The emergency diesel generator(EDG) of the nuclear power plant is designed to supply the power to the nuclear reactor on Station Black Out(SBO) condition. The operation reliability of onsite emergency diesel generator should be ensured by a conditioning monitoring system designed to monitor and analysis the condition of diesel generator. For this purpose, we have developing the technologies of condition monitoring for the wolsong unit 3&4 standby diesel generator including diesel engine performance. In this paper, technologies of condition monitoring for the wolsong standby diesel generator are described about three step. First is for selection of operating parameter for monitoring. Second is for technologies of online condition monitoring, Third is for monitoring of engine performance.

키워드

참고문헌

  1. US NRC, 1993, "Selection, Design, Qualification and Testing of EDG Units used as Class IE on Site Electric Power Systems at Nuclear Power Plants", Reg Guide 1.9 Rev.3, pp. 3.
  2. K. H. Choi, et al., 2007, "Development of Technology for monitoring and diagnosis of abnormal condition of SDG at Wolsong 3,4 NPP", Korea Hydro and Nuclear Power Company, R&D midterm report, pp. 106-120.
  3. J. H. Park, et al., 2007, "Selection and Analysis of Operating Parameters for Condition Monitoring of Emergency Diesel Generator at Nuclear Power Plant", The Korea Society for Power System Engineering, Vol. 11, No. 3, pp. 3-83.
  4. Mark O'connell, Mark Staley, Christian Haller, 2008, "KEPRI Engine Signature Analysis Tralning Manual", MPR, pp. 4-1-4-30.