• Title/Summary/Keyword: G-power

Search Result 4,956, Processing Time 0.03 seconds

A Technique for Accurate Measurement of Power System Frequency (전력설비의 정밀주파수진단을 위한 기법)

  • Nam, S.B.;Lee, H.G.
    • Proceedings of the KIEE Conference
    • /
    • 2006.05a
    • /
    • pp.66-70
    • /
    • 2006
  • Frequency is an important operating parameter of a power system. Electric power systems sustain transient frequency swings whenever the balance between generation and load does not no longer hold. To cope with this Constraints, il requires an accurate and high speedy frequency deviation estimation technique and suitable adjustment to obtain the power system energy balance. This paper describes the design, computational aspects and implementation of an iterative technique for measuring power system. The rate change of the phase angle is used for estimation. To confirm the validity of the proposed algorithm, the simulation studies carried out on a typical 154[KV] double T/L system by using EMTP software. Some test results are presented in the paper.

  • PDF

Development of on-line system using electromagnetic wave for diagnosis of deteriorated power equipment (전자파 검출에 의한 전력기기 On-Line 열화 측정시스템 개발)

  • Kang, C.W.;Choi, G.S.;Lee, Y.S.;Kim, C.W.;Kang, D.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1664-1666
    • /
    • 2001
  • This paper presents the development of electromagnetic wave detecting equipment for diagnosis of enclosed switchboard. High voltage power equipments are very important equipment of the key industries and the private enterprise. Power line accidents are national plans because of those set off casualties lose of power equipments and communication networks. Therefore the necessity of the development of detecting for power equipment diagnosis is demand for prevention of high voltage equipment accidents. This paper is the development of electromagnetic wave detecting equipment for diagnosis of high voltage equipment. This paper establishes the diagnosis method for high voltage power equipments, that secures original technique and possesses detecting technique for electromagnetic wave. By the study we developed electromagnetic wave detector, and we applied this equipment application tests at the place constructed high voltage equipments.

  • PDF

Development of discharge lamp ballast for wave improvement (파형개선을 위한 방전등 안정기 개발)

  • Lee, O.K.;Song, D.S.;Kim, T.W.;Lee, J.T.;Song, H.S.;Kim, J.G.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07e
    • /
    • pp.85-88
    • /
    • 2000
  • This paper was development a discharge lamp ballast in order to wave improvement of high power factor and high efficiency. The discharge lamp ballast consists of a power factor correction circuit and a correction circuit on switching frequency of inverter. Instead of passive power factor circuit, active power factor circuit is adopted. Because it has the advantage of size, weight, total harmonic distortion, out DC voltage regulation, and power factor. The power factor circuit with MG34262 is controlled by variable frequency discontinuous mode. Results experiments, discharge lamp ballast is showed to have excellent for the proposed electronic ballast's operation and characteristics.

  • PDF

A Technique for Fast and Accurate Measurement of Power System Frequency (전력계통 주파수의 고속.정밀측정을 위한 기법)

  • Nam, S.B.;Lee, H.G.;Ma, S.B.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07e
    • /
    • pp.68-71
    • /
    • 2004
  • Frequency is an important operating parameter of a power system. Electric power systems sustain transient frequency swings whenever the balance between generation and load does not no longer hold. To cope with this Constraints, it requires an accurate and high speedy frequency deviation estimation technique and suitable adjustment to obtain the power system energy balance. This paper describes the design, computational aspects and implementation of an iterative technique for measuring power system. The rate change of the phase angle is used for estimation. To confirm the validity of the proposed algorithm, the simulation studies carried out on a typical 154[KV] double T/L system by using EMTP software. Some test results are presented in the paper.

  • PDF

Development and Evaluation of Broadband Piezoelectric Harvesters using a Cantilever-Type Module (캔틸레버형 모듈을 이용한 광대역 압전 하베스터 개발 및 평가)

  • Park, Buem-Keun;Paik, Jong-Hoo
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.4
    • /
    • pp.261-265
    • /
    • 2020
  • In cantilever type piezoelectric energy harvester, the amount of power generation decreases rapidly when outside a certain frequency. The thickness and weight of the cantilever metal plate were modified to develop cantilevers that could produce high power over a wide frequency range. The thicker the cantilever, the higher the power in the higher frequency range. As the weight of the mass increased, the cantilever tended to generate higher power, and the frequency band decreased. A 0.6 mm metal plate cantilever that had a mass of 3.3 g generated power that exceeded 3 mW within the 91-102 Hz range, with average and output values of 9.484 mW and 20.748 mW, respectively, at 99 Hz.

Study on Evaluation of Internal Leak of Turbine Control Valve in Power Plant Using Acoustic Emission Signal Measurement (음향방출 계측에 의한 터빈 제어밸브 내부누설 평가연구)

  • Lee, S.G.
    • Journal of Power System Engineering
    • /
    • v.12 no.5
    • /
    • pp.65-70
    • /
    • 2008
  • The purpose of this study is to verify availability of the acoustic emission in-situ monitoring method to the internal leak and operating conditions of the turbine major valves relating to safety for turbine operating and prevention of turbine trouble at nuclear power plants. In this study, acoustic emission tests are performed when the pressurized electro-hydraulic control oil flowed through turbine electro-hydraulic controller oil check valve and turbine power/trip fluid solenoid valve in the condition of actual turbine operating. The acoustic emission method was applied to the valves at the site, and the background noise was measured far the abnormal plant condition. To judge for the leak existence ell the object valves, voltage analysis and frequency analysis of acoustic signal emitted from infernal leak in the valve operating condition are performed. It was conformed that acoustic emission method could monitor for valve internal leak to high sensitivity.

  • PDF

Application Study of Condition Monitoring Technology for Emergency Diesel Generator at Nuclear Power Plant (원자력발전소 비상디젤발전기 상태감시 기술 적용 연구)

  • Choi, K.H.;Park, J.H.;Park, J.E.;Lee, S.G.
    • Journal of Power System Engineering
    • /
    • v.13 no.1
    • /
    • pp.53-58
    • /
    • 2009
  • The emergency diesel generator(EDG) of the nuclear power plant is designed to supply the power to the nuclear reactor on Station Black Out(SBO) condition. The operation reliability of onsite emergency diesel generator should be ensured by a conditioning monitoring system designed to monitor and analysis the condition of diesel generator. For this purpose, we have developing the technologies of condition monitoring for the wolsong unit 3&4 standby diesel generator including diesel engine performance. In this paper, technologies of condition monitoring for the wolsong standby diesel generator are described about three step. First is for selection of operating parameter for monitoring. Second is for technologies of online condition monitoring, Third is for monitoring of engine performance.

  • PDF

A Study on the Evaluation Criteria for the Remaining Life of Hydro-Generator Stator Insulation (수력 발전기 고정자 권선의 절연수명 평가기준 설정에 관한 연구)

  • Hwang, D.H.;Kim, Y.J.;Kim, J.B.;Park, M.S.;Kim, H.G.;Lee, S.J.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1769-1773
    • /
    • 1996
  • The remaining life of generator stator winding has been the controversial issue amomg many experts in this area. The report from Japan claims that they can predict the remaining life of generator winding, while the North American has the negative opinion about it. This study aimed at verifying the validity of both Japanese criteria and North American argument on evaluation of generator winding insulation. Non destructive and destructive tests were performed on two hydro-generators. The test results showed that the trend analysis of stator winding insulation was the better option.

  • PDF

The Analysis of The Three Phase Rectifier (다중 3상 PWM 정류기의 해석)

  • Shin, D.H.;Youn, K.S.;Cho, J.G.;Kwon, W.H.
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.242-245
    • /
    • 1995
  • In this paper the multiple three rectifiers for the power factor correction are proposed, analyzed and designed. The multiple three phase rectifiers draw sinusoidal ac currents from the ac voltage sources with nearly unity input power factor and operate with PWM making the control circuit simple and system cost low. Outstandingly it reduces the rated power capacity of devices and the input filter size by reducing input current ripples. Moreover design rules can be obtained from input and output current equations. With the proposed rules, input power factor and output power capacity are determined approximately. Finally these design rules are verified with computer simulations.

  • PDF

A Study on the Life Assessment for Turbine Rotor by the In-field Electrochemical Method (터빈 수명평가를 위한 전기화학법의 현장적용에 관한 연구)

  • Chang, S.H.;Kim, J.H.;Song, G.W.;Yu, H.S.
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.13-18
    • /
    • 2000
  • Nowadays, 60 percent of thermal power plants already have been operated over their own design life. These operations of old power plant over their design life have caused a fracture accident of degradation a loss of economic and human. Therefore, the new life assessment and prediction technology is necessary to improve the safety and reliability of high pressure and high temperature power plant facilities. In this paper, innovative electrochemical test method have been used and results have been compared to the conventional test. Finally, the electrochemical test is applied to the in-field HP turbine and a database is currently in progress for the development of the life assessment standard and procedure.

  • PDF