• 제목/요약/키워드: Gas analyzer

검색결과 484건 처리시간 0.023초

Design of a Smart Gas Sensor System for Room Air-Cleaner of Automobile (Thick-Film Metal Oxide Semiconductor Gas Sensor)

  • Kim, Jung-Yoon;Shin, Tae-Zi;Yang, Myung-Kook
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권3호
    • /
    • pp.408-412
    • /
    • 2007
  • It is almost impossible to secure the reproductibility and stability of a commercial Thick-Film Metal Oxide Semiconductor Gas Sensor since it is very difficult to keep the consistency of the manufacturing environment. Thus it is widely known that the general Semiconductor-Oxide Gas Sensors are not appropriate for precise measurement systems. In this paper, the output characteristic analyzer of the various Thick-Film Metal Oxide Semiconductor Gas Sensors that are used to recognize the air quality within an automobile are proposed and examined. The analyzed output characters in a normal air chamber are grouped by sensor ranks and used to fill out the characteristic table of the Thick-Film Metal Oxide Semiconductor Gas Sensors. The characteristic table is used to determine the rank of the sensor that is equipped in the current air cleaner system of an automobile. The proposed air control system can also adapt the on-demand operation that recognizes the history of the passenger's manual-control.

Improving Gas Barrier Property of Polymer Based Nanocomposites Using Layer by Layer Deposition Method for Hydrogen Tank Liner

  • Lee, Suyeon;Han, Hye Seong;Seong, Dong Gi
    • Composites Research
    • /
    • 제35권3호
    • /
    • pp.121-126
    • /
    • 2022
  • Owing to advantages of polymeric materials for hydrogen tank liner like light-weight property and high specific strength, polymer based composites have gained much attention. Despite of many benefits, polymeric materials for fuel cell tank cause problems which is critical to applications as low gas barrier property, and poor processability when adding fillers. For these reasons, improving gas barrier property of polymer composites is required to study for expanding application fields. This work presents impermeable polymer nanocomposites by introducing thin barrier coating using layer by layer (LBL) deposition method. Also, bi-layered and quad-layered nanocomposites were fabricated and compared for identifying relationship between deposition step and gas barrier property. Reduction in gas permeability was observed without interrupting mechanical property and processability. It is discussed that proper coating conditions were suggested when different coating materials and deposition steps were applied. We investigated morphology, gas barrier property and mechanical properties of fabricated nanocomposites by FE-SEM, Oxygen permeation analyzer, UTM, respectively. In addition, we revealed the mechanism of barrier performance of LBL coating using materials which have high aspect ratio.

Cycle Resolved NO Emissions and Its Relation with Combustion Chamber Pressure in an S.I. Engine with Fast Response NO Analyzer

  • Sung, Jung-Min;Kim, Hyun-Woo;Lee, Kyung-Hwan
    • Journal of Mechanical Science and Technology
    • /
    • 제17권10호
    • /
    • pp.1563-1571
    • /
    • 2003
  • A fast response NO analyzer was applied to investigate the relation between cycle-by-cycle NO emissions and combustion chamber pressure. NO emissions were sampled at an isolated exhaust manifold of 4-stroke spark ignition engine to avoid the interference of exhaust gas from other cylinders. The linear correlation analysis was performed with collected data of NO emissions and combustion chamber pressure with respect to the various air-fuel mixture ratios and engine loads. The sampled data sets were obtained during 200 cycles at each operating condition. The results showed that there was a typical pattern in NO emissions from an exhaust port through a cycle. It was possible to set a block of crank angle in which the linear correlation coefficient between NO emissions and combustion chamber pressure was high. As the engine load increased, NO emissions were more dependent on combustion chamber pressure after TDC. It was also analyzed that the correlation between two parameters with respect to air-fuel mixture ratio tended to increase as mixture went leaner. Furthermore, this correlation coefficient for the mixture near the lean limit seemed to be kept high even though combustion was unstable.

비분산 적외선 분광법을 이용한 Co2농도 고속 분석기의 Sampling Module 특성에 관한 실험적 연구 (An Experimental Investigation into the Characteristics of Sampling Module for East-Response Co2 Concentration Analyzer with NDIR)

  • 김우석;손덕영;박영무;유재석;이종화
    • 대한기계학회논문집B
    • /
    • 제27권3호
    • /
    • pp.398-405
    • /
    • 2003
  • A fast response analyzer for measuring carbon dioxide concentration has been developed for transient characteristic and researches tested on internal combustion engine. The analyzer uses the well known NDIR(Non-Dispersive Infrared) method with miniaturized detection system, giving a time constant of approximately 30 microsecond, and sampling module consists of capillary tube. Since the transit time and the time constant of the sampling system depend on the sampling conditions, it is necessary to investigate the characteristics of sampling system before applied to exhaust gas measurement in engine. A unique method was designed to study the influence of the diameter of transfer sample line and operating conditions of the FRNDIR on transit time and time constant. A database of transit time and time constant was built up for different measured and simulated pressure conditions. The database can be used for correcting eventual $CO_2$ concentration measurement.

An Experimental Study of Ventilation Effectiveness in Mechanical Ventilation systems using a Tracer Gas Method

  • Lee, Jae keun;Kang, Tae-Wook;Lee, Kam-Gyu;Cho, Min-Chul;Shin, Jin-Hyuk;Kim, Seong-Chan;Koo, Jeong-Hwan;Lee, Jong ho
    • Journal of Mechanical Science and Technology
    • /
    • 제14권11호
    • /
    • pp.1286-1295
    • /
    • 2000
  • The ventilation effectiveness is evaluated as a function of air exchange rate and supply / extract locations in a simplified model chamber using a tracer gas technique of CO$_2$ gas injected into a supply duct. Ventilation systems consist of supply and extract fans, a CO$_2$gas generator, a CO$_2$gas analyzer and a test chamber. The ventilation effectiveness is evaluated using a step-down method based on ASTM Standard E741-83. The room mean age of the model chamber is decreased with increasing air exchange rate fanged from 6to 10 air changes per hour. The ventilation effectiveness of the mechanical inlet/natural extract system is better than that of the mechanical extract system.

  • PDF

석유화학 산업에서의 수행영향인자 및 근본원인 분석 결과 (Analysis of Performance influencing Factor in Chemical Process Industry : A Practical Application)

  • 김은정;유광수;박교식
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 2006년도 에너지.가스.기후변화학회 연합춘계학술대회 및 특별심포지움
    • /
    • pp.294-299
    • /
    • 2006
  • 한국에서는 석유화학 산업의 역사가 30년 이상이 되어 잠재적인 사고의 위험 가능성이 높아지고 있다. 지금까지의 석유화학 산업에서의 전통적인 위험성 평가와 시스템의 제어는 기계적인 결함에만 중점을 두었기 때문에 인간의 행동을 제어하는 것은 간과하여 왔다. 비록 자동화 기술가 제어기술의 발전이 필요함에도 불구하고 인간의 의사 결정 요소는 석유화학 산업에서 사고를 예방하는데 필수적이다. 대부분의 심각한 사고는 부적절한 인간의 행동과 안정장치의 기계적인 결함이 동시에 존재할 경우에 발생한다. A-HRA(Advanced Reliability Analyzer) 소프트 웨어는 석유화학 플랜트 내에서의 인적오류 확률을 분석하고 사고 데이터를 축적하기 위하여 개발되었다. A-HRA 프로그램을 이용하여 1960년대 이후부터 최근 까지 한국의 석유화학 산업에서 발생하여온 인적오류 사고 데이터를 입력하고 사고마다의 근본원인과 수행영향인자를 분석하였다. 이 본문에서는 Root cause Aanlysis을 통한 결과와 PIF(Performance Influencing Factor) 평가 결과를 보여준다. 이 분석 결과는 석유화학 산업의 안전을 극대화 시키면서도 인적오류 제어를 통하여 안전비용을 최저화 시킬 수 있는 대책을 제시할 것이다.

  • PDF

외부혼합형 음속노즐을 사용한 2유체 미립화의 분무특성 (Spray characteristics of twin-fluid atomization using external-mixing sonic nozzles)

  • 박병규;이준식
    • 대한기계학회논문집B
    • /
    • 제21권1호
    • /
    • pp.132-139
    • /
    • 1997
  • Spray characteristics of external mixing sonic twin-fluid atomization nozzles are investigated experimentally. Particle sizes are measured by the Fraunhofer diffraction method using the Malvern particle analyzer, and their radial distributions are obtained using the tomographical transformation technique. The spatial distribution of SMD shows that the drop size increases in the radial direction at a fixed liquid flow rate, and the distribution is getting uniform rapidly as the atomizing gas pressure increases. The SMD decreases as the liquid flow rate increases at a fixed GLR. It is found that the atomization efficiency of the flush type sonic nozzle is superior to that of protrusion type. The effect of laser beam diameter of the particle analyzer on the spatial SMD distribution is minor at present experimental conditions.

유전자 알고리즘을 이용한 저전력 회로 설계 (Designing Circuits for Low Power using Genetic Algorithms)

  • 김현규;오형철
    • 한국지능시스템학회논문지
    • /
    • 제10권5호
    • /
    • pp.478-486
    • /
    • 2000
  • 본 논문에서는 CMOS 디지털 회로상의 플립플롭의 위치를 이동시키는 리타이밍 변환에 유전자 알고리즘을 적용하여 회로의 최적 동작 속도를 유지하면서 전력의 소모를 줄일 수 있는 설계 방법을 제안한다. 제안된 설계 방법은 최적 속도를 구현하는 리타이밍 단계와 유전자 알고리즘이 적용되는 저전력 리타이밍의 두 단계로 이루어진다. 제안된 저전력 리타이밍 설계 도구를 예제 회로의 설계에 적용하고 설계된 회로의 성능을 Synopsys시의 Design Analyzer로 평가한 결과, 임계 경로 지연은 약 30~50% 가량 감소하였으며 동적 전력 소모는 약 1.4~18.4% 가량 감소함을 관찰하였다.

  • PDF

금속 산화물 박막제작을 위한 오존 농도 분석 (Analysis of $O_3$ Concentration for Metal Oxide Thin Films Growth)

  • 임중관;박용필;장경욱;이희갑
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 추계학술대회 논문집 Vol.18
    • /
    • pp.331-332
    • /
    • 2005
  • Ozone is ambient gas which is useful for the fabrication of metal oxide thin films under conditions of molecular beam epitaxy. Ozone is condensed by the adsorption method and its concentration is analyzed using the thermal decomposition method. The concentration of ozone exceeds 90 mol% and ozone is supplied for a sufficiently long time to grow oxide thin films. The ozone concentration is also evaluated using a quadrupole mass analyzer and the accuracy of this method is compared with the results of the thermal decomposition method.

  • PDF

Characteristics of Synthesized Red Cells Using Bovine Hemoglobin as Oxygen Carrier

  • Cho, Eng-Haeng;Hah, Jong-Sik;Kim, Ku-Ja
    • The Korean Journal of Physiology
    • /
    • 제26권1호
    • /
    • pp.37-44
    • /
    • 1992
  • The encapsulation of the Purified bovine hemoglobin with Phospholipids obtained from egg folk was performed using a rotary vacuum evaporator. The prepared Hb-containing liposome (hemosome) had good properties as artificial red blood cell. The shape and size of the hemosomes were measured by a phase contrast microscope and image analyzer. The function of the hemosome as oxygen carrier was tested by measuring oxygen saturation curve with blood gas analyzer and infusing it into rats. The prepared hemosome was 1.184 + 0.423 ${\mu}m$ in diameter and round in shape. $P_{50}$ value of the hemosome solution was 28 mmHg. The synthesized red cells seem to function as oxygen carrier, because the severely bled rats were prolonged in their life by transfusion of the hemosome solution containing bovine hemoglobin.

  • PDF