• 제목/요약/키워드: Gas condensation

검색결과 230건 처리시간 0.022초

Malon 산 Ester 유도체와 요소와의 축합에 관한 연구 (Studies on the Condensation with Malonates and Urea)

  • 국채호;조윤상;주상섭
    • 약학회지
    • /
    • 제18권2호
    • /
    • pp.125-132
    • /
    • 1974
  • The by-products which were occured in the synthesis of 5-ethyl-5-phenyl barbituric acid were isolated by column chromatography combined with gas-liquid chromatography and were identified by elemental analysis, ir, nmr and mass spectroscopy ; major by-products were ethyl${\alpha}$-phenylbutyrate and ${\alpha}$-phenylbutyramide. The alkoxide which was known to be a condensation agent not only accelerated the condensation but also did the decarboxylation. And the entity concenrned with the condensation with diethyl ethylphenylmalonate was not urea but N-monosodium urea.

  • PDF

초전도 박막 제작을 위한 산화 시스템 구축 및 평가 (Construction and Evaluation of Oxidation System for Superconductor Thin Film)

  • 임중관;박용필;송경용
    • 한국전기전자재료학회논문지
    • /
    • 제16권2호
    • /
    • pp.163-167
    • /
    • 2003
  • Ozone is strong and useful oxidizing gas for the fabrication of oxidation thin films. In order to obtain high quality thin film, the ozone concentration must be increased. An ozone condensation system is evaluated in the viewpoint of an ozone supplier for oxidation thin film growth. Ozone is condensed by the adsorption method and ozone concentration reaches 8.5 mol% by 2.5 h after the beginning of the ozone condensation is negligible if the condensed ozone is transferred between the ozone condensation system and the film growth chamber within a few minutes. CuO peak which is the result of the obtained Cu-films using condensed ozone appears by XRD patterns.

내경 1.77 mm관내 R-22와 R-410A의 응축열전달 (The Condensation Heat Transfer of R-22 and R-410A in an Inner Diameter Tube of 1.77 mm)

  • 손창효;노건상
    • 한국가스학회지
    • /
    • 제12권1호
    • /
    • pp.48-53
    • /
    • 2008
  • 본 연구는 세관내 R-22와 R-410A의 응축 열전달 계수를 실험적으로 조사하였다. 냉매 순환루프의 주요 구성품은 수액기, 변속 액펌프, 질량유량계, 증발기(예열기), 응축기(시험부)로 구성된다. 시험부는 평활, 수평 동관으로 내관의 내경과 외경이 각각 1.77 mm와 3.38 mm이다. 냉매 질량유속은 $450{\sim}1050\;kg/(m^2s)$이고, 입출구 평균건도는 $0.05{\sim}0.095$이다. 주요 실험결과를 요약하면, 응축 열전달 계수는 질량유속과 건도이 증가할수록 증가하였고, R-410A의 응축 열전달 계수가 R-22에 비해 약간 높았다. 종래의 상관식과 비교한 결과, 저건도와 저질량유속을 제외하고는 실험값과 종래의 상관식으로 예측한 값의 차이가 큰 것으로 나타났다.

  • PDF

Local Heat Transfer Coefficients for Reflux Condensation Experiment in a Vertical Tube in the Presence of Noncondensible Gas

  • Moon, Young-Min;No, Hee-Cheon;Bang, Young-Seok
    • Nuclear Engineering and Technology
    • /
    • 제31권5호
    • /
    • pp.486-497
    • /
    • 1999
  • The local heat transfer coefficient is experimentally investigated for the reflux condensation in a countercurrent flow between the steam-air mixture and the condensate, A single vertical tube has a geometry which is a length of 2.4m, inner diameter of 16.56mm and outer diameter of 19.05mm and is made of stainless steel. Air is used as a noncondensible gas. The secondary side has a shape of annulus around vertical tube and the lost heat by primary condensation is transferred to the coolant water. The local temperatures are measured at 11 locations in the vertical direction and each location has 3 measurement points in the radial direction, which are installed at the tube center, at the outer wall and at the coolant side. In three different pressures, the 27 sets of data are obtained in the range of inlet steam flow rate 1.348∼3.282kg/hr, of inlet air mass fraction 11.8∼55.0%. The investigation of the flooding is preceded to find the upper limit of the reflux condensation. Onset of flooding is lower than that of Wallis' correlation. The local heat transfer coefficient increases as the increase of inlet steam flow rate and decreases as the increase of inlet air mass fraction. As an increase of the system pressure, the active condensing region is contracted and the heat transfer capability in this region is magnified. The empirical correlation is developed by 165 data of the local heat transfer. As a result, the Jacob number and film Reynolds number are dominant parameters to govern the local heat transfer coefficient. The rms error is 17.7% between the results by the experiment and by the correlation.

  • PDF

화학기상응축공정으로 제조한 Fe(C) 나노캡슐의 합성 및 미세구조 (Synthesis and Microstructure of Fe(C) Nanocapsules by Chemical Vapor Condensation)

  • 이정한;김성덕;김진천;최철진;이찬규
    • 한국분말재료학회지
    • /
    • 제11권6호
    • /
    • pp.515-521
    • /
    • 2004
  • Fe(C) nanocapsules were prepared by the chemical vapor condensation(CVC) process using the pyrolysis of iron pentacarbonyl $(Fe(CO)_5)$. Their characterizations were studied by means of X-ray diffraction, X-ray photoelectron spectrometer and transmission electron microscopy. The long-chained Fe(C) nanocapsules hav-ing the mean size of under 70 nm could be obtained below $1100^{\circ}C$ in different gas flow rates. The particle size of the powders was increased with increasing decomposition temperature, but it was decreased with increasing CO gas flow rate. The Fe powders produced at $500^{\circ}C$ consisted of three layers of ${\alpha}$-Fe/$Fe_3C$/amorphous phases, but it had two phase core-shell structure which consited of $Fe_3C$ phase of core and graphite of shell at $1100^{\circ}C$.

크라이오펌프 알곤 회복시간 측정과 알곤 불안정성 분석 (Measurement of the Ar Recovery Time of a Cryopump and Analysis on the Ar Instability)

  • 인상렬;이동주
    • 한국진공학회지
    • /
    • 제22권5호
    • /
    • pp.225-230
    • /
    • 2013
  • 크라이오펌프는 응축과 흡착을 통해 기체를 배기하므로 극저온 표면 온도와 증기압이 배기성능에 큰 영향을 미친다. 어느 부분의 온도가 어중간하면 한번 응축했던 기체분자가 방출과 재응축 또는 재흡착을 반복하여 진공용기 압력이 어느 선 이하로 떨어지지 않고 심한 요동을 나타낸다. 어떤 기체나 특정 온도 범위에서 이런 불안정성이 나타날 수 있지만 크라이오펌프를 많이 사용하는 스퍼터 장치의 공정기체인 알곤을 배기할 때 불안정성이 발생하는 것은 좋지 않다. 본 논문에서는 알곤 회복시간 측정실험을 수행하면서 크라이오펌프의 알곤 불안정성의 원인과 대책을 분석했다.

동해-1 가스전 B2 저류층의 생산성 분석에 관한 Field Case Study (Field Case Study for the Productivity Analysis of B2 Reservoir, Donghae-1 Gas Field)

  • 권순일;류상수;권오광;성원모
    • 한국가스학회지
    • /
    • 제5권1호
    • /
    • pp.60-72
    • /
    • 2001
  • 본 연구에서는 국내대륙붕 제 6-1광구 고래 V 구조 (동해-1 가스전)의 B2 저류층에 대한 생산성 분석을 수행하기 위해 상평형 모델과 물질평형식 및 유임유동식에 근거한 사용자 친화적 생산거동분석 모델을 개발하였다. 이 모델에서는 저류층 주변에 대수층이 존재하는 경우에 대해서도 분석이 가능하도록 설계하였다. 또한 콘덴세이트가 생산성에 미치는 효과를 분석하기 위해 저류층에서 생성된 콘덴세이트를 겉보기스킨의 효과로 고려함으로써 저류층 평균압력에 대한 정저압력을 산출하는데 있어서 콘덴세이트에 의한 효과를 묘사하고자 하였다. 상기 모델을 활용하여 다양한 생산시스템에 대해 분석한 결과, B2층을 연간 5500 MMSCF 생산하는 비폐쇄시스템 즉 저류층이 10배 유한대수층과 270$^{\circ}C$ 유입각도로 접해있 다고 가정할 때, B2 저류층은 생산 개시 후 8년 6개월이 결과한 시점에서도 계산된 정저압력이 운영 정저압력 1298 psia보다 높게 산출되어 최대 생산을 유지할 수 있음을 확인하였다. 또한 콘덴세이트는 생산 개시 1100일이 경과한 시점에서부터 생성되기 시작하여 1270일이 지나면 저류층 전체에 콘덴세이트가 존재하는 것으로 나타났다. B2층은 생산이 종료되는 시점까지 많은 양의 물이 유입되는 관계로 저류층의 압력이 충분히 유지되고 콘덴세이트의 생성량이 적어 이에 따라 스킨인자의 증가도 크지 않게 산출되었다.

  • PDF

금속 산화물 박막 제작을 위한 산화 시스템의 평가 (Evaluation of Oxidation System for Metal Oxide Thin Film)

  • 임중관;김종서;박용필
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2003년도 춘계종합학술대회
    • /
    • pp.590-593
    • /
    • 2003
  • 금속 산화물 박막 제작에 유효한 산화가스로 오존가스를 채택했다. 고품질의 산화 박막을 얻기 위해 고농도 오존이 필요하여 오존 농축 시스템을 구축 및 평가하였다. 이 장치는 실리카겔로 오존의 선택 흡착을 이용해, 농축 공정 시작 후 유입 농도 8.5 mol%가 검출되는 2.5 h에서 농축이 완료되고, 진공 배기로 고농도 오존가스를 생성하였으며, 성막 장치까지 가스가 공급되는 몇 분 동안은 자연분해 효과를 무시할 수 있었다.

  • PDF

A Theoretical and Experimental Study of the Steam Condensation Effect on the CCFL in Nearly Horizontal Two- phase Flow

  • Chun, Moon-Hyun;Yu, Seon-Oh
    • Nuclear Engineering and Technology
    • /
    • 제31권6호
    • /
    • pp.618-630
    • /
    • 1999
  • An analytical model that includes the steam condensation effect has been derived and a parametric study has been performed. In addition, a series of experiments were performed and a total of 34 experimental data for the onset of CCFL in nearly horizontal countercurrent two-phase How have been obtained for various flow rates of water. Comparisons of the present CCFL data with slug formation models show that the agreement between the present as well as the existing model and the data is about the same. However, the deviation between the Taitel and Dukler's model predictions and the data is the largest when if j$_{f}$<0.04 m/s. A parametric study of the effect of the steam condensation using the present model shows that, when all local conditions are similar, the model predicted local gas velocities that cause the onset of flooding are slightly lower when condensation occurred. Based on the visual observation and the evaluation of the present work, it has been concluded that the criterion derived for the onset of slug flow can be directly used to predict the onset of inner flooding in nearly horizontal two-phase flow within the experimental ranges of the present work.