DOI QR코드

DOI QR Code

2D Location Estimation of a Magnetized Tip Using Arrayed GMR Sensors

GMR센서 배열을 이용한 자석팁의 2D 위치 추정

  • Lee, S.C. (School of Mechtronical Engineering, Pusan National Unversity) ;
  • Kim, J.K. (School of Mechtronical Engineering, Pusan National Unversity) ;
  • Ahn, J.H. (School of Mechtronical Engineering, Pusan National Unversity) ;
  • Kim, H.Y. (School of Mechtronical Engineering, Pusan National Unversity)
  • Received : 2019.10.23
  • Accepted : 2019.11.27
  • Published : 2019.11.30

Abstract

This paper proposes a method for estimating the location of a magnetized tip that is inside a non-transparent space or body by using arrayed giant magnetoresistance (GMR) sensors. In general, an object located in such an opaque space can be detected using X-rays, magnetic fields, ultra-sonic sensors, etc., depending on its characteristics. X-ray is mostly used for medical purposes but frequent exposure to it could cause harm to patients as well as doctors. In this study, how well a GMR sensor is applicable instead of an X-ray is investigated. The sensor's voltage output is experimentally fitted to distance with a relationship of 3rd degree polynomial. To detect a small magnetized tip with 900 Oe inside a human body, a 2×2 arrayed GMR sensor and a location estimation algorithm based on information acquired from four sensors is developed. Evaluation tests show that the suggested method is applicable to limited cases with a distance less than 33-55 mm, and the location of a magnet tip is estimated relatively well with an error less than 1.5 mm.

Keywords

References

  1. M. H. Kang "An Ultrasonic Positioning System Using Zynq SoC", The Transactions of the Korean Institute of Electrical Engineers., Vol. 66, No. 8, pp. 1250-1256, 2017.
  2. T. B. Lee and H. S. Kang, "Material Estimation Method Using Dual-Energy X-Ray Image for Cargo Inspection System", Journal of the Korea Industrial Information Systems Research., Vol. 23, No. 1, pp. 1 - 12, 2018. https://doi.org/10.9723/jksiis.2018.23.1.001
  3. D. Hong and W. Woo, "Recent research trend of gesturebased user interfaces", Telecommun. Rev., Vol. 18, No. 3, pp. 403-413, 2008.
  4. C. D. Natali, M. Beccani, and P. Valdastri, "Real-Time Pose Detection for Magnetic Medical Devices", IEEE Transac. Magn., Vol. 49, No. 7, pp. 3524 - 3527, 2013. https://doi.org/10.1109/TMAG.2013.2240899
  5. J. Daughton, J. Brown, E. Chen, R. Beech, A. Pohm, and W. Kude, "Magnetic field sensors using GMR multilayer", IEEE Transac. Magn., Vol. 30, No. 6, pp. 4608-4610, 1994. https://doi.org/10.1109/20.334164
  6. J. M. Daughton, "GMR applications", J. Magn. Magn. Mater., Vol. 192, No. 2, pp. 334-342, 1999. https://doi.org/10.1016/S0304-8853(98)00376-X
  7. S. C. Mukhopadhyay, K. Chomsuwan, C. P. Gooneratne, and S. Yamada, "A Novel Needle-Type SV-GMR Sensor for Biomedical Applications", IEEE Sens. J., Vol. 7, No. 3, pp. xx-yy, 2007.
  8. J. Lenz and A. S. Edelstein, "Magnetic Sensors and Their Applications", IEEE Sens. J., Vol. 6, No. 3, pp. 631-649, 2006. https://doi.org/10.1109/JSEN.2006.874493
  9. A. Anguelouch, D. H. Reich, C. L. Chien, and M. Tondra, "Detection of ferromagnetic nanowires using GMR sensors", IEEE Transac. Magn., Vol. 40, No. 4, pp. 2997-2999, 2004. https://doi.org/10.1109/TMAG.2004.829316
  10. V. Schlagetera, P.-A. Bessea, R. S. Popovica, and P. Kucerab, "Tracking system with five degrees of freedom using a 2D-array of Hall sensors and a permanent magnet", Sens. Actuators A, Vol. 92, No. 1-3, pp. 37-42, 2001. https://doi.org/10.1016/S0924-4247(01)00537-4
  11. P.-H. Tichit, S. N. Burokur, and A. de Lustrac, "Waveguide taper engineering using coordinate transformation technology", Opt. Express, Vol. 18, No. 2, pp. 767-772, 2010. https://doi.org/10.1364/OE.18.000767
  12. S. K. Kwon and D. M. Lee, "Performance Analysis of Compensation Algorithm for Localization using Equivalent Distance Rate", J. Korea Acad. Ind. Coop. Soc., Vol. 11, No. 4, pp. 1248-1253, 2010. https://doi.org/10.5762/KAIS.2010.11.4.1248