• Title/Summary/Keyword: GB25

Search Result 193, Processing Time 0.027 seconds

A 1.25Gb/s Burst-mode Optical Transmitter with Digitally Controlled APC (디지털 제어 방식의 APC 기능을 갖는 1.25Gb/s 버스트-모드 광 송신기)

  • Ki, Hyeon-Cheol
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.12
    • /
    • pp.25-30
    • /
    • 2007
  • In this paper, we proposed a new burst-mode optical transmitter structure which is suitable for high data rate operation such as Gb/s operation. With this structure we made a 1.25Gb/s burst-mode optical transmitter including a digitally controlled APC circuit for EPON systems using commercial 0.8m BiCMOS technology. It well functioned at 1.25Gb/s and showed good eye patterns with 53.3ps jitter, 191ps rise time and 258ps fall time. To characterize the APC function we measured optical output power as increasing external voltage VREF. The optical power is linearlyproportional to VREF at the rate of 0.293mW/V.

A study on acupoints and muscles used for cosmetic acupuncture (미용침(cosmetic acupuncture)에 응용되는 경혈과 근육에 대한 고찰)

  • Yang, Mi-Sung;Shin, Mi-Sook
    • Korean Journal of Acupuncture
    • /
    • v.26 no.3
    • /
    • pp.13-25
    • /
    • 2009
  • Objectives : This study was performed to investigate acupoints and muscles used for cosmetic acupuncture. We want most clinicians practicing cosmetic acupuncture to understand theoretical background well and to treat cosmetic diseases more diversely by this paper. Methods : We collected useful informations from some books and websites about cosmetic acupuncture and thus could select major acupoints and muscles. Conculsions : The most frequently used acupoints for cosmetic acupoints are as follows ; LI20, ST1, ST2, ST3, ST4, ST5, ST6, ST7, ST8, SI18, SI19, BL1, BL2, BL3, BL4, TE17, TE18, TE19, TE20, TE21, TE22, TE23, GB1, GB2, GB3, GB4, GB5, GB6, GB7, GB8, GB13, GB14, GV20, GV21, GV22, GV23, GV24, GV25, GV26 and CV24. And head and neck muscles including SCM muscle, plastyma, frontalis, corrugator supercilii, orbicularis oculi, auricularis, temporalis, masseter, pterygoid, zygomaticus and risorius can be used for cosmetic acupuncture. Most acupoints and muscles are located in face and head, which seemed to be concerned with formation of face wrinkles.

  • PDF

Review on the change of acupuncture point location of gallbladder meridian in head (담경(膽經)의 두경부(頭頸部) 혈위(穴位) 변천(變遷)에 대한 문헌적(文獻的) 고찰(考察))

  • An, Young-Sang;Yang, Ki-Young;Lee, Byung-Ryul;Yim, Yun-Kyoung
    • Korean Journal of Acupuncture
    • /
    • v.25 no.4
    • /
    • pp.49-58
    • /
    • 2008
  • Objectives and Methods : The present study was to investigate the change of acupuncture point location of gallbladder meridian in head by way of reviewing classical literatures. Result and Conclusions : 1. The locations of acupuncture points closed-by anatomical marks such as GB1, GB2, GB3, GB11, GB12, GB19, GB20 are clear and accurate. 2. The expression of acupuncture points' locations of GB4, GB5, GB6, GB8 and GB10 are obscure in classical literature, but their locations became clear and objective in recent literatures. 3. The locations of GB9 and GB13 are open to dispute but WHO standard acupuncture point seems to be resonable. 4. In classical literature, the length from the midpoint of the anterior hairline to the midpoint of the posterior hairline is 12 B-cun, and the length from the midpoint of the anterior hairline to the GB19 is 5 cun, 5.5 cun or 6.5 cun. We presume that the length from GB15 to GB19 might have been measured by F-cun.

  • PDF

Localization of Motor and Sensory Neurons Innervating Kidney, Shinsu(BL23) and Kyongmun(GB25) in the Rat (흰쥐의 신장(腎臟) 신유(腎兪) 경문(京門)을 지배하는 운동(運動)과 감각신경세포체(感覺神經細胞體)에 대한 연구(硏究))

  • Ryu, Suk-Hyun;Lee, Chang-Hyeon;Lee, Sang-Ryong
    • The Journal of Korean Medicine
    • /
    • v.18 no.1
    • /
    • pp.385-398
    • /
    • 1997
  • The location and local arrangement of motor, sensory neurons within brain stem, nodose ganglia, spinal ganglia and sympathetic ganglia projecting to rat's kidney and meridian point BL 23, GB 25 were investigated by HRP immunohistochemical methods following injection of 5% WGA-HRP into left kidney and meridian point BL 23, GB 25. Following injection of WGA-HRP into left kidney, anterogradely labelled sensory neurons were founded within either nodose ganglia and spinal ganglia. The sensory neurons innervating rat's left kidney were observed within spinal ganglia $T_{7}{\sim}L_3$. Sympathetic motor neurons innervating rat's left kidney were labelled within left suprarenal ganglia, either celiac ganglia, superior mesenteric ganglia, and sympathetic chain ganglia $T_{1}{\sim}L_3$. Sympathetic chain ganglia were concentrated in $T_{12}{\sim}L_1$. The sensory neurons innervating rat's meridian point BL 23 were founded within spinal ganglia $T_{2}{\sim}L_2$. They were numerous in spinal in ganglia $T_{10}{\sim}T_{12}$. Sympathetic motor neurons innervating rat's meridian point BL 23 were observed in suprarenal ganglia and greater splanchnic trunk, sympathetic chain ganglia from $T_1$ to $L_3$. They were concentrated in $T_{12}{\sim}L_3$. The sensory neurons innervating rat's meridian point GB 25 were labelled within spinal ganglia $T_{6}{\sim}T_{13}$. They were numerous in from T10 to $T_{12}$. Sympathetic motor neurons innervating rat's meridian point GB 25 were labelled within greater splanchnic trunk and sympathetic chain ganglia $T_{12}{\sim}L_3$. They were concentrated in $T_{13}{\sim}L_1$. This results neuroanatomically imply that the location of rat's motor and sensory neurons innervating meridian point BL 23 and GB 25 were closely related that of innervating kidney.

  • PDF

A 2.5Gb/s 2:1 Multiplexer Design Using Inductive Peaking in $0.18{\mu}m$ CMOS Technology (Micro spiral inductor를 이용한 2.5Gb/s급 2:1 Multiplexer 설계)

  • Kim, Sun-Jung;Choi, Jung-Myung;Burm, Jin-Wook
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.8
    • /
    • pp.22-29
    • /
    • 2007
  • A 2.5Gb/s 2:1 multiplexer(MUX) IC using $0.18{\mu}m$ CMOS was designed and fabricated. Inductive peaking technology was used to improve the performance. On-chip micro spiral inductor was designed to maximize the inductive peaking effect without increasing the chip area much. The designed 4.7 nH micro-spiral inductor was $20\times20{\mu}m2$ in size. 2:1 MUX with and without micro spiral inductors were compared. The rise and fall time was improved more than 23% and 3% respectively using the micro spiral inductors for 1.25Gb/s signal. For 2.5 Gb/s signal, fall and rise time was improved 5.3% and 3.5% respectively. It consumed 61mW and voltage output swing was 1$180mV_{p-p}$ at 2.5Gb/s.

1.485Gb/s Tranceiver Design for HDTV Camera System using 0.25um CMOS Process (0.25um CMOS를 이용한 고해상도 TV용 1.485Gb/s 직/병렬화기의 설계)

  • Ryoo, Ji-Yeoul;Hong, Young-Uk;Choi, Bae-Kun;Cho, Gyu-Hyung
    • Proceedings of the KIEE Conference
    • /
    • 1999.11c
    • /
    • pp.736-738
    • /
    • 1999
  • 본 논문은 HDTV camera에 응용할 수 있는 직/병렬화기에 관한 것이다. 송신단은 camera에서 만들어진 영상 음성 및 제어 74.25Mb/s 20bit 병렬 데이터를 1.485Gb/s의 직렬 데이터로 변환하여 송신하고 수신단은 수신된 직렬 데이터에서 클럭을 추출한 뒤 원래의 74.25Mb/s 20bit 병렬 데이터로 복원한다. 0.25um CMOS공정을 이용하여 설계하였으며 2.5V 단일 전원에서 총 615mW의 전력을 소모한다.

  • PDF

Preliminary Results of Polarimetric Characteristics for C-band Quad-Polarization GB-SAR Images Using H/A/$\alpha$ Polarimetric Decomposition Theorem

  • Kang, Moon-Kyung;Kim, Kwang-Eun;Lee, Hoon-Yol;Cho, Seong-Jun;Lee, Jae-Hee
    • Korean Journal of Remote Sensing
    • /
    • v.25 no.6
    • /
    • pp.531-546
    • /
    • 2009
  • The main objective of this study is to analyse the polarimetric characteristics of the various terrain targets by ground-based polarimetric SAR system and to confirm the compatible and effective polarimetric analysis method to reveal the polarization properties of different terrain targets by the GB-SAR. The fully polarimetric GB-SAR data with HH, HV, VH, and VV components were focused using the Deramp-FFT (DF) algorithm. The focused GB-SAR images were processed by the H/A/$\alpha$ polarimetric decomposition and the combined H/$\alpha$ or H/A/$\alpha$ and Wishart classification method. The segmented image and distribution graphs in H/$\alpha$ plane using Cloude and Pottier's method showed a reliable result that this quad-polarization GB-SAR data could be useful to classified corresponding scattering mechanism. The H/$\alpha$-Wishart and H/A/$\alpha$-Wishart classification results showed that a natural media and an artificial target were discriminated by the combined classification, in particular, after applying multi-looking and the Lee refined speckle filter.

Combined Application of Pseudomonas fluorescens and Trichoderma viride has an Improved Biocontrol Activity Against Stem Rot in Groundnut

  • Manjula, K.;Kishore, G.Krishna;Girish, A.G.;Singh, S.D.
    • The Plant Pathology Journal
    • /
    • v.20 no.1
    • /
    • pp.75-80
    • /
    • 2004
  • In an attempt to develop effective biocontrol system for management of stem rot disease in groundnut, 57 bacterial isolates and 13 isolates of Trichoderma spp. were evaluated for their antagonistic activity against Sclerotium rolfsii. The antagonists were selected based on their ability to inhibit the external growth of S. rolfsii from infected groundnut seeds. Four isolates of Pseudomonas fluorescens, GB 4, GB 8, GB 10 and GB 27, and T. viride pq 1 were identified as potent antagonists of S. rolfsii. T. viride pq 1 produced extracellular chitinase and parasitized the mycelium of S. rolfsii. Under controlled environment conditions, P. fluorescens GB 10, GB 27, T. viride pq 1 and the systemic fungicide Thiram(equation omitted) reduced the mortality of S. rolfsii inoculated to groundnut seedlings by 58.0%, 55.9%, 70.0% and 25.9%, respectively compared to control. In vitro growth of P. fluorescens GB 10 and GB 27 was compatible with T. viride pq 1 and Thiram(equation omitted). Integrated use of these two bacterial isolates with T. viride pq 1 or Thiram(equation omitted) improved their biocontrol efficacy. Combined application of either GB 10 or GB 27 with T. viride pq 1 was significantly effective than that with Thiram(equation omitted) in protecting groundnut seedlings from stem rot infection.

Compact 2.5 Gb/s Burst-Mode Receiver with Optimum APD Gain for XG-PON1 and GPON Applications

  • Kim, Jong-Deog;Le, Quan;Lee, Mun-Seob;Yoo, Hark;Lee, Dong-Soo;Park, Chang-Soo
    • ETRI Journal
    • /
    • v.31 no.5
    • /
    • pp.622-624
    • /
    • 2009
  • This letter presents a compact 2.5 Gb/s burst-mode receiver using the first reported monolithic amplifier IC developed with 0.25 ${\mu}m$ SiGe BiCMOS technology. With optimum avalanche photodiode gain, the receiver module can obtain a fast response, high sensitivity and wide dynamic range, satisfying the overhead timing and various power specifications for a 2.5 Gb/s next-generation passive optical network (PON), as well as a legacy 1.25 Gb/s PON in the upstream.

Eye margin characteristics of 10Gb/s signals to the variation of optical signal to noise ratio and dispersion compensation (10 Gb/s 신호의 광학적 신호대 잡음비와 색분산 보상에 따른 아이 마진 특성)

  • 이상수;한정희;이동호;주무정;김민규
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.2
    • /
    • pp.169-173
    • /
    • 1999
  • We have experimentally investigated the eye margin characteristics of intensity modulated 10Gb/s NRZ signals in optically amplified systems depending on optical signal-to-noise ratio and chromatic dispersion. For the practical system application, the minimum optical signal-to-noise ratio was 25 dB. We utilized the negative chirped transmitter and a dispersion compensation fiber to compensate the chromatic dispersion in single mode fiber. We found the optimum eye opening and receiver sensitivity in case of the residual dispersion of 0~+935 ps/nm.

  • PDF