• Title/Summary/Keyword: General X-ray

Search Result 554, Processing Time 0.026 seconds

Effect of Heat Treatment on the Surface Machined by W-EDM (고온 열처리가 와이어 컷 가공면에 미치는 영향)

  • Choi, K.K.;Lee, Y.S.
    • Transactions of Materials Processing
    • /
    • v.15 no.8 s.89
    • /
    • pp.539-543
    • /
    • 2006
  • Experimental studies are carried out in order to investigate the effects of heat treatment on the surface machined by W-EDM. In this work, two ways of heat treatment after W-EDM are considered. As a comparison, the machined surface by a traditional method such as milling/grinding is also considered. Thereby, specimens are prepared by four different machining methods. Those are (1) milling and then grinding, (2) wire-cut electric discharge machining (W-EDM), and (3) low temperature heat treatment or (4) high temperature heat treatment after W-EDM. The resulting surface roughness are measured and the changes of surface microstructures are investigated using the scanning electron microscope (SEM) with energy dispersive X-ray spectrometer (EDS). In general, heat treatment after W-EDM result in smoother surface and better chemical composition at the machined surface. Especially, high temperature tempering could remove defects in the thermally affected zone, which cause an overall deterioration of the surface machined by W-EDM.

Electron Beam Welding Diagnosis Using Wavelet Transform (웨이브렛 변환을 이용한 전자빔 용접 진단)

  • 윤충섭
    • Journal of Welding and Joining
    • /
    • v.21 no.6
    • /
    • pp.33-39
    • /
    • 2003
  • Wavelet transform analysis results show a spectrum energy distribution of CWT along scale factors distinguish the partial, full and over penetration in a electron beam welding by analyzing the curve of spectrum energy at small scale, middle and large scale range, respectively. Two types of signals collected by Ion collector and x-ray sensors and analyzed. The acquired signals from sensors are very complicated since these signals are very closely related the dynamics of keyhole which interact the very high density energy with materials during welding. The results show the wavelet transform is more effective to diagnosis than Fourier Transform, further for the general welding defects which are not a periodic based, but a transient, non-stationary and time-varying phenomena.

POLARIZATION AND POLARIMETRY: A REVIEW

  • Trippe, Sascha
    • Journal of The Korean Astronomical Society
    • /
    • v.47 no.1
    • /
    • pp.15-39
    • /
    • 2014
  • Polarization is a basic property of light and is fundamentally linked to the internal geometry of a source of radiation. Polarimetry complements photometric, spectroscopic, and imaging analyses of sources of radiation and has made possible multiple astrophysical discoveries. In this article I review (i) the physical basics of polarization: electromagnetic waves, photons, and parameterizations; (ii) astrophysical sources of polarization: scattering, synchrotron radiation, active media, and the Zeeman, Goldreich-Kylafis, and Hanle effects, as well as interactions between polarization and matter (like birefringence, Faraday rotation, or the Chandrasekhar-Fermi effect); (iii) observational methodology: on-sky geometry, influence of atmosphere and instrumental polarization, polarization statistics, and observational techniques for radio, optical, and $X/{\gamma}$ wavelengths; and (iv) science cases for astronomical polarimetry: solar and stellar physics, planetary system bodies, interstellar matter, astrobiology, astronomical masers, pulsars, galactic magnetic fields, gamma-ray bursts, active galactic nuclei, and cosmic microwave background radiation.

Diagnosis and treatment of obstructive atelectasis after general anesthesia in a patient with abscess in the maxillofacial area: A case report

  • Um, Byung-Koo;Ku, Jeong-Kui;Kim, Yong-Soo
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.18 no.4
    • /
    • pp.271-275
    • /
    • 2018
  • The purpose of this study was to report and discuss the diagnosis and treatment of obstructive atelectasis secondary to pus obstruction in a patient who had developed a maxillofacial abscess, and to review the literature on similar cases. Persistently discharging pus within the oral cavity can act as an aspirate, and may lead to obstructive atelectasis. Additionally, maxillofacial surgery patients should be carefully assessed for the presence of risk factors of obstructive atelectasis, such as, epistaxis after nasotracheal intubation, oral bleeding, and mucus secretion. Furthermore, patients with these risk factors should be continuously followed up by monitoring $SPO_2$, breath sounds, and chest x-ray.

Research of operators and patients exposed to electromagnetic field in the hospital (병원에서의 환자, 의료진의 전자파 노출 실태 조사)

  • Ji, Hyo-Chul;Hong, Hyun-Ki;Kim, Sung-Woo;Lee, Ju-Hyung;Kim, Deok-Won
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.70-72
    • /
    • 2007
  • In this study, electromagnetic fields emitted from the various environment in the hospital were measured. Measurement spot was patients' head. To monitor how much magnetic fields are emitting from operation room, monitoring device was attached to 19 anesthesiologist and monitoring lasted 8 hours. We also took a measurement from various medical devices. Devices include ESWL, PET, MRI, CT, Gamma knife, X-ray, Angiogram, Echocardiogram, Upper GI and Linear Accelerator. Electromagnetic fields were measured from 10 spots from each of 5 patient waiting room. As a results, there were no places showing risk of high exposure. All the measurement values were below the reference levels for general public exposure to time varying electric and magnetic fields which is issued by ICNIRP.

  • PDF

Patient Radiation Exposure Dose in Computed Tomography (전산화단층촬영장치에서 환자피폭선량)

  • Cho, Pyong Kon
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.2
    • /
    • pp.109-115
    • /
    • 2015
  • In case of a CT examinations, there is a difference in the distribution of radiation dose from that of general X-ray equipments, and it has been known to cause a great radiation exposure during the examinations. However, owing to its high reliability on the accuracy of a examinations result, its use has increased continuously. In consideration of such a circumstance, the CT equipment, radiation dose during CT examinations, diagnostic reference level, and solutions to reduce radiation dose were mentioned on the basis of previously reported data.

Oral cancer diagnosed using PET/CT: A case report (PET/CT를 이용하여 진단한 구강암의 증례)

  • Kim Young-Hee;Yang Byoung-Eun;Cho Young-Min;Kim Seong-Gon
    • Imaging Science in Dentistry
    • /
    • v.36 no.2
    • /
    • pp.111-116
    • /
    • 2006
  • PET/CT is a new imaging technology that combines high-quality Positron Emission Tomography (PET) and Computed Tomography (CT). This imaging provides simultaneous anatomical and metabolic information. Therefore PET/CT is useful diagnostic modality for early detection of malignant tumor, accurate staging, decision on therapeutic plan, monitoring response to therapy and rapid detection of recurrence. We report oral and maxillofacial cancers diagnosed by using PET/CT and the usefulness of PET/CT in the evaluation of postoperative recurrence.

  • PDF

XPS STUDY ON DNA DAMAGE BY LOW-ENERGY ELECTRON IRRADIATION

  • Noh, Hyung-Ah;Cho, Hyuck
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.4
    • /
    • pp.190-194
    • /
    • 2011
  • After the first report that electrons with sub-ionization energy of DNA could cause single strand breaks or double strand breaks to DNA, there have been various studies to investigate the mechanisms of DNA damage by low-energy electrons. In this paper, we examined the possibility of using X-ray photoelectron spectroscopy (XPS) to analyze the dissociation patterns of the molecular bonds by electron irradiation on DNA thin films and tried to establish the method as a general tool for studying the radiation damage of biomolecules by low energ yelectrons. For the experiment, pBR322 plasmid DNA solution was formed into the films on tantalum plates by lyophilization and was irradiated by 5-eV electrons. Un-irradiated and irradiated DNA films were compared and analyzed using the XPS technique.

A Case of Left Pulmonary Artery Hypoplasia in Adult (성인에서 발견된 좌측 폐동맥 형성부전증 1례)

  • Lee, Seung-Hyun;Choi, Koang-Ho;Lee, Heung-Bum;Lee, Yong-Chul;Rhee, Yang-Keun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.1
    • /
    • pp.116-121
    • /
    • 1999
  • Unilateral hypoplasia of the pulmonary artery is an uncommon anomaly, which commonly develops in combination with congenital cardiovascular defects such as tetralogy of Fallot, patent ductus arteriosus and septal defect of atrium or ventricle, but may also present as an isolated lesion. We have recently experienced a case of the left pulmonary artery hypoplasia in adult by chance of during the general health screen, which diagnosed by chest X-ray, chest spiral CT, lung perfusion and ventilation scan, digital substraction angiogram and bronchoscopy, then presented hereby with the review of relevant literature.

  • PDF

- Development of Digital Fluoroscopic Image Recording System for Customer Safety - (고객 안전을 위한 디지털 방사선장치(DRF)의 투시영상기록장치 개발)

  • Rhim Jae Dong;Kang Kyong Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.6 no.3
    • /
    • pp.303-309
    • /
    • 2004
  • Many system devices for fluoroscopic and general X-ray studies in diagnostic radiographic system have been being changed from analog mode to digital mode. In addition, among diagnostic imaging and radiologic examinations, fluoroscopic studies that requires functional diagnosis is being widely used. The video recording method of fluoroscopic studies has been useful in functional image diagnosis and dynamic image observation, but the utility of its image quality is being reduced because of limitation in setting play segments of the video player, inconvenience of play, difficulties in preserving reproduced images, the change of image quality, etc. In order to complement these shortages, it is necessary to facilitate access to patient diagnosis information such as storing, editing and sharing functional diagnosis images in response to the trend of the digitalization of digital radiographic & fluoroscopic system(DRF). Thus this study designed and implemented a device of storing functional dynamic images real time using a computer rather than existing video recording, aiming at contribution to functional image diagnosis.