• Title/Summary/Keyword: Gas extinguishing system

Search Result 50, Processing Time 0.028 seconds

Arc-Extinguishing Characteristics of A Rotary-Arc Gas Circuit Breaker (자력소호 가스차단부의 소호특성)

  • Shin, Young-June;Park, Kyong-Yop;Song, Ki-Dong
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1593-1598
    • /
    • 1994
  • Recently rotary-arc, thermal expansion and their composite interrupters are widely used in the distribution power system because they have lots of advantages in making the larger interrupting capacity, the smaller size, the lighter weight and the less surge. A model interrupter of rotary-arc type, which has constant stroke and thermal expansion volume, was studied by varying the design parameters, i.e. the number of turns of the driving coil, the inner diameter of the moving contact, the gas pressure and the shape of the fixed contact for this project. Short cicuit current interrupting tests were conducted to the model interrupters by varying the requirements from 42% to 175% of the test voltage, interrupting current and transient recovery voltage for the test duty No.4 of 7.2kV 12.5kA single phase test. The pressure rise, minimum and maximum arcing times were analyzed for each model interrupter. All types of model interrupters showed good interrupting performances and sufficient design margins for the ratings.

  • PDF

Comparative Analysis of PD Characteristics Under SF6, g3 and Dry Air Insulation (SF6, g3 및 Dry Air 절연에서 PD 특성 비교 분석)

  • Shin, Han-sin;Kim, Nam-Hoon;Kim, Sung-Wook;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.33 no.6
    • /
    • pp.490-494
    • /
    • 2020
  • Sulphur hexafluoride (SF6) is mostly used as a current-insulating medium in gas-insulated switchgears (GIS), owing to its excellent dielectric strength and arc-extinguishing performance. The global warming potential (GWP) of SF6, however, is 23,900 times that of CO2, and its life time in the atmosphere is 3,200 years. For these reasons, new eco-friendly gases to replace SF6 are required. In this study, the partial discharge (PD) characteristics of green gas for grid (g3) and dry air (N2/O2) were analyzed to compare with those of SF6. A PD electrode system was designed to simulate the protrusion defect in GISs and fabricated for experimentation. To compare the PD characteristics of each gas, the discharge inception voltage (DIV), discharge extinction voltage (DEV), discharge magnitude, discharge pulse number, and phase pattern were analyzed. Results from this study are expected to provide fundamental materials for the design of eco-friendly GISs.

Sprinkler Layout Optimization Based on Fire Simulation and Mathematical Programming including Installation and Damage Costs (설치비와 피해액의 정형화를 통한 화재 시뮬레이션 및 수리계획법에 기반을 한 스프링클러의 배치 최적화)

  • Lee, Ki-Jun;Shin, Young-Sup T.;Hong, Gi-Hoon;Joo, Ki-Don;Shin, Dong-Il;Kim, Tae-Ok
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.2
    • /
    • pp.52-59
    • /
    • 2012
  • The sprinkler system is regarded as the most effective fire extinguishing system. In this study, we proposed a sprinkler layout optimization framework based on fire simulation and mathematical programming. As a case study, the target space in the form of ordinary residence was set up with the size of $5.2m(L){\times}5.4m(W){\times}2.4m(H)$, and we constructed the fire scenario that polyurethane couch was ignited through carelessness. And we simulated and analyzed fire speed, temperature change and heat release rate according to the type and number of sprinklers installed. Through the formulation of installation and damage costs depending on sprinklers, the sprinkler layout showing optimal performance was resulted from mathematical programming.

A Study on the Application of Bushings Fire Prevent Structure to Prevent Fire Spread of Transformer (변압기의 화재확산 방지를 위한 부싱 방화구조체 적용에 관한 연구)

  • Kim, Do-Hyun;Cho, Nam-Wook;Yoon, Choung-Ho;Park, Pil-Yong;Park, Keun-Sung
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.53-62
    • /
    • 2017
  • Electric power which is the energy source of economy and industries requires long distance transportation due to regional difference between its production and consumption, and it is supplied through the multi-loop transmission and distribution system. Prior to its actual use, electric power flows through several transformations by voltage transformers in substations depending on the characteristics of each usage, and a transformer has the structure consisting of the main body, winding wire, insulating oil and bushings. A transformer fire that breaks out in substations entails the primary damage that interrupts the power supply to houses and commercial facilities and causes various safety accidents as well as the secondary economic losses. It is considered that causes of such fire include the leak of insulating oil resulting from the destruction of bottom part of bushings, and the chain reaction of fire due to insulating oil that reaches its ignition point within 1 second. The smoke detector and automatic fire extinguishing system are established in order to minimize fire damage, but a difficulty in securing golden time for extinguishing fire due to delay in the operation of detector and release of gas from the extinguishing system has become a problem. Accordingly, this study was carried out according to needs of active mechanism to prevent the spread of fire and block the leak of insulating oil, in accordance with the importance of securing golden time in extinguishing a fire in its early stage. A bushings fireproof structure was developed by applying the high temperature shape retention materials, which are expanded by flame, and mechanical flame cutoff devices. The bushings fireproof structure was installed on the transformer model produced by applying the actual standards of bushings and flange, and the full scale fire test was carried out. It was confirmed that the bushings fireproof structure operated at accurate position and height within 3 seconds from the flame initiation. It is considered that it could block the spread of flame effectively in the event of actual transformer fire.

Suggestion of the Attached Piping Material Rate for the Mechanical Fire Protection Facilities in Office Buildings (업무용 건축물의 기계소방시설 배관 부속자재 요율 제시)

  • Park, Lyool;Park, Kyung-Soon;Yoon, Hang-Mook
    • Journal of the Regional Association of Architectural Institute of Korea
    • /
    • v.20 no.6
    • /
    • pp.1-8
    • /
    • 2018
  • In generally, the estimation work regarding building mechanical service system in comparison with other architectural estimations is time-consuming, and the process is continuously getting more difficult because of the increased usage of the attached piping materials such as fittings and supports in addition to their complicated construction processes. In order to improve this problem, the Korean authority provides a simple method to estimate the attached material rate regarding the main piping material, which is the most time-consuming work in the architectural mechanical estimation. However, to be an applicable method on construction site, a proper conversion rate of the attached piping material is still required for the proposed method regarding building usage and working types. Therefore, the purpose of this research is the suggestion of the material and labor cost rate of the attached piping materials such as the fittings and supports by work types and fitting methods of indoor fire, sprinkler, and extinguishing gas piping work of mechanical fire protection facilities in office buildings that have been designed after 2010.

The development of the escape light control system (유도등 제어시스템의 개발)

  • Kim, Dong-Ook;Mun, Hyun-Wook;Lee, Ki-Yeon;Kim, Dong-Woo;Gil, Hyung-Jun;Kim, Hyang-Kon;Chung, Young-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.6
    • /
    • pp.52-58
    • /
    • 2009
  • When a fire breaks out, it is frequent that large sized miserable death is happened by seriousness of poisonous gas and peculiarity of space because the building construction is recently more complex and diverse. So early countermeasure in preparation for evacuation escape linked directly with a loss of lives is pressing. Because escape light that mark fixing one-way of existing way is not efficiently extricated refugees from dangers when a fire breaks out, construction of system that can extricate refugees from dangers and suppress early a fire by grasping correctly fire point is required urgently. When a fire breaks out, all escape lights connected with fire sensor and reception group which have ill aiming in these point will lead people to safe emergency entrance of opposite direction of place that a fire is broken out after being calculated the direction and speed of flame and smoke. There is the purpose of my research in development of artificial intelligent directional escape light that can mark direction to most suitable pull-out and assist in early extinguishing a fire.

The Proposal of Installations Standards for Commercial Kitchen Automatic Fire System (상업용 주방자동소화장치 도입과 설치기준 제안)

  • Lee, Changwoo;Kang, Dowoo;Oh, Seungju;Ham, Eungu;Cho, Yongsun
    • Journal of the Society of Disaster Information
    • /
    • v.12 no.1
    • /
    • pp.89-97
    • /
    • 2016
  • According to the statistics released by Ministry of Public Safety and Security, the number of restaurant fires in Korea reached around 2,400 and 169 damages of human life and damages to property was approximately over $8.8 billion for recent 3 years. It could be desirable having automatic commercial fire-extinguishing equipment at commercial facilities excluding housing facilities for the safety, applying at the place first where it has been more risky and expected fire can be occurred relatively because economical burden can be accelerated. In order to do this, adjust its level to meet the same level of the kitchen for 'Specific Target for Fire Fighting' that "gas leak alarm" has be equipped relevant regulations and it is considered and reasonable to expand the limit of application gradually.

A Study for Examples of Fire including with Combustible Substance and electrical overload in Automotive Inside Room (자동차 실내 인화성물질과 전기과부하에 의한 화재관련 사례 연구)

  • Han, Jae Oh;Ham, Sung Hoon;Lim, Ha Young;Lee, Il Kwon
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.3
    • /
    • pp.38-43
    • /
    • 2014
  • This paper is to analyze and study the failure examples of fire by inflammables and electric contact faulty in interior of vehicle. The first example, the driver used to air freshener that remove the air conditioner bad smell. He get out of a car. And then, he put it on the crash pad. Before long, a fire breaks out because of explosion solar radiation. The second example, the driver used in room of a car. It certified the fire by disconnection phenomenon happened the electric overload. The third example, the driver install the heat rays to warm his body, In the initial stages, it didn't seek the dangerous of fire during using a car to 5,000km. This heat rays become to down durability so that produced the electric overload in an instant. The fourth example, after the man smoked the cigarette on riding with rear seat, he put it on seat in vehicle no extinguishing the burning cigarette. It knew the fact that burnt to ashes a car by on well combustible paper. Thus, the driver must consider a countermeasure for minimize the fire production when he use the inflammable and install adding electric system.

A Numerical Study on the Extinguishing Effects of CO2 in Counterflow Diffusion Flames with the Concept of Local Application System (국소방출방식 개념의 대향류 확산화염에서 CO2 소화효과에 관한 수치해석 연구)

  • Mun, Sun-Yeo;Park, Chung-Hwa;Hwang, Cheol-Hong;Oh, Chang-Bo
    • Fire Science and Engineering
    • /
    • v.26 no.4
    • /
    • pp.55-62
    • /
    • 2012
  • The suppression mechanisms of carbon dioxide ($CO_2$) as a representative fire suppression agent were revisited using a counterflow diffusion flame which could be applied the concept of a local application system. To end this, the low strain rate $CH_4$/air counterflow diffusions with $CO_2$ addition in either fuel or oxidizer stream were examined numerically using detailed-kinetic chemistry. Radiative heat loss due to radiating gas species including $CO_2$ added was considered by the optically thin model (OTM). As a result, the critical $CO_2$ volume fractions in the oxidizer stream required to extinguish the flame were in good agreement with the experimental data reported in the literature, while somewhat under-prediction was observed with $CO_2$ added in the fuel stream. The surrogate agents were adopted to estimate the quantitative contribution with changing in global strain rate ($a_g$) on the flame extinguishment among pure dilution effect, thermal effects including radiation heat loss and chemical effect due to the $CO_2$ fire suppression agent.

The study for musculoskeletal symptoms and job stress in firemen (소방관의 근골격계 증상과 직무 스트레스에 관한 연구)

  • Kim, Jung Man;Suh, Byung Seong;Jung, Kap Yeol;Kim, Dong Il;Kim, Won Sool;Cho, Han Seok;Kim, Jin Wook;Kwon, Jae;Yoon, Dong Young;Kim, Jung Il;Roh, Young-Man
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.17 no.2
    • /
    • pp.111-119
    • /
    • 2007
  • Firemen are directly exposed to various harmful chemicals, physical factors and mental stress during rescue and fire-fighting. In fire extinguishing, unstable posture, poisonous gas, dust, high temperature and heavy equipments are possible hazardous factors. The alertness for emergency, shift work, job strain and stress are also possibly hazardous. Therefore, this study aimed to investigate the prevalence of musculo-skeletal symptoms and job stress and to determine risk factors in firemen. This study was carried out in a group of 226 firemen in Busan City, Korea. Standardized Nordic Questionnaire was used to investigate the prevalence of musculo-skeletal symptoms and Psycho-social Well-being Index (abbreviated PWI) was used to investigate the prevalence of job stress. General and occupational characteristics were included education, marital status, alcohol and smoking history, working duration, and work shift system. Body mass index (BMI) scores were calculated by physical examination including height and weight. Concerning musculo-skeletal complaints, the commonest site was neck, and shoulder, lower back, upper back were the next. Complaint site above one area of body was about 80%. From multiple logistic regression analysis, working duration was significant variable in musculo-skeletal symptoms. Odds ratio were 15.4 in working duration. About 16.8% was high risk stress group. From multiple logistic regression analysis, shift work and alcohol drinking were significant variables in PWI scores. Odds ratios were 2.25 in shift work. Accordingly, interventions are needed for health promotion of long term and shift worker.