• Title/Summary/Keyword: GS5

Search Result 454, Processing Time 0.03 seconds

Inhibition of Human Leukocyte Cathepsin G by NSAIDs (Non-Steroidal Anti-Inflammatory Drugs) (NSAIDs (Non-Steroidal Anti-Inflammatory Drugs)에 의한 사람 중성구 Cathepsin G의 활성도 억제)

  • Bae, Sung-Jun;Ghim, Sa-Youl;Kang, Koo-Il
    • The Korean Journal of Pharmacology
    • /
    • v.26 no.1
    • /
    • pp.51-54
    • /
    • 1990
  • Human leukocyte cathepsin-Gs are active participant in the active phase of inflammations like rheumatoid arthritis, emphysema and glomerular injury. Non-steroidal anti-inflammatory drugs (NSAIDs) are widely used for treatment of these inflammatory diseases. Mechanism of action of NSAIDs for treatment of inflammatory diseases, especially like rheumatoid arthritis, are known as the inhibitors of prostaglandin synthesis. Inhibitions of the activities of human leukocyte cathepsin-Gs by non-steroidal anti-inflammatory drugs, however, were not same as the known pharmacological effects (inhibition of cyclooxygenase) of these drugs. Among them, especially, sulindac, salicylate, phenylbutazone, oxyphenbutazone, and salicyluric acid inhibited human leukocyte cathepsin-Gs effectively. $IC_{50}s$ of each drug were 4.3mM, 14.3mM, 6.5mM, 11mM and 15mM respectively. The drugs which have same chemical structure and same degree of inhibition effect on cyclooxygenase showed different degree or no effect on inhibition of cathepsin G. These inhibition effect might be, beside of inhibition of cyclooxygenase in the prostaglandin synthesis pathway, another benefitial antiinflammatory effect of NSAIDs by direct protection against tissue destruction in inflammatory diseases.

  • PDF

Study on the Flare Load Estimation of the Deethanizer using Dynamic Simulation (동적 모사를 이용한 에탄 분리탑의 플레어 용량 예측에 관한 연구)

  • Park, Kyungtae;Won, Wangyun;Shin, Dongil
    • Korean Chemical Engineering Research
    • /
    • v.52 no.5
    • /
    • pp.613-619
    • /
    • 2014
  • A flare system is a very important system that crucially affects on the process safety in chemical plants. If a flare system is designed too small, it cannot prevent catastrophic accidents of a chemical plant. On the other hand, if a flare system is designed too large, it will waste resources. Therefore, reasonable relief load estimation has been a crucial issue in the industry. American Petroleum Institute (API) suggests basic guidelines for relief load estimation, and a lot of engineering companies have developed their own relief load estimation methods that use an unbalanced heat and material method. However, these methods have to involve lots of conservative assumptions that lead to an overestimation of relief loads. In this study, the new design procedure for a flare system based on dynamic simulation was proposed in order to avoid the overestimation of relief loads. The relief load of a deethanizer process was tested to verify the performance of the proposed design procedure.

Case Studies for Optimizing Energy Efficiency of Propane Cycle Pressure Levels on C3-MR Process (C3-MR 공정의 프로판 사이클 압력 레벨에 따른 에너지효율 최적화를 위한 사례연구)

  • Lee, In-Kyu;Tak, Kyung-Jae;Lim, Won-Sub;Moon, Il;Kim, Hak-Sung;Choi, Kwang-Ho
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.6
    • /
    • pp.38-43
    • /
    • 2011
  • Natural gas liquefaction process runs under cryogenic condition, and it spends large amount of energy. Minimizing energy consumption of natural gas liquefaction process is an important issue because of its physical characteristics. Among many kinds of natural gas liquefaction processes, C3-MR(Propane Pre-cooled Mixed Refrigerant) process uses two kind of refrigerants. One is the propane as the pure refrigerant(PR) and the other is the mixed refrigerant(MR). In this study, to find the optimal compressing level, propane cycle is simulated on different pressure level. The case study result shows relationship between energy consumption and pressure level. As a result, the conclusion is that at a higher pressure level, process consumes lower energy. At 5 pressure-levels, energy consumption is 23.7% lower than 3 pressure-levels.

Electrical Characteristics of Ambipolar Thin Film Transistor Depending on Gate Insulators (게이트 절연특성에 의존하는 양방향성 박막 트랜지스터의 동작특성)

  • Oh, Teresa
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.5
    • /
    • pp.1149-1154
    • /
    • 2014
  • To observe the tunneling phenomenon of oxide semiconductor transistor, The Indium-gallum-zinc-oxide thin film transistors deposited on SiOC as a gate insulator was prepared. The interface characteristics between a dielectric and channel were changed in according to the properties of SiOC dielectric materials. The transfer characteristics of a drain-source current ($I_{DS}$) and gate-source voltage ($V_{GS}$) showed the ambipolar or unipolar features according to the Schottky or Ohmic contacts. The ambipolar transfer characteristics was obtained at a transistor with Schottky contact in a range of ${\pm}1V$ bias voltage. However, the unipolar transfer characteristics was shown in a transistor with Ohmic contact by the electron trapping conduction. Moreover, it was improved the on/off switching in a ambipolar transistor by the tunneling phenomenon.

Process Modeling System of a Combined Cycle Plant for Steady State Simulation with Model Based Approach (수학적 모델링 방법에 기초한 복합발전 공정의 정상상태 모사시스템 개발)

  • Kim, Shin Hyuk;Hwang, Lee Si;Joo, Yong Jin;Lee, Sang Uk;Shon, Byung Mo;Oh, Min
    • Korean Chemical Engineering Research
    • /
    • v.53 no.5
    • /
    • pp.545-552
    • /
    • 2015
  • Process modeling and simulation is a powerful methodology to quantitatively predict the change of process variables when operating and design conditions are changed. In this study, considering drawbacks of currently used process simulator for combined cycle plants, we developed process modeling system equipped with an ease of use and flexibility for model development. For this purpose, the analysis of combined cycle processes was carried out and consequently, mathematical models and libraries were developed. Furthermore, in view of the fact that the level of the abstraction of process models depends on the purpose of simulation as well as the available data, simple and rigorous models were also developed for some important units. In use of reference combined plant, we executed process simulation using the developed modeling system and the comparison was made between the results of simulation and the reference data. Less than 1% marginal error was identified and we concluded that the modeling system can be applied for commercial combined cycle processes.

An Investigation on the Flow Characteristics of Water Spray Nozzle (미세 물분무 노즐의 유동특성에 관한 연구)

  • Jun, You Woo;Han, Young Tak;Kim, Chang Seob;Kim, Chang;Ryou, Hong-Sun
    • Fire Science and Engineering
    • /
    • v.29 no.5
    • /
    • pp.29-33
    • /
    • 2015
  • In this study, the relations of flow rate, discharging distance and droplet size are measured in accordance with the nozzle shape. The dual type nozzles of LPN142 and LPN148, which have identical core diameter (6.0 mm) and the different radial injection angles (${\theta}_2=142^{\circ}$ and $148^{\circ}$), are manufactured. The distribution diameters with discharging distance are quantified by UL2167 test standard. The relations between discharging angle and droplet sizes, which are measured by the method of Helium-Neon laser equipment, are obtained by the empirical correlation as working pressure increase. Moreover, the extinction coefficient, which is major parameter of the radiative transport equation (RTE) is analyzed with variable droplet sizes. Thus, it is possible to opt the nozzle's shape by analyzing the relations of working pressure, spray distance, droplet size and fire characteristics at minimum allowable flow rate.

재래산양에 있어서 난포란의 활성화 처리방법이 체외발달에 미치는 영향

  • 박희성;이명열;김현정;권병철;이윤희;박준규;정장용
    • Proceedings of the KSAR Conference
    • /
    • 2003.06a
    • /
    • pp.68-68
    • /
    • 2003
  • 오늘날 형질전환동물의 생산과 같은 생명공학기술의 발달로 인하여 우리나라 재래산양은 그 모델동물로서 번식 생리학적으로 매우 중요한 가치를 지니고 있을 뿐만 아니라 고유의 유전자원 보존 측면에서도 산양복제와 같은 다양한 연구가 절실히 요구된다. 따라서 본 연구에서는 이러한 생명공학기술의 기초자료를 제공하고자 난포란의 활성화 방법과 단위발생란의 체외발달율을 조사하였다. 성숙한 미경산 재래산양을 공시동물로 하여 CIDR를 이용하여 발정동기화를 시켰으며, 과배란 처리는 FSH와 hCG를 이용하여 과배란 처리를 실시하였고 난포란의 회수는 외과적 방법으로 개복하여 난소의 난포로부터 난자와 난포액을 흡입하여 회수하였다 난포란의 활성화 처리는 전기자극법과 약물처리 방법을 사용하였으며, 전기자극방법은 DC 2.36㎸/cm, 17$\mu$sec 전압으로 1회 전기자극을 가하여 활성화를 유도하였으며, 약물처리법은 5$\mu\textrm{g}$/$m\ell$의 ionomycin 용액에서 5min, 1.9mM 6-DMAP용액에서 4시간동안 처리하여 활성화를 유도하였다. 단위발생란의 배양은 10% GS(goat serum)가 첨가된 M16 배양액과 10% FBS가 첨가된 TCM-199 배양액에서 난관상피세포와 6~7일동안 공배양을 실시하면서 체외발달율을 조사하였다. 활성화 방법에 따른 체외발달율은 전기자극 및 약물처리를 하였을때 분할율은 3.1% 및 67.9%였으며, 상실배 및 배반포로의 발달율은 0% 및 7.9%였다. 단위발생란의 체외 발달율은 10% GS가 첨가된 M16 배양액을 사용하였을 때 분할율은 68.0%였으며, 이중 12.0%가 상실배 또는 배반포로 발달하였다. 뿐만 아니라 10% FBS가 첨가된 TCM-199 배양액에 난관상피세포와 공배양을 실시하였을 경우는 72.0%가 분할하였으며, 이중 16.7%가 상실배 또는 배반포로 발달하였다. 이상의 결과로 볼 때 활성화 처리는 ionomycin과 6-DMAP 용액처리가 적합하며, 단위발생란의 체외배양은 보다 적합한 배양조건의 확립이 필요한 것으로 생각된다.

  • PDF

The Physical and Shear Strength Properties of the Weathered Limestone Soils in Changsung and Hwasun Area of Chonnam Province, Korea (전라남도 장성과 화순에 분포하는 석회암풍화토의 물성 및 전단 특성)

  • 김해경
    • The Journal of Engineering Geology
    • /
    • v.13 no.3
    • /
    • pp.335-344
    • /
    • 2003
  • This study is focused to the physical and shear strength properties of the weathered limestone soils distributed in Changsung and Hwasun area, Chonnam province. Disturbed soil was used as soil samples. To grasp the physical and shear strength properties of weathered limestone soil, specific gravity test, atterberg limit, grain size distribution and direct shear test were conducted in the laboratory. The physical and shear strength properties of the weathered limestone soil in the study areas are as follows. The range of specific gravity (Gs) is 2.78 to 2.80, liquid limits (LL) 37 to 38 (%), plasticity index (PI) 13.7 to 15.4, and soil classification CL. The range of strength parameters by direct shear test (vd, $1.5t/\textrm{m}^3$) is 3.07 to 4.4 ($t/\textrm{m}^2$) of cohesion and 34.8 to $42.4^{\circ}$ of internal friction angle in unsaturated soils. As a result of comparing with the weathered granite soils (Yang, 1997: Mun, 1998: Park, 1998), it is considered that physical properties of the weathered limestone soils in this study are different from the weathered granite soils. On the other hand, internal friction angle of shear parameters is found to be similar.

Analysis of Instability Mechanism under Simultaneous Positive Gate and Drain Bias Stress in Self-Aligned Top-Gate Amorphous Indium-Zinc-Oxide Thin-Film Transistors

  • Kim, Jonghwa;Choi, Sungju;Jang, Jaeman;Jang, Jun Tae;Kim, Jungmok;Choi, Sung-Jin;Kim, Dong Myong;Kim, Dae Hwan
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.15 no.5
    • /
    • pp.526-532
    • /
    • 2015
  • We quantitatively investigated instability mechanisms under simultaneous positive gate and drain bias stress (SPGDBS) in self-aligned top-gate amorphous indium-zinc-oxide thin-film transistors. After SPGDBS ($V_{GS}=13V$and $V_{DS}=13V$), the parallel shift of the transfer curve into a negative $V_{GS}$ direction and the increase of on current were observed. In order to quantitatively analyze mechanisms of the SPGDBS-induced negative shift of threshold voltage (${\Delta}V_T$), we experimentally extracted the density-of-state, and then analyzed by comparing and combining measurement data and TCAD simulation. As results, 19% and 81% of ${\Delta}V_T$ were taken to the donor-state creation and the hole trapping, respectively. This donor-state seems to be doubly ionized oxygen vacancy ($V{_O}^{2+}$). In addition, it was also confirmed that the wider channel width corresponds with more negative ${\Delta}V_T$. It means that both the donor-state creation and hole trapping can be enhanced due to the increase in self-heating as the width becomes wider. Lastly, all analyzed results were verified by reproducing transfer curves through TCAD simulation.

Screw Joint Stability under Cyclic Loading of Zirconia Implant Abutments (지르코늄 임플란트 지대주의 나사결합부 안정성에 관한 연구)

  • Lee, Mi-Soon;Suh, Kyu-Won;Ryu, Jae-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.164-173
    • /
    • 2009
  • Purpose: The purpose of this study was to evaluate the effect of abutment material on screw-loosening before and after cyclic loading. Among the different materials of abutments, zirconia and metal abutment were used. Material and methods: Two types of implant systems: external butt joint(US II, Osstem Implant, Korea) and internal conical joint(GS II, Osstem Implant, Korea) were used. In each type, specimens were divided into two different kinds of abutments: zirconia and metal(n=5). The implant was rigidly held in a special holding to device ensure fixation. Abutment was connected to 30 Ncm with digital torque gauge, and was retightened in 30 Ncm after 10 minutes. The initial removal torque values were measured. The same specimens were tightened in 30 Ncm again and held in the cycling loading simulator(Instron, USA) according to ISO/FPIS 1480. Cycling loading tests were performed at loads 10 to 250 N, for 1 million cycles, at 14 Hz,(by subjecting sinusoidal wave from 10 to 250 N at a frequency of 14 Hz for 1 million cycles,) and then postload removal torque values were evaluated. Results: 1. In all samples, the removal values of abutment screw were lower than tightening torque values(30 Ncm), but the phenomenon of the screw loosening was not observed. 2. In both of the implant systems, initial and postload removal torque of zirconia abutment were significantly higher than those of metal abutment(P<.05). 3. In both of the implant systems, the difference in removal torque ratio between zirconia abutment and metal abutment was not significant(P>.05). 4. In metal abutments, the removal torque ratio of GS II system(internal conical joint system) was lower than that of US II system(external butt joint system)(P<.05). 5. In zirconia abutments, the difference in removal torque ratio between the two implant systems was not significant(P>.05). Conclusion: Zirconia abutment had a good screw joint stability in the condition of one million cycling loading.