• Title/Summary/Keyword: Gas detection

Search Result 1,196, Processing Time 0.028 seconds

System of gas sensor for conbinating wire and wireless using Internet of Things (IOT기술을 이용한 유무선 통합 가스검출 시스템 구현)

  • Bang, Yong-Ki;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.4
    • /
    • pp.297-304
    • /
    • 2015
  • This study concerns the integrated gas sensor system of wire and wireless communication by using IoT(Internet of Things) technology. First, communication part is that it delivers the detection information, which transferred by wire or wireless communication and required control procedure based on a wireless module that receives the gas leakage information from wired or wireless detector, to administrator or user's terminal. Second, receiver part is that it shows the location and information, which received from the wired detector formed by a detecting sensor's node as linking with the communication part, and transfers these to the communication part. Third, wireless detector formed as a communication module of a detecting sensor node is that it detects gas leakage and transfers the information through wireless as a packet.Fourth, wired detector communicated with the receiver part and formed as a communication module of a detecting sensor node is that it detects gas leakage, transfers and shows the information as a packet. Fifth, administrator's terminal is that it receives gas leakage information by the communication part, transfers the signal by remote-control, and shut off a gas valve as responding the information. Sixth, database is that it is connected with the communication part; it sets and stores the default values for detecting smoke, CO., and temperature; it transfers this information to the communication part or sends a gas detecting signal to user's terminal. Seventh, user's terminal is that it receives each location's default value which stored and set at the database; it manages emergency situation as shutting off a gas valve through remote control by corresponding each location's gas leakage information, which transferred from the detector to the communication part by wireless.It is possible to process a high quality data regarding flammable or toxic gas by transferring the data, which measured by a sensor module of detector, to the communication part through wire and wireless. And, it allows a user to find the location by a smart phone where gas leaks. Eventually, it minimizes human life or property loss by having stability on gas leakage as well as corresponding each location's information quickly.

236U accelerator mass spectrometry with a time-of-flight and energy detection system

  • Li Zheng;Hiroyuki Matsuzaki;Takeyasu Yamagata
    • Nuclear Engineering and Technology
    • /
    • v.54 no.12
    • /
    • pp.4636-4643
    • /
    • 2022
  • A time-of-flight and energy (TOF-E) detection system for the measurement of 236U accelerator mass spectrometry (AMS) has been developed to improve the 236U/238U sensitivity at Micro Analysis Laboratory, Tandem accelerator (MALT), The University of Tokyo. With observing TOF distribution of 235U, 236U and 238U, this TOF-E detection system has clearly separated 236U from the interference of 235U and 238U when measuring three kinds of uranium standards. In addition, we have developed a novel method combining kernel-based density estimation method and multi-Gaussian fitting method to estimate the 236U/238U sensitivity of the TOF-E detection system. Using this new estimation method, 3.4 × 10-12 of 236U/238U sensitivity and 1.9 ns of time resolution are obtained. 236U/238U sensitivity of TOF-E detection system has improved two orders of magnitude better than that of previous gas ionization chamber. Moreover, unknown species other than uranium isotopes were also observed in the measurement of a surface soil sample, which has demonstrated that TOF-E detection system has a higher sensitivity in particle identification. With its high sensibility in mass determination, this TOF-E detection system could also be used in other heavy isotope AMS.

Effects of Gas Background Temperature Difference(Emissivity) on OGI(Optical Gas Image) Clarity (가스의 배경 온도 차이(방사율)가 OGI(Optical Gas Image)의 선명도에 미치는 영향)

  • Park, Su-Ri;Han, Sang-Wook;Kim, Byung-Jick;Hong, Cheol-Jae
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.5
    • /
    • pp.1-8
    • /
    • 2017
  • Currently gas safety management in the industrial field has been done by LDAR as contact method or methane leak detector as non-contact method. But LDAR method requires a lot of man-power and methane leak detector have the limitation of methane only. Therefore the Research on the OGI(optical gas image) has big attention by industry. This research was undertaken to see the effect of background temperature difference of gas cloud on the clarity of OGI. The background temperature control panel was constructed to cool down the background temperature. OGI was taken at the various methane gas ejection rate and the designed temperature difference. The experimental results showed that the OGI(when the temperature difference is $-6^{\circ}C$) is more clear thane the OGI(when the temperature difference is zero). To quantify the clarity difference, MATLAB's RGB analysis method was employed. The RGB value of the OGI at ${\Delta}T-6^{\circ}C$ was 20% lower than the OGI at ${\Delta}T0^{\circ}C$. The clarity difference by T difference can be explained by the total radiation law. When the background temperature of the gas is lower than the air temperature, the radiation energy coming into the OGI lens is increasing. As the energy is increasing, the OGI image becomes clear.

The Realization on GAS Sensor Module for Inteligent Wireless Communication (지능형 무선통신용 가스 센서 모듈 구현)

  • Kim, Hyo-Chan;Weon, Young-Su;Cho, Hyung-Rae
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.11 no.6
    • /
    • pp.123-132
    • /
    • 2012
  • Gas sensors has been used very differently that depending on following purposes; Automotive (exhaust gas, fuel mixture gas, oxygen, particulates), agriculture / food industry (fresh, stored, CO2, humidity, NH3, nitrogen oxide gas, organic gas, toxic gas emitted from pesticides and insecticides), industrial / medical (chemical gas, hydrogen, oxygen and toxic gases), military (chemical weapon), environmental measurements (CO and other air pollution consisting of sulfur and nitrogen gas), residential (LNG, LPG, butane, indoor air, humidity). The types of industrial toxic substances are known about 700 species and many of these exist in gaseous form under normal conditions. he multi-gas detection sensors will be developed for casualties that detect the most important and find easy three kinds of gases in marine plant; carbon dioxide(CO2), carbon(CO), ammonia(NH3). Package block consists of gas sensing device minor ingredient, rf front end, zigbee chip. Develope interworking technology between the sensor and zigbee chip inside a package. Conduct a performance test through test jig about prototype zigbee sensor module with rf output power and unwanted emission test. This research task available early address when poisonous gas leaked from large industrial site and contribution for workers' safety at the enclosed space.

Formation Mechanism Analysis and Detection of Charged Particles in an Aero-engine Gas Path

  • Wen, Zhenhua;Hou, Junxing;Jiang, ZhiQiang
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.16 no.2
    • /
    • pp.247-253
    • /
    • 2015
  • The components of an aero-engine gas path cannot be monitored in a timely way due to a lack of real-time monitoring technologies. As an attempt to address this problem, we have conducted research on a condition monitoring technology based on the charging characteristics of particles in an aero-engine gas path, and emphatically analyze the formation of particles in an aero-engine gas path, the charging mechanism of carbon particles and the factors that influence the charge quantity and polarity. The verification experiments are performed on the simulated experiment platform and a turbo-shaft engine test bench. The results show the carbon particles' carry charge, and an obvious change in the total electrostatic charge level in the aero-engine gas path due to the increased carbon particles produced by burning or abnormal metal particles; the charge number is related to the size of particles, and the bigger carbon particles carry a negative charge and metal particles carry a positive charge; the change in engine power can lead to an obvious change in the level of electrostatic charge in the gas path, and the change in electrostatic charge results from the extra carbon particles formed in the rich-oil burning process. The research provides a reference for establishing the baseline of electrostatic charge while the engine runs on different power. The study also demonstrates the validity of the electrostatic monitoring technology and establishes a base for developing the application of electrostatic monitoring technology in aero-engines.

The Study on Eddy Current Characteristic for Surface Defect of Gas Turbine Rotor Material (가스터빈 로터 재질에 따른 표면결함 와전류 특성연구)

  • Ahn, Y.S.;Gil, D.S.;Park, S.G.
    • Journal of Power System Engineering
    • /
    • v.14 no.4
    • /
    • pp.63-67
    • /
    • 2010
  • This paper introduces the eddy current signal characteristic of magnetic and non-magnetic gas turbine rotor. In the past, Magnetic particle inspection method was used in magnetic material for qualitative defect evaluation and the ultrasonic test method was used for quantitative evaluation. Nowadays, eddy current method is used in magnetic gas turbine rotor inspection due to advanced sensor design technology. We are studying on the magnetic gas turbine rotor by using eddy current method. We prepared diverse depth specimens made by magnetic and non-magnetic materials. We select optimum frequency according to material standard penetration data and experiment results. We got the signal on magnetic and non-magnetic material about 0.2 mm, 05 mm, 1.0 mm, 1.5 mm 2.0 mm and 2.5 mm depth defects and compare the signal amplitude and signal trend according to defect depth and frequency. The results show that signal amplitudes of magnetic are bigger than non-magnetic material and the trends are similar on every defect depth and frequency. The detection and resolution capabilities of eddy current are more effective in magnetic material than in non-magnetic materials. So, the eddy current method is effective inspection method on magnetic gas turbine rotor. And it has the merits of time saving and simple procedure by elimination of the ultrasonic inspection in traditional inspection method.

Preparation of $SnO_2$ Semiconducting Gas Sensor by Wet Process (습식방법에 의한 $SnO_2$ 반도체 가스센사 제조)

  • 전병식;김홍대;최병현;최성근
    • Journal of the Korean Ceramic Society
    • /
    • v.23 no.3
    • /
    • pp.53-61
    • /
    • 1986
  • A gas sensor which has been made by wet process had fabricated by coating each of the mixture on alumina tube and firing at 85$0^{\circ}C$ for 3hrs. A gas concentration such $H_2$, CO, $C_3H_8$, $C_2H_2$ and $CH_4$ vs its detection voltage characteristics has been in-vestigated on $SnO_2-In_2O_3-MgO$ system doped with PdO, $La_2O_3$, $ThO_2$, NiO and $Nb_2O_5$ The optimum sensitivity composition for various gases were 90w/o $SnO_2$-9w/o $In_2O_3$-1w/o MgO for $H_2$, $C_2H_2$ CO and $C_3H_8$ and 95w/o $SnO_2$-4w/o $In_2O_3$-1w/o MgO for $CH_4$. The sample which has been made by wet process than dry process had predominated sensitivity for each gases and particle size of the sample coprecipitated with PH=9 was 0.1${\mu}{\textrm}{m}$ The $SnO_2$-In2_O_3-MgO$ system doped with 2w/o $Nb_2O_5$ and NiO was the most sensitive for $H_2$ and $C_2H_2$ gas. In $SnO_2$-In2_O_3-MgO$ system doped with $ThO_2$ the sensitivity of $H_2$ gas was decreased but CO gas was in-creased when dopant con was increased.

  • PDF

The Enhancement of Selectivity in Thick Film SnO2 Gas Sensors by Additives and Pattern Recognition (첨가제 및 패턴인식에 의한 후막 SnO2 가스센서의 선택성 향상)

  • 정해원;김종명;박희숙;윤기현
    • Journal of the Korean Ceramic Society
    • /
    • v.40 no.11
    • /
    • pp.1073-1077
    • /
    • 2003
  • The Sn $O_2$-based gas sensors can detect inflammable and toxic gases of low concentration by the modulation of surface resistance, but they lack in selectivity on the whole. To give selectivity to the Sn $O_2$-based gas sensors, studies on the sensing mechanism, selective gas sensing materials and signal processing techniques are demanded. Ethanol (C$_2$ $H_{5}$OH) and acetonitrile ($CH_3$CN) were confirmed to undergo catalytic oxidation on Sn $O_2$ by gas chromatography. PdCl$_2$-doped Sn $O_2$ showed excellent sensitivity to ethanol and acetonitrile, while La$_2$ $O_3$-doped Sn $O_2$ showed excellent sensitivity to ethanol, but poor sensitivity to acetonitrile. Using these two sensors and pattern recognition, the selectivity to acetonitrile is greatly enhanced. The minimum detection level of acetonitrile was 15 ppm in air and 20 to 100 ppm when exposed to interfering gases together with acetonitrile.

A Study on the determination of Residual Antibiotics and Synthetic Antibacterial Agents in Meas (II) - Simultaneous Gas Charomatography/Mass Spectrometry Analysis of Penicillin G, Chloramphenicol and Thiamphenicol - (식육중의 잔류 항생.항균제의 검정에 관한 연구 (II) - Penicillin G , Chloramphenicol, Thiamphenicol, Gas chromatography/Mass spectrometry 동시 분석 -)

  • 류재천;양종순;서지원;김명수;박종세
    • Journal of Food Hygiene and Safety
    • /
    • v.8 no.1
    • /
    • pp.9-15
    • /
    • 1993
  • In an attempt to quantitate and qualitate residual antibiotics and antibacterial agents in meat simultaneously, we studied a gas chromatography-mass spectrometry(GC/M8) analysis. For a simultaneous analysis of penicillin G, chloramphenicol and thiamphenicol in meat, a simple and rapid clean-up procedure including extraction with 0.01 M EDTA-2Na Mcilvaine buffer (pH 4.0), defatting with n-hexane, and elution with 0.01M-methanolic oxalic acid from Bond Elute $C_{18}$ cartridge, and quantitation by selected ion monitoring (SIM) mode after derivatization was performed. The recoveries (%) of penicillin G, chloramphenicol and thiamphenicol (CV, %) at 1 ppm fortification level were 63.5 (7.6), 76.3 (8.1) and 84.7 (2.0), and the detection limits of those were 0.6, 0.085 and $0.084\;\mu\textrm{g}$ beef, respectively. This method using 81M mode allows excellent detection and quantitation of residual antibiotics and antibacterial agents in meat. Moreover, confirmation by a full scan electron impact mass spectrum is possible if residual level in the sample in above 1 ppm.

  • PDF

Laser-induced plasma emission spectra of halogens in the helium gas flow and pulsed jet (헬륨 가스 플로우와 가스 펄스 젯에서 할로겐족 원소들의 레이저유도 플라즈마 방출 스펙트럼)

  • Lee, Yonghoon;Choi, Daewoong;Gong, Yongdeuk;Nam, Sang-Ho;Nah, Changwoon
    • Analytical Science and Technology
    • /
    • v.26 no.4
    • /
    • pp.235-244
    • /
    • 2013
  • Detection of halogens using laser-induced breakdown spectroscopy (LIBS) in open air is very difficult since their strong atomic emission lines are located in VUV region. In NIR region, there are other emission lines of halogens through electronic transitions between excited states. However, these lines undergo Stark broadening severely. We report the observation of the emission lines of halogens in laser-induced plasma (LIP) spectra in NIR region using a helium gas flow. Particularly, the emission lines of iodine at 804.374 and 905.833 nm from LIPs have been observed for the first time. In the helium ambient gas, Stark broadening of the emission lines and background continuum emission could be suppressed significantly. Variations of the line intensity, plasma temperature, and electron density with the helium flow rate was investigated. Detection of chlorine and bromine in flame retardant of rubbers was demonstrated using this method. Finally, we suggest a pulsed helium gas jet as a practical and ecomonical helium gas source for the LIBS analysis of halogens in open air.