• Title/Summary/Keyword: Gain-Loss method

Search Result 213, Processing Time 0.039 seconds

Dynamic Loudness Compensation for Digital Hearing Aids (디지탈 보청기의 이득보상기법에 대한 연구)

  • Kim, Dong-Wook;Kim, Won-Ky
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.11
    • /
    • pp.121-123
    • /
    • 1995
  • This paper presents a new method which compensates loss of loudness for digital hearing aids. Loudness grows more rapidly in frequency domain with substantial shifts of hearing threshold, so that loud sounds reach the uncomfortable sound level (UCL) at about the same physical stimulus level as with normal hearing. The result is a compression of the available dynamic range of hearing. Many techniques have been developed to compensate for hearing losses. In this paper, we propose a digital hearing aid which uses a single digital filter for reducing distortion and the fuzzy function to calculate gain factors. This function describes how much gain is needed for every frequency to restore loudness perception of a normal ear.

  • PDF

Effects of structural nonidealities on the lasing characteristics of $\lambda$/4 phase-shifted DFB lasers ($\lambda$/4 위상천이 DFB 레이저 다이도드에서 grating 구조상의 비이상성이 발진특성에 미치는 영향)

  • 조종섭;김상배
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.33A no.7
    • /
    • pp.245-252
    • /
    • 1996
  • $\lambda$/4 phase-shifted DFB lasers with nonideal grating structure have been studied by using an effective-index transfer matrix method where material dispersion, vwaveguide dispersion and waveguide-structuredependent loss are taken into consideration. Nonideal grating structure in the center phase-shift region does not incur serous degradation of laser characteristics. Phase-shift error from the ideal shift of $\pi$ causes a decrease in the threshold gain difference and lasing wavelength shift and should be less than $\pi$/4 when residual facet reflectivity is 0.7%. also, positional error of the phase-shift should be less than 9% of the cavity length in order for the threshold gain difference to be decreased less than 10%.

  • PDF

Oxidation Behavior of $SiC/MoSi_2$ Composites Prepared by Reaction Sintering Method (반응소결에 의하여 제조된 $SiC/MoSi_2$ 복합체의 산화 거동)

  • 양준환;한인섭;우상국;서동수
    • Journal of the Korean Ceramic Society
    • /
    • v.31 no.12
    • /
    • pp.1588-1598
    • /
    • 1994
  • The SiC/MoSi2 composite materials were fabricated by infiltrating the mixture of molybdenum disilicide and metal silicon(MoSi2+Si=100) to a porous compact of silicon carbide and graphite under the vacuum atmosphere of 10-1 torr. The specimen were oxidized in dry air under 1 atm at 130$0^{\circ}C$~150$0^{\circ}C$ for 240 hours. The oxidation behavior was evaluated by the weight gain and loss per unit area of the oxidized samples. Also, SEM and XRD analysis of the oxidized surface of the samples were carried out. With increasing the MoSi2 content and oxidation temperature, the passive oxidation was found. The trend of weight gain of all samples was followed the parabolic rate law with the formation of a protective layer of cristobalite on the surface.

  • PDF

A Study On The Microstrip Slot Array Antenna Design (마이크로스트립 슬롯 배열 안테나 설계에 관한 연구)

  • 한석진;박익모;신철재
    • Proceedings of the IEEK Conference
    • /
    • 1999.11a
    • /
    • pp.147-150
    • /
    • 1999
  • A T-shaped microstripline-fed printed slot array antenna having wide bandwidth, high gain, and narrow bandwidth is presented in this paper. The proposed antenna is analyzed by using the transmission line model method. We fabricated 4$\times$1 microstrip slot array antenna and measured its return loss and radiation pattern. The maximum bandwidth of this array antenna is from 1.43 ㎓ to 2.60 ㎓, which is 58.1% for the VSWR $\leq$ 2.

  • PDF

Design and Fabrication of the 4$\times$4 Microstrip array Antenna for Millimeter-wave (밀리미터파대 4$\times$4 마이크로스트립 배열 안테나 설계 및 제작)

  • 안성훈;문동권;안상철;박명렬;정천석
    • Proceedings of the IEEK Conference
    • /
    • 2003.07a
    • /
    • pp.605-608
    • /
    • 2003
  • In This paper, the 4$\times$4 microstrip patch array antenna for millimeter-wave is designed and fabricated. Before that, a patch antenna is designed to analyze the property in the millimeter-wave. Also, the excitation is implemented using edge and prove feeding. The array method is used to design the 2x1 array with corporate feeding network. Measured antenna shows 12.77 dBi gain, 37.65 GHz center frequency, -29.78 return loss and 680 MHz band width.

  • PDF

Weight Gain Study of Very Low Birth Weight Infants in Relation to Gestational Age and Birth Weight (출생시 체중과 재태기간에 따른 극소 저출생 체중아의 체중 변화)

  • Kim Hae-Soon;Shin Yeong-Hee
    • Child Health Nursing Research
    • /
    • v.10 no.1
    • /
    • pp.5-13
    • /
    • 2004
  • Purpose: The aim of this study was to analyze the correlation of gestational age and birth weight with weight gain of very low birth weight infants(VLBWI) during their hospital stay. Method: This is a 5 year retrospective study of which data were collected through review of medical records. Subjects were 124 VLBW infants with a birth weight more than 1000g and less than 1500g who received neonatal intensive care at the university hospital between January 1, 1997 to December 31, 2001. Result: After calculating the z scores of birth weights and discharge weights, z scores of discharge weight and birth weight were compared with the median weight of a fetus of comparable gestational age based on an intrauterine growth reference. There was a significant difference between z scores of birth weight and discharge weight(t=11.60, df=122, p=0.000). Regardless of intensive care during the prolonged hospital stay, VLBW infants showed slow growth rate compared with the median weight of a fetus of comparable gestational age. Conclusion: VLBW infants developed a poor velocity of weight gain during the prolonged hospital stay after birth. The development worsened during the period of physiological weight loss and regain, and they did not reach to comparable growth rate of normal fetus even at the time of discharge. This poor growth velocity of VLBW infants influence negatively for their future growth. Therefore nureses who work at the neonatal intensive care unit must develop an effective nursing intervention protocol to promote the velocity of weight gain and to conduct the parental educational sessions to emphasize the importance of weight gain for VLBW infants at home.

  • PDF

A Study on the Construal Level and Intention of Autonomous Driving Taxi According to Message Framing (해석수준과 메시지 프레이밍에 따른 자율주행택시의 사용의도에 관한 연구)

  • Yoon, Seong Jeong;Kim, Min Yong
    • Journal of Intelligence and Information Systems
    • /
    • v.24 no.3
    • /
    • pp.135-155
    • /
    • 2018
  • The purpose of this study is to analyze the difference of interpretation level and intention to use message framing when autonomous vehicle, which is emerging as the product of 4th industrial revolution, is used as taxi, Interpretation level refers to the interpretation of a product or service, assuming that it will happen in the near future or in the distant future. Message framing refers to the formation of positive or negative expressions or messages at the extremes of benefits and losses. In other words, previous studies interpret the value of a product or service differently according to these two concepts. The purpose of this study is to investigate whether there are differences in intention to use when two concepts are applied when an autonomous vehicle is launched as a taxi. The results are summarized as follows: First, the message format explaining the gain and why should be used when using the autonomous taxi in the message framing configuration, and the loss and how when the autonomous taxi is not used. Messages were constructed and compared. The two message framing differed (t = 3.063), and the message type describing the benefits and reasons showed a higher intention to use. In addition, the results according to interpretation level are summarized as follows. There was a difference in intentions to use when assuming that it would occur in the near future and in the near future with respect to the gain and loss, Respectively. In summary, in order to increase the intention of using autonomous taxis, it is concluded that messages should be given to people assuming positive messages (Gain) and what can happen in the distant future. In addition, this study will be able to utilize the research method in studying intention to use new technology. However, this study has the following limitations. First, it assumes message framing and time without user experience of autonomous taxi. This will be different from the actual experience of using an autonomous taxi in the future. Second, self-driving cars should technical progress is continuing, but laws and institutions must be established in order to commercialize it and build the infrastructure to operate the autonomous car. Considering this fact, the results of this study can not reflect a more realistic aspect. However, there is a practical limit to search for users with sufficient experience in new technologies such as autonomous vehicles. In fact, although the autonomous car to take advantage of the public transportation by taxi is now ready for the road infrastructure, and technical and legal public may not be willing to choose to not have enough knowledge to use the Autonomous cab. Therefore, the main purpose of this study is that by assuming that autonomous cars will be commercialized by taxi you can do to take advantage of the autonomous car, it is necessary to frame the message, why can most effectively be used to find how to deliver. In addition, the research methodology should be improved and future research should be done as follows. First, most students responded in this study. It is also true that it is difficult to generalize the hypotheses to be tested in this study. Therefore, in future studies, it would be reasonable to investigate the population of various distribution considering the age, area, occupation, education level, etc. Where autonomous taxi can be used rather than those who can drive. Second, it is desirable to construct various message framing of the questionnaire, but it is necessary to learn various message framing in advance and to prevent errors in response to the next message framing. Therefore, it is desirable to measure the message framing with a certain amount of time when the questionnaire is designed.

Intermittent Heating and Cooling Load Calculation Method -Comparing with ISO 13790

  • Lee, Sang-Hoon
    • Architectural research
    • /
    • v.14 no.1
    • /
    • pp.11-18
    • /
    • 2012
  • College of Architecture, Georgia Institute of Technology, Atlanta, GA, US Abstract The intermittent heating and cooling energy need calculation of the ISO 13790 monthly method was examined. The current ISO 13790 method applies a reduction factor to the continuous heating and cooling need calculation result to derive the intermittent heating and cooling for each month. This paper proposes a method for the intermittent energy need calculation based on the internal mean temperature calculation. The internal temperature calculation procedure was introduced considering the heat-balance taking into account of heat gain, heat loss, and thermal inertia for reduced heating and cooling period. Then, the calculated internal mean temperature was used for the intermittent heating and cooling energy need calculation. The calculation results from the proposed method were compared to the current ISO 13790 method and validated with a dynamic simulation using EnergyPlus. The study indicates that the intermittent heating and cooling energy need calculation method using the proposed model improves transparency of the current ISO 13790 method and draws more rational outcomes in the monthly heating and cooling energy need calculation.

A Parameter Selection Method for Multi-Element Resonant Converters with a Resonant Zero Point

  • Wang, Yifeng;Yang, Liang;Li, Guodong;Tu, Shijie
    • Journal of Power Electronics
    • /
    • v.18 no.2
    • /
    • pp.332-342
    • /
    • 2018
  • This paper proposes a parameter design method for multi-element resonant converters (MERCs) with a unique resonant zero point (RZP). This method is mainly composed of four steps. These steps include program filtration, loss comparison, 3D figure fine-tuning and priority compromise. It features easy implementation, effectiveness and universal applicability for almost all of the existing RZP-MERCs. Meanwhile, other design methods are always exclusive for a specific topology. In addition, a novel dual-CTL converter is also proposed here. It belongs to the RZP-MERC family and is designed in detail to explain the process of parameter selection. The performance of the proposed method is verified experimentally on a 500W prototype. The obtained results indicate that with the selected parameters, an extensive dc voltage gain is obtained. It also possesses over-current protection and minimal switching loss. The designed converter achieves high efficiencies among wide load ranges, and the peak efficiency reaches 96.9%.

A Study on the Microstrip Patch Antenna Using FDTD Method (유한 차분 시간법을 이용한 마이크로스트립 패치 안테나에 관한 연구)

  • 장용웅;박상규;신철재
    • Journal of Broadcast Engineering
    • /
    • v.2 no.1
    • /
    • pp.1-7
    • /
    • 1997
  • In this paper, a microstrip patch antenna was analyzed by using FDTD method. Firstly, the electric field in the microstrip patch antenna was obtained by approximating a Maxwell's equation to a finite difference equation by means of Yee's algorithm. In this case, Mur's 1st approximation and dispersive boundary condition(BBC) were applied to an absorbing boundary condition. We also analyzed a single microstrip patch antenna by using the FDTD method, then calculating the propagative process in the wave of a return loss. Also, as the result that FDTD was applied to 2-array antenna designed to increase the gain of antenna, the measured results was in relatively good accordance with the values calculated by the FDTD method. The calculated impedance, return loss and VSWR were comparatively good. And these results were In relatively good accordance with the measured values.

  • PDF