• Title/Summary/Keyword: Gas safety

Search Result 2,931, Processing Time 0.032 seconds

Construction and Development of IoT-based Home Gas Equipment Safety Platform Service (IoT 기반 가정 가스시설 안전 플랫폼 서비스 구축 및 개발)

  • Oh, Jeong-Seok;Baek, Dong-Seok;Park, Tae-Jun;Kim, Jong-Hyeok
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.5
    • /
    • pp.15-23
    • /
    • 2019
  • 42.5% of domestic gas accident due to human factors, and 38% occurred in residential area. Also gas accident caused by deterioration / malfunction increased more than 2 times for last 1 year. In this study we developed IoT based gas safety platform service for Home-gas safety, which secured 99.32% of data transmit accuracy, monitoring and remote control through LPWA bidirectional communication.

Frequence Analysis for City Gas Pipeline (도시가스 배관의 설비손상확률평가)

  • Park Kyo-Shik;Lee Jin-Han;Jo Young-Do;Park Jin-Hee
    • Journal of the Korean Institute of Gas
    • /
    • v.7 no.2 s.19
    • /
    • pp.14-21
    • /
    • 2003
  • Frequency analysis of city gas pipeline was studied and then the method to give frequencies of failure by the third-party digging, corrosion, ground movement, and equipment failure which were known to be the major cause of risk of city gas pipeline. The failure by the third-party digging was analyzed by fault tree analysis and the failure by corrosion was analyzed by applying equation calculating remaining strength with time. The failure by ground movement was evaluated by applying modified model which was induced through weighing factors with basic failure rate model. The failure rate of equipment was calculated with both generic and specific data

  • PDF

Development of a Shut-off Device of LP Gas Regulator for Home Use (가정용 LP가스 조정기 차단안전장치의 개발)

  • Kim Young-Gyu;Kim Pil-Jong;Kwon Boo-Kil;Park Gyo-Shik;Kim Ji-Youn
    • Journal of the Korean Institute of Gas
    • /
    • v.10 no.3 s.32
    • /
    • pp.54-59
    • /
    • 2006
  • A safety device with shut-off function was developed for preventing intentional accidents that might happen by separating of cutting hoses connected to pressure regulators used in residential LP gas facility. For the verification of function and field adaptability, the safety device with shut-off function was tested in the state of joining the device to the regulator and a field test was carried out at home. This study shows that, at the inlet pressure of 0.07-1.56 MPa, the device shuts off the gas within the 5m length of hose regardless of the installation condition of the regulator. The shut-off flow rate increases in the order of perpendicular upward, horizontal and perpendicular downward. From the results of the field tests carried out at home for 5 months, there appears no problem using a gas range or a boiler. If the developed shut-off device is commercialized and distributed in the market the intentional accidents occurred by cutting or separating hoses can be prevented remarkably.

  • PDF

A Safety Management Strategy for Temporary LP-gas Facilities (이동형 LP가스 사용시설의 안전관리 방안)

  • Lee, Duk-Gwon;Lee, Seung-Kuk;Lee, Yeon-Jae;Kim, Hie-Sik
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.6
    • /
    • pp.73-79
    • /
    • 2016
  • A temporary LP-gas facility means outdoor LP-gas facilities in public venues such as boothes or food stalls. As temporary LP-gas facility is not an object of mandatory inspection, it is neccesary to develop an effective strategy of safety management. In this study, the direction of safety management strategy is analyzed through a survey and analysis of risk factor about gas facilities in a booth and stall. Some improved directions are suggested such as the use of pipeline and common gas storage. It is expected that the results of this study could help to improve LP-gas efficiency management.

A Study on Hydrogen Impurity Effect in Anode of Proton Exchange Membrane Fuel Cell on Various Concentration of CO and H2S (고분자전해질 연료전지 연료극의 일산화탄소 및 황화수소 농도에 따른 불순물영향에 관한 연구)

  • LEE, EUN-KYUNG;BAEK, JAE-HOON;LEE, JUNG-WOON;LEE, SEUNG-KUK;LEE, YEON-JAE
    • Journal of Hydrogen and New Energy
    • /
    • v.27 no.6
    • /
    • pp.670-676
    • /
    • 2016
  • Hydrogen town in Republic of Korea was established in 2013. Hydrogen as a byproduct produced by various processes of factories is used in hydrogen town facilities. As cell performance is affected by contaminations in fuel gas, various standards about impurities of fuel have been determined by many countries. This study shows performance degradation of single cell with impurities concentrations. Traces of carbon monoxide (CO) and hydrogen sulfide ($H_2S$)can cause considerable cell performance losses. For comparing the performances by poisoning of CO, acceleration test, I-V curve, constant current are performed. Both the CO and $H_2S$ poisoning rate are a function of their concentration. With the higher concentrations the higher poisoning rates are observed. And, it was confirmed that, oxidation behavior and side reaction generation are not affected. Under the lower $H_2S$ concentration condition, the poisoning rate is much higher than that of CO because of its different adsorption intensity. It can be possible that the result of this study can be used for enacting regulation as a baseline data.

Estimation and Adjustment of Time Point in Manifestation of Gas Safety Project Effects using Sigmoid Functions (시그모이드 함수를 이용한 가스안전사업 효과의 발현시점 추정과 조정)

  • Hyeon Kyo Lim;Geon Yeong Bak
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.1
    • /
    • pp.70-77
    • /
    • 2023
  • Gas has replaced coal or petroleum as primary fuel because of its convenience. However, gas has risk of fire, explosion, or poisoning. To reduce gas-related accidents, many strategic projects have been being carried based on 'Gas Safety Management Basic Plans' on a domestic scale. In spite of those projects, the gas-related accident rate did not decrease over past decades. Thus, this study was conducted to analyze the effectiveness of ongoing projects, and to find out ways to make improvements. Conventional statistical analyses on accident data published by gas-related institutions were not useful to determine meaningful attributes to predict future. Whereas, accident case analyses adopted in the present study discovered differences in the type of people and their unsafe acts for each gas type. Meanwhile, the overall average priority of projects was not high in the aspect of System Safety Precedence. If the current trend is maintained, with sigmoid functions, it can be estimated that mean annual accident rate will decrease by only 2.0% in the next two decades. To improve the current trend, the present study made conclusions as followings: (1) safety projects should be designed with careful consideration of accident traits including gas type, unsafe acts, and persons involved and (2) alternative strategies should include system considerations such as minimum hazard design and safety devices prior to mere education or training. To summarize briefly, the present state related with gas accidents highlights the necessity of a system-based multidisciplinary approach.

Risk Analysis of Explosion in Building by Fuel Gas

  • Jo, Young-Do;Park, Kyo-Shik;Ko, Jae Wook
    • Corrosion Science and Technology
    • /
    • v.3 no.6
    • /
    • pp.257-261
    • /
    • 2004
  • Leaking of fuel gas in a building creates flammable atmosphere and gives rise to explosion. Observations from accidents suggest that some explosions are caused by quantity of gas significantly less than the lower explosion limit amount required to fill the whole confined space, which might be attributed to inhomogeneous mixing of the leaked gas. The minimum amount of leaked gas for explosion is highly dependent on the degree of mixing in the building. This paper proposes a method for estimating minimum amount of flammable gas for explosion assuming Gaussian distribution of flammable gas.