• Title/Summary/Keyword: Gauge error

Search Result 141, Processing Time 0.027 seconds

The combined effect of dismantling for steam sterilization and aging on the accuracy of spring-style mechanical torque devices

  • Mahshid, Minoo;Saboury, Aboulfazl;Sadr, Seyed Jalil;Fayyaz, Ali;Kadkhodazadeh, Mahdi
    • Journal of Periodontal and Implant Science
    • /
    • v.43 no.5
    • /
    • pp.221-226
    • /
    • 2013
  • Purpose: This study aimed to assess the combined effect of dismantling before sterilization and aging on the accuracy (${\pm}10%$ of the target torque) of spring-style mechanical torque devices (S-S MTDs). Methods: Twenty new S-SMTDs from two different manufacturers (Nobel Biocare and Straumann: 10 of each type) were selected and divided into two groups, namely, case (group A) and control (group B). For sterilization, 100 cycles of autoclaving were performed in 100 sequences. In each sequence, 10 repetitions of peak torque values were registered for aging. To measure and assess the output of each device, a Tohnichi torque gauge was used (P<0.05). Results: Before steam sterilization, all of the tested devices stayed within 10% of their target values. After 100 cycles of steam sterilization and aging with or without dismantling of the devices, the Nobel Biocare devices stayed within 10% of their target torque. In the Straumann devices, despite the significant difference between the peak torque and target torque values, the absolute error values stayed within 10% of their target torque. Conclusion: Within the limitations of this study, there was no significant difference between the mean and absolute value of error between Nobel Biocare and Straumann S-S MTDs.

Accuracy and Satisfaction with IVIC300 (Intravenous infusion controller) (IVIC300(Intravenous infusion controller)의 정확성과 만족도)

  • Park, Jung Hee;Yang, Nam Young;Na, Moon Jun;Go, Young Jin;Kim, Ki Suk;Kim, Young Aue
    • Journal of Korean Public Health Nursing
    • /
    • v.28 no.1
    • /
    • pp.114-126
    • /
    • 2014
  • Purpose: The purpose of this study was to determine the accuracy and satisfaction with IVIC300 (Intravenous infusion controller). Method: The subjects consisted of 90 nurses and 100 patients. Data collected during July 2013 were analyzed using descriptive statistics, t-test, ANOVA, and $X^2$-test (Chi-Square). Result: The error value of IVIC300 was less than that of Dosi-flow. Differences of error values according to variable of fluid infusion (needle's gauge, patient's moving, patient's calls, and nurse's arabitary calls) were not significant. The mean scores for satisfaction with IVIC300 of nurses ($3.67{\pm}.76$), patients ($3.75{\pm}.63$) were above average. Satisfaction with IVIC300 of nurses differed significantly according to age, work unit, and clinical career. Satisfaction with IVIC300 of patients was not significantly different according to general characteristics. Conclusion: These findings indicate that it is proven the accuracy of IVIC300, and is considered individual characteristics in use IVIC300.

State Estimation of Electric Railway Substation using Equality Constraints (등식제약조건을 이용한 전철변전소 상태추정)

  • Kim, Baik;Hong, Hyo-Sik;Yoo, Kwang-Kiun
    • Journal of the Korean Society for Railway
    • /
    • v.13 no.4
    • /
    • pp.419-424
    • /
    • 2010
  • Through the process of state estimation in the electric railway substation, this paper presents a new method for improving the reliability of the measurements corrupted by gauge error. Unlike the case of commercial power systems, it has been difficult to perform the state estimation by using the usual methods in the electric railway substation. At some of the monitoring points in the substation, most often, it is hard to define the measurement functions by use of the states or as we set up a new states set with the change of system topology, some of the measurement functions become part of the states themselves, which leads to poor results. To resolve the problems in the existing method caused by the relations between the states and the measurement functions at the monitoring points, the proposed method in this paper exploits the equality constraints. They can be derived numerously and concisely from the current and the voltage attributes of the Scott transformer and the buses connecting conditions, etc. We have proofed the effectiveness of the proposed method by the test on a standard sample substation.

Analysis of Wave Transmission Characteristics on the TTP Submerged Breakwater Using a Parabolic-Type Linear Wave Deformation Model

  • Jeong, Jin-Hwan;Kim, Jin-Hoon;Lee, Jung-Lyul
    • Journal of Ocean Engineering and Technology
    • /
    • v.35 no.1
    • /
    • pp.82-90
    • /
    • 2021
  • Owing to the advantages of assuring the best views and seawater exchange, submerged breakwaters have been widely installed along the eastern coast of Korea in recent years. It significantly contributes to promoting the advancement of shorelines by partially inhibiting incident wave energy. Observations were carried out by a pressure-type wave gauge in the Bongpo Beach to evaluate the coefficients of wave transmission via a submerged breakwater, and the results obtained were compared with those of existing conventional equations on the transmission coefficient derived from hydraulic experiments. After reviewing the existing equations, we proposed a transmission coefficient equation in terms of an error function. Although it exhibited robust relationships with the crest height and breaking coefficient, deviations from the observed data were evident and considered to be triggered by the difference in the incident wave climate. Therefore, in this study, we conducted a numerical experiment to verify the influence of wave period on the coefficients of wave transmission, in which we adopted a parabolic-type mild-slope equation model. Consequently, the deviation from calculated results appears to practically cover all deviation range in the observed data. The wave period and direction of the incident wave increased, the transmission coefficient decreased, and the wave direction was determined to demonstrate a relatively significant influence on the transmission coefficient. It was inferred that this numerical study is expected to be used practically in evaluating the design achievement of the submerged breakwater, which is adopted as a countermeasure to coastal beach erosion.

Improving SARIMA model for reliable meteorological drought forecasting

  • Jehanzaib, Muhammad;Shah, Sabab Ali;Son, Ho Jun;Kim, Tae-Woong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.141-141
    • /
    • 2022
  • Drought is a global phenomenon that affects almost all landscapes and causes major damages. Due to non-linear nature of contributing factors, drought occurrence and its severity is characterized as stochastic in nature. Early warning of impending drought can aid in the development of drought mitigation strategies and measures. Thus, drought forecasting is crucial in the planning and management of water resource systems. The primary objective of this study is to make improvement is existing drought forecasting techniques. Therefore, we proposed an improved version of Seasonal Autoregressive Integrated Moving Average (SARIMA) model (MD-SARIMA) for reliable drought forecasting with three years lead time. In this study, we selected four watersheds of Han River basin in South Korea to validate the performance of MD-SARIMA model. The meteorological data from 8 rain gauge stations were collected for the period 1973-2016 and converted into watershed scale using Thiessen's polygon method. The Standardized Precipitation Index (SPI) was employed to represent the meteorological drought at seasonal (3-month) time scale. The performance of MD-SARIMA model was compared with existing models such as Seasonal Naive Bayes (SNB) model, Exponential Smoothing (ES) model, Trigonometric seasonality, Box-Cox transformation, ARMA errors, Trend and Seasonal components (TBATS) model, and SARIMA model. The results showed that all the models were able to forecast drought, but the performance of MD-SARIMA was robust then other statistical models with Wilmott Index (WI) = 0.86, Mean Absolute Error (MAE) = 0.66, and Root mean square error (RMSE) = 0.80 for 36 months lead time forecast. The outcomes of this study indicated that the MD-SARIMA model can be utilized for drought forecasting.

  • PDF

Development of IoT-based PM2.5 Measuring Device (사물인터넷 기반 초미세먼지(PM2.5) 측정 장치 개발)

  • Loh, Byoung Gook;Choi, Gi Heung
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.1
    • /
    • pp.21-26
    • /
    • 2017
  • An IoT-based particulate matter (PM2.5) sensing device (PSD) is developed. The PSD consists of a PM2.5 sensor, signal processing circuit, and wi-fi enabled-microprocessor along with temperature and humidity sensors. The PSD estimates PM2.5 density by measuring light scattered by PM2.5. To gauge performance of the PSD, PM2.5 density of open air was measured with the PSD and compared with that of the collocated-government-certified measuring station. Measurements were taken at a sampling frequency of 100 Hz and moving-averaged to remove measurement noise. When compared to the result of the measuring station, average percentile error of PM2.5 density from the PSD is found to be 31%. A correlation coefficient is found to be 0.72 which indicates a strong correlation. Instantaneous variation, however, may far exceed average errors, leading to a conclusion that the PSD is more suitable for estimating average trend of PM2.5 density variations than estimating instantaneous PM2.5 density.

Comparison of the torque stability of Implant Torque Controllers

  • Kim, Dae-Gon;Cho, Lee-Ra;Park, Chan-Jin
    • Journal of Korean Dental Science
    • /
    • v.2 no.1
    • /
    • pp.19-27
    • /
    • 2009
  • Tightening of the screws in implant restorations should be accurate and precise. If applied torque is too low, screw loosening would be occurred. With too high torque, the screw fracture might take place. Various torque generating devices are developed and employed to apply a proper torque. The purpose of this investigation was to determine and compare the accuracy of the torque controllers. In this study, 4 types of torque controllers were used; electronic torque controller, torque limiting device, torque indicating device and contra angle torque driver. Digital torque gauge was employed to measure the de-torque value. Thirty cycles of tightening and loosening were done with each torque controller. All implant torque controllers have shown slight errors and deviations. The torque liming device exhibited the most accurate data. No significant difference was found among the mean de-torque values of the electronic torque controller, torque indicating device and contra angle torque driver. In the limitation of this study, it would be recommended that the implant torque controllers should be checked whether uniformed and precise torque can be generated and a measuring error should be corrected.

  • PDF

Finite Element Analysis of Nonlinear Behavior of a Column Type Sensing Element for Load Cell According to Design Parameters (기둥형 로드셀 감지부의 설계변수에 따른 비선형 거동해석)

  • Lee, Chun-Yeol;Gang, Dae-Im
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.6 s.177
    • /
    • pp.1540-1546
    • /
    • 2000
  • Recently, force measurement systems are commonly used in many industrial fields and the precision of the measurement system is getting more important as the industry needs more precise tools and in struments to make high quality products. However, a high precision force measurement system is hard to make unless we know precisely the causes, quality and quantity of measurement errors in advance. In this work, many possible mechanical causes of measurement errors are reviewed including ratio of length to diameter of sensing part, radius of contact area, radius of bearing part, ratio of material properties and change of boundary conditions. Also, the measurement errors are analyzed by nonlinear finite element method and the nonlinear behavior of the errors are investigated. The results can be used to design force measurement systems and expected to be very useful especially for compact type load cells.

The Comparison of the Accuracy upon the Manual Torque Generating Devices for the Implant (임플란트에 사용되는 수동 토크발생장치의 정확성 비교)

  • Kim, Dong-Hwan;Kim, Han-Su;Oh, Sang-Ho;Chung, Chae-Heon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.3
    • /
    • pp.227-237
    • /
    • 2007
  • Various methods and torque generating devices are developed and employed to apply proper torque clinically. In this study, clinically used torque control devices are measured whether uniformed and precise torque are generated. Digital torque gauge are employed for measurement and torque driver, torque limiting device, torque indicating device are used for torque generating devices. ${\chi}^2$ distribution was formed and One-way ANOVA(Turkey test) was performed to measure torque values generated by each torque generating device. In the results, all companies have been shown slight errors and deviations. This indicates a difficulty of applying precise torque. Therefore, it would be recommended torque generating device should be checked whether uniformed and precise torque can be generated and an error should be corrected.

Vibration Analysis of Bladed Disk using Non-contact Blade Vibration System (비접촉 진동측정 시스템을 이용한 블리스크의 진동분석)

  • Joung, Kyu-Kang;Kim, Myeong-Kuk;Park, Hee-Yong;Chen, Seung-Bae;Park, Noh-Gill
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.132-139
    • /
    • 2008
  • The blade vibration problem of bladed disk is the most critical subject to consider since it directly affects the stable performance of the engine as well as life of the engine. Especially, due to complicated vibration pattern of the bladed disk, more effort was required for vibration analysis and test. The research of measuring the vibration of the bladed disk, using NSMS(Non-intrusive stress measurement) instead of Aeromechanics testing method requiring slip ring or telemetry system with strain gauge, was successful. These testing can report the actual stresses seen on the blades; detect synchronous resonances that are the source of high cycle fatigue (HCF) in blades; measure individual blade mis-tuning and coupled resonances in bladed disks. In order to minimize the error being created due to heat expansion, the tip timing sensor is installed parallel to the blade trailing edge, yielding optimal result. Also, when working on finite element analysis, the whole bladed disk has gone through three-dimensional analysis, evaluating the family mode. The result of the analysis matched well with the test result.

  • PDF