• Title/Summary/Keyword: Fusion mass

Search Result 203, Processing Time 0.02 seconds

Posterior Atalntoaxial Fusion with C1 Lateral Mass Screw and C2 Pedicle Screw Supplemented with Miniplate Fixation for Interlaminar Fusion : A Preliminary Report

  • Yoon, Sang-Mok;Baek, Jin-Wook;Kim, Dae-Hyun
    • Journal of Korean Neurosurgical Society
    • /
    • v.52 no.2
    • /
    • pp.120-125
    • /
    • 2012
  • Objective : To investigate the feasibility of C1 lateral mass screw and C2 pedicle screw with polyaxial screw and rod system supplemented with miniplate for interlaminar fusion to treat various atlantoaxial instabilities. Methods : After posterior atlantoaxial fixation with lateral mass screw in the atlas and pedicle screw in the axis, we used 2 miniplates to fixate interlaminar iliac bone graft instead of sublaminar wiring. We performed this procedure in thirteen patients who had atlantoaxial instabilities and retrospectively evaluated the bone fusion rate and complications. Results : By using this method, we have achieved excellent bone fusion comparing with the result of other methods without any complications related to this procedure. Conclusion : C1 lateral mass screw and C2 pedicle screw with polyaxial screw and rod system supplemented with miniplate for interlaminar fusion may be an efficient alternative method to treat various atlantoaxial instabilities.

An Analysis of The Fusion Cuisine Recipe on Mass Media (주요 매체에 게재된 퓨전요리의 레시피 분석)

  • 신애숙;안형기
    • Culinary science and hospitality research
    • /
    • v.7 no.3
    • /
    • pp.163-178
    • /
    • 2001
  • The purpose of this study is analysis of fusion cuisine recipe a gathering datum and informations for development of the fusion cuisine. The fusion cuisine is a new creative cuisine that come from a mixing between different cuisine recipe especially eastern cuisine wi th western cuisine. The fusion food is becoming a world popular food since 1980's. In Korea, the fusion food is favorite food is needed for development of the fusion cuisine, and we are able to get the datum and informations from mass media such as cuisine journals, newspapers and internet web site. Results of the analysis are as follows : 1. The fusion cuisine that core stuff is the grain have features that make a use of a spice and fat such as butter and olive oil. Boiling is used most frequently as a way of cooking among the grain centred fusion cuisine. Spagetti is used very after as a stuff for the fusion food. 2. The fusion cuisine that core stuff is meat make use of unusual meat such as the pigeons and spicery, and its popular cooking way is a baking. 3, The fusion cuisine that core stuff is a fish make use of herbs and alchole to get rid of a fishy smell, and various sauces are used for promoting taste and styling. 4. The fusion cuisine that core stuff is fruit and vegetables make use of boiling as cooking ways most frequently, but in the case that cook try to keep nutritive qualities, baking is used most frequently. 5. In beverage centred fusion cuisine, mixing of alchole with juice is most popular, its taste and color is unusually gorgeous.

  • PDF

The Change of Biomechanical Milieu after Removal of mstnnnentation in lrunbar Arthrodesis Stiffness of fusion Mass: Finite Element Analysis (척추 유합술 후, 인접 분절의 스트레스에 대한 척추경 나사못에 대한 영향)

  • Kang, Kyoung-Tak;Chun, Heoung-Jae;Son, Ju-Hyun;Kim, Ho-Joong
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.664-667
    • /
    • 2008
  • Since the advent of pedicle screw fixation system, posterior spinal fusion has markedly increased This intemal fixation system has been reported to enhance the fusion rates, thereby becoming very popular procedure in posterior spinal arthrodesis. Although some previous studies have shown the complications of spinal instruments removal, i.e. loss of correction and spinal collapse in scoliosis or long spine fusion patients, there has been no study describing the benefit or complications in lumbar spinal fusion surgery of one or two level. In order to clarify the effect of removal of instruments on mechanical motion profile, we simulated a finite element model of instrumented posterolateral fused lumbar spine model, and investigated the change of mechanical motion profiles after the removal of instrumentation.

  • PDF

Highly Dispersed CuO Nanoparticles on SBA-16 Type Mesoporous Silica with Cyclam SBA-16 as a Precursor

  • Prasetyanto, Eko Adi;Sujandi, Sujandi;Lee, Seung-Cheol;Park, Sang-Eon
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.12
    • /
    • pp.2359-2362
    • /
    • 2007
  • MALDI-TOF-MS technique was applied to obtain structural and compositional information of synthetic polyamides, Nylon6 and Nylon66. Mass spectra of both the original and the hydrolyzed polyamide samples were analyzed using the self calibration method as well as the internal calibration method with the standard materials of known masses. The MALDI-TOF mass spectra of Nylon6 samples showed the presence of protonated, sodiated, and potassiated ions that were assigned to cyclic and NH2/COOH terminated linear oligomers. From the MALDI-TOF mass spectra of Nylon66 samples, the potassiated linear oligomers with three different end groups are identified as well as the cyclic oligomers, i.e., NH2/COOH terminated oligomers, NH2/NH2 terminated oligomers, and COOH/COOH terminated oligomers. Full characterization of the molecular species and end groups present in the polyamide samples has been achieved, and also the changes in mass spectral patterns after the hydrolysis of the samples are presented.

Study of CO2+(CO2)n Cluster in a Paul Ion Trap

  • Karimi, L.;Sadat Kiai, S.M.;babazaheh, A.R.;Elahi, M.;Shafaei, S.R.
    • Mass Spectrometry Letters
    • /
    • v.10 no.1
    • /
    • pp.27-31
    • /
    • 2019
  • In this article, the properties of ${CO_2}^+(CO_2)_n$ clusters in a Paul ion trap have been investigated using mass-selective instability mode which conducted by chosen precursor ions, mainly $Ar^+$ and ${CO_2}^+$ produced by a mixture of Ar and $CO_2$. Exposure of ${CO_2}^+$ ions to $CO_2$ molecules, lead to the formation of ${CO_2}^+(CO_2)_n$ clusters. Here, Ar gas react as a buffer gas and lead to form ${CO_2}^+(CO_2)_n$ cluster by collisional effect.

Radiographic Analysis of Instrumented Posterolateral Fusion Mass Using Mixture of Local Autologous Bone and b-TCP (PolyBone$^{(R)}$) in a Lumbar Spinal Fusion Surgery

  • Park, Jin-Hoon;Choi, Chung-Gon;Jeon, Sang-Ryong;Rhim, Seung-Chul;Kim, Chang-Jin;Roh, Sung-Woo
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.5
    • /
    • pp.267-272
    • /
    • 2011
  • Objective : Although iliac crest autograft is the gold standard for lumbar fusion, the morbidity of donor site leads us to find an alternatives to replace autologous bone graft. Ceramic-based synthetic bone grafts such as hydroxyapatite (HA) and b-tricalcium phosphate (b-TCP) provide scaffolds similar to those of autologous bone, are plentiful and inexpensive, and are not associated with donor morbidity. The present report describes the use of Polybone$^{(R)}$ (Kyungwon Medical, Korea), a beta-tricalcium phosphate, for lumbar posterolateral fusion and assesses clinical and radiological efficacy as a graft material. Methods : This study retrospectively analyzed data from 32 patients (11 men, 21 women) who underwent posterolateral fusion (PLF) using PolyBone$^{(R)}$ from January to August, 2008. Back and leg pain were assessed using a Numeric Rating Scale (NRS), and clinical outcome was assessed using the Oswestry Disability Index (ODI). Serial radiological X-ray follow up were done at 1, 3, 6 12 month. A computed tomography (CT) scan was done in 12 month. Radiological fusion was assessed using simple anterior-posterior (AP) X-rays and computed tomography (CT). The changes of radiodensity of fusion mass showed on the X-ray image were analyzed into 4 stages to assess PLF status. Results : The mean NRS scores for leg pain and back pain decreased over 12 months postoperatively, from 8.0 to 1.0 and from 6.7 to 1.7, respectively. The mean ODI score also decreased from 60.5 to 17.7. X-rays and CT showed that 25 cases had stage IV fusion bridges at 12 months postoperatively (83.3% success). The radiodensity of fusion mass on X-ray AP image significantly changed at 1 and 6 months. Conclusion: The present results indicate that the use of a mixture of local autologous bone and PolyBone$^{(R)}$ results in fusion rates comparable to those using autologous bone and has the advantage of reduced morbidity. In addition, the graft radiodensity ratio significantly changed at postoperative 1 and 6 months, possibly reflecting the inflammatory response and stabilization.

Analysis of Posterior Cervical Fixation and Fusion in Subaxial Cervical Spine Injury (중하부 경추손상에서 후방 경추 내고정술 및 골유합술의 분석결과)

  • Lee, Dong Hoon;Song, Geun Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.12
    • /
    • pp.1388-1393
    • /
    • 2001
  • Objective : In the retrospective analyzing 19 consecutive patients with subaxial cervical spine(C3~T1) injury treated by posterior cervical fixation and fusion, clinical manifestation, radiologic finding, operative technique, and postoperative results following 6 months were analyzed. Materials and Methods : Most common fracture level was C4-5, mean age 41, and male to female ratio 13 : 6. The most common cause of injury was motor vehicle accident(17 cases). In 19 cervical procedures, interspinous triple wiring was done in 14 cases, lateral mass plating in 5 cases, and additional anterior fusion in 2 cases. Results : Twelve weeks after operation, all cases were reviewed by plain cervical radiogram. In 17 cases that treated by posterior fusion only, 14 cases(81%) had kyphotic angle change less than $5^{\circ}$, 2 cases(12%) $5-20^{\circ}$, and 1 case(6%) more than $20^{\circ}$. Overall fusion rate was 88%, and there was no significant difference of bone fusion rate between autogenous bone graft and allogenous bone graft. Conclusion : In the case of severe posterior column injury or displacement, posterior approach seems superior to anterior approach, but in the case of combined anterior column injury, anterior approach is considered necessary. In this study, posterior fixation and fusion might be acceptable procedure for subaxial cervical fracture and dislocation, owing to its high fusion rate, low kyphotic angulation and low operation related complication rate.

  • PDF

The Orientation-Dependent Expression of Angiostatin-Endostatin Hybrid Proteins and Their Characterization for the Synergistic Effects of Antiangiogenesis

  • Paek, Sun-Yeol;Kim, Yong-Seok;Choi, Shin-Geon
    • Journal of Microbiology and Biotechnology
    • /
    • v.20 no.10
    • /
    • pp.1430-1435
    • /
    • 2010
  • Two angiostatic fusion proteins (hAE and hEA), differing in tandem connection manners, were constructed from human angiostatin (hAS) and endostatin (hES) proteins. These fusion proteins were then evaluated for synergistic antiangiogenic properties. The 65 kDa secreted fusion proteins, expressed in Pichia pastoris, were verified by both mass analysis and Western blotting assay. Luciferase reorter gene assay, using a VEGF promoter, revealed that the angiostatin-endostatin fusion protein (hAE), and its corresponding fusion gene delivery on human microvascular endothelial cells (HMEC-1), resulted in a more potent synergistic antiangiogenic effect than the endostatin-angiostatin fusion protein (hEA). These results suggest that the orientation of the fusion genes in hAS and hES might be an important factor in the development of therapeutic proteins.

Ligamentum Flavum Hematoma in the Adjacent Segment after a long Level Fusion

  • Kim, Hyeun-Sung;Kim, Seok-Won;Lee, Sung-Myung;Shin, Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.1
    • /
    • pp.58-60
    • /
    • 2011
  • Ligamentum flavum hematoma (LFH) is a very rare condition of dural compression; most are observed in the mobile cervical and lumbar spine regions. A 67-year-old man who had a long level interbody fusion at L3-S1 four years ago presented with symptoms suggestive of dural compression. Magnetic resonance imaging showed a posterior semicircular mass located at the adjacent L2-L3 level. After decompression of the spinal canal and removal of the mass lesion, pathological examination of the surgical specimen revealed a hematoma within the ligamentum. The patient fully recovered to normal status after surgery. Here, we report our experience with a LFH in the adjacent segment after a long level fusion procedure and discuss the possible associated mechanisms.