• 제목/요약/키워드: General X-ray

검색결과 552건 처리시간 0.032초

Small-Angle X-ray Scattering Station 4C2 BL of Pohang Accelerator Laboratory for Advance in Korean Polymer Science

  • Yoon, Jin-Hwan;Kim, Kwang-Woo;Kim, Je-Han;Heo, Kyu-Young;Jin, Kyeong-Sik;Jin, Sang-Woo;Shin, Tae-Joo;Lee, Byeong-Du;Rho, Ye-Cheol;Ahn, Byung-Cheol;Ree, Moon-Hor
    • Macromolecular Research
    • /
    • 제16권7호
    • /
    • pp.575-585
    • /
    • 2008
  • There are two beamlines (BLs), 4C1 and 4C2, at the Pohang Accelerator Laboratory that are dedicated to small angle X-ray scattering (SAXS). The 4C1 BL was constructed in early 2000 and is open to public users, including both domestic and foreign researchers. In 2003, construction of the second SAXS BL, 4C2, was complete and commissioning and user support were started. The 4C2 BL uses the same bending magnet as its light source as the 4C1 BL. The 4C1 BL uses a synthetic double multilayer monochromator, whereas the 4C2 BL uses a Si(111) double crystal monochromator for both small angle and wide angle X-ray scattering. In the 4C2 BL, the collimating mirror is positioned behind the monochromator in order to enhance the beam flux and energy resolution. A toroidal focusing mirror is positioned in front of the monochromator to increase the beam flux and eliminate higher harmonics. The 4C2 BL also contains a digital cooled charge coupled detector, which has a wide dynamic range and good sensitivity to weak scattering, thereby making it suitable for a range of SAXS and wide angle X-ray scattering experiments. The general performance of the 4C2 BL was initially tested using standard samples and further confirmed by the experience of users during three years of operation. In addition, several grazing incidence X-ray scattering measurements were carried out at the 4C2 BL.

A Study on Exposure to radiation of the patient who visited an emergency room at a University Hospital (한 대학병원 응급실에 방문한 환자의 방사선 피폭에 관한 연구)

  • Ahn, Buyung-Ju;Lee, Sang-Bock;Lee, Jun-Haeng
    • Journal of the Korean Society of Radiology
    • /
    • 제1권3호
    • /
    • pp.23-34
    • /
    • 2007
  • To find how much radiation was exposed the patients who visit emergency room, a measurement study was made for radiation amount toward 200 patients selected randomly among visitors to an emergency room in a university hospital from March 16 to 31st, 2006. The results are as follows ; 1. Among the subjects 50 person(25.0%) were transferred from other hospitals, 24 persons(8.3) come after traffic accident, 50 persons for other accident and 76 persons for general medical care. 2. The average frequency of X-ray taking was calculated as 6.4 time per person among transferred patients, 14.5 times per person among patients with traffic accident and 2.6 times per person among general medical care. 3. The radiation exposure amount by kind of X-ray showed 28.9mGyfor general X-ray diagnosis, 84.2mGy for CT scanning and 1.02mGy for other special radiation study. 4. Average radiation exposure amount was calculated as 24.6mGy by transferred patients, 55.2mGy by patients with traffic accident, 17.1mGy by patients with other accidents and 17.0mGy by general patients. 5. Through the comparison of radiation exposure amount among to subject with maximum allowance threshold by International Commission on X-ray Radium Protection, transferred patients exceeded 6 times than allowance in whole body except extremities and joints, blood forming organ, reproductive system, vitreous body of eye, bone, thyroid gland, skin and etc, Patient suffered from traffic accidents were exposed 10 times more than allowance. In conclusion, the radiation exposure amount during X-rat diagnosis re too much and exceeded allowance standard by International Commission on X-ray Radium Protection. So further study and preventive measure to decrease radiation exposure by patients who visit emergency room.

  • PDF

Kinetic Analysis of Foot Balance and Gait Patterns in Patients with Adult Spinal Disease (성인 척추질환자의 발균형 및 보행형태에 대한 운동역학적 분석)

  • Park, Jae Soung;Lee, Joong Sook
    • Korean Journal of Applied Biomechanics
    • /
    • 제29권1호
    • /
    • pp.23-32
    • /
    • 2019
  • Objective: The aim of this study was to provide kinematic data on the characteristics of spinal disease patients by comparing and analyzing kinematic variables related to foot balance and gait pattern of spinal disease. Method: The subjects of the study included 40 adult men and 60 adult women who visited the hospital in Busan. Patients who were diagnosed with spinal disease by a physician through X-ray examination were selected as subjects for the diagnosis of vertebral disc herniation, spinal stenosis, spinal disease diagnosed with spinal disease and the general public. Left and right foot pressure and contact area were checked by Gaitview pro meter. X-ray photographs were taken with a Zen-2090 mobile fluoroscopy under physicians' direct participation. One-way ANOVA was performed to compare the differences between the kinematic variables and post-hoc was performed by the Duncan method. Results: The difference in contact area between the left foot and the right foot was $115.30{\pm}14.15cm^2$ in the left side and $124.25{\pm}13.65cm^2$ in the left side in the spinal disease patients. The difference in pressure between the left and right side of the spinal disease patients was wider than that of the general people. Especially, the right side of the spinal disease patients showed a larger area of left foot contact than the general population. Conclusion: Spinal disease patients have wider contact area of the left foot than those of the general population. In the case of right spinal disease, the left foot support area is widened due to pain. In the gait, women showed slightly more posterior body center than men, and the upper body muscle imbalance and immobilization due to the spinal disease caused imbalance of the muscles moving to the lower limb, It was analyzed to inhibit movement.

Studies of Nonstoichiometry and Physical Properties of the Perovskite $Sm_{1-x}Sr_xCoO_{3-y}$ System

  • 강진우;류광현;여철현
    • Bulletin of the Korean Chemical Society
    • /
    • 제16권7호
    • /
    • pp.600-603
    • /
    • 1995
  • A series of samples in the Sm1-xSrxCoO3-y(x=0.00, 0.25, 0.50, 0.75 and 1.00) system has been prepared at 1200 ℃ under ambient atmosphere. The X-ray diffraction patterns of the samples with x=0.00 and 0.25 are indexed with orthorhombic symmetry like GdFeO3 and x=0.50 appears to be perfectly cubic. In the tetragonal system (x=0.75), the structure is similar to that of SrCoO2.80. The composition of x=1.00, SrCoO2.52, shows the brownmillerite-type structure. The reduced lattice volume is increased with x value in this system. The chemical analysis shows the τ value (the amount of the Co4+ ions in the system) is maximized at the composition of x=0.50. Nonstoichiometric chemical formulas are determined by the x, τ and y values. The electrical conductivity has been measured in the temperature range of 78 to 1000 K. The activation energy is minimum for those of x=0.25 and x=0.50 with metallic behavior. First-order semiconductor-to-metal transition of SmCoO3 is not observed. Instead, a broad, high-order semiconductor-to-metal transition is observed. In general, the effective magnetic moment is increased with increasing τ values at low temperature. At high temperature, the magnetic moment is maximum for that of x=0.00. The 3d-electrons are collective and give ferromagnetism in x=0.50.

Health Problem of the Middle-Aged Women (종합 건강검진 과정에서 나타난 일부 중년기 여성의 건강문제)

  • 성미혜
    • Journal of Korean Academy of Nursing
    • /
    • 제29권2호
    • /
    • pp.258-270
    • /
    • 1999
  • This study was carried out to offer the basic data for more qualitative lives of the middle-aged women through their health maintenance and control. So, the researcher reviewed and analyzed the health problems of the middle-aged women, the differences of main symptoms in each subject, positive ratcs in screening tests, the difference of screening tests with age and the correlation of obesity and blood pressure with screening tests. All subjects were 218 women(40-59years) who had a check-up at a comprehensive health check-up center in K University Hospital in Seoul from July 1, 1998 to August 31. 1998. Questionaires were developed to get subjects, general characteristics. main symptoms, medical examination and diagnosed disease by the researcher referring through the questionaires of comprehensive health check-up center and the medical recorders were used as a tool of study. The researcher analyzed the data with SPSS PC+ ; the distribution of the subjects, general characteristics and main symptoms with percentage : the difference between main symptoms and screening tests with X$^2$-test, ANOVA. The results are as follows. 1) Among the age distribution, most were 40-45 years old and unemployed. 2) The most common complaints were indigestion in digestive system, cough in respiratory system, heart beat in cardiovascular system, general sweat in endocrine system. edema in urinary system, easy bruise in hematologic system, backache in musculoskeletal system, headache in psychoneurologic system, lochia in gynecology, itch in dermatology system, eye ball pain in visual system and tinnitus in auditory system. 3) In main symptoms according to age, the 40-45 age group had a higher rate of complaints in digestive system and gynecology than other age group ; the 46-49 age group in endocrine system. 4) The main symptoms according to diagnosis had no difference statistically. 5) The screening tests which showed high rates of abnormality were mammography(the highest), abdominal ultrasonography, upper gastrointestinal series/gastrofiberscopy, PFT. In all age group the highest rate of abnormality was seen in mammography. 6) In screening tests according to age. the 46-49 age group showed higher positive rates of pap smear, blood sugar test, urine test than any other age group ; the 50-55 age group showerd higher positive rates of obesity, BP, chest X-ray, abdominal ultrasonography, ESR, SGOT, CRP and urine micro. 7) In correlation of obesity with screening test, the obesity group showed higher positive rates of blood pressure, chest X-ray, abdominal ultrasonography, HCT and CRP than the normal weight group. 8) In correlation of blood pressure with screening test, the hypertension group showed higher positive rate of obesity, chest X-ray, abdominal ultrasonography, pap smear and blood sugar than the normal blood pressure group. In conculusion, the middle-aged women have various physical symptoms and affected by age. The obesity and BP have an important effect on the health of the middle aged women. Therefore, this study is considered significant as data for qualitative lives of the middle-aged women playing an important part of family health care by catching of their health problem complaints for prevention of disease and promotion of health.

  • PDF

Clinical Outcomes and Cost-Effectiveness of Osteoporosis Screening With Dual-Energy X-ray Absorptiometry

  • Chiao-Lin Hsu;Pin-Chieh Wu;Chun-Hao Yin;Chung-Hwan Chen;King-Teh Lee;Chih-Lung Lin;Hon-Yi Shi
    • Korean Journal of Radiology
    • /
    • 제24권12호
    • /
    • pp.1249-1259
    • /
    • 2023
  • Objective: This study aimed to evaluate the clinical outcomes and cost-effectiveness of dual-energy X-ray absorptiometry (DXA) for osteoporosis screening. Materials and Methods: Eligible patients who had and had not undergone DXA screening were identified from among those aged 50 years or older at Kaohsiung Veterans General Hospital, Taiwan. Age, sex, screening year (index year), and Charlson comorbidity index of the DXA and non-DXA groups were matched using inverse probability of treatment weighting (IPTW) for propensity score analysis. For cost-effectiveness analysis, a societal perspective, 1-year cycle length, 20-year time horizon, and discount rate of 2% per year for both effectiveness and costs were adopted in the incremental cost-effectiveness (ICER) model. Results: The outcome analysis included 10337 patients (female:male, 63.8%:36.2%) who were screened for osteoporosis in southern Taiwan between January 1, 2012, and December 31, 2021. The DXA group had significantly better outcomes than the non-DXA group in terms of fragility fractures (7.6% vs. 12.5%, P < 0.001) and mortality (0.6% vs. 4.3%, P < 0.001). The DXA screening strategy gained an ICER of US$ -2794 per quality-adjusted life year (QALY) relative to the non-DXA at the willingness-to-pay threshold of US$ 33004 (Taiwan's per capita gross domestic product). The ICER after stratifying by ages of 50-59, 60-69, 70-79, and ≥ 80 years were US$ -17815, US$ -26862, US$ -28981, and US$ -34816 per QALY, respectively. Conclusion: Using DXA to screen adults aged 50 years or older for osteoporosis resulted in a reduced incidence of fragility fractures, lower mortality rate, and reduced total costs. Screening for osteoporosis is a cost-saving strategy and its effectiveness increases with age. However, caution is needed when generalizing these cost-effectiveness results to all older populations because the study population consisted mainly of women.

Comparison of the Modulation Transfer Function of Several Image Plate (Image Plate(IP) 영상의 MTF 비교)

  • Kim, Chang-Bok;Lee, Yang-Sup;Kim, Young-Keun;Lee, Seong-Kil;Lee, Kyung-Sup
    • Journal of radiological science and technology
    • /
    • 제27권3호
    • /
    • pp.25-29
    • /
    • 2004
  • Among the digital radiography systems, the computed radiography Image Plate Detector System is most frequently being used for the general radiography and also this system commonly diffracts the x-ray images since it is the system that is influenced by the light diffusion from the fluorescent substances. In this study, by using the X-ray Generator, a comparative analysis has been made between 2 different models of computer radiography image plate investigate each model's resolution and sharpness through the modulation transfer function(MTF) measurement. For the analysis, two image plates for general radiography one Fuji ST-VN model(more than 3years old) and one Fuji ST-VL model(less than 2years old) that are currently being used in "Hospital A" were sampled for the MTF measurement here. As the experimental method for this study, the resolution chart method has been carried out by using X-ray generator. Also all the experimental data were printed out by laser printer and measured by microdensitometer. As the results of the experiment carried out in this study, some differences have been found between the two different IP models and Fuji ST-VL has shown its excellence in both of the resolution and the sharpness fields.

  • PDF

Treatment of flat foot with Kalix implant - case report - (Kalix implant를 이용한 편평족의 치료 - 증례보고 -)

  • Lee, Kyung-Tai;Young, Ki-Won;Bae, Sang-Won;Tak, Sang-Bo;Lee, Seung-Hwan
    • Journal of Korean Foot and Ankle Society
    • /
    • 제6권2호
    • /
    • pp.238-241
    • /
    • 2002
  • There are two types of flat foot, the one is congenital type and the other is acquired type. The treatments of flat foot are various and conservative treatment is general, except such as congenital talus. But, operative method is needed for treatment of failure of conservative method, severe deformity in X-ray, with tenderness in a juvenile period. We reported using Kalix implant for flat foot with pain and severe deformity.

  • PDF

Evaluation of Image Qualities for a Digital X-ray Imaging System Based on Gd$_2$O$_2$S(Tb) Scintillator and Photosensor Array by Using a Monte Carlo Imaging Simulation Code (몬테카를로 영상모의실험 코드를 이용한 Gd$_2$O$_2$S(Tb) 섬광체 및 광센서 어레이 기반 디지털 X-선 영상시스템의 화질평가)

  • Jung, Man-Hee;Jung, In-Bum;Park, Ju-Hee;Oh, Ji-Eun;Cho, Hyo-Sung;Han, Bong-Soo;Kim, Sin;Lee, Bong-Soo;Kim, Ho-Kyung
    • Journal of Biomedical Engineering Research
    • /
    • 제25권4호
    • /
    • pp.253-259
    • /
    • 2004
  • in this study, we developed a Monte Carlo imaging simulation code written by the visual C$\^$++/ programing language for design optimization of a digital X-ray imaging system. As a digital X-ray imaging system, we considered a Gd$_2$O$_2$S(Tb) scintillator and a photosensor array, and included a 2D parallel grid to simulate general test renditions. The interactions between X-ray beams and the system structure, the behavior of lights generated in the scintillator, and their collection in the photosensor array were simulated by using the Monte Carlo method. The scintillator thickness and the photosensor array pitch were assumed to 66$\mu\textrm{m}$ and 48$\mu\textrm{m}$, respertively, and the pixel format was set to 256 x 256. Using the code, we obtained X-ray images under various simulation conditions, and evaluated their image qualities through the calculations of SNR (signal-to-noise ratio), MTF (modulation transfer function), NPS (noise power spectrum), DQE (detective quantum efficiency). The image simulation code developed in this study can be applied effectively for a variety of digital X-ray imaging systems for their design optimization on various design parameters.

2D Location Estimation of a Magnetized Tip Using Arrayed GMR Sensors (GMR센서 배열을 이용한 자석팁의 2D 위치 추정)

  • Lee, S.C.;Kim, J.K.;Ahn, J.H.;Kim, H.Y.
    • Journal of Sensor Science and Technology
    • /
    • 제28권6호
    • /
    • pp.395-401
    • /
    • 2019
  • This paper proposes a method for estimating the location of a magnetized tip that is inside a non-transparent space or body by using arrayed giant magnetoresistance (GMR) sensors. In general, an object located in such an opaque space can be detected using X-rays, magnetic fields, ultra-sonic sensors, etc., depending on its characteristics. X-ray is mostly used for medical purposes but frequent exposure to it could cause harm to patients as well as doctors. In this study, how well a GMR sensor is applicable instead of an X-ray is investigated. The sensor's voltage output is experimentally fitted to distance with a relationship of 3rd degree polynomial. To detect a small magnetized tip with 900 Oe inside a human body, a 2×2 arrayed GMR sensor and a location estimation algorithm based on information acquired from four sensors is developed. Evaluation tests show that the suggested method is applicable to limited cases with a distance less than 33-55 mm, and the location of a magnet tip is estimated relatively well with an error less than 1.5 mm.