• Title/Summary/Keyword: Gas Toxicity

Search Result 194, Processing Time 0.021 seconds

A Research for Assessment Fire Toxic Gas of Construction Material Using FT-IR and FED (FT-IR과 FED를 이용한 건축 재료의 연소독성평가에 관한 연구)

  • Kim, Sung-Soo;Cho, Nam-Wook;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.27-31
    • /
    • 2011
  • In this study, combustion toxicity evaluation for building interior materials and study for toxicity as using FT-IR analysis. this experiment for the calculation of toxicity index, it using a cone calorimeter model in KS F ISO/TR 9122-4 as a fire model. It is following ISO 19702 procedure for assessing fire toxic gas using FT-IR. This experiment used calculation method for toxicity index (FED) among the international standards. $LC_{50}$ is a concentration that it can cause death to 50 % of experimental animal in 30 minutes - exposure gas test. comparison with the three kinds of toxicity fire gas of construction materials using toxicity index.

A Toxicity Evaluation for the Toxic Gases of Building Finish Materials (건축물 마감재료 연소가스에 의한 독성평가)

  • Cho, Nam-Wook;Cho, Dong-Ho;Oh, Eun-Ha
    • Journal of the Korean Applied Science and Technology
    • /
    • v.29 no.1
    • /
    • pp.129-140
    • /
    • 2012
  • Smoke toxicity is the test for the toxicity evaluation of smoke and hazardous gas, caused by combustion of building materials and finishing materials. Smoke toxicity can be evaluated by the mean incapacitation time of mice. This test result can be influenced by the health status of mice and test condition. In acute inhalation toxicity test of hazardous gas, no typical clinical findings and histopathologic abnormalities were observed. Tracheitis and bronchitis as well as acute lung inflammation around terminal bronchiole in some mouse of the highest dose group. Through this study, we established the method for inhalation toxicity test of hazardous gas as well as the SOP of inhalation toxicity test. However, in the future studies, the concentration control methods for inhalation technologies on hazardous gas will be needed to improve continuously and also further studies on other gas inhalation toxicity will be needed to conduct.

The Combustion Gases Toxicity Evaluation of Plastics Material by Colorimetric Gas Detector Tubes (가스검지관법에 의한 플라스틱재료의 연소가스 독성평가)

  • 박영근;김동일;현성호
    • Fire Science and Engineering
    • /
    • v.16 no.4
    • /
    • pp.77-84
    • /
    • 2002
  • In this paper, we had analyzed comsbustion gases using a GASTEC colorimetric gas detector tube according to the method of NES 713 in order to combustion gases toxicity evaluation for beads polystyrene foam, extruded polystyrene foam, rigid polyurethane foam, flexible polyurethane foam, flexible polyvinyl chloride pipe, vinyl floor cover, polyethyelene foam(flame retardant untreated) and polyethyelene foam (flame retardant treated) of plastics material. As results of gas analyses by using this method, comsbustion gases producted from small specimens of plastics material had reached fatal to man at 30 minutes exposure time that had possesed toxicity index of more than 1. Toxicity indexes of each specimen were estimated range of 4.3∼179.2, flexible polyvinyl chloride showed the hightest toxicity index at 179.2, and beads polystyrene foams showed the lowest toxicity index at 4.3.

A Study on the Flame Retardant Performance and Toxicity of the Painting Wood Painted with Flame Retardant Solution (방염처리된 단청목재의 방염성능 및 유독성에 관한 연구)

  • Kim, In-Beom;Hyun, Seong-Ho
    • Fire Science and Engineering
    • /
    • v.23 no.5
    • /
    • pp.66-71
    • /
    • 2009
  • In this study, I evaluated toxicity that analyze performance of flame-retardant about flame-retardant painting wood and combustion gas that is based on the toxicity index. Processing condition of flame retardant solution and treatment method of samples didn't affect greatly to performance of flame retardant. Occurrence of combustion gas showed a almost similar result from the sample which spraying flame retardant solution and toxicity corresponds to high level, Hazard Class III, and the flame retardant solution saturation sample which makes put out Hazard Class II which is a low toxicity relatively.

A Study on Toxicity Bio-markers of a Mouse using Combustion Gas SO2 generated from Fire (마우스(mouse)를 이용한 건축물 마감재료 연소가스 SO2의 독성생체지표 연구)

  • Rie, Dong-Ho;Cho, Nam-Wook;Choi, Soon-Young
    • Journal of the Korea Safety Management & Science
    • /
    • v.14 no.1
    • /
    • pp.43-51
    • /
    • 2012
  • This study was carried out to observe the impacts of a mouse's inhalation of toxic gas SO2 generated from combustion on its organs by different concentrations. As for research methods: First, after concentrations of SO2 generation from combustion had been set to three: low (10.4 ppm), middle (24.9 ppm) and high (122 ppm) through Gas Toxicity Testing Method (KS F 2271) and SO2 combustion gas was exposed to eight mice in each concentration. Five mice that were able to move based on LD50, a criterion, which sets the down time of a mouse's average behaviors to over 9 minutes, were randomly selected in each concentration, and they were set up as the subjects of the study on toxicity bio-markers. Second, tissues were taken from heart, liver, lungs, spleen and the thymus gland of the mice selected in each concentration and a pathological examination of them was carried out. As a result, microvascular congestion appeared in the heart, and cell necrosis, cortex congestion and tubule medulla congestion, etc. in each concentration were observed in addition to vascular congestion in liver, lungs, spleen and the thymus gland. Also, it was found that the higher the concentrations of SO2 exposure is, the greater, the changes in the organs get. Through this study, SO2 of various toxic gases generated from fire turned out to affect the tissues of each organ of a mouse, it is expected that the toxic gases may greatly affect human body in case of actual fire, and this study is evaluated as having a significance as a basic data on inhalation toxicity assessment of toxic substances generated in combustion.

A study on combustion gas toxicity of polymeric materials using FTIR gas analysis (FTIR 가스분석에 의한 고분자재료의 연소가스독성 평가)

  • Lee, Doo-Hyung;Kong, Young-Kun
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.5 no.4 s.19
    • /
    • pp.79-84
    • /
    • 2005
  • When polymeric materials are exposed to fire condition, a lot of heat and toxic gases evolved and cause damage to property and human being. Especially toxic gases are major hazard to life safety. This study FTIR(Fourier Transform Infrared) spectrometer analysis was performaed to etermine the gas analysis and the concentration of gases evolved from PVC, FRP, SMC and Ureathane foam using ASTM E 1678 fire model. And FED toxicity index calculated from FTIR data also presented. By the comparison of animal test adopted in KS F 2271 and FTIR gas analysis method, FTIR gas analysis method can replace current animal toxicity test and produce precise and quantitative combustion gas data.

Toxicity Factor Analysis through the Exposure Experiment of the Combustion Products on Wood-Based Materials (목재 기반 소재의 연소생성물 노출 실험을 통한 독성요인 분석)

  • Kim, Nam-Kyun;Park, Jeong-Ho;Cho, Nam-Wook
    • Fire Science and Engineering
    • /
    • v.30 no.6
    • /
    • pp.57-63
    • /
    • 2016
  • In this study, the toxicity of combustion products of wood-based materials (MDF, OSB) were analyzed using experimental animal techniques. The average deed stopping time of MDF was shorter than that of OSB. This means that the toxicity of the combustion products of MDF is higher than that of OSB. To analyze the cause of the result quantitatively, Fourier transform infrared spectroscopy (FT-IR) of the gas phase materials was performed. Qualitative analysis result, CO and $CO_2$ were detected. Quantitative analysis results, the gas generation rate was higher in OSB than in MDF. Blood analysis of mice revealed, COHb to be higher in OSB than MDF. A correlation between the gas generation rate and COHb was found. Currently, the toxicity of the combustion products of the materials is being examined using the toxicity index, such as Fractional Effective Dose (FED). The FED is based on the gas emissions. The average deed stopping time decreased with increasing toxicity of exposed material. On the other hand, the result of this study showed that, the CO emissions of OBS were 186.5% that of MDF. The COHb of OSB was > 129.6% that of MDF. Nevertheless, the average deed stopping time of the OSB is 51 seconds longer than that of MDF. Therefore, more toxicity studies on factors other than the gas phase materials in the combustion products will be needed.

Toxicity Assessment of Gas Phase in Cigarette Smoke Using Cell-free Assay

  • Park, Chul-Hoon;Sahn, Hyung-Ok;Shin, Han-Jae;Lee, Hyeong-Seok;Min, Yaung-Keun;Hyun, Hak-Chul
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.29 no.2
    • /
    • pp.110-117
    • /
    • 2007
  • In vitro toxicity tests such as cytotoxicity, mutagenicity and genotoxicity assay are useful for evaluating the relative toxicity of smoke or smoke condensates obtained from different cigarette configurations. A major disadvantage of these tests is relatively time-consuming, complicated and expensive. Recently, a cell-free glutathione consumption assay (GCA) as a rapid and simple screening method for the toxicity assessment of smoke has been reported by Cahours et al. (CORESTA, 2006). This study was carried out to assess the GCA application capable of predicting the toxicity of gas/vapor phase (GVP) of cigarette smoke and to identify individual compounds responsible for the glutathione (GSH) consumption in smoke. Each GVPs from 2R4F, standard cigarette, carbon filter cigarette (ExC) and new carbon filter cigarette (ExN), test cigarettes were collected by automatic smoking machine and evaluated the relative toxicity by GCA and neutral red uptake (NRU) assay. Toxic compounds existed in smoke were also chosen, relative toxicities of these compounds were screened by using two methods and compared individually. The overall order of toxicity by GCA was 2R4F > ExC > ExN, which was consistent with the result of Neutral Red Uptake assay. The levels of carbonyl compounds of ExN were lower than those of 2R4F and ExC, indicating that GSH consumption was associated with carbonyl compound yields. A major toxicant under current study is acrolein, which contributed to more than half of the GSH consumption. Collectively, the toxicity of GVP determined by GCA method may be mainly attributed to acrolein.

Changes of [A-a] gas Gradient in Rabbits with Oxygen Toxicity (산소중독시 가토의 [A-a] gas Gradient 의 변화)

  • 이두연
    • Journal of Chest Surgery
    • /
    • v.20 no.1
    • /
    • pp.1-12
    • /
    • 1987
  • Respiratory care with oxygen inhalation is often a necessity to maintain life, and it is one of the important therapeutic adjuncts in respiratory disease and in intensive care after surgery. However, it has been reported that oxygen toxicity occurs after prolonged exposure to 100% 0, [Smith, 1899; Kistler et al. 1967; Schaffner et al. 1967; Rowland and Newman, 1969. Subjective symptoms of oxygen toxicity include tracheal irritation, frequent cough, some burning sensation in the trachea, tachypnea, severe dyspnea, etc. [Welch, 1963; Fisher et al, 1968; Milier et al, 1970; Clark and Lambertsen, 1971; Sackner, 1975]. Pathologic findings are atelectasis, injuries to the pulmonary capillaries and hemorrhage in the alveoli in gross specimens. There can be inflammation, proliferation of fibrin, thickening of alveolar membranes, degeneration of collagen fibers and interstitial edema in the microscopic findings. [Penrod, 1956; Cedergren, 1959; Bean, 1965; Schaffner, 1967]. Dubois and colleagues [1961] found that the amount of pulmonary surfactant was decreased in oxygen toxicity and atelectasis followed by the decreased pulmonary surfactant. Many authors reported that vital capacity, inspiratory force, pulmonary compliance, pulmonary capillary blood flow and pulmonary elasticity were deceased and arteriovenous shunting increased. [Comroe et al, 1945; Fuson et al, 1965; Kistler et al, 1966; Knowles and Blenner-hassett, 1967; Barber et al, 1978]. Many human volunteers were examined after prolonged exposure in a high oxygenated chamber and there were a few reports on animals with oxygen toxicity, subjects including rabbits. Gas partial pressures of alveoli and arteries were measured in rabbits exposed to 100% $O_2$ and the alveolar-arterial gas gradients were analyzed, which is the basis for the study of oxygen toxicity. These rabbits were divided into two groups; rabbits under natural respiration, and second group under artificial respiration with a respirator. The alveolar $PO_2$ [$P]AO_2$] and $PCO_2$ [$PACO_2$], and the arterial $PO_2$ [$PaO_2$] were measured under varying $O_2$ pressures; 15% $O_2$, 21% $O_2$ and 100% $O_2$.

  • PDF

A Comparative Study on Toxic Gas Index and Stop Time of Mouse Activity (연소독성지수와 마우스 행동정시시간 비교 연구)

  • Cho, Nam-Wook;Lee, Jong-Cheon;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.25 no.4
    • /
    • pp.35-41
    • /
    • 2011
  • Casualties due to toxic smoke products have been reported as major fire damage. There are various tests in order to evaluate toxic smoke from a fire at home and abroad, and KS F 2271 as a test of the gas hazard of building finish materials has been conducted in Korea. The current test of the gas hazard exposes rodent, laboratory rat, to smoke gases to evaluate combustion gas toxicity by measuring acting time of that. this study performed a test of the gas hazard for combustible polymer material, Urethane and rubber flooring, and determined gases with the FT-IR. Quantitative results compared with standard value defined in BS6853 and toxicity index (R) was calculated. Using relative comparison with animal test and the toxicity index, We tried a variety of toxicity evaluation by correlation analysis of two tests.