• 제목/요약/키워드: Gamma emission tomography

검색결과 60건 처리시간 0.032초

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1992년도 춘계학술대회
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF

SiPM을 사용한 두 층의 반응 깊이를 측정하는 양전자방출단층촬영기기의 검출기 모듈 설계 (Design of Two Layer Depth-encoding Detector Module with SiPM for PET)

  • 이승재
    • 한국방사선학회논문지
    • /
    • 제13권3호
    • /
    • pp.319-324
    • /
    • 2019
  • 실리콘광전증배관(Silicon Photomultiplier, SiPM)과 두 층의 섬광 픽셀 배열을 이용한 반응 깊이 측정 검출기를 설계하였으며, 위치 측정 능력을 DETECT2000을 사용하여 검증하였다. 섬광 픽셀의 면 처리와 반사체 조합을 통해 섬광 픽셀과 감마선이 반응한 위치를 추적하였다. 아래층은 광학적으로 연결된 부분을 제외하고 반사체로 처리하였으며, 위층은 가장 외곽부분을 제외하고 모두 광학적으로 연결되도록 처리하여 빛의 공유가 아래층에 비해 자유롭도록 구성하였다. 거울반사체와 난반사체, 섬광 픽셀의 거친 면과 매끈한 면의 조합을 통해 평면 영상을 획득하였으며, 층별 영상이 생성되는 위치를 측정하여 분석하였다. 앵거 알고리듬을 사용하여 SiPM의 16채널 신호를 4개의 채널로 감소시켜 영상을 재구성하였다. 섬광 픽셀의 거친면과 모든 반사체 조합에서 두 층으로 구분되는 것을 확인할 수 있었으며, 매끈한 면일 경우에는 모두 층 구분이 불가능한 것을 확인할 수 있었다. 따라서 거친 면의 섬광 픽셀과 반사체 조합을 사용한 검출기를 사용할 경우 전임상용 PET에서 반응 깊이 측정을 통해 검출 시야 외곽에서의 공간분해능을 향상시킬 수 있을 것이다.

의료기관 방사선 종사자의 직무별 개인피폭선량에 관한 연구 (Medical Radiation Exposure Dose of Workers in the Private Study of the Job Function)

  • 강천구;오기백;박훈희
    • 핵의학기술
    • /
    • 제15권2호
    • /
    • pp.3-12
    • /
    • 2011
  • 본 연구는 방사성동위원소의 의학적 이용도가 증가함에 따라 의료기관 핵의학과 방사선관계종사자의 직무별 방사선 이용에 대한 개인 방사선피폭선량의 실태를 파악하여, 방사선 위험에 대해 경각심을 고취시키고, 방사선 관계종사자들에게 안전관리와 합리적인 피폭선량 관리에 도움을 주고자 분석하였다. 2010년 1월 1일부터 2010년 12월 31일까지 의료기관에서 근무하는 방사선종사자로 분류되어 개인 방사선피폭선량 측정을 정기적, 연속적으로 1년간 조사 관리된 540명의 종사자를 대상으로 부서별, 선량영역구간별, 근무기간별, 직무별 관련업무를 파악하여 심부선량에 대하여 연간평균피폭선량을 각각 분석하였다. 분석법으로는 빈도분석과 ANOVA를 시행하였다. 의료기관 방사선종사자의 부서별 연간피폭선량은 핵의학과 4.57 mSv로 가장 높았으며, 심장혈관중재술실 2.09 mSv, 마취통증의학과 1.42 mSv, 영상의학과 1.10 mSv, 구강악안면 방사선과 0.59 mSv, 방사선종양학과 0.50 mSv 순으로 높게 나타났다. 선량영역별 분포는 핵의학과, 심장혈관중재술실에서 5.01~19.05 mSv의 높은 선량영역분포를 보였으며, 부서별 방사선사의 연간피폭선량은 핵의학과 7.14 mSv로 가장 높은 피폭선량을 보이고 있으며, 심장혈관중재술실 1.46 mSv로 높았고, 영상의학과 0.97 mSv, 구강악안면방사선과 0.66 mSv, 방사선종양학과 0.54 mSv 순으로 나타났다. 세부업무에 따른 직무별 연간평균피폭선량은 싸이크로트론 관련 합성 업무 17.47 mSv로 가장 높은 피폭선량을 보였으며, Gamma camera 영상실 7.24 mSv, PET/CT 영상실 업무가 7.60 mSv로 높게 나타났고, 인터벤션 2.04 mSv, 심혈관중재술실 1.46 mSv, 일반촬영 1.21 mSv, Primart 치료실 0.90 mSv, 구강악안면방사선과 일반촬영 0.66 mSv 순으로 나타났다. 근무기간별, 선량영역별에 따른 연간평균피폭선량은 구강악안면방사선과에서는 10~14년 종사자가 1.01~3.00 mSv로 높은 평균선량을 보였고, 방사선종양학과는 모든 근무기간에 따라 0.00~1.00 mSv 의 낮은 선량영역구간에서 분포를 보였으며, 심혈관중재술실은 10~14년, 15~19년 근무에 따라 각각 1.01~3.00 mSv 선량영역구간에서 분포하였으며, 영상의학과에서는 1~4년, 5~9년 종사자가 각각 1.01~8.00 mSv의 가장 높은 선량영역구간에서 분포를 보였고, 핵의학과에서는 1~4년, 5~9년 종사자가 각각 3.01~19.05 mSv 의 가장 높은 선량영역구간에서 분포를 보였으며, 10~14년, 15~19년 종사자에서도 각각 3.01~15.00 mSv의 높은 선량영역구간에서 분포를 보였다. 이와 같은 결과로 볼 때 의료기관에서 근무하는 방사선관계종사자의 대부분이 현재의 방사선 안전관리가 실효성 있게 이루어지고 있었으며, 직무특성에 따라 많은 차이가 있는 것을 알게 되었다. 그러나 방사선 피폭을 최소화시키는 노력이 필요하며, 이를 위해서 체계적 교육과 합리적인 피폭량 관리를 위한 체계가 필요하다고 사료된다.

  • PDF

핵의학과 종사자의 방사성동위원소 체내오염 측정 (Detection and Measurement of Nuclear Medicine Workers' Internal Radioactive Contamination)

  • 정규환;김용재;장정찬;이재기
    • 핵의학기술
    • /
    • 제13권3호
    • /
    • pp.123-131
    • /
    • 2009
  • 본 논문에서는 국내 의료기관 종사자 중 핵의학과 종사자 일부를 선정하여 방사성동위원소에 의한 체내오염 여부와 정도를 정량적으로 측정한 후 그 결과에 근거하여 선량을 평가하였다. 선량평가를 위해 서울시내에 소재하는 대형병원 3곳의 핵의학과 종사자 25명을 측정 대상자로 선정한 후 각 개인의 소변시료를 채취하여 측정하였다. 시료는 주 1회 채취하였으며 종사자에 따라 6~10회에 걸쳐 각 회당 100~200 mL 정도의 양을 채취한 후 고순도게르마늄반도체검출기를 사용하여 시료를 측정 하였다. 측정된 결과에 근거하여 방사성동위원소의 섭취량을 평가하였고 예탁유효선량을 평가하는 도구로 IMBA 전산프로그램을 사용하였다. IMBA 프로그램으로 평가가 불가능한 반감기가 매우 짧은 $^{99m}Tc$, $^{123}I$ 등과 같은 핵종에 의한 선량은 국제원자력기구에서 권고하는 방법을 적용하여 선량을 평가하였다. 채취한 소변시료를 대상으로 방사성핵종을 계측, 분석한 결과 $^{99m}Tc$, $^{123}I$, $^{131}I$, $^{201}Tl$ 핵종 등이 검출되었고 양전자방출단층 촬영에 사용되는 $^{18}F$ 핵종도 검출되었다. 계측된 결과로부터 평가된 예탁유효선량은 0~5 mSv의 분포를 보였으나 대부분 1mSv 미만으로 나타났다. 1 mSv를 초과한 종사자는 모두 3명으로 이들 모두는 선원의 분배와 취급에 직접적으로 참여한 종사자들이었고 간호사의 경우 1 mSv를 초과한 사람이 한 사람도 발생하지 않았다. 그러나 보다 정확하고 상세한 결과를 도출하기 위해서는 계절적 요인을 구분하기 위한 장기적인 연구가 필요하며 측정대상자의 수를 확대할 필요가 있을 것으로 판단된다. 현재로서는 대부분의 핵의학과 종사자들은 방사성 핵종에 의한 체내오염 정기 감시를 실시할 필요가 없을 것으로 여겨지며 그에 따른 방사선학적인 건강상의 영향도 우려할 필요가 없는 것으로 판단되지만 불필요한 소량의 피폭이라도 줄이기 위해서는 주기적으로 작업환경을 측정하거나 공기 중 방사성핵종 농도 감시를 가능한 한 자주 실시하는 것이 바람직 할 것으로 판단된다.

  • PDF

양릉천-현종 전침치료가 뇌경색환자 및 정상인의 뇌혈류에 미치는 영향 - SPECT와 SPM을 이용한 연구 - (Effect of GB 34-GB 39 Electro-acupuncture on Regional Cerebral Blood Flow in Stroke Patients and Normal Volunteers Evaluated by $^{99m}Tc-ECD$ SPECT)

  • 한진안;정동원;배형섭;박성욱;정우상;박정미;고창남;조기호;김영석;김덕윤;문상관
    • 대한한의학회지
    • /
    • 제27권3호
    • /
    • pp.187-200
    • /
    • 2006
  • Objectives: Acupuncture has been applied in Asia for thousands of years, especially to rehabilitation after stroke. It has been reported that acupuncture increased cerebral blood supply and stimulated the functional activity of brain nerve cells shown by using brain imaging techniques. This study was to evaluate the effect of GB 34-GB 39 electro-acupuncture (EA) on regional cerebral blood flow (rCBF) in stroke patients and normal volunteers using single photon emission computed tomography (SPECT). Methods: The study procedure was divided into two parts: patients and volunteers studies. For the patients study, ten ischemic stroke patients (3 males, 7 females, mean age $68.5{\pm}8.9$ years old) were selected. Baseline brain SPECT was done with triple head gamma camera (MultiSPECT3, Siemens, USA) after intravenous administration of 1,110 MBq of $^{99m}Tc-ECD$. Fifteen-minute EA at GB 34 and GB 39 were applied on the affected limb. The same dose of $^{99m}Tc-ECD$ was injected during the EA, and the second set of SPECT images wasobtained. Using the computer software (ICON 7.1, Siemens, USA), 3 SPECT slices (upper, middle, lower) surrounding the brain lesion were selected and each slice was divided into 10-16 brain regions. Asymmetry indexes (AI) were analyzed in each brain region. We regarded over 10% changes of AI between before and after EA as significance. For the volunteers study, 10 healthy human volunteers (5 males, 5 females, mean age $28.1{\pm}6$ years old) were selected. In the resting state, $^{99m}Tc-ECD$ brain SPECT scans were performed. On the 7th day after the resting examination, 15 minute EA was applied at GB 34 and GB 39 on the right side of the subjects. Immediately after EA, the second SPECT images were obtained inthe same manner as the resting state. Significant increases and decreases of rCBF after EA were estimated by comparing their SPECT images with those of the resting state using paired t statistics at every voxel, which were analyzed by statistical parametric mapping with a threshold of p = 0.01, uncorrected (extent threshold: k=100 voxels). Results: In stroke patients, six of the eight (75%) had significantly increased perfusion in post-acupuncture scans compared to their baseline state. In normal volunteers, GB 34-GB GB EA increased rCBF in both hemispheres including right ventral posterior cingulate (Brodmann area (BA) 23), left superior temporal, anterior transverse temporal (BA 22, 41), left parastriate, peristriate (BA 18, 19), right occipitotemporal, angular (BA 37, 39), left rostral postcentral, caudal postcentral and preparietal (BA 2, 3, 5). However GB 34-GB 39 EA decreased rCBF in the right hemisphere including triangular and middle frontal lobes. Conclusions: The results demonstrated that OB 34-GB 39 EA increased cerebral perfusion in ischemic stroke patients and increased rCBF grossly in temporal lobes of normal volunteers. It is also suggested that there may be a correlation between the GB meridian and the territory of the middle cerebral artery.

  • PDF

저온온열치료에 의한 종양 내 저산소상태 개선효과를 $^18F$-Fluoromisonidazole의 섭취 변화를 이용한 평가 (Feasibility of Reflecting Improvement of Tumor Hypoxia by Mild Hyperthermia in Experimental Mouse Tumors with $^18F-Fluoromisonidazole$)

  • 이상욱;류진숙;오승준;임기천;천기정;이소령;송도영;임수정;문은숙;김종훈;안승도;신성수;이경룡
    • Radiation Oncology Journal
    • /
    • 제22권4호
    • /
    • pp.288-297
    • /
    • 2004
  • 목적: 종양 내에서 산소공급 부족현상으로 발생하는 저산소증 조직에서 저온온열치료($42^{circ}C$)와 nicotinamide에 의한 perfusion limited 저산소증의 개선 효과를 마우스 종양 모델을 이용하여 종양 내 $[^18F]FMISO$ 섭취변화를 이용하여 증명할 수 있는지 알아보고자 하였다. 대상 및 방법: C3H 마우스에 $[^18F]FMISO$를 정주하고 11개 장기에서 $\%ID/g$을 구하여 biodistribution을 관찰하였다. 또한 같은 마우스에 동종 종양세포인 SCC7을 이식하여 종양모델을 만들고 저온온열치료($42^{circ}C$)와 nico-tinamide를 투여한 마우스와 대조군 마우스에서 $[^18F]FMISO$의 섭취정도 차이를 $\%ID/g$, autoradiography, PET scan을 시행하여 비교하고자 하였다. 결과: 대조군에서 종양의 FMISO의 섭취는 5.1+/-2.28 $\%ID/g$였고, 종양/근육, 종양/혈액의 섭취비는 2.2와 1.8이었다. 실험군에서는 각각 2.4+/-0.64 $\%ID/g$, 1.4와 1.2를 나타내어 대조군보다 유의하게 낮았다(p<0.021). Autoradiography에서 대조군의 종양 내부에 FMISO가 섭취됨을 확인하였고, 저온온열치료와 nico-tinamide를 투여한 실험군에서는 섭취가 감소된 것을 관찰하였다. 결론: C3H 마우스와 동종 종양세포인 SCC-VII을 이용한 종양모델에서 $[^18F]FMISO$가 종양내에 섭취가 되어 자산소증 종양모델로 적절함을 확인하였고, 저온온열치료($42^{circ}C$)와 nicotinamide에 의한 perfusion limited 저산소증 개선효과를 $[^18F]FMISO$의 종양 내 섭취가 감소하는 것을 통하여 확인할 수 있었다.

검사 안내문의 시각적 디자인화가 환자의 검사 이해도 및 정확성에 미치는 영향 평가 (Evaluation of the influence of a visual design of an examination guide on patient comprehension and testing accuracy)

  • 강영은;정우영;홍보름
    • 핵의학기술
    • /
    • 제23권1호
    • /
    • pp.29-34
    • /
    • 2019
  • 본 연구는 기존 안내문에서 사용하고 있는 문어체의 글자와 배열, 형태 등을 시각적으로 디자인 및 재배치 함으로써 환자의 이해도 및 검사에 미치는 영향에 대해 평가 하였다. 서울아산병원 핵의학과 영상검사에서 가장 많은 비중을 차지하는 Bone Scan과 $^{201}Thallium$ Myocardium Perfusion SPECT의 Rest Scan 안내문을 개선 대상으로 선정하고, 원내 이노베이션센터와 협의하여 새롭게 디자인 하였다. 2016년 11월부터 2017년 2월은 기존의 안내문을, 2017년 3월부터 5월은 개선된 안내문을 사용하였으며, 개선 전후의 비교를 위해 해당 시기에 Bone Scan을 시행한 환자를 대상으로 안내문에 제시된 전처치 준수 및 그에 따른 영상의 질, 검사 소요시간을 측정하였고, $^{201}Thallium$ Myocardium Perfusion SPECT를 시행한 환자를 대상으로 안내문의 내용 이해에 대한 설문조사와 안내 후 재질문 하는 환자 및 질문유형, 안내문의 내용을 이행하지 않은 환자수를 분석하였다. 개선 후에는 Bone Scan은 전 처치가 미흡한 환자와 그로 인해 추가 영상이 필요한 환자가 감소하였고 평균 검사 소요시간은 안내문 개선 후 추가 영상 획득 시간의 감소로 약 2분 감소하였다. $^{201}Thallium$ Myocardium Perfusion SPECT의 경우 안내문의 내용 이해에 대한 5가지 문항에서 모두 이해도가 증가한 결과를 얻었으며, 검사 관련 재질문 하는 환자와 안내문의 내용을 이행하지 않은 환자 모두 감소하였다. 검사 안내문은 일방적이고 단순한 정보 제공이 아니라 환자 및 보호자와의 원활한 소통으로 이어지며, 영상품질과 업무 효율성을 향상시키고 나아가 검사 소요시간의 관리로 생산성 향상에도 도움을 줄 것으로 사료된다.

PET-CT 검사에서 방사선 종사자 피폭선량 저감에 대한 방안 연구 (A Study of Decrease Exposure Dose for the Radiotechnologist in PET/CT)

  • 김빛나;조석원;이주영;유광열;박훈희
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제38권1호
    • /
    • pp.23-30
    • /
    • 2015
  • 양전자 방출핵종은 511 keV의 감마선을 방출하기 때문에 기존 140 keV의 99mTc에 비해 종사자의 방사선 피폭의 증가로 피폭선량 저감을 위한 노력이 요구된다. 본 연구는 환자에게로부터 일정거리에 따른 선량률 변화를 확인하고 차폐를 이용하여 외부선량률의 변화를 알아보았으며 환자 주변의 외부선량 분포에 대한 영 향을 분석하여 방사선 종사자의 피폭 관리에 도움이 되고자 하였다. 10 명의 환자를 대상으로 하였으며 평균연령은 $47.7{\pm}6.6$ 세였다. 환자의 키는 평균 $165.5{\pm}3.8cm$, 몸 무게 평균은 $65.9{\pm}1.4kg$으로 비슷한 몸무게의 환자를 대상으로 하였다. 머리, 가슴, 복부, 무릎, 발끝 쪽의 위치에서 10 cm, 50 cm, 100 cm, 150 cm, 200 cm 위치에서 측정하였고 측정 후에 즉시 이동형 방사선 차폐체을 설치한 후 머리와 가슴, 복부 부분에서 100 cm, 150 cm, 200 cm 거리에서 선량률을 측정하였다. 거리에 따른 선량률 변화와 차폐 전, 후의 투과율을 구하였다. 평균 10 cm 거리에서는 머리 부분이 $105.40{\mu}Sv/h$로 가장 높게 나타났으며 발 부분에서 $15.85{\mu}Sv/h$로 가장 낮게 나타났다. 200 cm 거리에서는 머리, 가슴, 복부 부분에서 비슷한 선량률이 나타났다. 머리 부분에 서 차폐 전 100 cm에서 $9.56{\mu}Sv/h$, 150 cm에서 $5.23{\mu}Sv/h$, 200 cm에서 $3.40{\mu}Sv/h$로 나타났으며 차폐 후에는 100 cm, 150 cm, 200 cm 에서 각각 $2.24{\mu}Sv/h$, $1.67{\mu}Sv/h$, $1.27{\mu}Sv/h$로 측정되었다. 가슴 부분에 서 차폐 전 100 cm에서 $8.54{\mu}Sv/h$, 150 cm에서 $4.90{\mu}Sv/h$, 200 cm에서 $3.44{\mu}Sv/h$로 나타났으며 차폐 후에는 100 cm, 150 cm, 200 cm 에서 각각 $2.27{\mu}Sv/h$, $1.34{\mu}Sv/h$, $1.13{\mu}Sv/h$로 측정되었다. 복부 부분에 서 차폐 전 100 cm에서 $9.83{\mu}Sv/h$, 150 cm에서 $5.15{\mu}Sv/h$, 200 cm에서 $3.18{\mu}Sv/h$로 나타났으며 차폐 후에는 100 cm, 150 cm, 200 cm 에서 각각 $2.60{\mu}Sv/h$, $1.75{\mu}Sv/h$, $1.23{\mu}Sv/h$로 측정되었다. 투과율은 거리에 따라 증가함을 알 수 있었다. 거리가 멀어질수록 선량율이 낮아지는 것을 확인할 수 있었으며 차폐를 하였을 경우 차폐를 하지 않았을 때보다 1 / 4 정도 더 낮아지는 것을 확인할 수 있었다. 검사를 진행하는 근무자는 환자와의 거리를 멀리 할 수 없기 때문에 방사선 피폭이 증가할 수밖에 없다. 따라서 적절한 차폐를 한다면 방사선 종사자의 방사선 피폭을 줄 일 수 있을 것이다.

PET/CT 검사에서 방사선 종사자 피폭선량 저감에 대한 방안 연구 (A Study to Decrease Exposure Dose for the Radiotechnologist in PET/CT)

  • 조석원;박훈희;김정열;반영각;임한상;오기백;김재삼;이창호
    • 핵의학기술
    • /
    • 제14권2호
    • /
    • pp.159-165
    • /
    • 2010
  • 방사선 분야는 건강검진의 증가와 방사선 장치의 발달로 진단에서 치료까지 그 업무의 범위가 확대 및 급격히 증가하고 있으며 방사선 종사자의 방사선 피폭 관리가 중요하게 대두되고 있다. PET 검사에 이용되는 양전자 방출핵종은 511 keV의 감마선을 방출하기 때문에 종사자의 방사선 피폭의 증가로 피폭선량 저감을 위한 노력이 요구된다. 본 연구는 환자에게로부터 일정거리 외부선량률을 측정하고 거리에 따른 선량률 변화를 확인하고 차폐를 이용하여 외부선량률의 변화를 알아보았다. 2009년 12월부터 2010년 1월까지 PET/CT 검사를 위해 내원한 10명의 환자를 대상으로 하였다. Digital surveymeter를 이용하여 선량률을 측정하였다. 산란선에 대한 영향을 평가하기 위해서 이동식 방사선 차폐체를 설치하고 왼쪽, 중앙, 오른쪽 부분의 100 cm, 150 cm, 200 cm에서 총 12회 선량률을 측정하였다. 환자 선량률 측정은 $^{18}F$-FDG 5.18 MBq/kg을 주사하고 1시간이 지난 후에 선량이 안정되었을 때 즉시 1회를 측정하였다. 이동식 방사선 차폐체를 설치하기 전에 머리, 가슴, 복부, 무릎, 발끝 쪽의 위치에서 10 cm, 50 cm, 100 cm, 150 cm, 200 cm 위치로 총 80포인트에서 측정하였고 이동형 방사선 차폐체를 설치한 후 머리와 가슴, 복부 부분에서 100 cm, 150 cm, 200 cm 거리의 선량률을 측정하여 외부선량률을 확인하였다. 산란선 측정에 대해서는 위치별로 거리에 따라 분산분석을 시행하였다. 납 차폐를 하지 않았을 때와 차폐를 했을 때의 등선량곡선을 그렸으며 100 cm, 150 cm, 200 cm에 대하여 두 집단간에 상관분석을 시행하였다(SPSS ver. 12). 점 선원을 이용한 산란선 측정에서 100 cm, 150 cm, 200 cm에서는 p>0.05로 유의한 차이가 없었다. 거리가 멀어질수록 선량률이 낮아졌으며 머리 부분이 가장 높은 선량률이 나타났고 발 부분으로 갈수록 선량률이 떨어졌다. 또한 차폐를 하였을 경우 차폐를 하지 않았을 때보다 선량률이 낮아졌으며 100 cm에서 유의한 차이가 있었고(p<0.05) 150 cm, 200 cm에서는 유의한 차이가 없었다(p>0.05). 피폭을 줄이기 위해서는 방사선원에서 거리를 멀리하거나 적당한 차폐체를 이용하는 것이 피폭저감에 도움을 준다. 근무자의 동선을 파악하여 적당한 차폐체를 이용한다면 방사선 종사자의 방사선 피폭을 줄일 수 있을 것이다.

  • PDF

전신 뼈 검사에서 Wide Beam Reconstruction 기법의 유용성 (Utility of Wide Beam Reconstruction in Whole Body Bone Scan)

  • 김정열;강청구;박민수;박훈희;임한상;김재삼;이창호
    • 핵의학기술
    • /
    • 제14권1호
    • /
    • pp.83-89
    • /
    • 2010
  • UltraSPECT사의 Wide Beam Reconstruction (WBR)은 노이즈(Noise)와 조준기의 광속 확산 함수 효과(Beam spread function effect)를 제거하고 환자와의 거리를 자동적으로 보상하여 높은 해상도와 대조도를 제공할 수 있어 영상 획득 시간을 짧게 할 수 있고 상당한 영상 질 향상에 도움을 준다고 보고되고 있다. 이에 본 연구에서는 핵의학 분야에서 가장 흔히 이용되는 전신 뼈 스캔에 대해 WBR의 임상적 적용에 대한 유용성을 알아보고자 한다. XpressBone (WBR)의 성능 실험을 위하여 NEMA에서 제공하는 방법에 의하여 선원(Line source)과 SPECT Phantom을 이용하여 공간 분해능을 측정 분석하였다. 실험방법은 선원의 총 계수치를 200 kcps에서 300 kcps로 변화시켜 측정하였으며, SPECT Phantom은 매트릭스 크기를 변화시켜 측정하여 공간분해능에 대한 분석을 하였다. 또한 2009년 1월부터 2009년 9월까지 본원을 내원하여 뼈 스캔을 시행 받은 환자 40명을 두 군으로 나누어 임상 연구를 시행하였다. 1군은 $^{99m}Tc$-HDP 740 MBq (20mCi)를 투여하고 검사속도(20, 30 cm/min)를 변화시켰고, 2군은 동일한 검사속도에서 $^{99m}Tc$-HDP의 투여량을 변화시켜 영상을 획득하여 Standard data와 WBR기법으로 재구성한 영상을 비교 평가하였다. 분석방법은 대퇴골체부에서 뼈와 연부조직간 섭취비(Femur to tissue ratio: FTR)를 측정한 정량적인 분석과 핵의학과 전문의와 5년 이상의 실무경험을 가진 방사선사가 육안적인 분석을 하여 비교 평가하였다. 성능 실험에서 선원을 사용하여 실험한 결과 Planar WBR data는 Standard data에 비하여 분해능이 약 10% 향상되었으며, WBR 반치폭(Full-Width at Half-Maximum)은 16% 향상되었다(Standard data 8.45, WBR data 7.09). SPECT Phantom에서는 약 50%의 분해능이 향상되었으며, WBR 반치폭은 50% 향상되었다(Standard data 3.52, WBR data 1.65). 임상 연구에서는 $^{99m}Tc$-HDP 투여량을 고정시키고 검사속도를 20cm/min과 30 cm/min로 변화시킨 1군에서 Standard data와 WBR data의 전신 뼈 스캔 전면 영상에서 뼈 대비 연부조직간 섭취비는 통계적으로 유의한 차이를 보이지 않았다 (p=0.07). 검사속도를 고정하고 $^{99m}Tc$-HDP 투여량을 변화시킨 2군에서는 Standard data와 WBR data간의 전신 뼈 스캔전면 영상에서는 통계적으로 유의한 차이를 보이지 않았다 (p=0.458). 영상의 육안적 분석에서도 두 군 간 유의한 차이를 보이지 않았다(p>0.05). NEMA test 결과 WBR 기법의 영상에서 분해능이 향상되는 결과를 나타내었고, 임상 실험에서는 기존 재구성 방법에서의 동일한 해상도를 가지면서도 검사시간을 단축시킬 수 있었으며 방사성의약품의 투여량도 줄일 수 있었다. 이미 알려진 바와 같이 WBR은 노이즈를 감소시켜 신호 대 잡음비를 증강시키는 새로운 영상 재구성 방법임을 확인 할 수 있으며 동일한 검사속도에서 투여량을 감소시킬 수 있어 수신자의 피폭선량 경감과 검사시간을 단축할 수 있었으며 임상 현장에서 유용하게 이용되리라 사료된다.

  • PDF