• Title/Summary/Keyword: Fusion Image

Search Result 878, Processing Time 0.027 seconds

The Effects of Image Quality due to Scattering X-ray according to increasing Patient Thickness (피사체 두께에 따른 산란선 발생이 화질에 미치는 영향)

  • Park, Ji-Koon;Yang, Sung-Woo;Jun, Jae-Hoon;Cho, Su-Yeon;Kim, Kyo-Tae;Heo, Ye-Ji;Kang, Sang-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.671-677
    • /
    • 2017
  • In this study, scattering factors affecting the quality of medical images were quantitatively analyzed and investigated. MCNPX simulation was conducted by using ANSI phantom, made of tissue equivalent materials, to calculate the scattering ratio occurred by the increase of the object thickness. Then, the result of the simulation was compared with the result of actual radiation measurement. In addition, we evaluated the image quality by the RMS evaluation, RSD and NPS analysis using X-ray images acquired with increasing object thickness. Furthermore, the scattering ratio was analyzed by increasing the thickness of acrylic phantom on chest phantom. The result showed that the scattering ratio was increased to 57.2%, 62.4%, and 66.8% from 48.9%, respectively, when the acrylic phantom thickness was increased by 1 inch from 6.1 inches. The results of MCNPX simulation and the actual measured scattering dose showed similar results. Also, as a result of RMS measurement from acquired x-ray images, the standard deviation decreased as the object thickness increased. However, in the RSD analysis considering the average incident dose, the results were increased from 0.028 to 0.039, 0.051, 0.062 as the acrylic phantom thickness was increased from 6.1 inches to 7.1 inch, 8.1 inch, and 9.1 inch, respectively. It can be seen that the increase of the scattering effect due to the increase of the object thickness reduces the SNR. Also, the NPS results obtained by measuring scattered radiation incident on the detector resulted in the increase of the noise as the object thickness increased.

Fine Co-registration Performance of KOMPSAT-3·3A Imagery According to Convergence Angles (수렴각에 따른 KOMPSAT-3·3A호 영상 간 정밀 상호좌표등록 결과 분석)

  • Han, Youkyung;Kim, Taeheon;Kim, Yeji;Lee, Jeongho
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.37 no.6
    • /
    • pp.491-498
    • /
    • 2019
  • This study analyzed how the accuracy of co-registration varies depending on the convergence angles between two KOMPSAT-3·3A images. Most very-high-resolution satellite images provide initial coordinate information through metadata. Since the search area for performing image co-registration can be reduced by using the initial coordinate information, in this study, the mutual information method showing high matching reliability in the small search area is used. Initial coarse co-registration was performed by using multi-spectral images with relatively low resolution, and precise fine co-registration was conducted centering on the region of interest of the panchromatic image for more accurate co-registration performance. The experiment was conducted by 120 combination of 16 KOMPSAT-3·3A 1G images taken in Daejeon area. Experimental results show that a correlation coefficient between the convergence angles and fine co-registration errors was 0.59. In particular, we have shown the larger the convergence angle, the lower the accuracy of co-registration performance.

Adolescent Idiopathic Scoliosis Treatment by a Korean Neurosurgeon : The Changing Role for Neurosurgeons

  • Hyun, Seung-Jae;Kim, Woong-Beom;Park, Young-Seop;Kim, Ki-Jeong;Jahng, Tae-Ahn;Kim, Yongjung J.
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.1
    • /
    • pp.50-53
    • /
    • 2015
  • Objective : The purpose of this study was to evaluate radiographic/clinical outcomes of adolescent idiopathic scoliosis (AIS) patients treated by a Korean neurosurgeon. Methods : Ten AIS patients were treated by a single neurosurgeon between January 2011 and September 2013 utilizing segmental instrumentation with pedicle screws. Basic demographic information, curve pattern by Lenke classification, number of levels treated, amount of correction achieved, radiographic/clinical outcomes [by Scolisis Resarch Society (SRS-22r) questionnaire] and complications were evaluated to determine the surgical results. Pulmonary function test was utilized to assess forced vital capacity (FVC) and forced expiratory volume in one second (FEV1) before and after surgery. Results : The average percentage of correction of the major structural curve was 73.6% (ranged from 64% to 81.5%). Preoperative and final postoperative absolute FVC averaged 3.03 L and 3.76 L (0.73 L increase, p=0.046), and absolute FEV1 averaged 2.63 L and 3.49 L (0.86 L increase, p=0.021). Preoperative and final postoperative average self-image and function scores of SRS-22r were, $2.6{\pm}0.5$, $3.3{\pm}0.1$, $4.0{\pm}0.5$, and $4.6{\pm}0.0$, respectively. There was a significant improvement of the self-image and function scores of SRS-22r questionnaires before and after surgery (p<0.05). There was no case of neurological deficit, infection and revision for screw malposition. One patient underwent a fusion extension surgery for shoulder asymmetry. Conclusion : Radiographic/clinical outcomes of AIS patients treated by a Korean neurosurgeon were acceptable. Fundamental understanding of pediatric spinal deformity is essential for the practice of AIS surgery.

Gamma Ray Detection Processing in PET/CT scanner (PET/CT 장치의 감마선 검출과정)

  • Park, Soung-Ock;Ahn, Sung-Min
    • Journal of radiological science and technology
    • /
    • v.29 no.3
    • /
    • pp.125-132
    • /
    • 2006
  • The PET/CT scanner is an evolution in image technology. The two modalities are complementary with CT and PET images. The PET scan images are well known as low resolution anatomic landmak, but such problems may help with interpretation detailed anatomic framework such as that provided by CT scan. PET/CT offers some advantages-improved lesion localization and identification, more accurate tumor staging. etc. Conventional PET employs tranmission scan require around 4 min./bed position and 30 min. for whole body scan. But PET/CT scanner can reduced by 50% in whole body scan. Especially nowadays PET scanner LSO scintillator-based from BGO without septa and operate in 3-D acquisition mode with multidetectors CT. PET/CT scanner fusion problems solved through hardware rather than software. Such device provides with the capability to acquire accurately aligned anatomic and functional images from single scan. It is very important to effective detection from gamma ray source in PETdetector. And can be offer high quality diagnostic images. So we have study about detection processing of PET detector and high quality imaging process.

  • PDF

Textuality and Vision : Visual Narrative of Ancient Chinese Literature Art Focused on Narratology's Viewpoint (중국 고대예술의 도상서사와 시각문화 연구 -회화의 이시동도법과 만화의 칸의 상호 해석-)

  • Jo, Jeong-rae;Huang, Kuo-Li
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.9
    • /
    • pp.779-790
    • /
    • 2016
  • This study is to exhibit the iconographic narrative and visual culture of ancient Chinese art. The focus of the study is the composite integration of literature and graphic forms, in particular the heterochronous expression of different scenarios of scenes occurring in different time periods in pictures of ancient art. The unity of their origins with picture narration and comic art creation is the fusion of our modern times. The ancient Chinese understanding of visual art includes the traditional style of images and their symbolic meanings. Among artistic narrative expression, imagery contemplation and visual presentation have significance. Artistic thinking is inseparable from visual articulation. It is a rational thought process through creative language interpretation in visual media of imagery narratives. The characteristics of ancient imagery thinking and the way of presenting sequential incidents in the form pictures is a creative space of time. This is the spatial thinking of modern comic art, which is demonstrated through acceptance in artistic styles. Image narration needs new forms and media styles, including integrating with cultural values as aesthetic communication is necessary.

Validation on the Utilization of Small-scale Unmanned Aerial Systems(sUAS) for Topographic Volume Calculations (토공량 산정을 위한 소형무인항공시스템의 활용성 평가)

  • Lee, Yong-Chang
    • Journal of Cadastre & Land InformatiX
    • /
    • v.47 no.1
    • /
    • pp.111-126
    • /
    • 2017
  • Small-scale UAS(Fusion technique of Unmanned Aerial Vehicles platform and Sensors, 'sUAS') opens various new applications in construction fields and so becoming progressively common due to the considerable potentials in terms of accuracy, costs and abilities. The purpose of this study is that the investigation of the validation on the utilization of sUAS for earth stockpile volume calculations on sites. For this, generate 3D models(DSM) with sUAS aerial images on an cone shaped soil stockpile approximately $270m{\times}300m{\times}20m$, which located at Baegot Life Park in Siheung-si, compared stockpile volume estimates produced by sUAS image analysis, against volume estimates obtained by GNSS Network-RTK ground surveying method which selected as the criteria of earth stockpile volume. The result through comparison and examination show(demonstrate) that there was under 2% difference between the volume calculated with the GNSS Network RTK data and the sUAV data, especially sUAS imaged-based volume estimate of a stockpile can be greatly simplified, done quickly, and very cost effective over conventional terrestrial survey methods. Therefore, with consideration of various plan to assess the height of vegetation, sUAS image-based application expected very useful both volume estimate and 3D geospatial information extraction in small and medium-sized sites.

Usefulness Assessment of Automatic Analysis Program for Flangeless Esser PET Phantom Images (Flangeless Esser PET Phantom 영상 자동 분석 프로그램의 유용성 평가)

  • NamGung, Chang-Kyeong;Nam, Ki-Pyo;Kim, Kyeong-Sik;Kim, Jeong-Seon;Lim, Ki-Cheon;Shin, Sang-Ki;Cho, Shee-Man;Dong, Kyung-Rae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.63-66
    • /
    • 2009
  • Purpose: ACR (American College of Radiology) offers variable parameters to PET/CT quality control by using ACR Phantom. ACR Phantom was made to evaluate parameters which are uniformity, attenuation, scatter, contrast and resolution. Manual analysis method wasn't good for the use of QC because values of parameter were changed as it may user and it takes long time to analysis. Ki-Chun Lim, a nuclear scientist in AMC, developed program that automatically analysis values of parameter by using ACR Phantom to overcome above problems. In this study, we evaluated automatic analysis program's usability, through the comparing SUV of each method, reproducibility of SUV when repeated analysis and the time required. Materials and Methods: Using Flangeless Esser PET Phantom, the ideal ratio of 4 : 1 hot cylinder and BKG but it actually showed a ratio of 3.89 to 1 hot cylinder and BKG. SIEMENS Biograph True Point 40 was used in this study. We obtained images using ACR phantom at Fusion WB PET Scan condition (2 min/bed) and 120 kV, 100 mAs CT condition. Using True X method, 3 iterations, 14 subsets, Gaussian filter, FWHM 4 mm and Zoom Factor 1.0, $168{\times}168$ image size. We obtained Max. & Min. SUV and SUV Mean values at Cylinder (8, 12, 16, 25 mm, Air, Bone, Water, BKG) by automatic program and obtained SUV by manual method. After that, we compared manual and automatic method. we estimate the time required from opened the image data to final work sheet was completed. Results: Automatic program always showed same result and same the time required. At 8, 12, 16 and 25 m cylinder, manual method showed 6.69, 3.46, 2.59, 1.24 CV values. The larger cylinder size became, the smaller CV became. In manual method, bone, air, water's CV were over 9.9 except BKG (2.32). Obtained CV of Mean SUV showed BKG was low (0.85) and bone was high (7.52). The time required was 45 second, 882 second respectably. Conclusions: As a result of difference automatic method and manual method, automatic method showed always same result, manual method showed that the smaller hot cylinders became, the lager CV became. Hot cylinders mean region size, the smaller hot cylinder size becomes we had some trouble in doing ROI poison setting. And it means increase in variation of SUV. The Study showed the time required of automatic method was shorten then manual method.

  • PDF

The Study of Hair Art about the Symbolism of the Pine (소나무 상징성에 대한 헤어아트 연구)

  • Chae, Seon-Sook;Lee, Jung-Min
    • Fashion & Textile Research Journal
    • /
    • v.9 no.5
    • /
    • pp.538-544
    • /
    • 2007
  • We usually try to accomodate ourselves to our nature surroundings interacting with nature. There fore I've decided to apply nature materials, esp. the pine to Hair Art as a way of expressing our feelings from Nature. 'Hair Art' is a follow-up study based on the various artistic point of view. There has been various works of 'Hair Art' with nature materials. However, it is rare to see a work of 'Hair Art' with the pine. That's why I've decided to study more about this. This study is a new experiment in 'Hair Art' against a conventional idea "Hair Art values practicability." Therefore, the primary goal of this study is to do much for the cause of learning in 'Hair Art' and encourages some development of 'Hair Art' industry. I've researched an image of a pine tree in art of Joseon Dynasty and contemporary art. Then I've tried to apply the image to a work of 'Hair Art'. First of all, in a view of expression technique for the symbolism of the pine, the artists in Joseon Dynasty drew pictures of a pine tree with a paintbrush but the modern artists make a new attempt from the thought of Modernism. We can find it in some photos. Next, to express traditional oriental idea such as 'unconventional and elegance', comtemporary artists chose the symbolism of the pine tree as an object of their works like pen and ink sketches from the thought of Modernism. Third, in a fusion style picture which contains features of both oriental paintings and western paintings and in a sexualism style picture that depicts a harmony of a male and a female as a shape of a pine, we can find colorful images of a pine tree and Their figurative beauty in art. Those are another symbols of the pine. In conclusion, the implication of the pine tree still hasn't changed even there are differences of drawings of pine tree in the past and the present. I've tried to combine these symbolic ideas of the pine with 'Hair Art' and made 5 hair styles. Throughout the process of researching this topic which is 'The Study of Hair Art Using The Symbolism of The Pine', I've realized that pine trees make it possible to express intrinsic tough spirit of human being and abundance in color and figurative beauty in art. I hope this can contribute to the field of 'Hair Art' and would become an important educational resource for further study.

Changes in the Number of Matching Points in CCTV's Stereo Images by Indoor/Outdoor Illuminance (실내·외 조도에 따른 스테레오 CCTV 영상 정합점 수 변화)

  • Moon, Kwang Il;Pyeon, Mu Wook;Kim, Jong Hwa;Kim, Kang San
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.23 no.1
    • /
    • pp.129-135
    • /
    • 2015
  • The Ubiquitous City (U-City) spatial information technology aimed to provide services freely anytime and anywhere by converging high-tech information & communication technology in urban infrastructure has been available in diverse patterns. In particular, there have been studies on the development of 3D spatial information after selecting and matching key points with stereo images from the many Closed Circuit TV (CCTV) in the U-City. However, the data mostly used in extracting matching points haven't considered external environmental impacts such as illuminance. This study tested how much the matching points needed to construct 3D spatial information with the CCTV whose image quality is dependent upon changes in illuminance fluctuate under the same hardware performances. According to analysis on the number of matching points by illuminance, the number of matching points increased up to 3,000Lux in proportion to the illuminance when IRIS, shutter speed and ISO were fixed. In addition, a border between an object and background became more distinctive. When there was too much light, however, the page became brighter, and noise occurred. Furthermore, it was difficult to name key points because of the collapse of an inter-object border. It appears that if filmed with the study results, the number of matching points would increase.

Improvement of Air Temperature Analysis by Precise Spatial Data on a Local-scale - A Case Study of Eunpyeong New Town in Seoul - (상세 공간정보를 활용한 국지기온 분석 개선 - 서울 은평구 뉴타운을 사례로 -)

  • Yi, Chae-Yeon;An, Seung-Man;Kim, Kyu-Rang;Choi, Young-Jean;Scherer, Dieter
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.15 no.1
    • /
    • pp.144-158
    • /
    • 2012
  • A higher spatial resolution is preferable to support the accuracy of detailed climate analysis in urban areas. Airborne LiDAR (Light Detection And Ranging) and satellite (KOMPSAT-2, Korea Multi-Purpose Satellite-2) images at 1 to 4 m resolution were utilized to produce digital elevation and building surface models as well as land cover maps at very high(5m) resolution. The Climate Analysis Seoul(CAS) was used to calculate the fractional coverage of land cover classes in built-up areas and thermal capacity of the buildings from their areal volumes. It then produced analyzed maps of local-scale temperature based on the old and new input data. For the verification of the accuracy improvement by the precise input data, the analyzed maps were compared to the surface temperature derived from the ASTER satellite image and to the ground observation at our detailed study region. After the enhancement, the ASTER temperature was highly correlated with the analyzed temperature at building (BS) areas (R=0.76) whereas there observed no correlation with the old input data. The difference of the air temperature deviation was reduced from 1.27 to 0.70K by the enhancement. The enhanced precision of the input data yielded reasonable and more accurate local-scale temperature analysis based on realistic surface models in built-up areas. The improved analysis tools can help urban planners evaluating their design scenarios to be prepared for the urban climate.