• Title/Summary/Keyword: Gas insulation

Search Result 539, Processing Time 0.035 seconds

Discrimination of insulation defects in a Gas Insulated Switchgear (GIS) by use of a neural network based on a Chaos Analysis of Partial Discharge(CAPD) (카오스이론을 이용한 GIS 내부 절연결함 판별)

  • Lim, Yun-Seok;Lee, Dong-Il;Koo, Ja-Yoon;Kim, Jeong-Tae;Bang, Hang-Kwon
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2223-2225
    • /
    • 2005
  • In this work, experimental investigation has been mainly done. For this purpose, UHF sensor has been designed and fabricated to detect the partial discharges produced from the 10 artificial defects introduced into the real scale 70kV GIS mock-up under the high voltage at the well shielded room. And also, in order to verify the applicability of the proposed method at the site, the proposed CAPD (chaos analysis of partial discharge) is combined with spectral analysis method in order to identify the nature of the above 10 defects. The PD pattern recognition of each defect has been fulfilled by applying self developed artificial neural network soft ware. The result shows that the recognition rate is reached to be 80% by newly proposed method while the traditional PRPD analysis method leads us to obtain 41%. In consequence, it can be pointed out that the proposed method seems likely to be applicable to the real GIS at the site.

  • PDF

Analysis of Furanic Compounds Dissolved in Transformer Oil (변압기에 용존된 Furan계 물질 분석)

  • Kim, Jae-Hoon;Lee, Byung-Sung;Lee, Sei-Hyun;Koo, Kyung-Wan;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.1909-1911
    • /
    • 2005
  • The electrical and chemical characteristics in transformer insulations are changed due to thermal stress. In the chemical property, as the Kraft paper ages, the cellulose polymer chains breakdown into shorter lengths with a corresponding decrease in both tensile strength and degree of polymerization(DP). Furthermore, cellulous chains breakdown is accompanied by an increase in the content of various furanic compounds within the dielectric liquid. It is known that furanic components in transformer oil come only from the decomposition of insulating paper rather than from the oil itself. Therefore the analysis of furan products provides a complementary technique to dissolved gas analysis for monitoring transformers when we evaluate the aging of insulating paper by the total concentration of carbon monoxide and carbon dioxide dissolved in oil only. In this paper the accelerated aging process of oil--paper samples have been investigated at a temperature up to $140^{\circ}C$ for 500 hours. The oil-paper insulation samples have been measured at intervals of 100 hours. For analysis we used high performance liquid chromatography(HPLC) in accordance with IEC 61198 method.

  • PDF

Numerical Analysis of Surface Discharge due to Particles Attached to the GIS spacer (GIS 스페이서에 파티클 부착시 연면방전과 전계해석)

  • Jang, D.G.;Lee, J.H.;Kwak, H.R.;Park, H.Y.;Kim, Y.C.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1788-1790
    • /
    • 2003
  • GIS is a typical power equipment with higher reliability. It is compact and safe because all the energized parts are enclosed by a sealed cylindrical tank which is filled with $SF_6$. Generally gas insulated power equipments like GIS are designed to have sufficient electrical strength to prevent partial discharges under normal operating condition. Despite of the careful processes in manufacturing, transporting and assembling, voids or particles can be created, resulting in partial discharges at electrically weak points. The key factors causing partial discharges in GIS are; particles, voids in solid insulation, protrusions, poor contact of metal components, etc. The particle can be attached on; spacers, electrodes, internal wall of the GIS tank. It also moves in GIS freely. Most of partial discharges are likely to occur when particles are attached to spacers. In this paper, the electrical characteristics of a surface discharge were investigated under various conditions by using simulation program of FEMLAB.

  • PDF

A Study on the Electrical Propertis of Optical Potential Transformer for GIS (GIS용 광PT의 전기적 특성에 관한 연구)

  • Lee, Su-Woong;Lee, Sung-Gap;Park, Sang-Man;Wu, Hyeong-Gwan;Won, Woo-Sik;Ahn, Byeong-Rip
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1273-1274
    • /
    • 2007
  • In this paper, a Optical Voltage Transformer has been designed and fabricated to improve temperature stability caused by materials properties and insulation in measuring system, using single crystal $Bi_{12}SiO_{20}$ as Pockels effect cells for Gas Insulated Switchgear[GIS] System. LD[wavelength: 850nm] was used as optical source, InGaAs as optical detector to measure optical power, Polarizing Beam Splitter as Polarizer and Analyzer, and Multi-mode Optical-fiber[62.5/$125{\mu}m$] as Light transmission line. OPT was assembled in order to pockels effect, and adopted direct electric field type. The linearity of OPT maintains variation for applied voltage range from 100V - 3000V during the test of electric property, As the temperature was changed from $25^{\circ}C$ to $60^{\circ}C$. the result of this study shows that characteristics of OPT are good, and it can be reflected for practical optical sensors in GIS system.

  • PDF

Influence of Deposition Parameters on Film Hardness for Newly Synthesized BON Thin Film by Low Frequency R.F. PEMOCVD

  • G.C. Chen;J.-H. Boo;Kim, Y.J.;J.G. Han
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2001.06a
    • /
    • pp.73-73
    • /
    • 2001
  • Boron-containing materials have several excellent properties, such as superlnardness, insulation and non-Rinear optical property. Recently, oxynitride compounds, such as Si(ON), Ti(ON), became the promising materials applied in diffusion barrier layer and solar cell. With the expectation of obtaining the hybrid property, we have firstly grown the BON thin film by radio frequency (R.F.) plasma enhanced metalorganic chemical vapm deposition (PEMOCVD) with 100 kHz frequency and trimethyl borate precursor. The plasma source gases used in this study were Ar and $H_2$, and two kinds of nhmgen source gases, $N_2$ and <$NH_3$, were also employed. The as-grown films were characterized by XPS, IR, SEM and Knoop microlhardness tester. The relationship between the films hardness and the growth rate indicated that the hardness of the film was dependent on several factors such as nitrogen source gas, substrate temperature and film thickness due to the variation of the composition and the structure of the film. Both nitrogen and carbon content could raise the film hardness, on which nitrogen content did stronger effect than carbon. The smooth morphology and continuous structure was benefit of obtaining high hardness. The maximum hardness of BON film was about 10 GPa.

  • PDF

SYSTEM MODELLING OF ON-SITE ENERGY CONSUMPTION PROFILE IN CONSTRUCTION SITES AND A CASE STUDY OF EARTH MOVING

  • Kyoo-Jin Yi
    • International conference on construction engineering and project management
    • /
    • 2013.01a
    • /
    • pp.287-293
    • /
    • 2013
  • The annual expenditure on diesel oil and heavy oil in the construction sector is the second largest among all industrial sectors. According to the greenhouse reduction scheme of Korean Government, construction sector targeted 7.1% reduction by 2020. Although this target is not higher than other industrial sectors, it is not easy to achieve the reduction target without radical advance in technology, which cannot be expected to happen soon, considering the conservative characteristics of construction industry. Most researches on environmental issues focus on the issues related to energy saving matters during material production stage or maintenance stage, such as heating and insulation, and few deal with the issues directly related to the energy use in the construction sites. This research regards the operation of equipment for the on-site construction processes as a system and attempts to model the energy use processes related to the activities in construction sites, and provides simulation results of earth excavation and hauling processes. The result of this research is expected to aid construction planners estimating the time-based patterns of energy use and assessing greenhouse gas emission and to help selecting more energy efficient alternatives at the planning stage.

  • PDF

Detection with a SWNT Gas Sensor and Diffusion of SF6 Decomposition Products by Corona Discharges (탄소나노튜브 가스센서의 SF6 분해생성물 검출 및 확산현상에 관한 연구)

  • Lee, J.C.;Jung, S.H.;Baik, S.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.1
    • /
    • pp.66-72
    • /
    • 2009
  • The detection methods are required to monitor and diagnose the abnormality on the insulation condition inside a gas-insulated switchgear (GIS). Due to a good sensitivity to the products decomposed by partial discharges (PDs) in $SF_6$ gas, the development of a SWNT gas sensor is actively in progress. However, a few numerical studies on the diffusion mechanism of the $SF_6$ decomposition products by PD have been reported. In this study, we modeled $SF_6$ decomposition process in a chamber by calculating temperature, pressure and concentration of the decomposition products by using a commercial CFD program in conjunction with experimental data. It was assumed that the mass production rate and the generation temperature of the decomposition products were $5.04{\times}10^{-10}$ [g/s] and over 773 K respectively. To calculate the concentration equation, the Schmidt number was specified to get the diffusion coefficient functioned by viscosity and density of $SF_6$ gas instead rather than setting it directly. The results showed that the drive potential is governed mainly by the gradient of the decomposition concentration. A lower concentration of the decomposition products was observed as the sensors were placed more away from the discharge region. Also, the concentration increased by increasing the discharge time. By installing multiple sensors the location of PD is expected to be identified by monitoring the response time of the sensors, and the information should be very useful for the diagnosis and maintenance of GIS.

A Study on the Efficiency Estimation of Halogen free Fire Resistance Cable (저독성 내화전선 케이블의 성능평가에 관한 연구)

  • 윤헌주;홍진웅;유동일;윤재선;곽동일
    • Fire Science and Engineering
    • /
    • v.16 no.1
    • /
    • pp.18-23
    • /
    • 2002
  • Efficiency estimation of toxicity free resistance cable experiments were conducts to understand toxicity free fire ersistance polyolefin insulation material and smoke density characteristic and combustion gas corrosion analysis. A main cause of fire-growth and generating toxic gas when it burns, should be dealt with great care in life safety design. Similar patterned fire incidents such as, Inchon Live-Hof Pub Restaurant as, Sea-land Children Resort have proven that serious loss of lives were caused by hazardous gas generated fire resistance cable materials. In this paper, Referenced documents were ASTM E662 standard test method for specific Ds genalated by solid materials. The furnace control system shall maintain the required irradiance level under steady-state condition with the chamber door closed of 2.5$\pm40.04〔w/$\textrm{cm}^2$〕for 20 min. According to the results of the smoke density analysis of NFR-8 and FR-PVC the highest decomposition flaming smoke density range of NFR-8 and FR-PVC were 25.2 to 37.5 and 51.1 respectively. Nonflaming smoke density range of NFR-8 and FR-PVC were 100.4 to 112.2 and 126.5 to 398.8. Also, the fire gases was occurred carbon monoxide and decomposition than in polyolefin due to incomplete combustion of PVC which has high content of carbon in chemical compound.

Experimental Study on the Toxicity Characteristics of Non-Class 1E Cables according to Accelerated Deterioration (가속열화에 따른 비안전등급 케이블의 독성특성에 관한 실험적 연구)

  • Jang, Eun-Hui;Kim, Min-Ho;Lee, Min Chul;Lee, Sang-Kyu;Moon, Young-Seob
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.105-113
    • /
    • 2019
  • This study investigates the toxicity characteristics of two Non-Class 1E Cables (For security reasons, we refer to company A and company B) used in nuclear power plants according to the accelerated deterioration period. In accordance with NES 713 test equipment and standards, tests were carried out on non-aged cables and the cables subjected to 20- and 40-year-accelerated-deterioration; each of the cables was further classified into sheath and insulation. The test results showed that the toxicity indices of 20- and 40-year-accelerated-aged cables were higher than those for the non-aged cables, and 20-year-aged cables of both A and B companies showed the highest toxicity indices. This is attributed to the extensive emissions of carbon monoxide and halide gases such as hydrogen chloride and hydrogen bromide. Furthermore, to analyze the toxicity indices of sheath and insulation in detail, the US Department of Defense standard (MIL-DTL) was applied to determine whether the Toxicity index (T.I.) allowance was exceeded, and the results showed that the insulating materials emitted considerably more than the allowable limit.

Partial Discharge Detection of High Voltage Switchgear Using a Ultra High Frequency Sensor

  • Shin, Jong-Yeol;Lee, Young-Sang;Hong, Jin-Woong
    • Transactions on Electrical and Electronic Materials
    • /
    • v.14 no.4
    • /
    • pp.211-215
    • /
    • 2013
  • Partial discharge diagnosis techniques using ultra high frequencies do not affect load movement, because there is no interruption of power. Consequently, these techniques are popular among the prevention diagnosis methods. For the first time, this measurement technique has been applied to the GIS, and has been tested by applying an extra high voltage switchboard. This particular technique makes it easy to measure in the live state, and is not affected by the noise generated by analyzing the causes of faults ? thereby making risk analysis possible. It is reported that the analysis data and the evaluation of the risk level are improved, especially for poor location, and that the measurement of Ultra high frequency (UHF) partial discharge of the real live wire in industrial switchgear is spectacular. Partial discharge diagnosis techniques by using the Ultra High Frequency sensor have been recently highlighted, and it is verified by applying them to the GIS. This has become one of the new and various power equipment techniques. Diagnosis using a UHF sensor is easy to measure, and waveform analysis is already standardized, due to numerous past case experiments. This technique is currently active in research and development, and commercialization is becoming a reality. Another aspect of this technique is that it can determine the occurrences and types of partial discharge, by the application diagnosis for live wire of ultra high voltage switchgear. Measured data by using the UHF partial discharge techniques for ultra high voltage switchgear was obtained from 200 places in Gumi, Yeosu, Taiwan and China's semiconductor plants, and also the partial discharge signals at 15 other places were found. It was confirmed that the partial discharge signal was destroyed by improving the work of junction bolt tightening check, and the cable head reinforcement insulation at 8 places with a possibility for preventing the interruption of service. Also, it was confirmed that the UHF partial discharge measurement techniques are also a prevention diagnosis method in actual industrial sites. The measured field data and the usage of the research for risk assessment techniques of the live wire status of power equipment make a valuable database for future improvements.