose of this study is to survey the present status of portable radiography and the result of free space scattered dose rate when taking a radiography at the general hospital or the university hospital in Taejon city. The results were as follows; 1. The number of cases using portable radiography for three years increased to averages 16.2%, 7.7% per year from January 1st in 1996 to December 31st in 1998. 2. The average of distance of adjacent patients was 219.1 cm at the ward. 3. For portable chest radiography, the free space scattered dose rate was 10.5 mSv/hr at 50 cm distance, 1.8 mSv/hr at 100 cm distance, and 0.2 mSv/hr at 200 cm distance. Therefore, in case of portable chest radiography at the ward, the average of distance of adjacent patients is 219.1 cm, so it does not have influence on the adjacent patients. But during the portable radiography, a guardian who is close to the patient, doctor, nurse and radiologic technologists has to set up the shield to prevent from the unnecessary radiation or the distance should be as great as possible from the mobile X-ray equipment.

  • PDF

Characterization of a Neutron Beam Following Reconfiguration of the Neutron Radiography Reactor (NRAD) Core and Addition of New Fuel Elements

  • Craft, Aaron E.;Hilton, Bruce A.;Papaioannou, Glen C.
    • Nuclear Engineering and Technology
    • /
    • v.48 no.1
    • /
    • pp.200-210
    • /
    • 2016
  • The neutron radiography reactor (NRAD) is a 250 kW Mark-II Training, Research, Isotopes, General Atomics (TRIGA) reactor at Idaho National Laboratory, Idaho Falls, ID, USA. The East Radiography Station (ERS) is one of two neutron beams at the NRAD used for neutron radiography, which sits beneath a large hot cell and is primarily used for neutron radiography of highly radioactive objects. Additional fuel elements were added to the NRAD core in 2013 to increase the excess reactivity of the reactor, and may have changed some characteristics of the neutron beamline. This report discusses characterization of the neutron beamline following the addition of fuel to the NRAD. This work includes determination of the facility category according to the American Society for Testing and Materials (ASTM) standards, and also uses an array of gold foils to determine the neutron beam flux and evaluate the neutron beam profile. The NRAD ERS neutron beam is a Category I neutron radiography facility, the highest possible quality level according to the ASTM. Gold foil activation experiments show that the average neutron flux with length-to-diameter ratio (L/D) = 125 is $5.96{\times}10^6n/cm^2/s$ with a $2{\sigma}$ standard error of $2.90{\times}10^5n/cm^2/s$. The neutron beam profile can be considered flat for qualitative neutron radiographic evaluation purposes. However, the neutron beam profile should be taken into account for quantitative evaluation.