• Title/Summary/Keyword: Fusion Zone

Search Result 227, Processing Time 0.021 seconds

Measurement of Temperature Field in the Primary Deformation Zone in 2-D Orthogonal Machining Using IR (Infra-Red) Thermography (순수 2 차원 절삭에서 적외선 열화상을 이용한 주변형 영역의 온도 분포 측정)

  • Kim, Myung-Jae;Jung, Hyun-Gi;Hwang, Ji-Hong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.8
    • /
    • pp.853-862
    • /
    • 2012
  • The present study develops a method for directly measuring the temperature field in the primary deformation zone with a high spatial resolution during 2-D orthogonal machining. This is enabled by the use of a high-speed, charge-coupled device (CCD) based, infra-red (IR) imaging system which allows characteristics of the temperature field such as the location and magnitude of the highest temperature and temperature gradient in the primary deformation zone to be identified. Based on these data, the relation between the machining temperature and the cutting conditions is investigated.

A Study on the Laser Beam Weldability Using Zircaloy-4 Cladding Tube (지르칼로이-4 피복관을 이용한 레이저용접성 연구)

  • 박진석;김동균;김상태;양명승;김수성;이정원
    • Journal of Welding and Joining
    • /
    • v.20 no.6
    • /
    • pp.72-72
    • /
    • 2002
  • Corrosion and tensile properties of zircaloy-4 cladding tube having a laser welding part in elevated temperature are studied to present the criterion of quality evaluation in nuclear reactor and find the scientific basis of SCC, with laser welding method using by coupling up cladding tube to end cap. In the result of tensile test(400℃), the fracture is not happened in the welding part but base metal and the result of corrosion test(400℃ 1500psi steam), corrosion rate of the molten zone and PMZ is a little higher than the other zone.

A Study on the Laser Beam Weldability Using Zircaloy-4 Cladding Tube (지르칼로이-4 피복관을 이용한 레이저용접성 연구)

  • 박진석;김동균;김상태;양명승;김수성;이정원
    • Journal of Welding and Joining
    • /
    • v.20 no.6
    • /
    • pp.796-801
    • /
    • 2002
  • Corrosion and tensile properties of zircaloy-4 cladding tube having a laser welding part in elevated temperature are studied to present the criterion of quality evaluation in nuclear reactor and find the scientific basis of SCC, with laser welding method using by coupling up cladding tube to end cap. In the result of tensile test($400^{\circ}C$), the fracture is not happened in the welding part but base metal and the result of corrosion test($400^{\circ}C$ 1500psi steam), corrosion rate of the molten zone and PMZ is a little higher than the other zone.

Multisensor Image Fusion for Enhanced Coastal Wetland Mapping

  • Shanmugam, P.;Ahn, Yu-Hwan;Sanjeevi, S.;Yoo, Hong-Ryong
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.902-904
    • /
    • 2003
  • The main objective of this paper is to investigate the potential utility of multisensor remotely sensed data for improved coastal wetland mapping. Five data fusion models, three algebraic models (Multiplicative (MT), Brovey (BT) and Wavelet transform (WT)) and two spectral domain models (Principals component transform (PCT) and Intensity-Hue-Saturation (IHS)) were implemented and tested over the multisensor data. The fused images were then compared based on visual and statistical approaches. The results show that the wavelet transform provides greater flexibility for combining optical data sets and has good potential for preserving the spatial and spectral content of the original images . However, this model yields poor information when combining optical and microwave data. Brovey transform is more reliable for fusing optical and microwave image data and yields improved information about different wetland features of the coastal zone.

  • PDF

Expression of Antibacterial Cationic Peptides from Methylotrophic Yeast, Pichia pastoris

  • Lee, Gang-U;Choe, Yun-Jae
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.11a
    • /
    • pp.669-671
    • /
    • 2000
  • Antimicrobial cationic peptides have attracted increasing research and clinical interest as a natural antibiotics due to their broad spectrum of antimicrobial activites and the rapid development of multidrug-resistant pathogenic microorganisms. In this study, first, we synthesized artificial fusion partner and cationic peptide genes (lactoferricin, magainin, protegrin-1, and indolicidin). Second, we constructed recombinant expression vectors and then transformed Pichia pastoris. Finally, expressed cationic peptides were purified and tested for their antimicrobial activites. Antimicrobial activity has been tested upon the appearance of clearing zone on the plate with the lawn of gram negative E.coli XL- I blue and garm positive Staphylococcus aureus. Protegrin-1 and Indolicidin have apparant activity of cationic peotides. This fusion technique may lead to a general and suitable tool for production of pure antimicrobial cationic peptides in Pichia pastoris.

  • PDF

Microstructural Characteristics of T-bar Welding Zone for Shipbuilding and Offshore Plants (조선해양플랜트용 T-bar 용접부의 미세조직학적 특성에 관한 연구)

  • Hwang, Y.J.;Choi, Y.S.;Jang, J.H.;Lee, S.I.;Gong, K.Y.;Lee, DG.
    • Transactions of Materials Processing
    • /
    • v.27 no.5
    • /
    • pp.296-300
    • /
    • 2018
  • T-type and H-type section steels were generally used in shipbuilding and offshore plants and were produced by welding technology. These section steels were produced by handwork, and the supplying amounts can't satisfy the demand amounts of the fabrication companies. In case of fillet welding, there are some gaps in weld-joint region due to no groove preparation processing and it can occur crack initiation in the welded region. It is important to evaluate the microstructural and mechanical properties of welded zone to solve these problems. To satisfy the demand amounts of T-bar parts, automatic welding technology was introduced and several conditions as a function of welding speeds were carried out to improve the manufacturing speed. Heat-affected zone may be affected by variation of heat input and cooling rate through automatic welding speed and welding speed is necessary to be optimized. In this study, fusion zone and heat-affected zone were investigated by microstructural and mechanical analysis and were evaluated whether the welded parts were sound or not.

Effect of Nitrogen Volume in Ar-N2 Shielding Gas on Microstructure and Hardness of GTA Welded Pure Ti (순 Ti GTA 용접부의 미세조직과 경도에 미치는 Ar-N2 보호가스 중 질소량의 영향)

  • An, Hyun-Jun;Jeon, Ae-Jeong;Hong, Jae-Keun;Jeong, Bo-Young;Lee, Jong-Sub;Kang, Chung-Yun
    • Journal of Welding and Joining
    • /
    • v.30 no.2
    • /
    • pp.70-75
    • /
    • 2012
  • In this study, effect of nitrogen volume in the shielding gas of Ar-$N_2$ mixing gas on the bead shape, hardness and microstructure of GTA welds of 3mm thick Commercial Pure Ti was investigated. As the nitrogen volume increased, the welding current for full penetration was reduced and hardness in the fusion zone significantly increased compared with that of the base metal, but there is no difference in the hardness of HAZ. Microstructure in the fusion zone with pure Ar gas changed from equiaxed alpha of the base metal to serrated alpha. On the other hand, microstructure using Ar-$N_2$ mixing gas changed to acicular alpha. With the increasing of nitrogen content, the amount of acicular alpha increased and the size of that was fine.

The Influence of Shield Gas Ratio on the Toughness of A15083-0 GMAW Weld Zone (A15083-O GMAW 용접시 불활성가스 혼합비가 용접부의 인성에 미치는 영향에 관한 연구)

  • 이동길;김건호
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.113-199
    • /
    • 2002
  • In this study, the toughness was evaluated by using the instrumented Charpy impact testing procedures for A15083-O aluminum alloy used in the LNG carrying and storing tank. The specimens were GMAW welded with four different mixing shield gas ratios (Ar100%+He0%, Ar67%+He33%, Ar50%+He50%, and Ar33%+He67%), and tested at four different temperatures(+25, -30, -85, and -196$^{\circ}C$ ) in order to investigate the influence of the mixing shield gas ratio and the low temperature. The specimens were divided into base metal, weld metal, fusion line, and HAZ specimen according to the worked notch position. From experiment, the maximum load increased a little up to -85$^{\circ}C$, and the maximum load and maximum displacement were shown the highest and the lowest at -196$^{\circ}C$ than the other test temperatures. The absorption energy of weld metal notched specimens was not nearly depends on test temperature and mixing shield gas ratio because the casting structure was formed in weld metal zone. In the other hand, the others specimens was shown that the lower temperature, the higher absorption energy slightly up to -85$^{\circ}C$ but the energy was decreased so mush at -196$^{\circ}C$

  • PDF