• Title/Summary/Keyword: Gear Mechanism

Search Result 171, Processing Time 0.032 seconds

Kinematic Analysis and Implementation of a Spherical 3-Degree-of-Freedom Parallel Mechanism (구형 3자유도 병렬 메커니즘의 기구학 해석 및 구현)

  • Lee, Seok-Hee;Kim, Whee-Kuk;Oh, Se-Min;So, Byung-Rok;Yi, Byung-Ju
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.11 s.176
    • /
    • pp.72-81
    • /
    • 2005
  • A new spherical-type 3-degree-of-freedom parallel mechanism consisting of a two degree-of-freedom parallel module and a serial module is proposed. Two alternative designs for the serial sub-chain are suggested and compared. The first design employs RU joint arrangement for the serial sub chain structure. The second design incorporates a gear chain to drive the distal revolute joint of the serial sub-chain from the base platform of the mechanism. This modification significantly improves kinematic characteristics of the mechanism within its workspace. Firstly, the closed-form solutions of both the forward and the reverse position analysis are derived. Secondly, the first-order kinematic model with respect to three inputs which are located at the base is derived. Thirdly, it is confirmed through simulation that the modified mechanism has much more improved isotropic characteristic throughout the workspace of the mechanism. Lastly, the proposed mechanism is implemented to verify the results from this analysis.

A Study on the Rolling Bearing Failure Mode of Automotive Transaxle(II) -Tapered Roller Bearing for Differential Unit (자동차 변속기용 구름베어링의 파손현상 고찰(II) - 차동장치용 테이퍼 로울러 베어링)

  • Hyeon, Jun-Su;Park, Tae-Jo
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.162-168
    • /
    • 2002
  • This paper shows the failure(wear) phenomena of differential bearings in the transaxle of passenger cars and investigate their characteristics. It was found that the wear mechanism was mild abrasive wear caused by the presence of particles in the gear box. The sides of the outer raceway was more neared than center of it, so it is showed as if the crowning of outer raceway are increased. With close examination of the failed bearing, various countermeasures could be suggested.

  • PDF

Experimental and Parametric Study on the Output Coupled type Continuously Variable Transmission

  • Kim, Yeon-Su;Park, Jae-Min;Park, Sang-Hoon
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.3 no.3
    • /
    • pp.28-36
    • /
    • 2002
  • The continuously variable transmission (CVT) mechanism considered here is the output coupled type which combines the functions of a 2K-H I type differential gear unit and a V-belt type continuously variable unit (CVU). One shaft of the CVU is connected directly to the output shaft and another shaft of it is linked to the differential gear unit. It is shown that some fundamental relations (speed ratios, power flows and efficiencies) for twelve mechanisms previously described are valid by various experimental studies, six of them produce a power circulation and the others produce a power split. Parametric analysis is carried out in relation to the efficiency, speed ratio and power ratios in order to assist in the design of an optimum configuration. Some useful properties associated with power flow modes also are discussed in the output coupled type continuously variable transmission.

A Study on the Rolling Bearing Failure Mode of Automotive Transmission(I) (자동차 변속기용 구름베어링의 파손현상 고찰(I))

  • 현준수;문호근;박태조
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2001.06a
    • /
    • pp.406-411
    • /
    • 2001
  • This paper shows the failure(wear) phenomena of automotive transmission bearings and investigate their characteristics. It was found that the wear mechanism was mainly abrasive wear by the presence of particles in the gear box and the balls was weared more severely than the other tribological contacting parts. The wear of balls alter the bearing contact angle and load ratings, and finally it cause the bearing failure. With close examination of the failed bearing, various countermeasures could be suggested.

  • PDF

DESIGN OF A SINGLE MODE VARIABLE BRIDGE TYPE SPLIT-POWERED CVT WITH AN INNER-SPHERICAL CONTINUOUSLY VARIABLE UNIT

  • Seong, S.H.;Lee, H.W.;Choi, J.H.;Park, N.G.
    • International Journal of Automotive Technology
    • /
    • v.8 no.6
    • /
    • pp.799-806
    • /
    • 2007
  • One method for improving the torque capacity of the CVT is to use a split-powered CVT(SPCVT) to reduce the power transmitted into a continuously variable unit(CVU). A variable bridge SPCVT with two planetary gear units(PGUs), which are composed of a sun gear, a ring gear, and carrier and planetary gears, can minimize the power to the CVU. However, a SPCVT with a conventional CVT should possess a dual mode, which would allow the conventional CVT to be used at high speeds and an additional gear train to be used at low speeds. The inner-spherical CVU(ISCVU) with an inner and outer spherical contact mechanism developed in this study can cover the range from low to high speeds. The rated power and the overall speed ratios were 100 kW and $0.09{\sim}0.36$, respectively. Power efficiency was numerically calculated to be over 90% over the speed ratio range of $0.1{\sim}0.29$. The maximum shear stress at the two contact areas of the rotor pairs, the minimum life and the overall size were estimated to be 700 MPa, 276 kh and $350{\times}350{\times}400mm^3$, respectively. This study shows that an ISCVU and a variable bridge type PGU can realize the SPCVT with a single mode for a vehicle.

Analysis of the Relation Between Machining Accuracy of Internal Gear and Noise in Reduction Gears (감속기 내부 기어의 가공정밀도와 구동간 소음의 연관특성에 관한 연구)

  • Park, Sung-Pil;Kim, Woo-Hyung;Chung, Jin-Tai
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.5
    • /
    • pp.537-543
    • /
    • 2012
  • In this study, we experimentally investigate a noise mechanism related to the machining accuracy of the reducer in the driving state. We fabricate a planetary reducer and four types of gears for use in the planetary reducer. We use signal analysis to determine the noise and vibration of the reducer at different motor speeds; the motor speed is increased from 0 rpm to the maximum speed in a stepwise manner. In addition, we obtain the sound level by using a sound level meter. The machining accuracy of gears is evaluated by public organizations, Korea Testing Laboratory (KTL), on the basis of the Japanese Industrial Standard (JIS). We analyze and compare the results with the noise and vibration of the reducer.

Modeling of the Robot Leg Driven by the Ball Screw Actuator (볼나사 구동기를 갖는 로봇다리의 모델링)

  • 최형식;이호식;박용헌
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.05a
    • /
    • pp.583-586
    • /
    • 2000
  • The conventional actuators with the speed reducer had weakness in supporting the weight of the body and leg itself. To overcome this, a new four bar link mechanism actuated by the ball screw was proposed. The four bar mechanism has higher strength and gear ratio than the conventional actuator to actutate the leg of the biped robot. One leg was designed to have ankle, thigh, and hip joints. The kinematics and dynamics of one leg with four bar link mechanism was analyzed using Euler-Lagrange approach. The dynamics of one leg was expressed in the ball strew frame.

  • PDF

A Development of Disposable Arthroscopic Shaver (디스포저블 관절경 수술기의 개발)

  • Chee Youngioon;Lim Chanyang;Youn Jae-Woong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.10 s.175
    • /
    • pp.218-224
    • /
    • 2005
  • Arthroscopy is a surgical procedure orthopedic surgeons use to visualize, diagnose and treat problems inside a joint. In usual, since the arthroscopic surgery is more accurate and minimally invasive than through 'open' surgery, the surgery of knee, shoulder, and wrist using auto-shaver is increasing in recent. However, repetitive use of arthroscopic-shaver may induce the second infection, hence the disposable arthroscopic-shaver should be developed. In this paper, a unique power transmission mechanism using DC motor, gear trains, and link mechanism is proposed for disposable arthroscopic-shaver and some test results of tissue cutting are introduced.

조속식 감속기(Harmonic Drive)의 설계에 관한 연구

  • 전완주;오박균
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1989.11a
    • /
    • pp.78-85
    • /
    • 1989
  • Conventional theory of gear mechanism can not be applied to analyze the harmonic drive due to specific movement of the tooth. Therefore, external tooth profile can't be manufactured by conventional exclusive tools which have pressure angle of 20$\circ$C. This paper deals with an analysis of kinematics and strength analysis of tooth. Then a theoretical new tooth profile of the flexspline and method of manufacture of external tooth profile are presented.

  • PDF

Nonlinear digital simulation for the analysis of a hydraulic servo system (비선형 디지탈 시뮬레이션에 의한 유압서보 시스템 해석)

  • 이상열;문의준
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1987.10b
    • /
    • pp.346-351
    • /
    • 1987
  • In this study, digital simulation with nonlinear modeling is carried out to analyse the performance of a hydraulic servomotor system developed for the position control of a large inertia. Nonlinear element, such as nonlinear pressure flow relationships of servovalve, valve spool limits, nonlinear friction, and backlash and resilience of gear system are included in the simulation along with the dynamic characteristics of variable delivery pump compensation mechanism. Simulation results are compared with experimental results for both step and sinusoidal inputs. Independent of input magnitude, both results are in good agreement with minor differences in detail.

  • PDF