• 제목/요약/키워드: Gel polymer

검색결과 618건 처리시간 0.025초

Effect of PEO of PS-P2VP photonic gel films

  • Shin, Sung-Eui;Kim, Su-Young;Shin, Dong-Myung
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.1405-1407
    • /
    • 2009
  • We prepared polystyrene-b-poly(2-vinyl pyridine) (PSb-P2VP) lamellar films which is hydrophobic block-hydrophilic polyelectrolyte block polymer have 57 kg/mol-b-57 kg/mol. The result of UV-visible absorption spectra supported that effect of poly(ethylene oxide) on the band gap tuning of PS-P2VP photonic gel like salt effect.

  • PDF

X-ray CT Scanner를 이용한 MAGAT (Methacrylic Acid, Gelatin Gel and THPC) 중합체 겔 선량계의 선량 반응성 연구 (A Study on Dose Response of MAGAT (Methacrylic Acid, Gelatin Gel and THPC) Polymer Gel Dosimeter Using X-ray CT Scanner)

  • 정재용;이충일;민정환;김연래;이성용;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제21권1호
    • /
    • pp.1-8
    • /
    • 2010
  • CT 촬영 장치를 기반으로 한 MAGAT (Methacrylic Acid, Gelatin gel And THPC) 정상 산소 중합체 겔 선량계의 화합물 조성비와 CT 영상 스캔 인자의 변화에 따른 선량 반응성을 평가하였다. 다양한 농도의 메타크릴산(MAA, MethAcrylic Acid)과 젤라틴을 조성하여 MAGAT 선량계를 제작하고 20 Gy까지의 방사선을 조사하였다. 조사된 겔 선량계는 CT 촬영 장치(Brilliance Big bore scanner, Phillps, Netherlands)를 이용하여 다양한 스캔 인자(관전압, 관전류, 단면두께)로 같은 위치에서 20회까지의 CT 영상을 획득하였다. 획득된 영상으로 $N_{CT}$-선량 반응곡선($N_{CT}$-dose response), 선량 감도(dose sensitivity), 선량 분해능(dose resolution)을 측정, 평가하였다. 각 조성비 별 MAGAT 선량계의 $N_{CT}$-선량 반응곡선에서 메타크릴산과 젤라틴의 양이 증가함에 따라 기울기와 절편이 증가하였다. 선량 감도는 $0.338{\pm}0.08$에서 $0.859{\pm}0.1$까지 나타났고 메타크릴산이 증가, 젤라틴이 감소할수록 증가하였으나 그 변화는 메타크릴산 농도의 증가에 따라 감도가 증가되는 것에 비해 아주 작은 변화를 보였다. 선량 분해능은 약 2.6에서 6 Gy까지 다양하게 나타났으며 감도와 영상 내의 노이즈에 의해 큰 변화를 보였다. 영상 스캔 인자의 변화에 대한 반응곡선은 관전압, 관전류, 단면두께의 변화에 따른 곡선의 기울기와 감도는 큰 변화를 보이지 않았으나 영상 내의 노이즈(평균 CT number의 표준편차)는 위의 3개의 인자가 증가할수록 감소함을 보였다. 본 연구는 CT 촬영장치를 이용한 MAGAT 중합체 겔의 선량 반응성을 평가하여 적정한 조성비와 스캔 인자를 얻을 수 있었으며 CT를 기반으로 한 3차원 선량계를 간단하고 효율적으로 임상에 적용할 수 있을 것으로 사료된다.

TiO2 Ceramic Filler가 혼합된 젤상의 PAN 고분자 전해질을 이용한 리튬금속 이차전지의 특성 (Characteristics of Lithium Metal Secondary Battery Using PAN Gel-electrolyte Mixed with TiO2 Ceramic Filler)

  • 임효성;김형선;조병원;이태희
    • 전기화학회지
    • /
    • 제5권3호
    • /
    • pp.106-110
    • /
    • 2002
  • Ethylene carbonate(EC), propylene carbonate(PC), dimethyl carbonate(DMC)의 가소제와 $LiPF_6$ 리튬염 및 $TiO_2$ 충진제를 이용하여 젤형 polyacrylonitrile(PAN) 전해질을 제조하였다. 고분자 전해질의 전기화학적 안정성, 이온전도도, 리튬전극과의 호환성 등의 전기화학적 특성과 기계적 특성을 조사하였다. 이러한 고분자 전해질을 이용하여 조립된 리튬이차전지의 충방전 특성을 조사하였다 EC, PC 혼합 가소제를 이용하여 제조된 고분자 전해질은 $TiO_2$가 첨가됨에 따라 고분자 전해질이 견딜 수 있는 최대 하중이 2배 가깝게 증가하였다. EC, PC혼합 가소제와 $TiO_2$가 혼합된 고분자 전해질은 상온에서 $2\times10^{-3}S/cm$의 이온전도도를 나타내었고, 4.5V까지 전기화학적으로 안정하였다. 리튬금속을 사용하여 제조된 셀의 임피던스 결과에서도 EC, PC 혼합 가소제와 $TiO_2$가 혼합된 고분자 전해질이 20일 동안 계면 저항 $130\Omega$으로 가장 안정하였다. $LiCoO_2$ 양극과 리튬 음극, $TiO_2$가 혼합된 고분자 전해질로 구성된 전지는 충방전효율이 1C 방전속도에서 $90\%$를 나타내었다.

수용성 폴리머 겔 전헤액을 사용한 Pseudocapacitor의 전기화학적 특성 (Electrochemical Characteristics of Pseudocapacitor Using Aqueous Polymeric Gel Electrolyte)

  • 박수길
    • 전기화학회지
    • /
    • 제6권2호
    • /
    • pp.158-160
    • /
    • 2003
  • We have reported to make nanostructured cobalt oxide electrode that have large capacitance over than 400 F/g (specific capacitance) and good cycleability. But, it had serious demerits of low voltage range under 0.5 V and low power density. Therefore, we need to increase voltage range of cobalt oxide electrode. We report here on the electrochemical properties of sol-gel-derived nanoparticulate cobalt xerogel in 1M KOH solution and aqueous polymeric gel electrolyte. In solution electrolyte, cobalt oxide electrode had over 250 F/g capacitance consisted of EDLC and pseudocapacitance. In gel electrolyte, cobalt oxide electrode had around 100 F/g capacitance. This capacitance was only electric double layer capacitance of active surface area. In solution electrolyte, potassium ion as working ion reacted with both of layers easily. However, In gel electrolyte, reacted with only surface-active layer. Itis very hard to reach resistive layer. So, we have studied on pretreatment of electrode to contain working ions easily. We'll report more details.

Delayed Detected Unexpected Complication of ADCON-$L^{(R)}$ Gel in Lumbar Surgery

  • Kim, Sung-Bum;Lim, Young-Jin
    • Journal of Korean Neurosurgical Society
    • /
    • 제48권3호
    • /
    • pp.268-271
    • /
    • 2010
  • The ADCON-L $gel^{(R)}$ (Gliatech, Cleveland, OH, USA), a carbohydrate polymer gel. has been shown in a controlled clinical study to inhibit postsurgical adhesions and improve a patient's clinical outcome. Immediate complication of this gel has been reported in the recent literature including back pain, radiculitis and durotomy. However, delayed detection of disturbance of muscle healing and attachment in late postoperative state has been rarely reported. This report documents an unexpected delayed detected complication of the anti-adhesion barrier gel. which was used after lumbar discectomy one year ago, with review of literature.

수퍼커패시터용 수용성 고분자 젤 전해질의 전기화학적 특성 (Electrochemical Characteristics of Aqueous Polymeric Gel Electrolyte for Supercapaictor)

  • 김한주;;;박수길
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집 Vol.14 No.1
    • /
    • pp.93-96
    • /
    • 2001
  • We have reported to make nanostructured cobalt oxide electrode that have large capacitance over than 400F/g (specific capacitance) and good cycleability. But, It had serious demerits of low voltage range under 0.5V and low power density. Therefore, we need to increase voltage range of cobalt oxide electrode. we report here on the electrochemical properties of sol-gel-derived nanoparticulate cobalt xerogel in 1M KOH solution and aqueous polymeric gel electrolyte. In solution electrolyte, cobalt oxide electrode had over than 250F/g capacitance consisted of EDLC and pseudocapacitance. In gel electrolyte, cobalt oxide electrode had around l00F/g capacitance. This capacitance was only surface EDLC. In solution electrolyte, potassium ion as working ion reacted with both of layers easily. However, In gel electrolyte, reacted with only surface-active layer. Its very hard to reach resistive layer. So, we have studied on pretreatment of electrode to contain working ions easily. We'll report more details.

  • PDF

친수성 정제의 겔층두께와 겔팽창 영역의 조직 특성화 (Textural Characterization of Gel Layer Thickness and Swelling Boundary in a Hydrophilic Compact)

  • 김현조;레자 파시히
    • Journal of Pharmaceutical Investigation
    • /
    • 제31권1호
    • /
    • pp.13-18
    • /
    • 2001
  • This study was to investigate the relationship between the gel layer thickness and swelling boundary via strength measurements using texture analysis. The novel texture analysis approach was used to examine the dynamics of swelling behavior in a ternary polymeric matrix tablet. The method permitted the characterization of the changes occurring at the peripheral as well as within interior boundary of the swelling during water ingress. The increase in gel strength for pectin, HPMC, and a ternary mixture with gelatin was found to depend on polymer concentration. Therefore, this method is further applicable to characterize the swelling behavior and provide opportunity to differentiate the gel-layer from that of swelling boundary.

  • PDF