• Title/Summary/Keyword: G-power

Search Result 4,956, Processing Time 0.043 seconds

A Maintenance Policy Determination of Dependent k-out-of-n:G System with Setup Cost (초기설치비를 고려한 의존적 k-out-of-n:G 시스템의 보전정책 결정)

  • 조성훈;안동규;성혁제;신현재
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.2
    • /
    • pp.155-162
    • /
    • 1999
  • reliability from components reliability. In this case, it assumes that components failure is mutually independent, but it may not true in real systems. In this study, the mean cost per unit time is computed as the ratio of mean life to the mean cost. The mean life is obtained by the reliability function under power rule model. The mean cost is obtained by the mathematical model based on the inspection interval. A heuristic method is proposed to determine the optimal number of redundant units and the optimal inspection interval to minimize the mean cost per unit time. The assumptions of this study are as following : First, in the load-sharing k-out-of-n:G system, total loads are applied to the system and shared by the operating components. Secondly, the number of failed components affects the failure rate of surviving components as a function of the total load applied. Finally, the relation between the load and the failure rate of surviving components is set by the power rule model. For the practical application of the above methods, numerical examples are presented.

  • PDF

Design and Fabrication of Low Frequency Driven Energy Harvester Using Electromagnetic Conversion

  • Lee, Byung-Chul;Chung, Gwiy-Sang
    • Transactions on Electrical and Electronic Materials
    • /
    • v.14 no.3
    • /
    • pp.143-147
    • /
    • 2013
  • This paper describes a low frequency driven electromagnetic energy harvester (EMEH) which consists of a thin flame resistant (FR-4) planar spring, NdFeB permanent magnets, and a copper coil. The FR-4 spring was fabricated using a desk computer numerical control (CNC) 3D modeling machine. Mathematical modeling and ANSYS finite element analysis (FEA) were used totheoretically investigate the mechanical properties of the spring mass system. The proposed EMEH generates a maximum power of 65.33 ${\mu}W$ at a resonance frequency of 8 Hz with an acceleration of 0.2 g (1 g = 9.8 $m/s^2$) and a superior normalized power density (NPD) of 77 ${\mu}W/cm^3{\cdot}g^2$.

The On-Line Economic Load Dispatch Program of Kwangyang Steel Works (광양제철소의 실시간 경제운용 프로그램 개발)

  • Kim, Jae-Chul;Baek, Young-Sik;Lee, Hee-Choon
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.7
    • /
    • pp.318-323
    • /
    • 2001
  • This paper proposes an efficient method of On-Line Economic Load Dispatch(ELD) using Evolutionary Programming(EP) technique at KwangYang steel works. The economic operation of steel works is done by experienced engineer. So far, there is no formulation and algorithm of economic operation of steel works. In this paper, we propose the formulation and On-Line algorithm of economic operation of steel works. The EP technique is the kind of Evolutionary Computation(EC), which has become a candidate for many optimization applications due to its flexibility and efficiency. Based on the EP technique, the proposed algorithm is capable of not only solving the economic problem, but also obtaining the global optimal solutions within reasonable execution time. To validate our proposed approach, the algorithm is demonstrated on many sample systems and compared to actual values of steel works.

  • PDF

Output Characteristics of PV System Using Fuzzy Controller (퍼지제어기를 이용한 태양광발전 시스템의 출력특성)

  • Lim, H.W.;Kim, S.K.;Choi, Y.O.;Seo, J.Y.;Oh, G.G.;Cho, G.B.;Baek, H.L.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07e
    • /
    • pp.140-143
    • /
    • 2003
  • In order to improve the system utility efficiency of energy conversion, it is desirable to operate the PV system at maximum power point of solar cell under versable condition. This paper describes the experimental results of the PV system that contains a solar modules and DC-DC converter(boost type chopper). The Simulation results show that the PV system always operate at maximum power point of solar cells having stabilize output voltage waveform with relatively small ripple component.

  • PDF

Design of a Ka-Band Microstrip Array Antenna for Satellite Communication (위성통신용 Ka-Band 마이크로스트립 배열안테나의 설계)

  • 류정기;임인성;이덕재;민경일;오승엽
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.1
    • /
    • pp.142-149
    • /
    • 1999
  • In this paper, Aperture-coupled microstrip array antenna was designed and manufactured for satellite communication at Ka-Band. We analyzed a microstrip radiation element and designed power divider using $\lambda$g/4 transformer and T-junction power divider. A manufactured Aperture-coupled $2\times2$ microstrip array antenna has a resonant frequency of 20 GHz. The experimental results are as followings : resonant frequency of 19.62 GHz, VSWR 1.0692, return loss -29.61 dB, Bandwidth 1.76 GHz and -3 dB beamwidth $42^{\circ}$.

  • PDF

TOTAL DOMINATION NUMBER OF CENTRAL TREES

  • Chen, Xue-Gang;Sohn, Moo Young;Wang, Yu-Feng
    • Bulletin of the Korean Mathematical Society
    • /
    • v.57 no.1
    • /
    • pp.245-250
    • /
    • 2020
  • Let γt(G) and τ(G) denote the total domination number and vertex cover number of graph G, respectively. In this paper, we study the total domination number of the central tree C(T) for a tree T. First, a relationship between the total domination number of C(T) and the vertex cover number of tree T is discussed. We characterize the central trees with equal total domination number and independence number. Applying the first result, we improve the upper bound on the total domination number of C(T) and solve one open problem posed by Kazemnejad et al..

Effect of Additive Gas on the Bonding Structure of a-C:H Films Deposited by rf PECVD (rf PECVD법으로 증착된 a-C:H 박막의 결합구조에 미치는 보조가스의 영향)

  • Song, Jae-Jin;Kim, Seong-Jin
    • Korean Journal of Materials Research
    • /
    • v.9 no.11
    • /
    • pp.1088-1094
    • /
    • 1999
  • 본 연구에서는 rf PECVD(13.56MHz)법을 이용하여 $CH_4$가스에 소량의 보조가스($O_2$$N_2$)를 혼합하여 a-C:H 박막을 얻었다. 이렇게 얻어진 박막의 증착속도는 rf power 증가에 따라서 증가하다가 200W에서는 다시 감소하였으며, 산소와 질소가스의 유량이 증가함에 따라 감소하였다. FT-IR분석으로 계산된 박막내의 수소함량은 rf power 증가와 산소 및 질소첨가량의 증가에 따라 감소하였다. 산소가스 첨가 시에는 C=O 결합이 생성되며, 질소가스 첨가 시에는 C=N 결합이 생성됨을 FT-IR 분석을 통하여 알 수 있었다. 이와 같이 산소와 질소를 보조가스로 첨가할 경우에 스퍼터링 효과로 박막내의 수소함량 감소와 더불어 a-C:H 박막의 구조 변화를 일으킬 수 있을 것으로 생각된다. Raman 분석결과 산소와 질소를 첨가함에 따라서 I(sub)D/I(sub)G비가 증가하였고, D line과 G line의 위치가 높은 파수 쪽으로 이동하였으며, D line의 폭은 넓어지는 반면에 G line의 폭은 감소됨을 보였다. 이것은 산소와 질소의 첨가로 박막내의 수소함량 감소, 결합각의 disorder 감소 및 micro-crystallite 흑연의 형성에 의한 것이라고 판단된다.

  • PDF

Design of Low Pass Filter to reduce EMI from 2.SG SDH system (2.5G SDH 전자파 감소용 저역통과필터 설계)

  • 이성원;김영범
    • Journal of the Korea Society for Simulation
    • /
    • v.10 no.4
    • /
    • pp.21-30
    • /
    • 2001
  • In this paper, EMI measurement, the STGU simulation being conducted, filter design, its characteristics, and its implementation to the PCB, and finally test results are discussed. When the low pass filter was implemented within the STGU, the power of EMI decreased more than 20dBm. Finally, when TE and MTIE, two important quality measure in synchronous reference clock, was assessed, ITU-T G813 requirement was satisfied. EMI(Electromagnetic Interface) is a measure of electomagnetic radiation from equipment in the range of 10KHz to 3GHz, and can cause unexpected reactions of electronics/electrical equipment. In this study, for safe and stable communication operation, a STGU (System Timing Generation Unit), which is a 2.5G SDH System and a major EMI source, was employed to simulate electromagnetic interface. Using Open-Site test, the power of fundamental frequency of EMI of interest and its harmonics were measured. Also, a low pass filter at cut-off frequency of 2GHz was specifically designed for this study to minimize the effect of EMI between electronic components.

  • PDF

The Method of Battery Lifetime Optimization for V2G System considering Load Leveling (부하평준화를 고려한 V2G 시스템의 배터리 수명 최적화 기법)

  • Shin, Chang-Hyun;Kim, Do-Yun;Won, Il-Kuen;Kim, Young-Real;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.538-539
    • /
    • 2014
  • The development of smart grid technologies will enable enhanced utilization of electric vehicles(EV) as portable energy storage devices which can provide power system-wide. Because significant increase of EV in the near future, V2G(Vehicle-to-Grid) system will soon become a reality. This paper presents the optimal method of a battery lifetime depending on depth of discharge(DOD) considering load leveling.

  • PDF

The Performance of ZnO Varistors and Surge Protector for 154kV Underground Cable (154kV 지중 방식층용 ZnO소자 및 서지 보호장치 성능)

  • Cho, H.G.;Man, D.H.;Yoon, H.S.;Lee, J.H.;Jang, T.B.;Lee, H.G.
    • Proceedings of the KIEE Conference
    • /
    • 2001.11a
    • /
    • pp.248-250
    • /
    • 2001
  • The surge protector is crucial power apparatus to guarantee the safe operation of power transmission of underground cable which can effectively restrain the overvoltage and inductive lightning stroke in power system. This paper describes the results of a study on the performance of ZnO varistors and surge protector for 154 kV underground cable. And, the influence of water tight and insulating performance was evaluated through such as surge protector of the armored design.

  • PDF